Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GaGe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Heater Ensures Strain-Gage Bond Reliability

Aluminum block with embedded heating element provides concentrated and controllable heat for curing strain-gage adhesives. Device replaces heat lamps and hot-air guns; provides higher temperatures, allows shorter curing times, and ensures more reliable bond. Low temperatures and wind do not significantly affect operation of heater, therefore suited to outdoor use.

Brown, J. K.↗

Strain gage load measurement on the shuttle orbiter

This paper describes the application of the calibrated strain gage load measurement method to the shuttle orbiter. Descriptions of instrumentation and calibration are included, along with comparisons of measured results with wind tunnel and FLEXSTAB analytical predictions.

Carter, A. L.↗

Gas-Density Gage

Lightweight density gage that operates over broad pressure range accurately measures gas pressures.

Bernsterin, W.↗

Fuel Gage for Sloshing Tanks

New gage accurately measures fuel remaining in moving, or sloshing, tank. Measures tank air (or other gas) pressure and time required for pressure to change from one preselected level to another. Time measurement directly proportional to volume of air. Data processor computes relative volumes of air and fuel in tank.

Garner, H. D.↗

Effect of a buried-wire gage on the separation bubble Numerical study

A numerically simulated buried-wire separation gage is investigated with emphasis on its effect on the separation bubble. The conjugated problem of a supersonic, time-dependent, two-dimensional flowfield above a conductive solid wall with an embedded heat source is solved using implicit finite difference algorithms. Steady-state and transient cases were computed for different locations of the heat source within the bubble. Results show that by using a steady heat source, the flow direction near the wall can be detected, without distorting the flowfield, only if the source is located in regions where the bubble is thick (i.e., not too close to the separation). The flow direction near separation can be detected by using a temperature pulse at the solid/fluid interface with insignificant distortion of the flowfield.

Degani, D.↗

A Rapid Attachment of Strain Gages

Hand-held toroidal gun concentrates heat in localized area. New method for bonding film gages eliminates time-consuming oven curing Hand-held "gun," operates on induction heating to concentrate heat in localized area. Ferritic plate added for low-reluctance or no-reluctance surfaces.

Schott, T. D.↗

High temperature static strain gage alloy development program

The literature, applicable theory and finally an experimental program were used to identify new candidate alloy systems for use as the electrical resistance elements in static strain gages up to 1250K. The program goals were 50 hours of use in the environment of a test stand gas turbine engine with measurement accuracies equal to or better than 10 percent of full scale for strains up to + or - 2000 microstrain. As part of this effort, a computerized electrical resistance measurement system was constructed for use at temperatures between 300K and 1250K and heating and cooling rates of 250K/min and 10K/min. The two best alloys were an iron-chromium-aluminum alloy and a palladium base alloy. Although significant progress was made, it was concluded that a considerable additional effort would be needed to fully optimize and evaluate these candidate systems.

Hulse, C. O.↗

Errors associated with the use of strain gages on composite materials

The present effort to characterize the influence of strain gage misalignments in the case of their bonding to fiber-reinforced composite materials considers the effects of differences in thermal expansion, transverse sensitivity, and noncoincidence of principal stress on principal strain directions. The largest error is noted to be obtained when the minor Poisson ratio of a composite is measured. The correction procedures remain important for strain measurements on laminates.

Hiel, C. C.↗

Strain measurement technique for elevated temperature tensile and creep testing of foil-gage metals

This paper describes a strain measurement technique suitable for elevated-temperature tensile and creep testing of foil-gage metals, using a modified commonly available mechanical extensometer in conjunction with a displacement transducer. The extensometer was modified by attaching to it a counterbalance (to reduce the effect of the extensometer weight on the total maximum test load) and by incorporating a conical tip/flat-edge design (to minimize induced stresses in the specimen resulting from extensometer attachment). Creep tests were performed on 0.102-mm-thick specimens of Ti-6Al-4V at temperatures of 427 and 538 C, at nominal applied stresses of 310.3 and 172.4 MPa, respectively. Examination of the resulting creep curves suggested that the strain measurement system provided actual creep strain values with good accuracy.

Blackburn, L. B.↗

Electrical properties of materials for high temperature strain gage applications

A study was done on the electrical resistance of materials that are potentially useful as resistance strain gages at high temperatures under static strain conditions. Initially a number of binary alloys were investigated. Later, third elements were added to these alloys, all of which were prepared by arc melting. Several transition metals were selected for experimentation, most prepared as thin films. Difficulties with electrical contacts thwarted efforts to extend measurements to the targeted 1000 C, but results obtained did suggest ways of improving the electrical resistance characteristics of certain materials.

Brittain, John O.↗

Experience with strain-gage balances for cryogenic wind tunnels

The U.S. National Transonic Facility (NTF) is a cryogenic wind tunnel build to meet the United States' needs for high Reynolds number testing. The facility was declared operational in August 1984, and since that time numerous models were tested in the NTF using unheated strain-gage balances to measure aerodynamic forces. The difficulty in accurately measuring forces and moments of models in conventional wind tunnels becomes more challenging at cryogenic conditions. The Force and Strain Instrumentation Section of the Instrument Research Division at NASA Langley Research Center designed and fabricated the balances to measure forces at cryogenic temperatures without thermally controlling the balance temperature. Presented are balance results from a recent cryogenic test program in the NTF. The data indicated the accuracy with which aerodynamic forces are determined using current instrumentation and test methods as well as identified areas for future research.

Williams, M. Susan↗

Development of a dual strain gage balance system for measuring light loads

A strain-gage-balance (SGB) force-measurement system is described which was designed to meet light-load requirements for an airfoil model tested in the NASA Langley low-turbulence pressure tunnel (LTPT). This system was developed to obtain direct force data needed to verify calculated pressure/force correlations used in previous aerodynamic tests. The three-component force-measurement system was designed so that the SGBs would simultaneously support and measure the following loads: weight of the airfoil (approximately 3.0 lbf); 8.0 lbf of lift; 0.5 lbf of drag; and 16.0 in. lbf of pitching moment. In addition to these design loads, the system was required to withstand 100-percent overload on all three components. The system comprises an airfoil, two SGBs, a thermal flexure, and a mounting plate. The installation of the system in the LTPT is also discussed.

Roberts, Paul W.↗

Fluid quantity gaging

A system for measuring the mass of liquid in a tank on orbit with 1 percent accuracy was developed and demonstrated. An extensive tradeoff identified adiabatic compression as the only gaging technique that is independent of gravity or its orientation, and of the size and distribution of bubbles in the tank. This technique is applicable to all Earth-storable and cryogenic liquids of interest for Space Station use, except superfluid helium, and can be applied to tanks of any size, shape, or internal structure. Accuracy of 0.2 percent was demonstrated in the laboratory, and a detailed analytical model was developed and verified by testing. A flight system architecture is presented that allows meeting the needs of a broad range of space fluid systems without custom development for each user.

Mord, Allan J.↗

Atmospheric emissions and trends of nitrous oxide deduced from 10 years of ALE-GAGE data

Long-term measurements of nitrous oxide (N2O) obtained during the Atmospheric Lifetime Experiment (ALE) and the Global Atmospheric Gases Experiment (GAGE) for a period from 1978 to 1988 are presented and interpreted. It is observed that the average concentration in the Northern Hemisphere is 0.75 +/- 0.16 ppbv higher than in the Southern Hemisphere and that the global average linear trend in N2O lies in the range from 0.25 to 0.31 percent/year. The measured trends and latitudinal distributions are shown to be consistent with the hypothesis that stratospheric photodissociation is the major atmospheric sink for N2O, while the cause of the N2O trend is suggested to be a combination of a growing tropical source and a growing Northern mid-latitude source. A 10-year average global N2O emission rate of (20.5 +/- 2.4) x 10 to the 12th g N2O/year is deduced from the ALE/GAGE data.

Prinn, R.↗

Torsional Strength of Nickel Steel and Duralumin Tubing as Affected by the Ratio of Diameter to Gage Thickness

This investigation was made at the request of the Bureau of Aeronautics. Since the ordinary torsion formula is based on elastic resistance to deformation, it is inaccurate for determination of ultimate stresses in thin wall tubing subjected to torsional loads. It has been found that the torsional modulus of rupture varies with the ratio of diameter to gage thickness and the object of these tests was to determine the extent of these variations for subject materials. This is somewhat of a prorogation of work done by the Army Air Service at McCook Field.

Otey, N S↗

Strain gage measurement errors in the transient heating of structural components

Significant strain-gage errors may exist in measurements acquired in transient thermal environments if conventional correction methods are applied. Conventional correction theory was modified and a new experimental method was developed to correct indicated strain data for errors created in radiant heating environments ranging from 0.6 C/sec (1 F/sec) to over 56 C/sec (100 F/sec). In some cases the new and conventional methods differed by as much as 30 percent. Experimental and analytical results were compared to demonstrate the new technique. For heating conditions greater than 6 C/sec (10 F/sec), the indicated strain data corrected with the developed technique compared much better to analysis than the same data corrected with the conventional technique.

Richards, W. Lance↗

Use of photostress and strain gages to analyze behavior of weldments

Tensile and pure bending tests were conducted on specimens having welded joints made from 2219-T87 aluminum alloy and 2319 filler. Data were collected using photoelastic coatings and strain gages. Stress-strain relationships and contraction ratios were determined at several points in a grid covering the weld material and heat affected zone. Material behavior was nonlinear and nonuniform at all points in the grid and contraction ratios did not conform to those predicted by Chakrabarty's plasticity theory. Yielding in joints made using four new welding procedures was examined. None of the new procedures produced more uniform yielding in the joint.

Gambrell, S. C., Jr.↗

Strain Gage Measurement System to Determine Cryogenic Propellant Tank Level

Measurement of tank level, particularly for cryogenic propellants, has proven to be a difficult proposition. Current methods based on differential pressure, capacitance sensors, temperature sensors, etc.; do not provide sufficiently accurate or robust measurements, especially at run time. This paper describes a simple, but effective method to determine propellant volume by measuring very small deformations of the structure supporting the tank. Results of a laboratory study to validate the method, and experimental data from a deployed system are presented. A comparison with an existing differential pressure sensor shows that the strain gage system provides a very good quality signal even during pressurization.

Figueroa, Fernando↗