Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GAS INJECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

A Geostatistical Study in Support of CO 2 Storage in Deep Saline Aquifers of the Shenhua CCS Project, Ordos Basin, China

The Shenhua Carbon Capture and Storage (CCS) project at the Shenbei Slope injection site in North Yulin is the first 100,000 ton-per-year scale CCS pilot project in China with an injection operation lasting nearly 3 years. In this study, we investigate various geostatistical methods and their impact on the respective geologic models on which simulation is performed to understand the phenomena observed during 3 years of Shenhua CCS operations. Although there was a brief period of wellhead pressure increase at the injection well, it unexpectedly dropped for most of the time. Another interesting observation showed that the majority of CO 2 gas injection was received by the topmost sandstone Liujiagou formation instead of the basement limestone Majiagou formation, which was predicted to have much more injectivity and storage capacity. Based on the current geostatistical methods and available data, 3 steps of reservoir modeling and flow simulation are carried out and they go from having homogeneous property models to incorporating standard 2-point geostatistical methods to using object-based models. The layer-cake models generate a rather uniform plume shape and increased pressure response. Meanwhile, two-point statistical models add more complexity to the size and shape of CO 2 plume, however are not capable of reproducing the pressure decline behavior. These results demonstrate homogeneous and 2-point geostatistical models are inadequate in interpreting subsurface heterogeneity, both due to their method and data limitations. Further work is being done with object-based models to produce a system of meandering rivers based on the geological concept of Shenhua injection site. This will help offset the data limitation and bring our model closer to geologic reality.

54 ENVIRONMENTAL SCIENCES↗

Evolving Particles in the 2022 Hunga-Tonga Hunga-Ha’apai Volcano Eruption Plume

The Multi-angle Imaging SpectroRadiometer (MISR) aboard NASA’s Terra satellite observed the Hunga Tonga—Hunga Ha’apai (HTHH) 15 January eruption plume on eight occasions between 15 and 23 January 2022. From the MISR multi-angle, multi-spectral imagery we retrieve aerosol plume height geometrically, along with plume-level motion vectors, and derive radiometrically constraints on particle effective size, shape, and light-absorption properties. Parts of two downwind aerosol layers were observed in different places and times, one concentrated in the upper troposphere (11-18 km ASL), and a mid-stratosphere layer~23 –30+ km ASL. After the initial day (1/15), the retrievals identified only spherical, non-light-absorbing particles, typical of volcanic sulfate/water particles. The near-tropopause plume particles show constant, medium-small (several tenths of a micron) effective size over four days. The mid-stratosphere particles were consistently smaller, but retrieved effective particle size increased between 1/17 and 1/23, though they might have decreased slightly on 1/22. As a vast amount of water was also injected into the stratosphere by this eruption, models predicted relatively rapid sulfate particle growth from the modest amounts of SO2 gas injected by the eruption to high altitudes along with the water (Zhu et al, 2022). MISR observations up to ten days after the eruption are consistent with these model predictions. The possible decrease in stratospheric particle size after initial growth was likely caused by evaporation, as the plume mixed with drier, ambient air. Particles in the lower-elevation plume observed on 1/15 were larger than all the downwind aerosols and contained significant non-spherical (likely ash) particles.

aerosol plume height↗

Ground Testing of an Oxygen Concentrator in a Simulated International Space Station (ISS) Cabin Environment

The method for supplying medical oxygen to respiratorily-compromised astronauts on the International Space Station (ISS) and in future Orion missions consists of drawing oxygen from high pressure oxygen tanks. An Oxygen Concentrator Module (OCM) is a device that pulls in ambient air and separates out the nitrogen, resulting in a high concentration oxygen source. This technology has the potential to eliminate resupply and oxygen-enrichment issues associated with using high pressure oxygen tanks and become an alternative technology to support medical oxygen operations for future exploration missions. In this study, we test the long-term performance of a Commercial Off-the-Shelf (COTS) OCM in a simulated ISS cabin environment. Humidified air, carbon dioxide, and fifteen representative trace contaminants are continuously injected through a enclosed test chamber where the OCM is challenged. This study included the first successful demonstration of the Trace Gas Injection System (TGIS), which reliably and continuously produced ISS levels of trace contaminants, carbon dioxide, and humidity in an enclosed environment. The TGIS is a new and unique ground capability with significant implications for Test Readiness Level (TRL) advancement of COTS items and Government Furnished Equipment (GFE). This study demonstrated that the tested OCM reliably delivers enriched oxygen mostly at desired performance specifications. This study also demonstrated that the OCM does not inadvertently concentrate trace gases in its oxygen product stream, as detectable concentrations of trace contaminants in the oxygen product stream were at all times below the simulated ISS levels.

medical oxygen↗

Ground Testing of an Oxygen Concentrator in a Simulated International Space Station (ISS) Cabin Environment

The method for supplying medical oxygen to respiratorily-compromised astronauts on the International Space Station (ISS) and in future Orion missions consists of drawing oxygen from high pressure oxygen tanks. An Oxygen Concentrator Module (OCM) is a device that pulls in ambient air and separates out the nitrogen, resulting in a high concentration oxygen source. This technology has the potential to eliminate resupply and oxygen-enrichment issues associated with using high pressure oxygen tanks and become an alternative technology to support medical oxygen operations for future exploration missions. In this study, we test the long-term performance of a Commercial Off-the-Shelf (COTS) OCM in a simulated ISS cabin environment. Humidified air, carbon dioxide, and fifteen representative trace contaminants are continuously injected through an enclosed test chamber where the OCM is challenged. This study included the first successful demonstration of the Trace Gas Injection System (TGIS), which reliably and continuously produced ISS levels of trace contaminants, carbon dioxide, and humidity in an enclosed environment. The TGIS is a new and unique ground capability with significant implications for Test Readiness Level (TRL) advancement of COTS items and Government Furnished Equipment (GFE). This study demonstrated that the tested OCM reliably delivers enriched oxygen mostly at desired performance specifications. This study also demonstrated that the OCM does not inadvertently concentrate trace gases in its oxygen product stream, as detectable concentrations of trace contaminants in the oxygen product stream were at all times below the simulated ISS levels.

medical oxygen↗

Establishment of very uniform gas-flow pattern in the process chamber for microwave-excited high-density plasma by ceramic shower plate

The authors developed a ceramic upper shower plate used in the microwave-excited high-density plasma process equipment incorporating a dual shower-plate structure to establish a very uniform gas-flow pattern in the process chamber. Thousands of very fine gas-injection holes are implemented on this Al{sub 2}O{sub 3} upper shower plate with optimized allocation to establish a uniform gas-flow pattern of plasma-excitation gases and radical-generation gases for generating intended radicals in the plasma-excitation region. The size of these fine holes must be 50 {mu}m or less in diameter and 8 mm or more in length because these holes perform an essential role: They completely avoid the plasma excitation in these fine holes and upper gas-supply regions resulting from the plasma penetration into these regions from excited high-density plasma, even if very high-density plasma greater than 1x10{sup 12} cm{sup -3} is excited just under the ceramic upper shower plate by microwaves supplied from the radial line slot antenna. On the other hand, various process gases, such as material gases for film formations and etching gases, are supplied from the lower shower plate installed in the diffusion plasma region to this very uniform gas-flow pattern region of plasma-excitation gases and radical-generation gases. As a result, the process gases are supplied to the wafer surface in a very effective manner without excess decomposition of those process gas molecules and undesired reaction-product deposition on the inner surface of the process chamber. The process results are improved drastically by introducing the newly developed ceramic upper shower plate. But also, process uniformity on the entire wafer is improved with drastically reducing reaction-product deposition on the inner surface of the process chamber.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Gas exchange on Mono Lake and Crowley Lake, California

Gas exchange coefficients (k) have been determined for freshwater Crowley Lake and saline Mono Lake through the use of a man-made purposefully injected gas, SF6. The concentration decreased from an initial value of 40 to 4 pmol/L for Mono Lake and from 20 to 1 pmol/L for Crowley lake over a period of 6 wks. Wind-speed (u) records from anemometers on the shore of each lake made it possible to determine the relationship between k and u. The average u and k values for the experiment were identical for the two lakes, despite the large chemical differences. It is estimated that, for the u values observed over Mono Lake from July to December 1984, the exchange of CO2 occurred 2.5 times faster than without chemical enhancement. This is a factor of 4 lower than needed to explain the high invasion rate of C-14 produced by nuclear bomb tests.

Wanninkhof, Rik↗

The ReA electron-beam ion trap charge breeder for reacceleration of rare isotopes

ReA is a post-accelerator at the National Superconducting Cyclotron Laboratory at Michigan State University. ReA is designed to reaccelerate rare isotopes to energies of a few MeV/u following production by projectile fragmentation and thermalization in a gas cell. The facility consists of four main components: an electron-beam ion trap (EBIT) charge breeder, an achromatic charge-over-mass (Q/A) separator, a radio-frequency quadrupole accelerator, and a superconducting radio-frequency linear accelerator. The EBIT charge breeder was specifically designed to efficiently capture continuous beams of singly charged ions injected at low energy (<60 keV), charge breed in less than 50 ms, and extract highly charged ions to the Q/A separator for charge-state selection and reacceleration through the accelerator structures. The use of highly charged ions to reach high beam energies is a key aspect that makes ReA a compact and cost-efficient post-accelerator. The EBIT is characterized by a high-current electron gun, a long multi-electrode trap structure and a dual magnet to provide both the high electron-beam current density necessary for fast charge breeding of short-lived isotopes as well as the high capture probability of injected beams. This paper presents an overview and the status of the ReA EBIT, which has extracted for reacceleration tests stable {sup 20}Ne{sup 8+} ion beams produced from injected gas and more recently {sup 39}K{sup 16+} beams by injecting stable {sup 39,41}K{sup +} ions from an external ion source.

43 PARTICLE ACCELERATORS↗

Fuel recycling control in long pulse operation with full tungsten divertors in EAST tokamak

Fuel recycling control in long pulse discharges is studied in EAST tokamak with tungsten divertors by particle balance. Double null configuration, proper Resonant Magnetic Perturbation (RMP), divertor cryopumps and realtime lithium injection, are all very effective for recycling control. High heating power discharge leads to low recycling due to the enhancement of particle exhausting. High external gas injection is required in a low fuel recycling discharge to keep a constant density, and Dα emission is increased by external injection, therefore a higher Dα emission may indicate low fuel recycling for the same plasma density. Reproducible long pulse discharges of over 100 s with core electron temperature >10 keV, and 1056 s discharge with ~1.5 MW heating power were obtained in the EAST 2021 campaign, fuel recycling was well controlled by divertor cryopumps and realtime lithium injection. The results provide a valuable reference for the high power and long pulse operation in future fusion reactors, such as ITER and CFETR.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements and monitoring of the hydrogen and deuterium contents in the plasma of the L-2M stellarator

The program of experiments on ITER includes a sequential change of the plasma isotopic composition from pure hydrogen plasma in the initial stage of research to deuterium and, then, deuterium-tritium plasma with a gradual increase in the tritium content. In this context, the influence of the plasma isotopic composition on the processes of plasma heating and confinement are being actively studied on the existing tokamaks and stellarators. The plasma isotopic composition also depends on the composition of the gas desorbed from the vacuum chamber wall in the course of recycling. Therefore, the rate of change of the plasma isotopic composition after altering the injected gas also depends on the rate of change of the isotopic composition of the gas absorbed in the wall. These effects were studied in the experiments carried out on the L-2M stellarator in which the working gas was changed from hydrogen to deuterium. Spectral measurements of the intensity ratio between the H{sub {alpha}} and D{sub {alpha}} lines made it possible to monitor the isotopic composition of the plasma in the course of cleaning of the chamber wall from earlier absorbed hydrogen and its replacement with deuterium. After returning to hydrogen, the rate of cleaning of the wall from deuterium was also determined. The results of these experiments show that the plasma isotopic composition varies exponentially with the number N of shots after transition to another isotope, {approx}exp(-N/47). Hence, the isotopic composition can be changed almost completely over 2 to 3 working days. This allows one to study the influence of the plasma isotopic composition on plasma confinement during the same experimental session.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improvements to the High-Field-Side Transient CHI System on QUEST

Transient coaxial helicity injection (CHI) is a promising candidate for solenoid-free plasma current start-up in a low-aspect-ratio tokamak in support of developing fully non-inductive scenarios. The aim of the transient CHI research on QUEST is to develop a reactor-relevant CHI design. On QUEST, a CHI discharge is initiated by driving current along magnetic field lines that connect an electrically insulated electrode plate (which is referred to as a bias electrode) to a vessel component at the bottom region of the spherical tokamak. In the first application of CHI on QUEST, the electrically insulated electrode plate was biased with respect to the outer vessel in a configuration referred to as low-field-side (LFS) injection. To maintain a narrow injector flux footprint width throughout the discharge, QUEST is now developing a high-field-side (HFS) injection configuration, in which the electrically insulated electrode plate is biased with respect to the inner vessel components. Through the implementation of a CHI-dedicated gas injection system, studies in the HFS injection configuration have now demonstrated good magnetic flux evolution into the vacuum vessel. Toroidal currents up to 43 kA have been achieved, and the generated current has increased in proportion to the magnetic flux connecting the electrodes. Finally, these results which show agreement with the CHI-scaling suggest that much higher levels of toroidal current can be generated on QUEST in an optimized CHI system in which the magnetic flux connecting the CHI electrodes is further increased.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First results of Ne shattered pellet injection for mitigating plasma disruption with full metal wall in EAST tokamak

Disruption mitigation poses a significant and unresolved challenge for ITER and future fusion reactor devices. To mitigate the effect of plasma disruption, a Shattered Pellet Injection (SPI) system has been developed and the first rapid shutdown experiments have been successfully performed in the Experimental Advanced Superconducting Tokamak with full metal wall. The experiments confirmed the system’s capability to inject 5 mm diameter neon (Ne) pellets at velocities ranging from 100 to 400 m s −1 , with a maximum injected quantity of 13.2 Pa m 3 . Compared to unmitigated disruptions, the total radiation power was significantly higher with the respective use of SPI and Massive Gas Injection (MGI). Additionally, the radiation distribution and divertor heat flux were compared between SPI and MGI methods. The results demonstrated that SPI exhibited shorter cooling time, stronger core radiation and more uniform poloidal radiation distribution compared to MGI, indicating deeper deposition using SPI. Furthermore, during plasma shutdown, the electron temperature and peak heat flux near outer divertor strike points were reduced by 40% and 50% respectively, with SPI, in comparison to MGI. These findings serve as a valuable reference for implementing SPI technology as the baseline approach for disruption mitigation in ITER.

EAST↗

Supersonic Pulsed Injection

An injector has been developed to provide high-speed high-frequency (order 10 kHz) pulsed a supersonic crossflow. The injector nozzle is formed between the fixed internal surface of the nozzle and a freely rotating three- or four-sided wheel embedded within the device. Flow-induced rotation of the wheel causes the nozzle throat to open and close at a frequency proportional to the speed of sound of the injected gas. Measurements of frequency and mass flow rate as a function of supply pressure are discussed for various injector designs. Preliminary results are presented for wall-normal injection of helium into a Mach-2 ducted airflow. The data include schlieren images in the injectant plume in a plane normal to the flow, downstream of injection.

Cutler, A. D.↗

Quantity of 135 I released from the AGR-1, AGR-2, and AGR-3/4 experiments and discovery of 131 I at the FPMS traps during the AGR-3/4 experiment

A series of three Advanced Gas Reactor (AGR) experiments have been conducted in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). From 2006 through 2014, these experiments supported the development and qualification of the new U.S. tristructural isotropic (TRISO) particle fuel for Very High Temperature Reactors (VHTR). Each AGR experiment consisted of multiple fueled capsules, each plumbed for independent temperature control using a mix of helium and neon gases. The gas leaving a capsule was routed to individual Fission Product Monitor (FPM) detectors. For intact fuel particles, the TRISO particle coatings provide a substantial barrier to fission product release. However, particles with failed coatings, whether because of a minute percentage of initially defective particles, those which fail during irradiation, or those designed to fail (DTF) particles, can release fission products to the flowing gas stream. Because reactive fission product elements like iodine and cesium quickly deposit on cooler capsule components and piping structures as the effluent gas leaves the reactor core, only the noble fission gas isotopes of Kr and Xe tend to reach FPM detectors. The FPM system utilizes High Purity Germanium (HPGe) detectors coupled with a thallium activated sodium iodide NaI(Tl) scintillator. The HPGe detector provides individual isotopic information, while the NaI(Tl) scintillator is used as a gross count rate meter. During irradiation, the 135m Xe concentration reaching the FPM detectors is from both direct fission and by decay of the accumulated 135 I. About 2.5 hours after irradiation (ten 15.3 minute 135m Xe half lives) the directly produced 135m Xe has decayed and only the longer lived 135 I remains as a source. Decay systematics dictate that 135m Xe will be in secular equilibrium with its 135 I parent, such that its production rate very nearly equals the decay rate of the parent, and its concentration in the flowing gas stream will appear to decay with the parent half life. This equilibrium condition enables the determination of the amount of 135 I released from the fuel particles by measurement of the 135m Xe at the FPM following reactor shutdown. In this paper, the 135 I released will be reported and compared to similar releases for noble gases as well as the unexpected finding of 131 I deposition from intentional impure gas injection into capsule 11 of experiment AGR 3/4.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Progress towards the completion of the proton power upgrade project

The Proton Power Upgrade project at the Spallation Neutron Source at Oak Ridge National Laboratory will increase the proton beam power capability from 1.4 to 2.8 MW. Upon completion in early 2025, 2 MW of beam power will be available for neutron production at the existing first target station (FTS) with the remaining beam power available for the future second target station (STS). The project has installed seven superconducting radio-frequency (RF) cryomodules and supporting RF power systems to increase the beam energy by 30% to 1.3 GeV, and the beam current will be increased by 50%. The injection and extraction region of the accumulator ring are being upgraded, and a new 2 MW mercury target has been developed along with supporting equipment for high-flow gas injection to mitigate cavitation and fatigue stress. The first four cryomodules and supporting systems were commissioned in 2022-2023 and supported neutron production at 1.05 GeV, 1.7 MW with high reliability. The first-article 2 MW target was operated successfully for approximately 4400 MW-Hours over two run periods. The long outage began in August 2023 for installation of the remaining technical equipment and construction of the Ring-to-Target Beam Transport tunnel stub that will enable connection to the STS without interrupting operation of the FTS. The upgrade is proceeding on-schedule and on-budget, and resumption of neutron production for the user program is planned for July 2024.

43 PARTICLE ACCELERATORS↗

Progress on the Proton Power Upgrade Project at the Spallation Neutron Source

The Proton Power Upgrade Project at the Spallation Neutron Source at Oak Ridge National Laboratory will increase the proton beam power capability from 1.4 to 2.8 MW. Upon completion of the project, 2 MW of beam power will be available for neutron production at the existing first target station with the remaining beam power available for the future second target station. The project will install seven superconducting RF cryomodules and supporting RF power systems and ancillaries to increase the beam energy to 1.3 GeV . The injection and extraction region of the accumulator ring will be upgraded, and a new 2 MW mercury target has been developed along with supporting equipment for high-flow gas injection to mitigate cavitation and fatigue stress. Equipment is being received from vendors and partner laboratories, and installation is underway with three major installation outages planned in 2022-2024. The project is planned to be completed in 2025.

43 PARTICLE ACCELERATORS↗

Diffusion of trace gases for leak detection - A study

Study reveals quantitative measurements of the diffusion of trace gases /Freon and helium/ injected into systems by different methods. Results show that uniform mixing does not always occur, thus evaluation of the system under test and establishment of the method of trace gas injection are mandatory.

Brown, J. L.↗

Progress on the Proton Power Upgrade Project at the Spallation Neutron Source

The Proton Power Upgrade Project at the Spallation Neutron Source at Oak Ridge National Laboratory will increase the proton beam power capability from 1.4 to 2.8 MW. Upon completion of the project, 2 MW of beam power will be available for neutron production at the existing first target station with the remaining beam power available for the future second target station. The project will install seven superconducting RF cryomodules and supporting RF power systems and ancillaries to increase the beam energy to 1.3 GeV . The injection and extraction region of the accumulator ring will be upgraded, and a new 2 MW mercury target has been developed along with supporting equipment for high-flow gas injection to mitigate cavitation and fatigue stress. Equipment is being received from vendors and partner laboratories, and installation is underway with three major installation outages planned in 2022-2024. The project is planned to be completed in 2025.

Barbier, Charlotte↗

Progress towards the completion of the proton power upgrade project

The Proton Power Upgrade project at the Spallation Neutron Source at Oak Ridge National Laboratory will increase the proton beam power capability from 1.4 to 2.8 MW. Upon completion in early 2025, 2 MW of beam power will be available for neutron production at the existing first target station (FTS) with the remaining beam power available for the future second target station (STS). The project has installed seven superconducting radio-frequency (RF) cryomodules and supporting RF power systems to increase the beam energy by 30% to 1.3 GeV, and the beam current will be increased by 50%. The injection and extraction region of the accumulator ring are being upgraded, and a new 2 MW mercury target has been developed along with supporting equipment for high-flow gas injection to mitigate cavitation and fatigue stress. The first four cryomodules and supporting systems were commissioned in 2022-2023 and supported neutron production at 1.05 GeV, 1.7 MW with high reliability. The first-article 2 MW target was operated successfully for approximately 4400 MW-Hours over two run periods. The long outage began in August 2023 for installation of the remaining technical equipment and construction of the Ring-to-Target Beam Transport tunnel stub that will enable connection to the STS without interrupting operation of the FTS. The upgrade is proceeding on-schedule and on-budget, and resumption of neutron production for the user program is planned for July 2024.

Champion, Mark↗