Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Germanium detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

The Hard X ray Telescope Mission

The Hard X Ray Telescope (HXT) was selected for study as a possible new intermediate size mission for the early 21st century. Its principal attributes are: (1) multiwavelength observing with a system of focussing telescopes that collectively observe from the UV to over 1 MeV, (2) much higher sensitivity and much better angular resolution in the 10100 keV band, and (3) higher sensitivity for detecting gamma ray lines of known energy in the 100 keV to 1 MeV band. The institutions collaborating in the study are: Smithsonian Astrophysical Observatory, Marshall Space Flight Center, Naval Research Laboratory, Goddard Space Flight Center, Argonne National Laboratory, Danish Space Research Institute, Osservatorio Astronomica di Brera (Merate), and Centre d'Etudes Spatiale des Rayonnements (Toulouse). The instrumentation includes several grazing incidence double conical telescopes with multilayer coatings that focus up to 100 keV and a single Laue crystal telescope that functions to 1 MeV. The detectors are CCDs, and germanium, and/or CdZnTe position sensitive arrays.

Gorenstein, Paul↗

Detector Arrays For Infrared Astronomy

Paper describes status of program for developing integrated infrared detectors for astronomy. Program covers variety of detectors, including extrinsic silicon, extrinsic germanium, and indium antimonide devices with hybrid silicon multiplexers. Paper notes for arrays to reach background noise limit in cryogenic telescope, continued reductions in readout noise and dark current needed.

Mccreight, C. R.↗

Cloud absorption radiometer

The Cloud Absorption Radiometer (CAR) was developed to measure spectrally how light is scattered by clouds and to determine the single scattering albedo, important to meteorology and climate studies, with unprecedented accuracy. This measurement is based on ratios of downwelling to upwelling radiation within clouds, and so is not strongly dependent upon absolute radiometric calibration of the instrument. The CAR has a 5-inch aperture and 1 degree IFOV, and spatially scans in a plane orthogonal to the flight vector from the zenith to nadir at 1.7 revolutions per second. Incoming light is measured in 13 spectral bands, using silicon, germanium, and indium-antimonide detectors. Data from each channel is digitally recorded in flight with 10-bit (0.1 percent) resolution. The instrument incorporates several novel features. These features are briefly detailed.

Strange, M. G.↗

Directions in gamma-ray spectroscopy

Current and future instrumentation for gamma-ray spectroscopy in the spectral range from 10 keV to 10 MeV is described. New technologies for Germanium (Ge) spectrometers and emerging detector technologies are highlighted. Scientific objectives are considered, with emphasis on capabilities beyond those of the Nuclear Astrophysics Explorer (NAE). A list of instrument requirements is given. Technologies under development for an NAE-era spectrometer are presented. Spectrometers beyond NAE and other types of future technologies are discussed, and a partial list of current and future spectrometers is provided.

Gehrels, Neil↗

Crystal Growth Using MEPHISTO

The shuttle flight experiment "In Situ Monitoring of Crystal Growth Using MEPHISTO" was accomplished during STS-87 as part of the fourth flight of the United States Microgravity Payload (USMP-4), which was flown from November 19 to December 5, 1997. The data returned from that flight are just now beginning to yield quantitative results. This project is an international collaboration: the furnace system known as MEPHISTO was built in France by CNES (French National Space Agency) and CEA (French Atomic Energy Commission); the principal investigator, Prof. Reza Abbaschian, is from the University of Florida at Gainesville; and numerical and analytical modeling support includes collaborators from the University of New South Wales, Australia, the University of Wisconsin at Milwaukee, the National Institute of Standards and Technology, and the NASA Lewis Research Center. MEPHISTO is a French acronym that translates into English as Materials for the Study of Interesting Phenomena of Solidification on Earth and in Orbit. Since this was the fourth flight of the MEPHISTO furnace, the experiment is referred to as MEPHISTO-4. MEPHISTO-4 was a directional solidification experiment that studied the liquid-to-solid transformation of bismuth alloyed with tin. Directional solidification is a freezing technique common to the processing of the electronic materials used in integrated circuits and detectors, such as silicon and germanium. When liquids are frozen on Earth, they must be cooled. The cooling causes stirring because of density variations in the liquid. This stirring, known as natural convection, influences the quality of the resulting solid. During freezing, regions of high and low concentrations of tin are created. This introduces another important phenomenon: diffusion, or the movement by molecular action of matter from regions of high concentration to regions of lower concentration. In MEPHISTO-4, it is tin that diffuses from the high-concentration region in front of the solid-liquid interface to more distant low-concentration regions.

deGroh, Henry C., III↗

Benchmarking Simulations of the Compton Spectrometer and Imager with Calibrations

The Compton Spectrometer and Imager (COSI) is a balloon-borne 𝛾-ray (0.2-5 MeV) telescope designed to study astrophysical sources. COSI employs a compact Compton telescope design utilizing 12 high-purity germanium double-sided strip detectors and is inherently sensitive to polarization. In 2016, COSI was launched from Wanaka, New Zealand and completed a successful 46-day flight on NASA’s new Super Pressure Balloon. In order to perform imaging, spectral, and polarization analysis of the sources observed during the 2016 flight, we compute the detector response from well-benchmarked simulations. As required for accurate simulations of the instrument, we have built a comprehensive mass model of the instrument and developed a detailed detector effects engine which applies the intrinsic detector performance to Monte Carlo simulations. The simulated detector effects include energy, position, and timing resolution, thresholds, dead strips, charge sharing, charge loss, crosstalk, dead time, and detector trigger conditions. After including these effects, the simulations closely resemble the measurements, the standard analysis pipeline used for measurements can also be applied to the simulations, and the responses computed from the simulations are accurate. We have computed the systematic error that we must apply to measured fluxes at certain energies, which is 6.3% on a rage. Here we describe the detector effects engine and the benchmarking tests performed with calibrations.

Sleator, Clio C.↗

The 100 micron detector development program

An effort to optimize gallium-doped germanium photoconductors (Ge:Ga) for use in space for sensitive detection of far infrared radiation in the 100 micron region is described as well as the development of cryogenic apparatus capable of calibrating detectors under low background conditions.

Moore, W. J.↗

Design improvements to cables and connectors in the Majorana Demonstrator

The Majorana Demonstrator is an experiment constructed to search for neutrinoless double-beta decays in germanium-76 and to demonstrate the feasibility to deploy a ton-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and 76 Ge-enriched germanium p-type point contact detectors totaling 44.1 kg, located at the 4850 level of the Sanford Underground Research Facility in Lead, South Dakota, USA. The Demonstrator uses custom high voltage cables to bias the detectors, as well as custom signal cables and connectors to read out the charge deposited at the point contact of each detector. These low-mass cables and connectors must meet stringent radio purity requirements while being subjected to thermal and mechanical stress. A number of issues have been identified with the currently installed cables and connectors. An improved set of cables and connectors for the Majorana Demonstrator are being developed with the aim of increasing their overall reliability and connectivity. In conclusion, we will discuss some of the issues encountered with the current cables and connectors as well as our improved designs and their initial performance.

42 ENGINEERING↗

Linearity of a Ge

Ge/Li/ drifted gamma detector for 1/2 to 10 Mev range, measuring response deviation from linearity

RADIATION DETECTOR↗

Si 1-X Ge X /Si Heterojunction Internal Photoemission Long Wavelength Infrared Detector

Long wavelength Si 1-X Ge X /Si heterojunction internal photoemission (HIP) infrared detectors have been successfully demonstrated utilizing the growth of degenerately boron doped Si 1-X Ge X layers on Si. Recently, Si 0.7 GE 0.3 /SI HIP detectors with either a Si 1-X Ge X single layer or a Si 1-X Ge X /Si multilayer have been demonstrated with cutoff wavelengths out to 23 µm. Near-ideal thermionic emission dark current characteristics were measured and the electrical potential barriers were determined by the Richardson plot. A photoresponse model, similar to the modified Fowler Equation has been developed for the Si 1-X Ge X /Si heterojunction internal photoemission infrared detector at wavelengths corresponding to photon energies less than the Fermi energy. The optical potential barriers, the corresponding cutoff wavelengths, and the emission coefficients, C 1 , for the HIP detectors have been determined from the measured spectral responses using the photoresponse model. Similar optical and thermal potential barriers were obtained.

infrared↗

Development of Nanocomposite Coatings for Future Large-Scale Time Projection Chambers

In the context of this award we tested the performance of thin high-resistivity coatings for their potential usage as field shaping systems in future large scale xenon Time Projection Chambers (TPC). A successful implementation of such thin coatings would likely simplify the design of potential future detectors, allowing to overcome some of the challenges observed with traditional systems constituted by massive discrete electrodes. We studied a wide range of materials and characterized their optical and electrical performances as functions of temperature and wavelength. The measurement campaign indicated that uniform coatings covering the full PTFE substrate (usually used as reflector in LXe TPCs) impact too severely on the light collection performance of such detectors when used with deep UV light. Despite tuning the composition and thicknesses of nanocomposite coatings, we were not able to identify a single coating, properly working at LXe temperature, that would simultaneously fulfill the resistance and optical requirements. Following the risk mitigation strategy identified in the proposal we moved the focus of the R&D to identify proper materials that, when coated with grid-like patterns on PTFE, would not alter meaningfully its optical properties (with respect to bare PTFE panels) but would still serve as effective field shaping systems, properly containing the drift field in TPC detectors. Among the various materials we identified germanium as the most promising one, providing a good adhesion to PTFE and the proper range of sheet resistivity. The Ge-patterned coating tested within a small scale LXe TPC showed good performance as a field shape system and, as desired, did not reduce the detector light yield. These results are encouraging and such technology should further be investigated as a potential alternative to more traditional field shaping electrodes. Incidentally, in the context of this R&D, we stumbled upon an unexpected behavior suggesting that some of the treatments performed on the PTFE panels, in preparation of the coatings, meaningfully boosted the PTFE reflectivity. The most probable candidate is the O2 plasma cleaning procedure. This hypothesis will be tested in the near future by operating the small scale TPC at UChicago first with regular PTFE panels and then with panels bombarded with O2 plasma (but no coatings). This finding, if confirmed, might open up the possibility of further boosting UV light collection in future large detectors by performing such a treatment on the PTFE surfaces.

36 MATERIALS SCIENCE↗

Machine learning-powered data cleaning for LEGEND: a semi-supervised approach using affinity propagation and support vector machines

Neutrinoless double-beta decay ($0\nu\beta\beta$) is a rare nuclear process that, if observed, will provide insight into the nature of neutrinos and help explain the matter-antimatter asymmetry in the Universe. The large enriched germanium experiment for neutrinoless double-beta decay (LEGEND) will operate in two phases to search for $0\nu\beta\beta$. The first (second) stage will employ 200 (1000) kg of High-Purity Germanium (HPGe) enriched in 76 Ge to achieve a half-life sensitivity of 10 27 (10 28 ) years. In this study, we present a semi-supervised data-driven approach to remove non-physical events captured by HPGe detectors powered by a novel artificial intelligence model. We utilize affinity propagation to cluster waveform signals based on their shape and a support vector machine to classify them into different categories. We train, optimize, and test our model on data taken from a natural abundance HPGe detector installed in the Full Chain Test experimental stand at the University of North Carolina at Chapel Hill. We demonstrate that our model yields a maximum sacrifice of physics events of $0.024 ^{+0.004}_{-0.003} \%$ after data cleaning. Our model is being used to accelerate data cleaning development for LEGEND-200 and will serve to improve data cleaning procedures for LEGEND-1000.

artificial intelligence↗

A reliable liquid helium detector

Detector and indicator system, utilizing commercial perforated germanium cryogenic thermometer as level sensor containing adjustable level discriminator with indicators, operates reliably over pressure range from 50 to 900 mm Hg without electronic adjustments.

Krawczonek, W. M.↗

On 3He bolometer systems

A 3He cryostat which was constructed to cool a germanium bolometer for use as an infrared detector at submillimeter wavelength is discussed. The system had better sensitivity than any other existing system for these wavelengths; the system could be improved if better optical coupling could be achieved between the bolometer and the incoming photon stream. Considerable effort was expended to improve this coupling. Even the best results however, fell short of an ideal system by a factor of nearly 5 in coupling efficiency.

Houck, J. R.↗

Monte Carlo Analysis of Coolant Stream Impurity Gamma Emissions in Gas-Cooled Fast Reactors

It is well established that a rapid increase in the concentration of fission products in the reactor coolant stream can serve as an early indication of fuel failure. We use Monte Carlo simulations to investigate the feasibility of using several gamma detectors as diagnostic equipment to monitor the presence of major fission product isotopes in high-temperature gas-cooled reactor (HTGR) coolant streams for early detection of fuel failure and therefore the prevention of fuel failure conditions. Herein we model the response of high-purity germanium (HPGe), CdZnTe, NaI(Tl), and LaBr 3 (Ce) detectors of typical commercial sizes to the gamma emissions from nuclides expected to be found within the coolant stream of the Versatile Test Reactor (VTR) under development by the U.S. Department of Energy. The results indicate that for the 233- and 250-keV gamma rays from 133 Xe and 135 Xe, respectively, the 3σ detection criterion is met in under 1 min using a single HPGe detector. Changes in other spectral lines associated with Xe nuclides are detected within 1 h regardless of the choice of detector.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evidence of Coherent Elastic Neutrino-Nucleus Scattering with COHERENT’s Germanium Array

We report the first detection of coherent elastic neutrino-nucleus scattering (CEvNS) on natural germanium, measured at the Spallation Neutron Source at Oak Ridge National Laboratory. The Ge-Mini detector of the COHERENT collaboration employs large-mass, low-noise, high-purity germanium spectrometers, enabling excellent energy resolution, and an analysis threshold of 1.5 keV electron-equivalent ionization energy. We observe an on-beam excess of 20.6$^{+7.1}_{−6.3}$ counts with a total exposure of 10.22 GWhkg, and we reject the no-CEvNS hypothesis with 3.9⁢𝜎 significance. The result agrees with the predicted standard model of particle physics signal rate within 2⁢𝜎.

Electroweak interaction↗

High resolution Fouier transform spectrometer Serial No. 091002: Instruction manual

A description of the spectrometer and procedures for its operation, maintenance, alignments, adjustments, and control functions are presented. The interferometer spectrometer is a modified Model 296 capable of 0.5/cm resolution over the spectral region of 5 to 15 microns configured for operation with the optical head at a temperature of approximately 80 K. Details are given on the optical system and the electronic circuits. The detector used with the optical head is mercury doped germanium kept at a temperature of about 4 K by means of liquid helium. Electronic schematics, and instruction manuals for handling the liquid helium dewars, tape recorder for analog outputs, and playback console are included.

Source record↗