Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GROUND WATER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Membrane-Based Gas Traps for Ammonia, Freon-21, and Water Systems to Simplify Ground Processing

Gas traps are critical for the smooth operation of coolant loops because gas bubbles can cause loss of centrifugal pump prime, interference with sensor readings, inhibition of heat transfer, and blockage of passages to remote systems. Coolant loops are ubiquitous in space flight hardware, and thus there is a great need for this technology. Conventional gas traps will not function in micro-gravity due to the absence of buoyancy forces. Therefore, clever designs that make use of adhesion and momentum are required for adequate separation, preferable in a single pass. The gas traps currently used in water coolant loops on the International Space Station are composed of membrane tube sets in a shell. Each tube set is composed of a hydrophilic membrane (used for water transport and capture of bubbles) and a hydrophobic membrane (used for venting of air bubbles). For the hydrophilic membrane, there are two critical pressures, the pressure drop and the bubble pressure. The pressure drop is the decrease in system pressure across the gas trap. The bubble pressure is the pressure required for air bubbles to pass across the water filled membrane. A significant difference between these pressures is needed to ensure complete capture of air bubbles in a single pass. Bubbles trapped by the device adsorb on the hydrophobic membrane in the interior of the hydrophilic membrane tube. After adsorption, the air is vented due to a pressure drop of approximately 1 atmosphere across the membrane. For water systems, the air is vented to the ambient (cabin). Because water vapor can also transport across the hydrophobic membrane, it is critical that a minimum surface area is used to avoid excessive water loss (would like to have a closed loop for the coolant). The currently used gas traps only provide a difference in pressure drop and bubble pressure of 3-4 psid. This makes the gas traps susceptible to failure at high bubble loading and if gas venting is impaired. One mechanism for the latter is when particles adhere to the hydrophobic membrane, promoting formation of a water layer about it that can blind the membrane for gas transport (Figure 1). This mechanism is the most probable cause for observed failures with the existing design. The objective of this project was to devise a strategy for choosing new membrane materials (database development and procedure), redesign of the gas trap to mitigate blinding effects, and to develop a design that can be used in ammonia and Freon-21 coolant loops.

Ritchie, Stephen M. C.↗

Observations of water vapor by ground-based microwave radiometers and Raman lidar

In November to December 1991, a substantial number of remote sensors and in situ instruments were operated together in Coffeyville, Kansas, during the climate experiment First ISCCP Regional Experiment Phase 2 (FIRE 2). Includede in the suite of instruments were (1) the NOAA Environmental Technology Laboratory (ETL) three-channel microwave radiometer, (2) the NASA GSFC Raman lidar, (3) ETL radio acoustic sounding system (RASS), and (4) frequent, research-quality radiosondes. The Raman lidar operated only at night and the focus of this portion of the experiment concentrated on clear conditions. The lidar data, together with frequent radiosondes and measurements of temperature profiles (every 15 min) by RASS allowed profiles of temperature and absolute humidity to be estimated every minute. We compared 20 min measurements of brightness temperature (T(sub b) with calculations of T(sub b) that were based on the Liebe and Layton (1987) and Liebe et al. (1993) microwave propagation models, as well as the Waters (1976) model. The comparisons showed the best agreement at 20.6 GHz with the Waters model, with the Liebe et al. (1993) model being best at 31.65 GHz. The results at 90 GHz gave about equal success with the Liebe and Layton (1987) and Liebe et al. (1993) models. Comparisons of precipitable water vapor derived independently from the two instruments also showed excellent agreement, even for averages as short as 2 min. The rms difference between Raman and radiometric determinations of precipitable water vapor was 0.03 cm which is roughly 2%. The experiments clearly demonstrate the potential of simultaneous operation of radiometers and Raman lidars for fundamental physical studies of water vapor.

Han, Yong↗

Ground-based detection of water in Comet Halley

Gaseous water was detected in the coma of comet Halley. Emission was observed in the upsilon 1 + upsilon 3 band at 1.4 microns, and the upsilon 2 + upsilon 3 band at 1.9 microns. Based on the upsilon 1 + upsilon 3 band intensity, the mass loss rate is 2 times 10 to the 29th power molecules/sec (with an uncertainty of a factor of 2) on 29 Oct. 1985, marginally consistent with other detections. The method is applicable to observations of H2O in other fast-moving comets.

Knacke, R. F.↗

The Nature and State of Groundwater Contamination at the Nevada National Security Site: What Have We Learned from Decades of Groundwater Analysis? - 20337

The regulatory framework for remediating radionuclide contamination from underground nuclear testing at the Nevada National Security Site (NNSS) is based on a combination of characterization and modeling studies, monitoring, and institutional controls [1]. Currently, tritium is the largest contributor (∼90%) to the estimated 44.6 million-curie radionuclide inventory resulting from underground testing [2]. Because of its short half-life (12.32 years), its relative contribution reduces below 10% of the total radiologic inventory over the next 120 years as a result of radioactive decay. Although tritium levels are observed well above the Safe Drinking Water Act (SDWA) maximum contaminant levels (MCLs) in groundwater, other radionuclides are well below their MCLs except within the nuclear test near-field (nuclear test cavity and chimney) environment. In fact, most device-derived radionuclides are below their MCL in groundwater even in samples collected from this near-field environment. The distribution of radionuclides following the nuclear detonation greatly influences the availability of potential contaminants for groundwater transport. Tritium is initially distributed in the gas phase, later as tritiated water in steam, and finally as liquid water, and is available to groundwater transport away from the near-field environment. Other radionuclides that are mobile in groundwater are {sup 14}C, {sup 36}Cl, {sup 99}Tc, and {sup 129}I though their radiologic inventory is small when compared to tritium. Many radionuclides (e.g. U, Pu, Am) are incorporated to a significant extent into the melt glass at the bottom of the cavity and are accessible to groundwater primarily through the slow process of glass dissolution. These radionuclides are also adsorbed to the surfaces of the crushed rock within the cavity and chimney which limits their migration in groundwater. Although colloid facilitated transport of radionuclides at the NNSS has been observed [3], radionuclide concentrations decrease with time and migration distances due to desorption and colloid filtration processes. Current studies indicate that radionuclides associated with colloids are unlikely to migrate downgradient from NNSS underground nuclear tests at concentrations above the SDWA MCL [4][5]. The results of over 50 years of sampling, along with an understanding of these post detonation processes, indicate that tritium is the only contaminant of concern downgradient of testing and that even tritium will not exceed its MCL in groundwater after ∼120 years. Although other longer-lived radionuclides may continue to be released slowly from the near-field environment they will likely never reach levels exceeding their MCLs in groundwater downgradient of the NNSS. Groundwater monitoring will continue to verify these observations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Method Development for In Situ Microbiome Profiling of the Water Recovery System’s Wastewater Tank Onboard the International Space Station

A distinctive microbial community has inhabited the International Space Station (ISS) Water Recovery System (WRS) for over 14 years and has experienced the stressors associated with the microgravity environment. The WRS generates potable water for the crew from urine distillate, humidity condensate, Sabatier product water, and the occasional off-loading of ground-supplied water (1). The reservoir for these products, the wastewater tank, does not have a means of microbial control. Current in situ microbial monitoring of the WRS is limited to quarterly culture-based assessments of the potable water product using a microbial capture device and coliform detection bag. Additional analysis of the wastewater and condensate sources are collected into Teflon bags for analysis following return to the ground. The time between sample collection and the return to Earth, as well as the lack of preservation, results in a skewed depiction of the microbiome. Routinely observed from these returned wastewater samples are high counts (105 – 106 colony forming units per mL) and two prevailing genera, Ralstonia and Cupriavidus, as well as a high abundance of unidentified organisms (Table 1). The wastewater tank likely contains a more diverse microbiome, as a higher diversity of bacteria and fungi has been noted upstream and downstream of the tank.

Sarah Stahl-Rommel↗

Method Development for In Situ Microbiome Profiling of the Water Recovery System’s Wastewater Tank Onboard the International Space Station

A distinctive microbial community has inhabited the wastewater tank within the International Space Station Water Recovery System (WRS) for over 14 years and experienced the stressors associated with the microgravity environment. The WRS generates potable water for the crew from urine distillate, humidity condensate, Sabatier product water, and the occasional off-loading of ground-supplied water. The reservoir for these products, the wastewater tank, does not have a means of microbial control. While samples are occasionally collected for analysis, the time between sample collection and the return to Earth, as well as the lack of preservation, results in a skewed depiction of the microbiome. Routinely observed from these returned samples are high counts (105 – 106 colony forming units per mL) and two prevailing genera, Burkholderia and Ralstonia. The wastewater tank likely contains a more diverse microbiome, as a higher diversity of bacteria and fungus has been noted upstream and downstream of the tank. To characterize the microbial profile of the tank, analysis needs to occur at the time of sample collection. Toward this goal, a method for in situ analysis based on nanopore sequencing was developed. The filter-to-sequencer method evolved from previous work that has been validated onboard the ISS (BEST payload and the BioMole Crew Health Care Systems Facility). The method, including filtration, DNA extraction, purification, amplification, library preparation, and nanopore sequencing will be described. Additionally, data collected with this method from both ISS and terrestrial samples will be detailed. The consumables needed to support in situ analysis of the tank are set to the launch to the ISS in the spring of 2023. This investigation will allow for the first accurate characterization of the microbiome of the tank providing insight for crew health, planetary protection, and has the potential to enable engineering controls for future space station water systems.

Sarah Stahl-Rommel↗

Evaluation of Radar Vegetation Indices for Vegetation Water Content Estimation Using Data from a Ground-Based SMAP Simulator

Vegetation water content (VWC) is an important component of microwave soil moisture retrieval algorithms. This paper aims to estimate VWC using L band active and passive radar/radiometer datasets obtained from a NASA ground-based Soil Moisture Active Passive (SMAP) simulator known as ComRAD (Combined Radar/Radiometer). Several approaches to derive vegetation information from radar and radiometer data such as HH, HV, VV, Microwave Polarization Difference Index (MPDI), HH/VV ratio, HV/(HH+VV), HV/(HH+HV+VV) and Radar Vegetation Index (RVI) are tested for VWC estimation through a generalized linear model (GLM). The overall analysis indicates that HV radar backscattering could be used for VWC content estimation with highest performance followed by HH, VV, MPDI, RVI, and other ratios.

soil moisture↗

Capillary movement of liquid in granular beds

Knowledge of capillary migration of liquids in granular beds in microgravity is essential for the development of a substrate based nutrient delivery sytem for the growth of plants in space. This problem is also interesting from the theoretical as well as the practical point of view. The purpose of this study was to model capillary water propagation through a granular bed in microgravity. In our ground experiments, water propagation is driven primarily by capillary force. Data for spherical partical sizes in the range from 0.46 to 2 mm have been obtained. It was shown that the velocity of water propagation is very sensitive to particle size. Theoretical consideration is also provided. Actual space flight experiments are planned for the future to confirm our results.

Yendler, Boris↗

In-Flight Water Quality Monitoring on the International Space Station (ISS): Measuring Biocide Concentrations with Colorimetric Solid Phase Extraction (CSPE)

The colorimetric water quality monitoring kit (CWQMK) was delivered to the International Space Station (ISS) on STS-128/17A and was initially deployed in September 2009. The kit was flown as a station development test objective (SDTO) experiment to evaluate the acceptability of colorimetric solid phase extraction (CSPE) technology for routine water quality monitoring on the ISS. During the SDTO experiment, water samples from the U.S. water processor assembly (WPA), the U.S. potable water dispenser (PWD), and the Russian system for dispensing ground-supplied water (SVO-ZV) were collected and analyzed with the CWQMK. Samples from the U.S. segment of the ISS were analyzed for molecular iodine, which is the biocide added to water in the WPA. Samples from the SVOZV system were analyzed for ionic silver, the biocide used on the Russian segment of the ISS. In all, thirteen in-flight analysis sessions were completed as part of the SDTO experiment. This paper provides an overview of the experiment and reports the results obtained with the CWQMK. The forward plan for certifying the CWQMK as operational hardware and expanding the capabilities of the kit are also discussed.

Gazda, Daniel B.↗

Achieving the End State for the Pahute Mesa Corrective Action Units at the Nevada National Security Site - 20355

Underground nuclear testing at the Nevada National Security Site (NNSS) ended in 1992. To address the impact of radionuclide contamination from underground nuclear testing on the groundwater resources of Nevada, the U.S. Department of Energy (DOE) Environmental Management (EM) Nevada Program created the Underground Test Area (UGTA) activity to characterize the radionuclides in groundwater, understand the nature and extent of radionuclide migration, and forecast the distribution of radionuclides in groundwater for 1,000 years. The UGTA activity is regulated by the Federal Facility Agreement and Consent Order (FFACO), an agreement negotiated between the Nevada Division of Environmental Protection (NDEP), DOE, and the U.S. Department of Defense (DoD). DOE is close to achieving the end state (closure in place with monitoring and institutional control) for three of the five UGTA corrective action units (CAUs) on the NNSS. A number of challenges remain to achieve the end state of the other two CAUs, both located on Pahute Mesa. Pahute Mesa was the location of 82 underground nuclear tests, less than 10% of the total number of tests on the NNSS. Yet, Pahute Mesa contains slightly more than 60% of the total radionuclides (in curies). Based on groundwater sampling in monitoring wells, two radionuclide plumes have migrated several kilometers (km) in groundwater from selected test cavities and have crossed the boundary of the NNSS (yet remain within the boundaries of Federally controlled land). The path to achieve the end state continues to evolve as more data are collected and a better understanding of radionuclide migration in groundwater is developed. DOE has invested in drilling and sampling more than 50 characterization and monitoring groundwater wells over the past 25 years. The data indicate that the primary radionuclide of concern is tritium as it is about 89% of the total radionuclide inventory (in curies). As well, only tritium has been measured in groundwater outside of cavities at concentrations exceeding the Safe Drinking Water Act (SDWA) standard. For one of the tritium plumes that has migrated across the NNSS boundary, the average rate of migration has been measured as about 45 meters (m) per year with the rate of migration at the leading edge of the plume of about 85 meters per year. At that rate of migration, the tritium plume will decay to safe levels and not reach the publicly accessible environment at concentrations above the SDWA standard. Other radionuclides, at concentrations below the SDWA standards, will be monitored to ensure they remain at safe levels. Consequently, the end state path forward for Pahute Mesa has evolved to take full advantage of the data from the monitoring network to constrain uncertainty in model forecasts and to reduce reliance on probabilistic simulations. The focus of the end state approach relies on developing a monitoring well network that is protective of human health by increasing confidence that no radionuclide plume in the groundwater will migrate undetected to the accessible environment, located about 22 km from the nearest up-gradient underground nuclear test. Using the measured data to remove uncertainty, the evaluation of radionuclide migration from Pahute Mesa is directed toward meeting the goals of the end state. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ground-based microwave remote sensing of water vapor in the mesosphere and stratosphere

A ground-based, portable microwave radiometer that will be used to measure water vapor in the 30-80-km altitude region, and is to operate 24 hr a day, is described. The thermally excited 22.235-GHz rotational-transition line of water vapor is employed. The emission from this region produces a signal with an apparent brightness temperature of the order 0.1 to 0.5 K. A steerable reflector is used to provide optimal viewing angles, depending on the geographic location and season. Periodic tipping curve scans by this reflector permit determination of the amount of tropospheric correction that is applied to the data. All local oscillators in the receiver are crystal-controlled so that narrow-band spectral analysis of the received line shape can be performed.

Croskey, Charles L.↗

Possible seasonal variability of mesospheric water vapor

Ground-based spectral line measurements of the 22.2 GHz water vapor line in atmospheric emission were made at the Jet Propulsion Laboratory, which have been used to deduce the mesospheric water vapor profile. The measurements were made nearly continuously in the spring and early summer of 1984. The results indicate a temporal increase in the water vapor mixing ratio in the upper mesosphere from April through June. At 75 km, this increase is nearly by a factor of 2. Comparison of the present results with the results of a similar series of measurements made at the Haystack (radio astronomy) Observatory indicate that this temporal increase is part of a seasonal variation.

Bevilacqua, R. M.↗

Data and scripts associated with the manuscript evaluating the hydrologic responses of the Pacific Northwest watersheds to wildfires (v2)

This data package is associated with the publication “Evaluating Post-fire Watershed Response to Varying Burn Severity and Precipitation Regimes Using Fully-distributed and Integrated Hydrologic Models” submitted to Journal of Hydrology (Li et al. 2025). In this study, we employed the Advanced Terrestrial Simulator (ATS), an integrated watershed model that couples surface flow, subsurface flow, and canopy biophysical processes, to investigate post-fire hydrologic responses in a few selected watersheds with varying burn severity.The data package contains the required input data (meteorological forcing, Leaf Area Index, wildfire burn severities, etc.) to run the model, configuration files, the Jupyter notebooks in Python to pre-process and post-process data, the figures in the manuscript, and the modeling output files. The variables include watershed-averaged evapotranspiration, watershed-averaged surface/subsurface/canopy water content, and river discharge at watershed outlet.The data package contains a file-level metadata that lists and describes all the files contained in the data package (ATS_flmd.csv), a data dictionary file that defines columns headers across all csv files contained in the data package (ATS_dd.csv), a data package level readme file (the current file), and four zipped folders.The ‘data’ folder provides data needed to run the model in .h5, .i2s, .xyz, .shp, and .exo formats. The sub-folders are for each data types. The ‘model’ folder provides input files (.xml format) and essential model outputs. Each sub-folder provides the files from each simulated watershed. The ‘notebooks’ folder provides the Jupyter notebooks (.ipynb format) for pre- and post- processing model files, and for producing the figures in the manuscript. The ‘figures’ folder provides the figures associated with manuscript in .pdf and .png formats.The ‘model’ folder and the ‘data’ folder have been split into 5GB-large pieces using the Linux command ‘split -b 5120m model.zip model.zip.’ and ‘split -b 5120m data.zip data.zip.’, respectively. They can be merged back using the Linux command ‘cat model.zip.* > model.zip’ and ‘cat data.zip.* > data.zip’, respectively.

54 ENVIRONMENTAL SCIENCES↗

Data for Kim et al., "Variations in the optical and molecular composition of dissolved organic matter exported from coastal wetlands"

Knowledge about sources and composition of marsh-derived dissolved organic matter (DOM) is critical for understanding the role of marshes in coastal biogeochemical cycling and the fate of marsh-derived DOM in the ocean. To investigate tidal variability in composition of marsh-derived DOM, Kim et al. examined the optical and molecular characteristics of hourly surface water samples at three tidal creeks in the Chesapeake Bay. Groundwater samples along the terrestrial landscape gradient as well as estuarine water from the adjacent estuary at each site were also collected to help resolve sources of surface water DOM. Samples were collected in summer 2024 at three sites – SWH: Sweet Hall Marsh, GCW: Kirkpatrick Marsh, and GWI: Goodwin Islands – which are part of synoptic sites in the Chesapeake Bay region of the COMPASS-FME (Coastal Observations, Mechanisms, and Predictions Across Systems and Scales - Field, Measurements, and Experiments) project. Surface water samples were collected hourly over a 48-hour period at each site. Groundwater and estuarine water samples were collected once. This dataset includes- Surface water depth and salinity- Dissolved organic carbon (DOC) and total dissolved nitrogen (TDN) concentrations- Optical indices and relative composition of parallel factor analysis (PARAFAC) components- High resolution mass spectrometry data.

54 ENVIRONMENTAL SCIENCES↗