Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HOSPITALS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

TU-E-201-03: Eye Lens Dosimetry in Radiotherapy Using Contact Lens-Shaped Applicator

Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bomb survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable, actions on awareness can lead to avoidance or even prevention. Learning Objectives: To understand recent changes in eye lens dose limits and thresholds for tissue reactions To understand different approaches to dose estimation for eye lens To learn about challenges in eye lens opacities among staff in interventional fluoroscopy Di Zhang, Toshiba America Medical Systems, Tustin, CA, USA Eye lens radiation dose from brain perfusion CT exams CT perfusion imaging requires repeatedly exposing one location of the head to monitor the uptake and washout of iodinated contrast. The accumulated radiation dose to the eye lens can be high, leading to concerns about potential radiation injury from these scans. CTDIvol assumes continuous z coverage and can overestimate eye lens dose in CT perfusion scans where the table do not increment. The radiation dose to the eye lens from clinical CT brain perfusion studies can be estimated using Monte Carlo simulation methods on voxelized patient models. MDCT scanners from four major manufacturers were simulated and the eye lens doses were estimated using the AAPM posted clinical protocols. They were also compared to CTDIvol values to evaluate the overestimation from CTDIvol. The efficacy of eye lens dose reduction techniques such as tilting the gantry and moving the scan location away from the eyelens were also investigated. Eye lens dose ranged from 81 mGy to 279 mGy, depending on the scanner and protocol used. It is between 59% and 63% of the CTDIvol values reported by the scanners. The eye lens dose is significantly reduced when the eye lenses were not directly irradiated. CTDIvol should not be interpreted as patient dose; this study has shown it to overestimate dose to the eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice. These actions should be considered when they are consistent with the clinical task and patient anatomy. Learning Objectives: To become familiar with method of eye dose estimation for patient in specific situation of brain perfusion CT To become familiar with level of eye lens radiation doses in patients undergoing brain perfusion MDCT To understand methods for reducing eye lens dose to patient Jong Min Park, Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea Eye lens dosimetry in radiotherapy using contact lens-shaped applicator Dose calculation accuracy of commercial treatment planning systems is relatively low at shallow depths. Therefore, in-vivo measurements are often performed in the clinic to verify delivered doses to eye lens which are located at shallow depth. Current in-vivo dosimetry for eye lens during radiotherapy is generally performed with small in-vivo dosimeters on the surface of patient eyelid. Since this procedure potentially contains considerable uncertainty, a contact lens-shaped applicator made of acrylic (lens applicator) was developed for in-vivo measurements of eye lens dose during radiotherapy to reduce uncertainty. The lens applicator allows the insertion of commercially available metal oxide semiconductor field effect transistor (MOSFET) dosimeters. Computed tomography (CT) images of an anthropomorphic phantom with and without the lens applicator were acquired. A total of 20 VMAT plans were delivered to an anthropomorphic phantom and the doses with the lens applicator and the doses at the surface of the eyelid were measured using both micro and standard MOSFET dosimeters. The differences in measured dose at the surface of the eyelid from the calculated lens dose were acquired. The differences between the measured and the calculated doses at the lens applicator, as well as the differences between the measured and the calculated doses at the surface of the eyelid were acquired. The statistical significance of the differences was analyzed. The average difference between the measured and the calculated dose with the lens applicator was 16.8 % ± 10.4 % with a micro MOSFET dosimeter and 16.6 % ± 10.9% with a standard MOSFET dosimeter. The average difference without the lens applicator was 35.9% ± 41.5% with micro MOSFET dosimeter and 42.9% ± 52.2% with standard MOSFET dosimeter. The maximum difference with micro MOSFET dosimeter was 46% with the applicator and 188.4% without the applicator. For the standard MOSFET dosimeter, the maximum difference was 44.4% with the applicator and 246.4% without the applicator. The lens applicator allowed reduction of the differences between the calculated and the measured dose during in-vivo measurement for the eye lens as compared to in-vivo measurement at the surface of the eyelid. Learning Objectives: To understand limitations of dose calculation with commercial treatment planning system for eye lens during radiotherapy To learn about current in-vivo dosimetry methods for eye lens in the clinic To understand limitations of in-vivo dosimetry for eye lens during radiotherapy Di Zhang is an employee of Toshiba America Medical Systems.

60 APPLIED LIFE SCIENCES↗

TU-E-201-00: Eye Lens Dosimetry for Patients and Staff

Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bomb survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable, actions on awareness can lead to avoidance or even prevention. Learning Objectives: To understand recent changes in eye lens dose limits and thresholds for tissue reactions To understand different approaches to dose estimation for eye lens To learn about challenges in eye lens opacities among staff in interventional fluoroscopy Di Zhang, Toshiba America Medical Systems, Tustin, CA, USA Eye lens radiation dose from brain perfusion CT exams CT perfusion imaging requires repeatedly exposing one location of the head to monitor the uptake and washout of iodinated contrast. The accumulated radiation dose to the eye lens can be high, leading to concerns about potential radiation injury from these scans. CTDIvol assumes continuous z coverage and can overestimate eye lens dose in CT perfusion scans where the table do not increment. The radiation dose to the eye lens from clinical CT brain perfusion studies can be estimated using Monte Carlo simulation methods on voxelized patient models. MDCT scanners from four major manufacturers were simulated and the eye lens doses were estimated using the AAPM posted clinical protocols. They were also compared to CTDIvol values to evaluate the overestimation from CTDIvol. The efficacy of eye lens dose reduction techniques such as tilting the gantry and moving the scan location away from the eyelens were also investigated. Eye lens dose ranged from 81 mGy to 279 mGy, depending on the scanner and protocol used. It is between 59% and 63% of the CTDIvol values reported by the scanners. The eye lens dose is significantly reduced when the eye lenses were not directly irradiated. CTDIvol should not be interpreted as patient dose; this study has shown it to overestimate dose to the eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice. These actions should be considered when they are consistent with the clinical task and patient anatomy. Learning Objectives: To become familiar with method of eye dose estimation for patient in specific situation of brain perfusion CT To become familiar with level of eye lens radiation doses in patients undergoing brain perfusion MDCT To understand methods for reducing eye lens dose to patient Jong Min Park, Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea Eye lens dosimetry in radiotherapy using contact lens-shaped applicator Dose calculation accuracy of commercial treatment planning systems is relatively low at shallow depths. Therefore, in-vivo measurements are often performed in the clinic to verify delivered doses to eye lens which are located at shallow depth. Current in-vivo dosimetry for eye lens during radiotherapy is generally performed with small in-vivo dosimeters on the surface of patient eyelid. Since this procedure potentially contains considerable uncertainty, a contact lens-shaped applicator made of acrylic (lens applicator) was developed for in-vivo measurements of eye lens dose during radiotherapy to reduce uncertainty. The lens applicator allows the insertion of commercially available metal oxide semiconductor field effect transistor (MOSFET) dosimeters. Computed tomography (CT) images of an anthropomorphic phantom with and without the lens applicator were acquired. A total of 20 VMAT plans were delivered to an anthropomorphic phantom and the doses with the lens applicator and the doses at the surface of the eyelid were measured using both micro and standard MOSFET dosimeters. The differences in measured dose at the surface of the eyelid from the calculated lens dose were acquired. The differences between the measured and the calculated doses at the lens applicator, as well as the differences between the measured and the calculated doses at the surface of the eyelid were acquired. The statistical significance of the differences was analyzed. The average difference between the measured and the calculated dose with the lens applicator was 16.8 % ± 10.4 % with a micro MOSFET dosimeter and 16.6 % ± 10.9% with a standard MOSFET dosimeter. The average difference without the lens applicator was 35.9% ± 41.5% with micro MOSFET dosimeter and 42.9% ± 52.2% with standard MOSFET dosimeter. The maximum difference with micro MOSFET dosimeter was 46% with the applicator and 188.4% without the applicator. For the standard MOSFET dosimeter, the maximum difference was 44.4% with the applicator and 246.4% without the applicator. The lens applicator allowed reduction of the differences between the calculated and the measured dose during in-vivo measurement for the eye lens as compared to in-vivo measurement at the surface of the eyelid. Learning Objectives: To understand limitations of dose calculation with commercial treatment planning system for eye lens during radiotherapy To learn about current in-vivo dosimetry methods for eye lens in the clinic To understand limitations of in-vivo dosimetry for eye lens during radiotherapy Di Zhang is an employee of Toshiba America Medical Systems.

60 APPLIED LIFE SCIENCES↗

TU-E-201-01: Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionists

Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bomb survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable, actions on awareness can lead to avoidance or even prevention. Learning Objectives: To understand recent changes in eye lens dose limits and thresholds for tissue reactions To understand different approaches to dose estimation for eye lens To learn about challenges in eye lens opacities among staff in interventional fluoroscopy Di Zhang, Toshiba America Medical Systems, Tustin, CA, USA Eye lens radiation dose from brain perfusion CT exams CT perfusion imaging requires repeatedly exposing one location of the head to monitor the uptake and washout of iodinated contrast. The accumulated radiation dose to the eye lens can be high, leading to concerns about potential radiation injury from these scans. CTDIvol assumes continuous z coverage and can overestimate eye lens dose in CT perfusion scans where the table do not increment. The radiation dose to the eye lens from clinical CT brain perfusion studies can be estimated using Monte Carlo simulation methods on voxelized patient models. MDCT scanners from four major manufacturers were simulated and the eye lens doses were estimated using the AAPM posted clinical protocols. They were also compared to CTDIvol values to evaluate the overestimation from CTDIvol. The efficacy of eye lens dose reduction techniques such as tilting the gantry and moving the scan location away from the eyelens were also investigated. Eye lens dose ranged from 81 mGy to 279 mGy, depending on the scanner and protocol used. It is between 59% and 63% of the CTDIvol values reported by the scanners. The eye lens dose is significantly reduced when the eye lenses were not directly irradiated. CTDIvol should not be interpreted as patient dose; this study has shown it to overestimate dose to the eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice. These actions should be considered when they are consistent with the clinical task and patient anatomy. Learning Objectives: To become familiar with method of eye dose estimation for patient in specific situation of brain perfusion CT To become familiar with level of eye lens radiation doses in patients undergoing brain perfusion MDCT To understand methods for reducing eye lens dose to patient Jong Min Park, Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea Eye lens dosimetry in radiotherapy using contact lens-shaped applicator Dose calculation accuracy of commercial treatment planning systems is relatively low at shallow depths. Therefore, in-vivo measurements are often performed in the clinic to verify delivered doses to eye lens which are located at shallow depth. Current in-vivo dosimetry for eye lens during radiotherapy is generally performed with small in-vivo dosimeters on the surface of patient eyelid. Since this procedure potentially contains considerable uncertainty, a contact lens-shaped applicator made of acrylic (lens applicator) was developed for in-vivo measurements of eye lens dose during radiotherapy to reduce uncertainty. The lens applicator allows the insertion of commercially available metal oxide semiconductor field effect transistor (MOSFET) dosimeters. Computed tomography (CT) images of an anthropomorphic phantom with and without the lens applicator were acquired. A total of 20 VMAT plans were delivered to an anthropomorphic phantom and the doses with the lens applicator and the doses at the surface of the eyelid were measured using both micro and standard MOSFET dosimeters. The differences in measured dose at the surface of the eyelid from the calculated lens dose were acquired. The differences between the measured and the calculated doses at the lens applicator, as well as the differences between the measured and the calculated doses at the surface of the eyelid were acquired. The statistical significance of the differences was analyzed. The average difference between the measured and the calculated dose with the lens applicator was 16.8 % ± 10.4 % with a micro MOSFET dosimeter and 16.6 % ± 10.9% with a standard MOSFET dosimeter. The average difference without the lens applicator was 35.9% ± 41.5% with micro MOSFET dosimeter and 42.9% ± 52.2% with standard MOSFET dosimeter. The maximum difference with micro MOSFET dosimeter was 46% with the applicator and 188.4% without the applicator. For the standard MOSFET dosimeter, the maximum difference was 44.4% with the applicator and 246.4% without the applicator. The lens applicator allowed reduction of the differences between the calculated and the measured dose during in-vivo measurement for the eye lens as compared to in-vivo measurement at the surface of the eyelid. Learning Objectives: To understand limitations of dose calculation with commercial treatment planning system for eye lens during radiotherapy To learn about current in-vivo dosimetry methods for eye lens in the clinic To understand limitations of in-vivo dosimetry for eye lens during radiotherapy Di Zhang is an employee of Toshiba America Medical Systems.

60 APPLIED LIFE SCIENCES↗

TU-E-201-02: Eye Lens Dosimetry From CT Perfusion Studies

Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bomb survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable, actions on awareness can lead to avoidance or even prevention. Learning Objectives: To understand recent changes in eye lens dose limits and thresholds for tissue reactions To understand different approaches to dose estimation for eye lens To learn about challenges in eye lens opacities among staff in interventional fluoroscopy Di Zhang, Toshiba America Medical Systems, Tustin, CA, USA Eye lens radiation dose from brain perfusion CT exams CT perfusion imaging requires repeatedly exposing one location of the head to monitor the uptake and washout of iodinated contrast. The accumulated radiation dose to the eye lens can be high, leading to concerns about potential radiation injury from these scans. CTDIvol assumes continuous z coverage and can overestimate eye lens dose in CT perfusion scans where the table do not increment. The radiation dose to the eye lens from clinical CT brain perfusion studies can be estimated using Monte Carlo simulation methods on voxelized patient models. MDCT scanners from four major manufacturers were simulated and the eye lens doses were estimated using the AAPM posted clinical protocols. They were also compared to CTDIvol values to evaluate the overestimation from CTDIvol. The efficacy of eye lens dose reduction techniques such as tilting the gantry and moving the scan location away from the eyelens were also investigated. Eye lens dose ranged from 81 mGy to 279 mGy, depending on the scanner and protocol used. It is between 59% and 63% of the CTDIvol values reported by the scanners. The eye lens dose is significantly reduced when the eye lenses were not directly irradiated. CTDIvol should not be interpreted as patient dose; this study has shown it to overestimate dose to the eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice. These actions should be considered when they are consistent with the clinical task and patient anatomy. Learning Objectives: To become familiar with method of eye dose estimation for patient in specific situation of brain perfusion CT To become familiar with level of eye lens radiation doses in patients undergoing brain perfusion MDCT To understand methods for reducing eye lens dose to patient Jong Min Park, Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea Eye lens dosimetry in radiotherapy using contact lens-shaped applicator Dose calculation accuracy of commercial treatment planning systems is relatively low at shallow depths. Therefore, in-vivo measurements are often performed in the clinic to verify delivered doses to eye lens which are located at shallow depth. Current in-vivo dosimetry for eye lens during radiotherapy is generally performed with small in-vivo dosimeters on the surface of patient eyelid. Since this procedure potentially contains considerable uncertainty, a contact lens-shaped applicator made of acrylic (lens applicator) was developed for in-vivo measurements of eye lens dose during radiotherapy to reduce uncertainty. The lens applicator allows the insertion of commercially available metal oxide semiconductor field effect transistor (MOSFET) dosimeters. Computed tomography (CT) images of an anthropomorphic phantom with and without the lens applicator were acquired. A total of 20 VMAT plans were delivered to an anthropomorphic phantom and the doses with the lens applicator and the doses at the surface of the eyelid were measured using both micro and standard MOSFET dosimeters. The differences in measured dose at the surface of the eyelid from the calculated lens dose were acquired. The differences between the measured and the calculated doses at the lens applicator, as well as the differences between the measured and the calculated doses at the surface of the eyelid were acquired. The statistical significance of the differences was analyzed. The average difference between the measured and the calculated dose with the lens applicator was 16.8 % ± 10.4 % with a micro MOSFET dosimeter and 16.6 % ± 10.9% with a standard MOSFET dosimeter. The average difference without the lens applicator was 35.9% ± 41.5% with micro MOSFET dosimeter and 42.9% ± 52.2% with standard MOSFET dosimeter. The maximum difference with micro MOSFET dosimeter was 46% with the applicator and 188.4% without the applicator. For the standard MOSFET dosimeter, the maximum difference was 44.4% with the applicator and 246.4% without the applicator. The lens applicator allowed reduction of the differences between the calculated and the measured dose during in-vivo measurement for the eye lens as compared to in-vivo measurement at the surface of the eyelid. Learning Objectives: To understand limitations of dose calculation with commercial treatment planning system for eye lens during radiotherapy To learn about current in-vivo dosimetry methods for eye lens in the clinic To understand limitations of in-vivo dosimetry for eye lens during radiotherapy Di Zhang is an employee of Toshiba America Medical Systems.

60 APPLIED LIFE SCIENCES↗

WE-G-213-01: Roentgen and the Birth of Modern Medical Physics

Roentgen and the Birth of Modern Medical Physics – Perry Sprawls Wilhelm Roentgen is well known for his discovery of x-radiation. What is less known and appreciated is his intensive research following the discovery to determine the characteristics of the “new kind of radiation” and demonstrate its great value for medical purposes. In this presentation we will imagine ourselves in Roentgen’s mind and follow his thinking, including questions and doubts, as he designs and conducts a series of innovative experiments that provided the foundation for the rapid growth of medical physics. Learning Objectives: Become familiar with the personal characteristics and work of Prof. Roentgen that establishes him as an inspiring model for the medical physics profession. Observe the thought process and experiments that determined and demonstrated the comprehensive characteristics of x-radiation. The AAPM Award Eponyms: William D. Coolidge, Edith H. Quimby, and Marvin M.D. Williams - Who were they and what did they do? – Lawrence N. Rothenberg William David Coolidge (1873–1975) William Coolidge was born in Hudson, NY in 1873. He obtained his BS at the Massacusetts Institute of Technology in 1896. Coolidge then went to the University of Leipzig, Germany for graduate study with physicists Paul Drude and Gustave Wiedemann and received a Ph.D. in 1899. While in Germany he met Wilhelm Roentgen. Coolidge returned to the US to teach at MIT where he was associated with Arthur A. Noyes of the Chemistry Department, working on the electrical conductivity of aqueous solutions. Willis R. Whitney, under whom Coolidge had worked before going to Germany, became head of the newly formed General Electric Research Laboratory and he invited Coolidge to work with him. In 1905, Coolidge joined the staff of the GE laboratory and was associated with it for the remainder of his life. He developed ductile tungsten filaments to replace fragile carbon filaments as the material for electric light bulb filaments. Until that innovation light bulbs had a notoriously short life. He later incorporated the ductile tungsten as a filament material for a hot cathode, fully evacuated x-ray tube, first described in 1912, which allowed higher current and x-ray output, and greater reliability than had previously been possible. These “Coolidge x-ray tubes” were far superior to the cold cathode, partial pressure gas x-ray tubes that had been in use since Roentgen’s discovery of x-rays in 1895. The Coolidge tube with incremental developments is now the key component for x-ray production in all of our modern x-ray imaging devices, such as CT scanners, interventional radiology systems, and mammography units. Coolidge was also involved in the development of sectional x-ray tubes for research and treatment that were initially designed to reach 800 kV. Additional improvements led to 1 MV and 2 MV devices. In 1932 Coolidge became director of the General Electric Research Laboratory, and in 1940, was made Vice-President and Director of Research. In 1945 he retired and was named Director Emeritus of the laboratory. Coolidge held 83 patents and was recognized for these and many other achievements by election to the National Academy of Engineers, a place in the Engineering Hall of Fame and the National Inventor’s Hall of Fame. The AAPM’s highest honor, the Coolidge Award, was named after him. He accepted Honorary Membership in the AAPM and was the first recipient of the AAPM Coolidge Award, which was presented to him in a special ceremony in Schenectady, NY in 1972 when he was 100 years old. Edith Hinckley Quimby (1891–1982) Edith Quimby was born in Rockford, IL in 1891. She graduated from Whitman College in Walla Walla, WA with a B.S. in 1913, and then obtained a masters degree from the University of California at Berkeley. Later in her career, after many significant achievements, Quimby was awarded honorary doctorates by Whitman College and Rutgers University. Edith Quimby was hired by Giacchino Failla as a radiation physicist at Memorial Hospital for Cancer in New York City. Failla had studied with Madame Curie and obtained his doctoral degree in her laboratory. After many groundbreaking medical physics studies from 1919 until 1942, they both moved to Columbia University. Dr. Quimby developed a widely employed dosimetry system for single plane implants with radium and radon seeds, and a dosimetry methodology for internal radionuclides. She was author of more than 75 scientific publications, and of significant textbooks including the first comprehensive physics textbook for radiologists “Physical Foundations of Radiology”, which was co-authored with Otto Glasser, Lauriston Taylor and James Weatherwax in the first edition, with Russell Morgan added for the second edition and Paul Goodwin for the fourth edition. With Sergei Feitelberg, M.D. she published two editions of “Radioactive Isotopes in Medicine and Biology: Basic Physics and Instrumentation”. Quimby became a renowned examiner for the American Board of Radiology when the third ABR examination, given in 1936, added physics. She served as President of the American Radium Society, received the RSNA Gold Medal, and also numerous prestigious awards given to women in science. Edith Quimby was a Charter Member of AAPM. The AAPM Lifetime Achievement Award was renamed the Edith H. Quimby Lifetime Achievement Award in her honor in 2011. Marvin Martin Dixon Williams (1902–1981) Marvin Williams was born in Walla Walla, WA in 1902, and attended the same college as Edith Quimby, graduating from Whitman College in 1926. He was greatly influenced to go into medical physics by her accomplishments. During his early career, Williams worked with James Weatherwax in Philadelphia while he was working toward an M.S. from the University of Pennsylvania. In 1931 Williams was awarded a Ph.D. in Biophysics from the University of Minnesota, with the work actually performed at the Mayo Clinic Graduate School of the University. While completing his Ph.D. studies, Marvin met Dr. Paul Hodges who had returned from the Peiping Union Medical College in Peiping (now Beijing), China. Hodges suggested that a physicist be sent to Peiping to install x-ray therapy equipment and a radon plant. Williams accepted the position and, in 1931, he and his wife Orpha left for China. Before going to China, Williams had spent time with the physics group at Memorial Hospital to learn about the operation of a radon plant. In China, he constructed the radon plant, employing 0.25 g of radium, and also installed the x-ray therapy unit. Williams and his wife returned to the US in 1935, and he accepted a research position at the Mayo Clinic. In 1950, he became Professor of Biophysics at Mayo, where he taught physics and biophysics until his retirement in 1967. Williams was also very active in the American Board of Radiology where, from 1944 through 1977, he examined over 3000 radiologists and 250 physicists. Marvin Williams was a Charter member of AAPM, served as the fourth President of AAPM in 1963, and was the fourth recipient the AAPM Coolidge Award in 1975. The Marvin Williams Award was originally established as the highest award of the American College of Medical Physics. When various functions of the ACMP were absorbed into the AAPM in 2012, the Marvin M D Williams Professional Achievement Award became one of the AAPM’s highest honors. Learning Objectives: Become familiar with the persons in whose honor the three major AAPM Award are named Learn about the achievements and activities which influenced the AAPM to name these awards in their honor.

60 APPLIED LIFE SCIENCES↗

WE-G-213-00: History Symposium: Radiological Physics Pioneers: Roentgen and the AAPM Award Eponyms - William Coolidge, Edith Quimby, and Marvin Williams - Who Were They and What Did They Do?

Roentgen and the Birth of Modern Medical Physics – Perry Sprawls Wilhelm Roentgen is well known for his discovery of x-radiation. What is less known and appreciated is his intensive research following the discovery to determine the characteristics of the “new kind of radiation” and demonstrate its great value for medical purposes. In this presentation we will imagine ourselves in Roentgen’s mind and follow his thinking, including questions and doubts, as he designs and conducts a series of innovative experiments that provided the foundation for the rapid growth of medical physics. Learning Objectives: Become familiar with the personal characteristics and work of Prof. Roentgen that establishes him as an inspiring model for the medical physics profession. Observe the thought process and experiments that determined and demonstrated the comprehensive characteristics of x-radiation. The AAPM Award Eponyms: William D. Coolidge, Edith H. Quimby, and Marvin M.D. Williams - Who were they and what did they do? – Lawrence N. Rothenberg William David Coolidge (1873–1975) William Coolidge was born in Hudson, NY in 1873. He obtained his BS at the Massacusetts Institute of Technology in 1896. Coolidge then went to the University of Leipzig, Germany for graduate study with physicists Paul Drude and Gustave Wiedemann and received a Ph.D. in 1899. While in Germany he met Wilhelm Roentgen. Coolidge returned to the US to teach at MIT where he was associated with Arthur A. Noyes of the Chemistry Department, working on the electrical conductivity of aqueous solutions. Willis R. Whitney, under whom Coolidge had worked before going to Germany, became head of the newly formed General Electric Research Laboratory and he invited Coolidge to work with him. In 1905, Coolidge joined the staff of the GE laboratory and was associated with it for the remainder of his life. He developed ductile tungsten filaments to replace fragile carbon filaments as the material for electric light bulb filaments. Until that innovation light bulbs had a notoriously short life. He later incorporated the ductile tungsten as a filament material for a hot cathode, fully evacuated x-ray tube, first described in 1912, which allowed higher current and x-ray output, and greater reliability than had previously been possible. These “Coolidge x-ray tubes” were far superior to the cold cathode, partial pressure gas x-ray tubes that had been in use since Roentgen’s discovery of x-rays in 1895. The Coolidge tube with incremental developments is now the key component for x-ray production in all of our modern x-ray imaging devices, such as CT scanners, interventional radiology systems, and mammography units. Coolidge was also involved in the development of sectional x-ray tubes for research and treatment that were initially designed to reach 800 kV. Additional improvements led to 1 MV and 2 MV devices. In 1932 Coolidge became director of the General Electric Research Laboratory, and in 1940, was made Vice-President and Director of Research. In 1945 he retired and was named Director Emeritus of the laboratory. Coolidge held 83 patents and was recognized for these and many other achievements by election to the National Academy of Engineers, a place in the Engineering Hall of Fame and the National Inventor’s Hall of Fame. The AAPM’s highest honor, the Coolidge Award, was named after him. He accepted Honorary Membership in the AAPM and was the first recipient of the AAPM Coolidge Award, which was presented to him in a special ceremony in Schenectady, NY in 1972 when he was 100 years old. Edith Hinckley Quimby (1891–1982) Edith Quimby was born in Rockford, IL in 1891. She graduated from Whitman College in Walla Walla, WA with a B.S. in 1913, and then obtained a masters degree from the University of California at Berkeley. Later in her career, after many significant achievements, Quimby was awarded honorary doctorates by Whitman College and Rutgers University. Edith Quimby was hired by Giacchino Failla as a radiation physicist at Memorial Hospital for Cancer in New York City. Failla had studied with Madame Curie and obtained his doctoral degree in her laboratory. After many groundbreaking medical physics studies from 1919 until 1942, they both moved to Columbia University. Dr. Quimby developed a widely employed dosimetry system for single plane implants with radium and radon seeds, and a dosimetry methodology for internal radionuclides. She was author of more than 75 scientific publications, and of significant textbooks including the first comprehensive physics textbook for radiologists “Physical Foundations of Radiology”, which was co-authored with Otto Glasser, Lauriston Taylor and James Weatherwax in the first edition, with Russell Morgan added for the second edition and Paul Goodwin for the fourth edition. With Sergei Feitelberg, M.D. she published two editions of “Radioactive Isotopes in Medicine and Biology: Basic Physics and Instrumentation”. Quimby became a renowned examiner for the American Board of Radiology when the third ABR examination, given in 1936, added physics. She served as President of the American Radium Society, received the RSNA Gold Medal, and also numerous prestigious awards given to women in science. Edith Quimby was a Charter Member of AAPM. The AAPM Lifetime Achievement Award was renamed the Edith H. Quimby Lifetime Achievement Award in her honor in 2011. Marvin Martin Dixon Williams (1902–1981) Marvin Williams was born in Walla Walla, WA in 1902, and attended the same college as Edith Quimby, graduating from Whitman College in 1926. He was greatly influenced to go into medical physics by her accomplishments. During his early career, Williams worked with James Weatherwax in Philadelphia while he was working toward an M.S. from the University of Pennsylvania. In 1931 Williams was awarded a Ph.D. in Biophysics from the University of Minnesota, with the work actually performed at the Mayo Clinic Graduate School of the University. While completing his Ph.D. studies, Marvin met Dr. Paul Hodges who had returned from the Peiping Union Medical College in Peiping (now Beijing), China. Hodges suggested that a physicist be sent to Peiping to install x-ray therapy equipment and a radon plant. Williams accepted the position and, in 1931, he and his wife Orpha left for China. Before going to China, Williams had spent time with the physics group at Memorial Hospital to learn about the operation of a radon plant. In China, he constructed the radon plant, employing 0.25 g of radium, and also installed the x-ray therapy unit. Williams and his wife returned to the US in 1935, and he accepted a research position at the Mayo Clinic. In 1950, he became Professor of Biophysics at Mayo, where he taught physics and biophysics until his retirement in 1967. Williams was also very active in the American Board of Radiology where, from 1944 through 1977, he examined over 3000 radiologists and 250 physicists. Marvin Williams was a Charter member of AAPM, served as the fourth President of AAPM in 1963, and was the fourth recipient the AAPM Coolidge Award in 1975. The Marvin Williams Award was originally established as the highest award of the American College of Medical Physics. When various functions of the ACMP were absorbed into the AAPM in 2012, the Marvin M D Williams Professional Achievement Award became one of the AAPM’s highest honors. Learning Objectives: Become familiar with the persons in whose honor the three major AAPM Award are named Learn about the achievements and activities which influenced the AAPM to name these awards in their honor.

60 APPLIED LIFE SCIENCES↗

SU-F-T-214: Re-Thinking the Useful Clinical Beam Energy in Proton Therapy: An Opportunity for Cost Reduction

Purpose: We conducted a retrospective study of the useful clinical proton beam energy based on the beam range data of patients treated over the last 10 years at Massachusetts General Hospital Proton Therapy Center. Methods: Treatment field information were collected for all patients treated over the last 10 years (2005–2015) in the two gantry treatment rooms at MGH. The beam ranges for these fields were retrieved and categorized per treatment site. The 10 prostate patients that required the highest beam range (lateral fields) were selected. For these patients, anterior oblique beams (30–40 degrees) were simulated in a planning system to obtain the required beam ranges including the margins for potential range uncertainties. Results: There were a total of 4033 patients, treated with combined total of 23603 fields. All treatment indications were considered with the exception of ocular tumors generally treated in a fixed beam room. For all non-prostate treatments (21811 fields), only 5 fields for 4 patients (1-pancreas, 1-lumbar chordoma, 2-spine mets) required beam range greater than 25 cm. There were 446 prostate patients (1792 fields), with the required beam range from 22.3 to 29.0 cm; 386 of them had at least one of their lateral beam range greater than 25 cm. For the 10 prostate patients with highest lateral beam ranges (26 to 29 cm), their treatment with anterior oblique beams would drop the beam ranges below 25 cm (17.3 to 18.5 cm). Conclusion: if prostate patients are treated with anterior fields only, the useful maximum beam range is reduced to 25 cm. Thus a proton therapy system with maximum beam energy of 196 MeV is sufficient to treat all tumors sites with very rare exceptions (<0.1%). Designing such PT system would reduce the cost of proton therapy for hospitals and patients and increase the accessibility to the treatment.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP2-09: Iodine Imaging at Spectral CT with a Dual-Layer Detector

Purpose: To evaluate the attenuation response of iodine and the accuracy of iodine quantification on a detector-based spectral CT scanner. Methods: A Gammex 461A phantom was scanned using a dual-layer detector (IQon, Philips) at 120 kVp using helical acquisition with a CDTIvol of 15 mGy to approximate the hospital’s clinical body protocol. No modifications to the standard protocol were necessary to enable spectral imaging. Iodine inserts at 6 concentrations (2, 5, 7.5, 10, 15, 20 mg/ml) were scanned individually at the center of the phantom and the 20 mg/ml insert was additionally scanned at the 3, 6, and 12 o’clock positions. Scans were repeated 10 times. Conventional, virtual monoenergetic (40–200 keV) and iodine-no-water images (with pixel values equal to iodine concentration of corresponding tissue) were reconstructed from acquired data. A circular ROI (diameter=30 pixels) was used in each conventional and monoenergetic image to measure the mean and standard deviation of the CT number in HU and in each iodine-no-water image to measure iodine concentration in mg/ml. Results: Mean CT number and contrast-to-noise ratio (CNR) measured from monoenergetic images increased with decreasing keV for all iodine concentrations and matched measurements from conventional images at 75 keV. Measurements from the 20 ml insert showed the CT number is independent of location and CNR is a function only of noise, which was higher in the center. Measured concentration from iodine-no-water images matched phantom manufacturer suggested concentration to within 6% on average for inserts at the center of the phantom. Measured concentrations were systematically higher due to optimization of iodine quantification parameters for clinical mixtures of iodine and blood/tissue. Conclusion: Spectral acquisition and reconstruction with a dual-layer detector represents the physical behavior of iodine as expected and accurately quantifies the material concentration. This should permit a variety of clinical applications including lesion characterization, vessel patency, and myocardial perfusion. This study was performed as part of a research agreement among Philips Healthcare, University Hospitals of Cleveland, and Case Western Reserve University.

60 APPLIED LIFE SCIENCES↗

MO-DE-BRA-04: Hands-On Fluoroscopy Safety Training with Real-Time Patient and Staff Dosimetry

Purpose: Fluoroscopically guided interventions (FGI) are routinely performed across many different hospital departments. However, many involved staff members have minimal training regarding safe and optimal use of fluoroscopy systems. We developed and taught a hands-on fluoroscopy safety class incorporating real-time patient and staff dosimetry in order to promote safer and more optimal use of fluoroscopy during FGI. Methods: The hands-on fluoroscopy safety class is taught in an FGI suite, unique to each department. A patient equivalent phantom is set on the patient table with an ion chamber positioned at the x-ray beam entrance to the phantom. This provides a surrogate measure of patient entrance dose. Multiple solid state dosimeters (RaySafe i2 dosimetry systemTM) are deployed at different distances from the phantom (0.1, 1, 3 meters), which provide surrogate measures of staff dose. Instructors direct participating clinical staff to operate the fluoroscopy system as they view live fluoroscopic images, patient entrance dose, and staff doses in real-time. During class, instructors work with clinical staff to investigate how patient entrance dose, staff doses, and image quality are affected by different parameters, including pulse rate, magnification, collimation, beam angulation, imaging mode, system geometry, distance, and shielding. Results: Real-time dose visualization enables clinical staff to directly see and learn how to optimize their use of their own fluoroscopy system to minimize patient and staff dose, yet maintain sufficient image quality for FGI. As a direct result of the class, multiple hospital departments have implemented changes to their imaging protocols, including reduction of the default fluoroscopy pulse rate and increased use of collimation and lower dose fluoroscopy modes. Conclusion: Hands-on fluoroscopy safety training substantially benefits from real-time patient and staff dosimetry incorporated into the class. Real-time dose display helps clinical staff visualize, internalize, and ultimately utilize the safety techniques learned during the training. RaySafe/Unfors/Fluke lent us a portable version of their RaySafe i2 Dosimetry System for 6 months.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-IeP1-03: Establishment of Provincial Diagnostic Reference Levels in Pediatric Imaging

Purpose: To establish provincial diagnostic reference levels (DRLs) in pediatric general radiography and computed tomography (CT) as a tool for the optimization of exposure parameters. Methods: Patient dose survey was conducted in the only pediatric hospital in the province of Nova Scotia. The DRLs were established as the 75th percentile of patient dose distributions in different age groups. For routine radiography projections the DRLs were determined in terms of entrance surface dose (ESD) calculated from the radiation output measurements and the tube current-exposure time product (mAs) recorded for each examination. Patient thickness was measured by the technologist during the examination. The CR and DR systems, employing respectively a fixed technique and phototiming, were evaluated separately; a two-tailed Student’s t-test was used to determine the significance of differences between the means of dose distributions. The CT studies included routine head, chest, abdomen/pelvis, and chest/abdomen/pelvis. The volume CT dose index (CTDIvol) and dose-length product (DLP) values were extracted retrospectively from PACS. The correction factors based on the effective diameter of the patient were applied to the CT dosimetry metrics based on the standard phantoms. Results: The provincial DRLs were established in the following age groups: newborn, 1, 5, 10, and 15 year olds. In general radiography the DR systems demonstrated slightly lower dose than the CR for all views, however the differences were not statistically significant (p > 0.05) for all examinations. In CT the provincial DRLs were lower than the published data, except for head DLPs in all age categories. This might be due to the small patient sample size in the survey. Future work will include additional CT data collection over an extended period of time. Conclusion: Provincial DRLs were established in the dedicated children’s hospital to provide guidance for the other facilities in examinations of pediatric patients.

60 APPLIED LIFE SCIENCES↗

TU-D-201-02: Medical Physics Practices for Plan and Chart Review: Results of AAPM Task Group 275 Survey

Purpose: AAPM Task Group (TG) 275 is charged with developing riskbased guidelines for plan and chart review clinical processes. As part of this work an AAPM-wide survey was conducted to gauge current practices. Methods: The survey consisted of 103 multiple-choice questions covering the following review processes for external beam including protons: 1) Initial Plan Check, 2) On-Treatment and 3) End-of-Treatment Chart Check. The survey was designed and validated by TG members with the goal of providing an efficient and easy response process. The survey, developed and deployed with the support of AAPM headquarters, was released to all AAPM members who have self-reported as working in the radiation oncology field and it was kept open for 7 weeks. Results: There are an estimated 4700 eligible participants. At the time of writing, 962 completed surveys have been collected with an average completion time of 24 minutes. Participants are mainly from community hospitals (40%), academicaffiliated hospitals (31%) and free-standing clinics (18%). Among many other metrics covered on the survey, results so far indicate that manual review is an important component on the plan and chart review process (>90%) and that written procedures and checklists are widely used (>60%). However, the details of what is reviewed or checked are fairly heterogeneous among the sampled medical physics community. Conclusion: The data gathered from the survey gauging current practices will be used by TG 275 to develop benchmarks and recommendations for the type and extent of checks to perform effective physics plan and chart review processes.

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-FG-207B-11: Objective Image Characterization of Spectral CT with a Dual-Layer Detector

Purpose: To obtain objective reference data for the spectral performance on a dual-layer detector CT platform (IQon, Philips) and compare virtual monoenergetic to conventional CT images. Methods: Scanning was performed using the hospital’s clinical adult body protocol: helical acquisition at 120kVp, with CTDIvol=15mGy. Multiple modules (591, 515, 528) of a CATPHAN 600 phantom and a 20 cm diameter cylindrical water phantom were scanned. No modifications to the standard protocol were necessary to enable spectral imaging. Both conventional and virtual monoenergetic images were generated from acquired data. Noise characteristics were assessed through Noise Power Spectra (NPS) and pixel standard deviation from water phantom images. Spatial resolution was evaluated using Modulation Transfer Functions (MTF) of a tungsten wire as well as resolution bars. Low-contrast detectability was studied using contrast-to-noise ratio (CNR) of a low contrast object. Results: MTF curves of monoenergetic and conventional images were almost identical. MTF 50%, 10%, and 5% levels for monoenergetic images agreed with conventional images within 0.05lp/cm. These observations were verified by the resolution bars, which were clearly resolved at 7lp/cm but started blurring at 8lp/cm for this protocol in both conventional and 70 keV images. NPS curves indicated that, compared to conventional images, the noise power distribution of 70 keV monoenergetic images is similar (i.e. noise texture is similar) but exhibit a low frequency peak at keVs higher and lower than 70 keV. Standard deviation measurements show monoenergetic images have lower noise except at 40 keV where it is slightly higher. CNR of monoenergetic images is mostly flat across keV values and is superior to that of conventional images. Conclusion: Values for standard image quality metrics are the same or better for monoenergetic images compared to conventional images. Results indicate virtual monoenergetic images can be used without any loss in image quality or noise penalties relative to conventional images. This study was performed as part of a research agreement among Philips Healthcare, University Hospitals of Cleveland, and Case Western Reserve University.

60 APPLIED LIFE SCIENCES↗

Acoustic time-of-flight for proton range verification in water

Purpose: Measurement of the arrival times of thermoacoustic waves induced by pulsed proton dose depositions (protoacoustics) may provide a proton range verification method. The goal of this study is to characterize the required dose and protoacoustic proton range (distance) verification accuracy in a homogeneous water medium at a hospital-based clinical cyclotron. Methods: Gaussian-like proton pulses with 17 μs widths and instantaneous currents of 480 nA (5.6 × 10{sup 7} protons/pulse, 3.4 cGy/pulse at the Bragg peak) were generated by modulating the cyclotron proton source with a function generator. After energy degradation, the 190 MeV proton pulses irradiated a water phantom, and the generated protoacoustic emissions were measured by a hydrophone. The detector position and proton pulse characteristics were varied. The experimental results were compared to simulations. Different arrival time metrics derived from acoustic waveforms were compared, and the accuracy of protoacoustic time-of-flight distance calculations was assessed. Results: A 27 mPa noise level was observed in the treatment room during irradiation. At 5 cm from the proton beam, an average maximum pressure of 5.2 mPa/1 × 10{sup 7} protons (6.1 mGy at the Bragg peak) was measured after irradiation with a proton pulse with 10%–90% rise time of 11 μs. Simulation and experiment arrival times agreed well, and the observed 2.4 μs delay between simulation and experiment is attributed to the difference between the hydrophone’s acoustic and geometric centers. Based on protoacoustic arrival times, the beam axis position was measured to within (x, y) = (−2.0, 0.5) ± 1 mm. After deconvolution of the exciting proton pulse, the protoacoustic compression peak provided the most consistent measure of the distance to the Bragg peak, with an error distribution with mean = − 4.5 mm and standard deviation = 2.0 mm. Conclusions: Based on water tank measurements at a clinical hospital-based cyclotron, protoacoustics is a potential method for measuring the beam’s position (x and y within 2.0 mm) and Bragg peak range (2.0 mm standard deviation), although range verification will require simulation or experimental calibration to remove systematic error. Based on extrapolation, a protoacoustic arrival time reproducibility of 1.5 μs (2.2 mm) is achievable with 2 Gy of total deposited dose. Of the compared methods, deconvolution of the excitation proton pulse is the best technique for extracting protoacoustic arrival times, particularly if there is variation in the proton pulse shape.

07 ISOTOPE AND RADIATION SOURCES↗

Physiological roles of an Acinetobacter -specific σ factor

ABSTRACT The Gram-negative pathogen Acinetobacter baumannii is considered an “urgent threat” to human health due to its propensity to become antibiotic resistant. Understanding the distinct regulatory paradigms used by A. baumannii to mitigate cellular stresses may uncover new therapeutic targets. Many γ-proteobacteria use the extracytoplasmic function (ECF) σ factor, RpoE, to invoke envelope homeostasis networks in response to stress. Acinetobacter species contain the poorly characterized ECF “SigAb”; however, it is unclear if SigAb has the same physiological role as RpoE. Here, we show that SigAb is a metal stress-responsive ECF that appears unique to Acinetobacter species and distinct from RpoE-like ECFs. We combine promoter mutagenesis, motif scanning, and chromatin immunoprecipitation-sequencing (ChIP-seq) to define the direct SigAb regulon, which consists of genes encoding SigAb itself, the stringent response mediator, RelA, and the uncharacterized small RNA, “SabS.” However, RNA-seq of strains overexpressing SigAb revealed a large, indirect regulon containing hundreds of genes. Metal resistance genes are key elements of the indirect regulon, as CRISPRi knockdown of sigAb or sabS resulted in increased copper sensitivity and excess copper-induced SigAb-dependent transcription. Furthermore, we found that two uncharacterized genes in the sigAb operon, “ aabA ” and “ aabB ,” have anti-SigAb activity. Finally, employing a targeted Tn-seq approach that uses CRISPR-associated transposons, we show that sigAb , aabA , and aabB are important for fitness even during optimal growth conditions. Our work reveals new physiological roles for SigAb and SabS, provides a novel approach for assessing gene fitness, and highlights the distinct regulatory architecture of A. baumannii . IMPORTANCE Acinetobacter baumannii is a hospital-acquired pathogen, and many strains are resistant to multiple antibiotics. Understanding how A. baumannii senses and responds to stress may uncover novel routes to treat infections. Here, we examine how the Acinetobacter -specific transcription factor, SigAb, mitigates stress. We find that SigAb directly regulates only a small number of genes, but indirectly controls hundreds of genes that have substantial impacts on cell physiology. We show that SigAb is required for maximal growth, even during optimal conditions, and is acutely required during growth in the presence of elevated copper. Given that copper toxicity plays roles in pathogenesis and on copper-containing surfaces in hospitals, we speculate that SigAb function may be important in clinically relevant contexts.

Bacon, Emily E. (ORCID:0000000180907689)↗

Production of medical {sup 99m}Tc isotope via photonuclear reaction

{sup 99m}Tc with a 6 hour half-life is one of the most important medical isotopes used for the Single-Photon Emission Computed Tomography (SPECT) inspection in hospitals of US, Canada, Europe and Japan. {sup 99m}Tc isotopes are extracted by the milking method from parent {sup 99}Mo isotopes with a 66 hour half-life. The supply of {sup 99}Mo isotopes now encounters a serious crisis. Hospitals may not suitably receive {sup 99}Mo medical isotopes in near future, due to difficulties in production by research nuclear reactors. Many countries are now looking for alternative ways to generate {sup 99}Mo isotopes other than those with research reactors. We discuss a sustained availability of {sup 99m}Tc isotopes via the {sup nat}Mo(γ, n) photonuclear reaction, and discuss to solve technical problems for extracting pure {sup 99m}Tc isotopes from other output materials of photonuclear reactions.

07 ISOTOPE AND RADIATION SOURCES↗

Analyzing Infrastructure Interdependencies Using Network-Of-Networks Modeling

Infrastructure networks play a crucial role in our day-to-day lives, and modeling these infrastructure networks can help decisionmakers prepare for and respond to disruptions such as natural disasters or cyberattacks. Because these infrastructure networks depend on each other, it is not sufficient to model a single network in isolation. We build on previous single-network-modeling techniques to develop a methodology for modeling infrastructure interdependencies as a Network-of-Networks. Using distributionlevel data from a real U.S. city on the power grid, road geometry, and hospital locations, we show how to apply this methodology to modeling three of the U.S. Department of Homeland Security's Critical Infrastructure Sectors: Healthcare, Transportation, and Energy. We also analyze three primary metrics before and after a simulated disaster: 1) impact on hospital access; 2) road network impact with the change in betweenness centrality; 3) electric customer outage. We simulate three different disruptions: 1) road flooding from nearby rivers; 2) a malicious actor targeting the road networks; 3) a malicious actor targeting the electric grid. Finally, we discuss how our methodology can be applied to additional infrastructure networks and types of disruption, and how Artificial Intelligence (AI) techniques may be incorporated into this methodology for further research.

Scherrer, Evan [Drake University, Iowa]↗

ILI Code

This R code consists of three scripts, described below. 1. ILI_LHC_sample.R The first script generate 10,000 samples from the total parameter space formed by the ranges of the following five parameters inputted into the ILI model: transmission rate (beta), per capita rate of progress from exposed to infectious state (gamma_1), per capita rate of progress through initial infectious state (gamma_2), per capita rate of progress through hospitalized state (gamma_3), and per capita rate of progress through non-hospitalized infectious state (gamma_4). The output is LHS_samples.csv, for input into the global sensitivity script, ILI_SEIR. 2. ILI_SEIR.R The second script solves a standard Susceptible-Exposed-Infected- Recovered (SEIR) model (a system of Ordinary Differential Equations (ODEs)), runs global sensitivity analyses, and generates plots showing the impact of the input variables on the response variables for each virus. 3. virus_sims.R The third script solves a standard Susceptible-Exposed-Infected- Recovered (SEIR) model (a system of Ordinary Differential Equations (ODEs)), aimed at modeling outbreaks for five common upper respiratory viruses within a contained population. The output of this code is an epidemic curve to show timing and magnitude of the epidemic peak for each virus. Note: for all three scripts, the parameter values must be hard-coded by the user or the output will not be accurate.

Spencer, Julie↗

COVID-19 Outcomes by Cancer Status, Site, Treatment, and Vaccination

Background: Studies have shown an increased risk of severe SARS-CoV-2–related (COVID-19) disease outcome and mortality for patients with cancer, but it is not well understood whether associations vary by cancer site, cancer treatment, and vaccination status. Methods: Using electronic health record data from an academic medical center, we identified a retrospective cohort of 260,757 individuals tested for or diagnosed with COVID-19 from March 10, 2020, to August 1, 2022. Of these, 52,019 tested positive for COVID-19 of whom 13,752 had a cancer diagnosis. We conducted Firth-corrected logistic regression to assess the association between cancer status, site, treatment, vaccination, and four COVID-19 outcomes: hospitalization, intensive care unit admission, mortality, and a composite “severe COVID” outcome. Results: Cancer diagnosis was significantly associated with higher rates of severe COVID, hospitalization, and mortality. These associations were driven by patients whose most recent initial cancer diagnosis was within the past 3 years. Chemotherapy receipt, colorectal cancer, hematologic malignancies, kidney cancer, and lung cancer were significantly associated with higher rates of worse COVID-19 outcomes. Vaccinations were significantly associated with lower rates of worse COVID-19 outcomes regardless of cancer status. Conclusions: Patients with colorectal cancer, hematologic malignancies, kidney cancer, or lung cancer or who receive chemotherapy for treatment should be cautious because of their increased risk of worse COVID-19 outcomes, even after vaccination. Impact: Additional COVID-19 precautions are warranted for people with certain cancer types and treatments. Further, significant benefit from vaccination is noted for both cancer and cancer-free patients.

60 APPLIED LIFE SCIENCES↗