Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fourier transforms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Exploring Biosignatures Associated with Thenardite by Geomatrix-Assisted Laser Desorption/Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (GALDI-FTICR-MS)

Geomatrix-assisted laser desorption/ionization (GALDI) in conjunction with a Fourier transform ion cyclotron resonance mass spectrometer (FTICR-MS) has been employed to determine how effectively bio/organic molecules associated with the mineral thenardite (Na2SO4) can be detected. GALDI is based on the ability of the mineral host to assist desorption and ionization of bio/organic molecules without additional sample preparation. When glycine was mixed with thenardite, glycine was deprotonated to produce C2H4NO-2 at m/z 74.025. The combination of stearic acid with thenardite produced a complex cluster ion at m/z 390.258 in the negative mode, which was assigned a composition ofC18H39O7Na-. Anatural sample of thenardite from Searles Lake in California also produced a peak at m/z 390.260. The bio/organic signatures in both the laboratory-based and natural samples were heterogeneously dispersed as revealed by chemical imaging. The detection limits for the stearic acid and thenardite combination were estimated to be 3 parts per trillion or~7 zeptomoles (10-21) per laser spot. Attempts to improve the signal-to-noise ratio by co-adding FTICR-MS data predetermined to contain the biosignatures of interest revealed problems due to a lack of phase coherence between data sets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimal Control for Fourier Transform on Qudits

In this work, we develop a protocol to find the optimal control pulse for implementing the Quantum Fourier Transform (QFT) on qudit-based hardware. We focus on two types of controls: (1) qubit-qudit dispersive coupling with qubit and qudit drives, and (2) qubit-qudit system with tunable coupling and qubit drive. We observe that for both systems, the minimum gate time grows linearly as a function of the size of the logical space. We find that the latter system supports faster pulses, requiring 45% shorter pulse time.

Ha, Triet↗

Observation of Potential Contaminants in Processed Biomass Using Fourier Transform Infrared Spectroscopy

With rapidly increased interests in biomass, diverse chemical and biological processes have been applied for biomass utilization. Fourier transform infrared (FTIR) analysis has been used for characterizing different types of biomass and their products, including natural and processed biomass. During biomass treatments, some solvents and/or catalysts can be retained and contaminate biomass. In addition, contaminants can be generated by the decomposition of biomass components. Herein, we report FTIR analyses of a series of contaminants, such as various solvents, chemicals, enzymes, and possibly formed degradation by-products in the biomass conversion process along with poplar biomass. This information helps to prevent misunderstanding the FTIR analysis results of the processed biomass.

09 BIOMASS FUELS↗

Fourier transform spectrometry for fiber-optic sensor systems

An integrated-optic Mach-Zehnder interferometer is used as a Fourier transform spectrometer to analyze the input and output spectra of a temperature-sensing thin-film etalon. This type of spectrometer has an advantage over conventional grating spectrometers because it is better suited for use with time-division-multiplexed sensor networks. In addition, this spectrometer has the potential for low cost due to its use of a component that could be manufactured in large quantities for the optical communications industry.

Beheim, Glenn↗

A comprehensive review of diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) techniques in protonic ceramic cells (PCCs): Current status and future perspective

Protonic ceramic cells (PCCs) have emerged as a promising technology for power generation, energy storage, and value-added chemical synthesis, offering benefits such as fuel flexibility, low emissions, and efficient operation at intermediate temperatures (300–600 ​°C). Recently, significant breakthroughs in materials and manufacturing methods have markedly enhanced the performance of PCCs. However, establishing a fundamental understanding of their electrocatalytic reactions has gained less attention. As a fast and cost-effective method for physicochemical fingerprinting, diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) has proven to be a surface-sensitive analytical tool for structural and functional studies. This review critically examines the most up-to-date applications of DRIFTS for characterizing key components of PCCs, including oxygen electrodes, protonic electrolytes, and hydrogen electrodes for different applications, with a focus on revealing hydration properties and catalytic reactions, and guiding rational material design. The challenges for advancing DRIFTS, including quantitative capabilities and operando applications for PCC investigations, are highlighted and strategies to tackle these challenges are discussed. Ultimately, this review underscores the critical role of DRIFTS in accelerating the development of high-performance and durable PCCs for next-generation energy solutions, offering methodologies and insights broadly applicable to a wide range of electrochemical energy conversion and storage technologies.

Diffuse Reflectance Infrared Fourier Transform Spe↗

Characterization of Sequentially Extracted Soil Organic Matter by Electrospray Ionization and Atmospheric Pressure Photoionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry

Soil organic matter (SOM) is a complex mixture of small molecules and biopolymers that are active in various biogeochemical processes. However, the chemical diversity of biopolymer-derived SOM remains poorly explored. Identifying this diversity is important because global environmental changes may well alter SOM chemistry, as field experiments are beginning to show. Here, organic solvent-extractable (DcMe-SOM), base-hydrolyzable (KOH Hy -SOM), and CuO-oxidizable (CuO Ox -SOM) SOM fractions from a forest with a long-term nitrogen addition experiment were sequentially extracted and characterized by Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) coupled with negative-ion electrospray ionization (ESI) or atmospheric pressure photoionization (APPI). From DcMe-SOM to CuO Ox -SOM, the total number of assigned formulas, average O/C ratio, aromaticity, and unsaturation degree of SOM continuously increased, while the average m/z and H/C ratio decreased. Moreover, the dominant chemical category shifted from lipid-like components to phytochemical- and protein-like components. Complementary to ESI, APPI effectively facilitated detection of additional compounds with low polarity. With long-term nitrogen addition, the average m/z, unsaturation degree, aromaticity, and oxidation state of SOM increased, and more aromatic nitrogen-containing formulas were detected in CuOOx-SOM. Our study demonstrates that chronic nitrogen deposition in forests alters both the small molecules and biopolymers of SOM fundamentally.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coolant Pump Predictive Data Analytics from Signatures Generated by the Recursive Short Time Fast Fourier Transform

Although a nuclear reactor is a hostile environment for sensors and signal transmissions, the reactor core is amenable to acoustic communication. An acoustic measurement infrastructure installed at the Advanced Test Reactor (ATR) nozzle trench area records acoustic signals that can capture reactor operating states. The distinct states produce unique signatures that can be identified and tracked using data processing and data analytics. The infrastructure relies on acoustic transmission through ATR in-pile structural components, piping, and coolant that transmit acoustically modified signals generated by the coolant pumps. This paper will discuss results from using the Recursive Short Time Fast Fourier Transform (RSTFFT) technique used to process acoustic signals and provide signatures that are identified and monitored by analytics. The RSTFFT is applied to ATR data to understand the vibration levels and signatures for different operating regimes as displayed by the spectrogram. The combination of coolant pumps for normal and high-power operation generate unique signatures. These acoustic signatures are used to develop machine learning approaches to automatically classify operating regimes. Two machine-learning models, Support Vector Machines and Linear Discriminant Analysis, were developed to classify two event classes. Class 1 is a normal steady-state operation, and Class 2 is any event that is due to start up, shut down, or other actions. Both types of machine learning models had over a 96% prediction accuracy for the two classes. These results lay the foundation for predictive analytic frameworks that can be leveraged by ATR to optimize operations and maintenance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ARM West Antarctic Radiation Experiment (AWARE) Fourier Transform Infrared Filter Sampling Systems Field Campaign Report

West Antarctica is one of the most rapidly warming regions in the world (Bromwich et al. 2013; Steig et al. 2009) and the warming can directly cause sea level rise (King et al. 2012). In situ measurements are needed to examine and quantify the meteorological conditions in order to precisely understand the effect of warm air and clouds on the West Antarctic Ice Shelf (WAIS). The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) West Antarctic Radiation Experiment (AWARE) is designed to collect measurements with advanced cloud and aerosol instrumentation at West Antarctica. The Fourier Transform Infrared (FTIR) filter sampling systems were deployed as part of the ARM West Antarctic Radiation Experiment (AWARE) campaign to measure organic aerosol characteristics at McMurdo Station. As a coastal station at the southern end of Ross Island, McMurdo Station has a meteorological relationship with the WAIS via circulation patterns in the Ross and Amundsen Seas. Thirteen months of continuous observations of aerosol particle composition extended from December 2016 to January 2017. Filter samples were collected at McMurdo on pre-scanned Teflon filters (Teflon, Pall Inc., 37mm diameter) behind PM1 sharp-cut cyclones (SCC2.229 PM1, BGI Inc). Samples were collected each week with approximately 50-90 m3 air filtered per sample. Samples were frozen and transported below 0°C to the Scripps laboratory for FTIR spectroscopy analysis. A Bruker Tensor 27 FTIR spectrometer with a deuterated triglycine sulfate (DTGS) detector (Bruker, Waltham, MA) was used to scan the filters both before and after sampling. An automated algorithm (Takahama et al. 2013) was applied to quantify the mass of the organic functional groups. Four groups (alkane, amine, alcohol, and carboxylic acid) had absorption peaks above the limits of quantification, and the sum of the mass of the four functional groups is the quantified organic mass (OM). Absorption peaks for other groups (organosulfate, organonitrate, aromatic, and alkene group) were identified and fit but they were below the limit of quantification for more than 90% of the samples and are excluded. Similar FTIR measurements has been conducted in dozens of field campaigns around the world, including arctic regions (Russell et al. 2011). Local particle emissions from airports, diesel generators, and local transportation affected all aerosol measurements at various times during this project. The ARM Aerosol Measurement Science Group is aware of the issue and is working to develop algorithms to flag the data. This influence is evident in the FTIR measurements as it is associated with specific chemical signatures. DOE and the National Science Foundation, which manages the U.S. Antarctic Program, supported this collaboration for AWARE.

ARM West Antarctic Radiation Experiment, Fourier T↗

Fourier-transform infrared spectroscopy for rapid screening and live-cell monitoring: application to nanotoxicology

A significant challenge to realize the full potential of nanotechnology for therapeutic and diagnostic applications is to understand and evaluate how live-cells interact with an external stimulus, e.g., a nanosized particle (NSP), and the toxicity and broad risk associated with these stimuli. NSPs are increasingly used in medicine with largely undetermined hazards in complex cell dynamics and environments. It is difficult to capture the complexity and dynamics of these interactions by following an omics-based approach exclusively, which are expensive and time-consuming. Additionally, this approach needs destructive sampling methods. Live-cell attenuated total reflectance-Fourier transform infrared (ATR-FTIR) spectrometry is well suited to provide noninvasive approach to provide rapid screening of cellular responses to potentially toxic NSPs or any stimuli. Herein we review the technical basis of the approach, the instrument configuration and interface with the biological media, and various effects that impact the data, data analysis, and toxicity. Our preliminary results on live-cell monitoring show promise for rapid screening the NSPs.

nanosized particle, toxicity, in vitro, spectrosco↗

In situ examination of osteoblast biomineralization on sulfonated polystyrene-modified substrates using Fourier transform infrared microspectroscopy

Osteoporosis is a skeletal disorder that is characterized by the loss of bone mineral density (BMD) resulting in increased risk of fracture. However, it has been shown that BMD is not the only indicator of fracture risk, as the strength of bone depends on a number of factors, including bone mass, architecture and material properties. We present that physiological mineral deposition requires the formation of a properly developed extracellular matrix (ECM), which recruits calcium and phosphate ions into the synthesis of apatite crystals. Temporal and spatial compositional and structural changes of biological apatite greatly depend on the properties of the crystals initially formed. As such, Fourier-transform infrared microspectroscopy (FTIRM) is capable of examining adaptive remodeling by providing compositional information such as the level of mineralization and carbonate substitution, as well as quality and perfection of the mineral phase. The objective of this study was to evaluate the in vitro mineralization development of MC3T3-E1 murine calvarial preosteoblasts cultured on different substrata by comparing FTIRM measurements from two subclones (mineralizing subclone 4 and nonmineralizing subclone 24) maintained in culture for up to 21 days. The results showed that modulation of the substrate surface using a thin coating of sulfonated polystyrene (SPS) provided favorable conditions for the development of a mineralizable ECM and that the mineral formed by the osteoblasts was similar to that of fully mineralized bone tissue. Specifically, the mineralizing subclone produced significantly more mineral phosphate when cultured on SPS-coated substrates for 21 days, compared to the same culture on bare substrates. In contrast, the level of mineralization in nonmineralizing subclone was low on both SPS-coated and uncoated substrates. The mineralizing subclone also produced comparable amounts of collagen on both substrates; however, mineralization was significantly higher in the SPS culture. The nonmineralizing subclone produced comparable amounts of collagen on day 1 but much less on day 21. Collagen maturity ratio increased in the mineralizing subclone from day 1 to day 21, but remained unchanged in the nonmineralizing subclone. In conclusion, these results suggest that SPS-treatment of the substrate surface may alter collagen remodeling; however, other factors may also influence osteoblast mineralization in the long term.

59 BASIC BIOLOGICAL SCIENCES↗

21 Tesla Fourier Transform Ion Cyclotron Resonance Mass Spectrometer Greatly Expands Mass Spectrometry Toolbox

We provide the initial performance evaluation of a 21 Tesla Fourier transform ion cyclotron resonance mass spectrometer operating at the Environmental Molecular Sciences Laboratory at Pacific Northwest National Laboratory. The spectrometer constructed for the 21T system employs a commercial dual linear ion trap mass spectrometer coupled to a FTICR spectrometer designed and built in-house. Performance gains from moving to higher magnetic field strength are exemplified by the measurement of peptide isotopic fine structure, complex natural organic matter mixtures, and large proteins. Accurate determination of isotopic fine structure was demonstrated for doubly charged substance P with minimal spectral averaging, and 8,158 molecular formulas assigned to Suwannee River Fulvic Acid standard with RMS error of 10 ppb. We also demonstrated superior performance for intact proteins; namely, broadband isotopic resolution of the entire charge state distribution of apotransferrin (78 kDa) and facile isotopic resolution of monoclonal antibody under a variety of acquisition parameters (e.g. 6 s time-domains with absorption mode processing yielded resolution of approximately 1M at m/z =2,700).

Environmental Molecular Sciences Laboratory↗

Fourier transform techniques for the inference of cloud motion

The development and evaluation are reported of phase shift techniques based on the Fourier transform for the estimation of cloud motion from geosynchronous meteorological satellite photographs. An alternative approach to cloud motion estimation, involving thresholding, was proposed and studied.

Lo, R. C.↗

Measurements of solar magnetic fields by Fourier transform techniques. I - Unsaturated lines

If the basic profile shapes of the normal Zeeman triplet do not have zeros in their Fourier transform, the magnetic field splitting can be determined independent of the profile shape. When the ratio of the splitting of the components is greater than the intrinsic FWHM of the component profiles, the magnetic splitting can be determined with significantly greater accuracy than the measurement accuracy of the original profile. For Gaussian shaped components and a ratio of magnetic splitting to FWHM of 1.5, the noise reduction factor is 25.

Title, A. M.↗

High resolution characterization of soil dissolved organic matter with FTICR-MS (Fourier-transform ion cyclotron resonance mass spectrometry) from soil samples in control and warming plots in Blodgett Forest, CA (2014 and 2018)

The pathways of carbon transport and loss through and from soils—soil organic matter (SOM) depolymerization to dissolved organic carbon and mineralization to carbon dioxide (CO2)—are fundamentally driven by microbial activity, which is strongly regulated by environmental conditions. As part of Lawrence Berkeley National Laboratory (LBNL) Terrestrial Ecosystem Science (TES) Belowground Biogeochemistry Science Focus Area (SFA), we have established a novel whole-soil long-term warming experiment at the University of California (UC) Blodgett Forest Research Station (Sierra Nevada) in 2014, where we study the role of biogeochemical, microbial and geochemical process interactions in SOM decomposition and stabilization.This package contains Fourier transform ion cyclotron resonance mass spectrometry (21 Tesla FTICR-MS) data measured in negative and positive ionization mode from water and methanol soil extracts. Soil samples were collected in 2014/06/03 and 2018/06/04 from 3 replicated paired plots that had been subjected to experimental warming since June 2014 to simulate a predicted climate change scenario for northern California. The following files are included: (1) fticr_neg_h2oMeoh_data_raw.csv: raw data from combined water (H2O) and methanol (MeOH) extracts in negative ion mode, (2) fticr_neg_h2oMeoh_data_processed.csv: processed data from combined water (H2O) and methanol (MeOH) extracts in negative ion mode, (3) fticr_neg_metadata.csv: metadata for samples/measurements in negative ion mode, (4) fticr_pos_h2oMeoh_data_raw.csv: raw data from combined water (H2O) and methanol (MeOH) extracts in positive ion mode, (5) fticr_pos_h2oMeoh_data_processed.csv: processed data from combined water (H2O) and methanol (MeOH) extracts in positive ion mode, (6) fticr_pos_metadata.csv: metadata for samples/measurements in positive ion mode.

54 ENVIRONMENTAL SCIENCES↗

Single beam Fourier transform digital holographic quantitative phase microscopy

Quantitative phase contrast microscopy reveals thickness or height information of a biological or technical micro-object under investigation. The information obtained from this process provides a means to study their dynamics. Digital holographic (DH) microscopy is one of the most used, state of the art single-shot quantitative techniques for three dimensional imaging of living cells. Conventional off axis DH microscopy directly provides phase contrast images of the objects. However, this process requires two separate beams and their ratio adjustment for high contrast interference fringes. Also the use of two separate beams may make the system more vulnerable to vibrations. Single beam techniques can overcome these hurdles while remaining compact as well. Here, we describe the development of a single beam DH microscope providing whole field imaging of micro-objects. A hologram of the magnified object projected on to a diffuser co-located with a pinhole is recorded with the use of a commercially available diode laser and an arrayed sensor. A Fourier transform of the recorded hologram directly yields the complex amplitude at the image plane. The method proposed was investigated using various phase objects. It was also used to image the dynamics of human red blood cells in which sub-micrometer level thickness variation were measurable.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Elasto-viscoplastic fast Fourier transform modeling framework for assessing microstructural effects on stress intensity factors characterizing fracture toughness

A large-strain elasto-viscoplastic fast Fourier transform (LS-EVPFFT) model with non-periodic (NP) velocity-based boundary conditions is adapted to simulate the sensitivity of stress intensity factors on microstructure for 304L stainless steel. The material was characterized via electron backscattered diffraction (EBSD) serial-sectioning to obtain a measured 3-D microstructural cell to perform simulations. The NP-LS-EVPFFT model, including the simulation setup and boundary conditions, was verified using a crystal plasticity finite element (CPFE) model. To this end, the generation of meshes of notched specimens was developed, which involved creating Python scripts for mesh “cutting” in Abaqus, and Sculpt scripts in Cubit for meshing of the measured microstructural cell processed with DREAM.3D. The complexity of the mesh preparation highlighted the advantages of the FFT-based model, which circumvents the mesh generation process. Given the efficiency of the FFT-based model, statistical distribution of stress intensity factors in function of crystal orientation at the crack tip, grain structure, and crystallographic texture surrounding the crack tip were predicted. Further, the distributions reveal about 10% variation of stress intensity factors with microstructure with the most significant sensitivity found to be the crystal orientation at the crack tip. The methodology developed in this work is discussed as a practical simulation tool for predicting the sensitivity of stress intensity factors on microstructural variability in metallic materials.

36 MATERIALS SCIENCE↗