Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ferry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Antarctic polar stratospheric aerosols: The roles of nitrates, chlorides and sulfates

Nitric and hydrochloric acids have been postulated to condense in the winter polar stratosphere to become an important component of polar stratospheric clouds. One implication is that the removal of NO(y) from the gas phase by this mechanism allows high Cl(x) concentrations to react with O3, because the formation of ClNO3 is inhibited. Contributions of NO3 and Cl to the stratospheric aerosol were determined during the 1987 Airborne Antarctic Ozone Experiment by testing for the presence of nitrates and chlorides in the condensed phase. Aerosol particles were collected on four 500 micron diameter gold wires, each pretreated differently to give results that were specific to certain physical and chemical aerosol properties. One wire was carbon-coated for concentration and size analyses by scanning electron microscopy; X-ray energy dispersive analyses permitted the detection of S and Cl in individual particles. Three more wires were coated with Nitron, barium chloride and silver nitrate, respectively, to detect nitrate, sulfate and chloride in aerosol particles. All three ions, viz., sulfates, nitrates and chlorides were detected in the Antarctic stratospheric aerosol. In terms of number concentrations, the aerosol was dominated by sulfates, followed by chlorides and nitrates. An inverse linear regression can be established between nitrate concentrations and ozone mixing ratio, and between temperature and nitrates.

Pueschel, R. F.↗

In-situ measurements of total reactive nitrogen, total water vapor, and aerosols in polar stratospheric clouds in the Antarctic stratosphere

Measurements of total reactive nitrogen, NOy, total water vapor, and aerosols were made as part of the Airborne Antarctic Ozone Experiment. The measurements were made using instruments located onboard the NASA ER-2 aircrafts which conducted twelve flights over the Antarctic continent reaching altitudes of 18 km at 72 S latitude. Each instrument utilized an ambient air sample and provided a measurement up to 1 Hz or every 200 m of flight path. The data presented focus on the flights of Aug. 17th and 18th during which Polar Stratospheric Clouds (PSCs) were encountered containing concentrations of 0.5 to 1.0 micron diameter aerosols greater than 1 cm/cu. The temperature pressure during these events ranged as low as 184 K near 75 mb pressure, with water values near 3.5 ppm by volume (ppmv). With the exception of two short periods, the PSC activity was observed at temperatures above the frost point of water over ice. The data gathered during these flights are analyzed and presented.

Fahey, D. W.↗

Extinction and backscatter measurements of Antarctic PSC's, 1987: Implications for particle and vapor removal

The temperature dependence is examined of optical properties measured in the Antarctic during 1987 at the 70 mb level (near 18 km), a level chosen to correlate the results with in situ measurements made from the NASA-Ames ER-2 aircraft during the 1987 Airborne Antarctic Ozone Experiment (AAOE). The data set consists of extinction measurements by Sam 2 inside the Antarctic polar vortex from May to October 1987; and backscatter measurements by the UV-DIAL (Ultraviolet Differential Absorption Lidar) system aboard the Ames DC-8 aircraft during selected AAOE flights. Observed trends are compared with results from a revised version of Pole and McCormick's model to classify the PSC observations by Type (1 or 2) and infer the temporal behavior of the ambient aerosol and ambient vapor mixing ratios. The sample figures show monthly ensembles of the 70-mb Sam 2 extinction ratio (the ratio of aerosol or PSC extinction to molecule extinction) as a function of NMC temperature at the beginning (June) and (October) of the 1987 Antarctic winter. Both ensembles show two rather distinct clusters of points: one oriented in the near vertical direction which depicts the change with temperature of the ambient aerosol extinction ratio; and a second cluster oriented in the near horizontal direction whose position on the vertical scale marks a change in particle phase (i.e., PSC formation) and whose length (the extinction enhancement related to that of the ambient aerosol) is an indicator of PSC type.

Poole, L. R.↗

Observations of condensation nuclei in the 1987 airborne Antarctic ozone experiment

The condensation nucleus counter (CNC) flown of the NASA ER-2 in the Airborne Antarctic Ozone Experiment provides a measurement of the number mixing ratio of particles which can be grown by exposure to supersaturated n-butyl alcohol vapor to diameters of a few microns. Such particles are referred to as condensation nuclei (CN). The ER-2 CNC was calibrated with aerosols of known size and concentration and was found to provide an accurate measure of the number concentration of particles larger than about 0.02 micron. Since the number distribution of stratospheric aerosols is usually dominated by particles less than a few tenths of micron in diameter, the upper cutoff of the ER-2 CNC has not been determined experimentally. However, theory suggests that the sampling and counting efficiency should remain near one for particles as large as 1 micron in diameter. Thus, the CN mixing ratio is usually a good measure of the mixing ratio of submicron particles.

Wilson, J. C.↗

Measurements of NO and total reactive odd-nitrogen, NOy, in the Antarctic stratosphere

Measurements of NO and total reactive N, NOy, were made as part of the Airborne Antarctic Ozone Experiment conducted in Punta Arenas, Chile during Aug. and Sept. 1987. The total reactive N reservoir includes the species NO, NO2, NO3, N2 O5, HNO3, and ClONO2. The instrument was located on board the NASA ER2 aircraft which conducted 12 flights over the Antarctic continent reaching altitudes of 18 km at 72 deg S latitude. The NOy technique utilized the conversion of component NOy species to NO on a gold catalyst and the subsequent detection of NO by the chemiluminescence reaction of NO with ozone. Since the inlet sample line is heated and the catalyst operates at 300 C, NOy incorporated in aerosols evaporates and is converted to NO. NO was measured on two separate flights by removing the catalyst from the sample inlet line.

Fahey, D. W.↗

Dehydration in the lower Antarctic stratosphere in late winter and spring

The history of minimum temperatures at 50 and 70 mb is examined from NMC, UK Met 0 and ECMWF analyses. MSU channel 24 data are similarly inspected. South Pole sonde data are used to calculate saturation humidity mixing ratio as a function of altitude and time throughout 1987. Saturation with respect to ice could be maintained for water mixing ratios of 3.5 ppmv for a period of about 80 days from mid-June to mid-September. Dehydration to mixing ratios of 1 ppmv or less was possible sporadically. Data from the ER-2 flights between 53 S and 72 S are used in conjunction with particle size measurements and air parcel trajectories to demonstrate the dehydration occurring over Antarctica. Water mixing ratios at the latitude of Punta Arenas (53 S), in conjunction with tracer measurements and trajectory analysis, show that at potential temperatures from about 325 to 400 K, the dryness (less than 3 ppmv) had its origin over Antarctica rather than in the tropics. Water mixing ratios within the Antarctic vortex varied from 1.5 to 3.8 ppmv, with a strong isentropic gradient being evident in the region of high potential vorticity gradients.

Kelly, K. K.↗

SAGE II aerosol validation - Selected altitude measurements, including particle micromeasurements

The validity of particulate extinction coefficients derived from limb path solar radiance measurements obtained during the Stratospheric Aerosol and Gas Experiment (SAGE) II is tested. The SAGE II measurements are compared with correlative aerosol measurements taken during January 1985, August 1985, and July 1986 with impactors, laser spectrometers, and filter samplers on a U-2 aircraft, an upward pointing lidar on a P-3 aircraft, and balloon-borne optical particle counters. The data for July 29, 1986 are discussed in detail. The aerosol measurements taken on this day at an altitude of 20.5 km produce particulate extinction values which validate the SAGE II values for similar wavelengths.

Oberbeck, Verne R.↗

Mineral catalysis of the formation of the phosphodiester bond in aqueous solution - The possible role of montmorillonite clays

The possible role of montmorillonite clays in the spontaneous formation on the primitive earth of the phosphodiester bond in the presence of water was investigated in experiments measuring the binding of various nucleosides and nucleotides with Na(+)-montmorillonite 22A and the reactions of these compounds with a water-soluble carbodiimide. It was found that, at neutral pH, adenine derivatives bind stronger than the corresponding uracil derivatives, consistent with the protonation of the adenine by the acidic clay surface and a cationic binding of the protonated ring to the anionic clay surface. The reaction of the 5-prime-AMP with carbodiimide resulted in the formation of 2-prime,5-prime-pApA (18.9 percent), 3-prime,5-prime-pApA (11 percent), and AppA (4.8 percent). The yields of these oligomers obtained when poly(U) was used in place of the clay were 15.5 percent, 3.7 percent, and 14.9 percent AppA, respectively.

Ferris, James P.↗

Condensed nitrate, sulfate, and chloride in Antarctic stratospheric aerosols

The 1987 Airborne Antarctic Ozone Experiment, in which the NO3, Cl, and SO4 contents of stratospheric aerosols were estimated, is discussed. The aerosol size and chemical composition measurements were carried out on samples collected during August 17 to September 4, 1987. The data indicate that condensed nitrate is found below a threshold temperature of 193.6 + or - 3.0 K, which is generally found at latitudes exceeding 64 deg S. A negative correlation exists between condensed nitrate and ozone correlation.

Pueschel, R. F.↗

Filter measurement results from the Airborne Antarctic Ozone Experiment

Filter samples obtained as part of the AAOE to determine the total nitrate, sulfate, acidic chloride, and acidic fluoride content along the flight path of the NASA ER-2 are studied. These compounds were obtained in the aerosol and vapor phase. The ratio of particulate sulfate observed outside the chemically perturbed region (CPR) of the vortex to that inside the CPR was 2.6. The ratio of total acidic chloride to total acidic flouride within the CPR is near 1, indicating the removal of chloride from the air mass or the partitioning of chloride into an unmeasured species.

Gandrud, B. W.↗

In situ measurements of total reactive nitrogen, total water, and aerosol in a Polar Stratospheric Cloud in the Antarctic

Measurements of total reactive nitrogen, NOy, total water vapor, and aerosols were made as part of the Airborne Antarctic Ozone Experiment. The measurements were made using instruments located onboard the NASA ER-2 aircrafts which conducted twelve flights over the Antarctic continent reaching altitudes of 18 km at 72 S latitude. Each instrument utilized an ambient air sample and provided a measurement up to 1 Hz or every 200 m of flight path. The data presented focus on the flights of Aug. 17th and 18th during which Polar Stratospheric Clouds (PSCs) were encountered containing concentrations of 0.5 to 1.0 micron diameter aerosols greater than 1 cm/cu. The temperature pressure during these events ranged as low as 184 K near 75 mb pressure, with water values near 3.5 ppm by volume (ppmv). With the exception of two short periods, the PSC activity was observed at temperatures above the frost point of water over ice. The data gathered during these flights are analyzed and presented.

Fahey, D. W.↗

Physical processes in polar stratospheric ice clouds

The formulation and evolution of polar stratospheric ice clouds are simulated using a one-dimensional model of cloud microphysics. It is found that the optical thickness and particle size of ice clouds depend on the cooling rate of the air in which the cloud formed. It is necessary that there be an energy barrier to ice nucleation upon the preexisting aerosols in order to account for the cooling rate dependence of the cloud properties.

Toon, Owen B.↗

Communication-Gateway Software For NETEX, DECnet, And TCP/IP

Communications gateway software, GATEWAY, provides process-to-process communication between remote applications programs in different protocol domains. Communicating peer processes may be resident on any paired combination of NETEX, DECnet, or TCP/IP hosts. Provides necessary mapping from one protocol to another and facilitates practical intermachine communications in cost-effective manner by eliminating need to standardize on single protocol or to implement multiple protocols in host computers. Written in Ada.

Keith, B.↗

A study of high-lift airfoils at high Reynolds numbers in the Langley low-turbulence pressure tunnel

An experimental study was conducted in the Langley Low Turbulence Pressure Tunnel to determine the effects of Reynolds number and Mach number on the two-dimensional aerodynamic performance of two supercritical type airfoils, one equipped with a conventional flap system and the other with an advanced high lift flap system. The conventional flap system consisted of a leading edge slat and a double slotted, trailing edge flap with a small chord vane and a large chord aft flap. The advanced flap system consisted of a leading edge slat and a double slotted, trailing edge flap with a large chord vane and a small chord aft flap. Both models were tested with all elements nested to form the cruise airfoil and with the leading edge slat and with a single or double slotted, trailing edge flap deflected to form the high lift airfoils. The experimental tests were conducted through a Reynolds number range from 2.8 to 20.9 x 1,000,000 and a Mach number range from 0.10 to 0.35. Lift and pitching moment data were obtained. Summaries of the test results obtained are presented and comparisons are made between the observed aerodynamic performance trends for both models. The results showing the effect of leading edge frost and glaze ice formation is given.

Morgan, Harry L., Jr.↗

Cryogenic balances for the US NTF

Force balances were used to obtain aerodynamic data in the National Transonic Facility (NTF) wind tunnel since it became operational in 1983. These balances were designed, fabricated, gaged, and calibrated to Langley Research Center's specifications to operate over the temperature range of -320 F to +140 F without thermal control. Some of the materials and procedures developed to obtain a balance that would perform in this environment are reviewed. The degree of success in using these balances thus far is reported. Some of the problem areas that need additional work are specified and some of the progress addressing these problems is described.

Ferris, Alice T.↗

Concentrations and size distributions of Antarctic stratospheric aerosols

Particle Measuring Systems laser particle spectrometer (ASAS-X and FSSP) probes were used to measure aerosol particle concentrations and size distributions during 11 ER-2 flights between Punta Arenas (53 deg S) and Antarctica (up to 72 deg S) from August 17 to September 22, 1987. The time resolution was 10 s, corresponding to a spatial resolution of 2 km. The data were divided into two size classes (0.05-0.25 and 0.53-5.5 micron radius) to separate the small particle from the coarse particle populations. Results show that the small-particle concentrations are typical for a background aerosol during volcanic quiescence. This concentration is generally constant along a flight track; in only one instance a depletion of small particles during a polar stratospheric cloud (PSC) encounter was measured, suggesting a nucleation of type I PSC particles on background aerosols. Temporary increases of the coarse particle concentrations indicated the presence of tenuous polar stratospheric clouds that were encountered most frequently at the southernmost portion of a flight track and when the aircraft descended to lower altitudes. During 'particle events', particle modes were found at 0.6-micron radius, corresponding to type I PSCs, and occasionally, at 2.0-micron radius corresponding to type II PSCs.

Ferry, G. V.↗

Measurements of nitric oxide and total reactive nitrogen in the Antarctic stratosphere - Observations and chemical implications

Results are presented on measurements of NO and the sum of reactive nitrogen species, NO(y), which include NO, NO2, NO3, N2O5, HNO3, and ClONO2 (in addition to ClO, O3, H2O, and N2O measurements), obtained aboard the NASA ER-2 aircraft flying over the Antarctica between the latitudes of 53 and 72 deg S during the Airborne Antarctic Ozone Experiment. The boundary of the chemically perturbed region (CPR), as indicated by a sharp increase in the level of ClO, occurred near 66 deg S; outside or equatorward of the CPR, the NO(y) mixing ratios ranged between 6 and 12 ppbv, with values decreasing poleward and reaching total NO(y) levels of 4 ppbv or less within 5-deg poleward of the boundary. Data presented in this paper clearly associate the Antarctic ozone decrease with perturbed conditions of ClO, NO(y), and H2O, which are in turn associated with processes defined as nonstandard heterogeneous chemistry, denitrification, and dehydration, respectively.

Fahey, D. W.↗

Measurements of condensation nuclei in the Airborne Arctic Stratospheric Expedition - Observations of particle production in the polar vortex

The ER-2 Condensation Nucleus Counter (ER-2 CNC) was operated in the Airborne Arctic Stratospheric Expedition (AASE) in January and February 1989. The ER-2 CNC measures the mixing ratio of particles, CN, with diameters from approximately 0.02 to approximately 1 micron. The spatial distribution of CN in the Arctic polar vortex was found to resemble that measured in the Antarctic in the Spring of 1987. The vertical profile of CN in the vortex was lowered by subsidence. At altitudes above the minimum in the CN mixing ratio profile, CN mixing ratios correlated negatively with that of N2O, demonstrating new particle production. CN serve as nuclei in the formation of Polar Stratospheric Clouds (PSCs) and the concentration of CN can affect PSC properties.

Wilson, J. C.↗