Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLUORESCENCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Red Fluorescent Line Emission from Hydrogen Molecules in Diffuse Molecular Clouds

We have modeled the fluorescent pumping of electronic and vibrational emissions of molecular hydrogen (H2) within diffuse molecular clouds that are illuminated by ultraviolet continuum radiation. Fluorescent line intensities are predicted for transitions at ultraviolet, infrared, and red visible wavelengths as functions of the gas density, the visual extinction through the cloud, and the intensity of the incident UV continuum radiation. The observed intensity in each fluorescent transition is roughly proportional to the integrated rate of H2 photodissociation along the line of sight. Although the most luminous fluorescent emissions detectable from ground-based observatories lie at near-infrared wavelengths, we argue that the lower sky brightness at visible wavelengths makes the red fluorescent transitions a particularly sensitive probe. Fabry-Perot spectrographs of the type that have been designed to observe very faint diffuse Ha emissions are soon expected to yield sensitivities that will be adequate to detect H2 vibrational emissions from molecular clouds that are exposed to ultraviolet radiation no stronger than the mean radiation field within the Galaxy. Observations of red H2 fluorescent emission together with cospatial 21 cm H I observations could serve as a valuable probe of the gas density in diffuse molecular clouds.

Neufeld, David A.↗

Foliar Reflectance and Fluorescence Responses for Corn and Soybean Plants Under Nitrogen Stress

We are investigating the use of spectral indices derived from actively induced fluorescence spectra and passive optical spectra. We examined the influence of photosynthetic pigment, carbon (C) and nitrogen (N) content on the spectral fluorescence and passive optical property characteristics of mature, upper leaves from plants provided different N fertilizer application rates: 20%, 50%, 100% and 150% of recommended N levels. A suite of optical, fluorescence, and biophysical measurements were collected on leaves from field grown corn (Zea mays L.) and soybean plants (Glycine max L.) grown in pots (greenhouse + ambient sunlight. Steady state laser-induced fluorescence emission spectra (5 nm resolution) were obtained from adaxial and abaxial surfaces resulting from excitation at single wavelengths (280, 380 or 360, and 532 nm). For emission spectra produced by each of these excitation wavelengths, ratios of emission peaks were calculated, including the red far-red chlorophyll fluorescence (ChlF) ratio (F685/F740) and the far-red/green (F740/F525) ratio. High resolution (< 3 nm) optical spectra (350-2500 nm) of reflectance, transmittance, and absorptance were also acquired for both adaxial and abaxial leaf surfaces. Species differences were demonstrated for several optical parameters. A 'red edge' derivative ratio determined from transmittance spectra [as the maximum first deivative, between 650-750 nm, normalized to the value at 744 nm, or Dmax/D744], was strongly associated with the C/N ratio (r(exp 2) = 0.90, P +/- 0.001). This ratio, calculated from reflectance spectra, was inversely related to chlorophyll b content (r(exp 2) = 0.91, P +/- 0.001) as was the ChlF (F685/F740) ratio obtained with 532 nm excitation (r(exp 2) = 0.76, P +/- 0.01). Discrimination of N treatment groups was possible with specific fluorescence band ratios (e.g., F740/F525 obtained with 380 nm excitation). Higher ChlF and blue-green emissions were measured from the abaxial leaf surfaces. Abaxial surfaces also produced higher reflectances, in general, in the 400-800 nm spectrum.

Middleton, E. M.↗

Two-Photon Fluorescence Microscope for Microgravity Research

A two-photon fluorescence microscope has been developed for the study of biophysical phenomena. Two-photon microscopy is a novel form of laser-based scanning microscopy that enables three-dimensional imaging without many of the problems inherent in confocal microscopy. Unlike one-photon optical microscopy, two-photon microscopy utilizes the simultaneous nonlinear absorption of two near-infrared photons. However, the efficiency of two-photon absorption is much lower than that of one-photon absorption, so an ultra-fast pulsed laser source is typically employed. On the other hand, the critical energy threshold for two-photon absorption leads to fluorophore excitation that is intrinsically localized to the focal volume. Consequently, two-photon microscopy enables optical sectioning and confocal performance without the need for a signal-limiting pinhole. In addition, there is a reduction (relative to one-photon optical microscopy) in photon-induced damage because of the longer excitation wavelength. This reduction is especially advantageous for in vivo studies. Relative to confocal microscopy, there is also a reduction in background fluorescence, and, because of a reduction in Rayleigh scattering, there is a 4 increase of penetration depth. The prohibitive cost of a commercial two-photon fluorescence-microscope system, as well as a need for modularity, has led to the construction of a custom-built system (see Figure 1). This system includes a coherent mode-locked titanium: sapphire laser emitting 120-fs-duration pulses at a repetition rate of 80 MHz. The pulsed laser has an average output power of 800 mW and a wavelength tuning range of 700 to 980 nm, enabling the excitation of a variety of targeted fluorophores. The output from the laser is attenuated, spatially filtered, and then directed into a confocal scanning head that has been modified to provide for side entry of the laser beam. The laser output coupler has been replaced with a dichroic filter that reflects the longer-wavelength excitation light and passes the shorter-wavelength fluorescence light. Also, the confocal pinhole has been removed to increase the signal strength. The laser beam is scanned by a twoperpendicular- axis pair of galvanometer mirrors through a pupil transfer lens into the side port of an inverted microscope. Finally, the beam is focused by a 63-magnification, 1.3-numerical- aperture oil-immersion objective lens onto a specimen. The pupil transfer lens serves to match the intermediate image planes of the scanning head and the microscope, and its location is critical. In order to maximize the quality of the image, (that is, the point spread function of the objective lens for all scan positions), the entire system was modeled in optical-design software, and the various free design parameters (the parameters of the spatial-filter components as well as the separations of all of the system components) were determined through an iterative optimization process. A modular design was chosen to facilitate access to the optical train for future fluorescence correlation spectroscopy and fluorescence-lifetime experiments.

Fischer, David G.↗

Spectral and Temporal Laser Fluorescence Analysis Such as for Natural Aquatic Environments

An Advanced Laser Fluorometer (ALF) can combine spectrally and temporally resolved measurements of laser-stimulated emission (LSE) for characterization of dissolved and particulate matter, including fluorescence constituents, in liquids. Spectral deconvolution (SDC) analysis of LSE spectral measurements can accurately retrieve information about individual fluorescent bands, such as can be attributed to chlorophyll-a (Chl-a), phycobiliprotein (PBP) pigments, or chromophoric dissolved organic matter (CDOM), among others. Improved physiological assessments of photosynthesizing organisms can use SDC analysis and temporal LSE measurements to assess variable fluorescence corrected for SDC-retrieved background fluorescence. Fluorescence assessments of Chl-a concentration based on LSE spectral measurements can be improved using photo-physiological information from temporal measurements. Quantitative assessments of PBP pigments, CDOM, and other fluorescent constituents, as well as basic structural characterizations of photosynthesizing populations, can be performed using SDC analysis of LSE spectral measurements.

Chekalyuk, Alexander↗

Particle Image Velocimetry Applications Using Fluorescent Dye-Doped Particles

Polystyrene latex sphere particles are widely used to seed flows for velocimetry techniques such as Particle Image Velocimetry (PIV) and Laser Doppler Velocimetry (LDV). These particles may be doped with fluorescent dyes such that signals spectrally shifted from the incident laser wavelength may be detected via Laser Induced Fluorescence (LIF). An attractive application of the LIF signal is achieving velocimetry in the presence of strong interference from laser scatter, opening up new research possibilities very near solid surfaces or at liquid/gas interfaces. Additionally, LIF signals can be used to tag different fluid streams to study mixing. While fluorescence-based PIV has been performed by many researchers for particles dispersed in water flows, the current work is among the first in applying the technique to micron-scale particles dispersed in a gas. A key requirement for such an application is addressing potential health hazards from fluorescent dyes; successful doping of Kiton Red 620 (KR620) has enabled the use of this relatively safe dye for fluorescence PIV for the first time. In this paper, basic applications proving the concept of PIV using the LIF signal from KR620-doped particles are exhibited for a free jet and a twophase flow apparatus. Results indicate that while the fluorescence PIV techniques are roughly 2 orders of magnitude weaker than Mie scattering, they provide a viable method for obtaining data in flow regions previously inaccessible via standard PIV. These techniques have the potential to also complement Mie scattering signals, for example in multi-stream and/or multi-phase experiments.

Petrosky, Brian J.↗

Scaling photosynthetic function and CO2 dynamics from leaf to canopy level for maize – dataset combining diurnal and seasonal measurements of vegetation fluorescence, reflectance and vegetation indices with canopy gross ecosystem productivity

Recent advances in leaf fluorescence measurements and canopy proximal remote sensing currently enable the non-destructive collection of rich diurnal and seasonal time series, which are required for monitoring vegetation function at the temporal and spatial scales relevant to the natural dynamics of photosynthesis. Remote sensing assessments of vegetation function have traditionally used actively excited foliar chlorophyll fluorescence measurements, canopy optical reflectance data and vegetation indices (VIs), and only recently passive solar induced chlorophyll fluorescence (SIF) measurements. In general, reflectance data are more sensitive to the seasonal variations in canopy chlorophyll content and foliar biomass, while fluorescence observations more closely relate to the dynamic changes in plant photosynthetic function. With this dataset we link leaf level actively excited chlorophyll fluorescence, canopy proximal reflectance and SIF, with eddy covariance measurements of gross ecosystem productivity (GEP). The dataset was collected during the 2017 growing season on maize, using three automated systems (i.e., Monitoring Pulse-Amplitude-Modulation fluorimeter, Moni-PAM; Fluorescence Box, FloX; and from eddy covariance tower). The data were quality checked, filtered and collated to a common 30 minutes timestep. We derived vegetation indices related to canopy functioning (e.g., Photochemical Reflectance Index, PRI; Normalized Difference Vegetation Index, NDVI; Chlorophyll Red-edge, Clre) to investigate how SIF and VIs can be coupled for monitoring vegetation photosynthesis. The raw datasets and the filtered and collated data are provided to enable new processing and analyses.

Petya Campbell↗

Fluorescence Behavior of Schiff Base-N, N′-bis(salicylidene) Trans 1, 2-Diaminocyclohexane in Proteinous and Micellar Environments

Fluorescence properties of N, N′-bis(salicylidene) trans 1, 2-diaminocyclohexane (H{sub 2}L) is used to probe the anionic (SDS), cationic (CTAB) and nonionic (TX-100) micelles as well as in serum albumins (BSA and HSA) and chicken egg white lysozyme (LYZ) by steady state and picosecond time-resolved fluorescence spectroscopy. The fluorescence band intensity was found to increase with concomitant blue-shift with gradual addition of different surfactants. All the experimental results suggest that the probe molecule resides in the micelle-water interface rather than going into the micellar core. However, the penetration is more towards the micellar hydrocarbon core in nonionic surfactant (TX-100) while comparing with ionic surfactants (SDS and CTAB). Several mean microscopic properties such as critical micelle concentration, polarity parameters and binding constant were calculated in presence of different surfactants. The decrease in nonradiative decay rate constants in micellar environments indicates restricted motion of the probe inside the micellar nanocages with increasing fluorescence emission intensity and quantum yields. Further in this work, we also investigated the interaction behavior of the probe with different proteins at low concentrations under physiological conditions (pH = 7.4). Stern–Volmer analysis of the tryptophan (Trp) fluorescence quenching data in presence of probe reveals Stern–Volmer constant (K{sub sv}) as well as bimolecular quenching rate constant (K{sub q}). The binding constant as well as the number of binding sites of the probe with proteins were also monitored and found to be 1:1 stoichiometry ratio.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spectroscopic and Theoretical Studies of Fluorescence Effects in 2-Methylamino-5-(2,4-dihydroxyphenyl)-1,3,4-thiadiazole Induced by Molecular Aggregation

The article presents the results of fluorescence analyses of 2-methylamino-5-(2,4-dihydroxyphenyl)-1,3,4-thiadiazole (MDFT) in an aqueous environment. MDFT dissolved in aqueous solutions with a pH value in the range from 1 to 4.5 yielded an interesting effect of two clearly separated fluorescence emissions. In turn, a single fluorescence was observed in MDFT dissolved in water solutions with a pH value from 4.5 to 12. As it was suggested in the previous investigations of other 1,3,4-thiadiazole compounds, these effects may be associated with conformational changes in the structure of the analysed molecule accompanied by aggregation effects. Crystallographic data showed that the effect of the two separated fluorescence emissions occurred in a conformation with the –OH group in the resorcyl ring bound on the side of the sulphur atom from the 1,3,4-thiadiazole ring. The hypothesis of aggregation as the mechanism involved in the change in the spectral properties at low pH is supported by the results of (Time-Dependent) Density Functional Theory calculations. The possibility of rapid analysis of conformational changes with the fluorescence spectroscopy technique may be rather important outcome obtained from the spectroscopic studies presented in this article. Additionally, the presented results seem to be highly important as they can be easily observed in solutions and biologically important samples.

74 ATOMIC AND MOLECULAR PHYSICS↗

A Dual-Target Fluorescent Probe with Response-Time Dependent Selectivity for Cd{sup 2+} and Cu{sup 2+}

A novel fluorescent probe (NT) was developed by merging 2-hydrazinylbenzothiazole with 2-hydroxy-1-naphthaldehyde for the detection of Cd{sup 2+} and Cu{sup 2+}. The probe alone is almost nonfluorescent due to the isomerization of C=N in the excited state. The addition of Cd{sup 2+} can cause an immediate strong green fluorescence owing to the suppression of C=N isomerization by Cd{sup 2+}-coordination. Furthermore, NT gives a delayed turn-on fluorescence response to Cu{sup 2+} although it is a vigorous fluorescence quencher, which was thanks to the inhibition of the electron transfer between excited fluorophore and paramagnetic Cu{sup 2+} by sulfur donor. Based on fluorescence spectra and ESI-MS analysis, the binding modes between NT and Cd{sup 2+}/Cu{sup 2+} were proposed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Hyper-mobility of water around actin filaments revealed using pulse-field gradient spin-echo {sup 1}H NMR and fluorescence spectroscopy

Research highlights: {yields} Translationally hyper-mobile water has been detected around actin filaments. {yields} Translationally hyper-mobile water is formed upon polymerization of actin. {yields} Low water viscosity was found around F-actin using fluorescence anisotropy. {yields} Formation of hyper-mobile water may explain endothermic actin polymerization. -- Abstract: This paper reports that water molecules around F-actin, a polymerized form of actin, are more mobile than those around G-actin or in bulk water. A measurement using pulse-field gradient spin-echo {sup 1}H NMR showed that the self-diffusion coefficient of water in aqueous F-actin solution increased with actin concentration by {approx}5%, whereas that in G-actin solution was close to that of pure water. This indicates that an F-actin/water interaction is responsible for the high self-diffusion of water. The local viscosity around actin was also investigated by fluorescence measurements of Cy3, a fluorescent dye, conjugated to Cys 374 of actin. The steady-state fluorescence anisotropy of Cy3 attached to F-actin was 0.270, which was lower than that for G-actin, 0.334. Taking into account the fluorescence lifetimes of the Cy3 bound to actin, their rotational correlation times were estimated to be 3.8 and 9.1 ns for F- and G-actin, respectively. This indicates that Cy3 bound to F-actin rotates more freely than that bound to G-actin, and therefore the local water viscosity is lower around F-actin than around G-actin.

60 APPLIED LIFE SCIENCES↗

In situ analysis of elemental depth distributions in thin films by combined evaluation of synchrotron x-ray fluorescence and diffraction

In this work we present a method for the in situ analysis of elemental depth distributions in thin films using a combined evaluation of synchrotron x-ray fluorescence and energy-dispersive x-ray diffraction signals. We recorded diffraction and fluorescence signals simultaneously during the reactive annealing of thin films. By means of the observed diffraction signals, the time evolution of phases in the thin films during the annealing processes can be determined. We utilized this phase information to parameterize the depth distributions of the elements in the films. The time-dependent fluorescence signals were then taken to determine the parameters representing the parameterized depth distributions. For this latter step, we numerically calculated the fluorescence intensities for a given set of depth distributions. These calculations handle polychromatic excitation and arbitrary functions of depth distributions and take into account primary and secondary fluorescence. Influences of lateral non-uniformities of the films, as well as the accuracy limits of the method, are investigated. We apply the introduced method to analyze the evolution of elemental depth distributions and to quantify the kinetic parameters during a synthesis process of CuInS{sub 2} thin films via the reactive annealing of Cu-In precursors in a sulfur atmosphere.

36 MATERIALS SCIENCE↗

Design and evaluation of a device for fast multispectral time-resolved fluorescence spectroscopy and imaging

The application of time-resolved fluorescence spectroscopy (TRFS) to in vivo tissue diagnosis requires a method for fast acquisition of fluorescence decay profiles in multiple spectral bands. This study focusses on development of a clinically compatible fiber-optic based multispectral TRFS (ms-TRFS) system together with validation of its accuracy and precision for fluorescence lifetime measurements. It also presents the expansion of this technique into an imaging spectroscopy method. A tandem array of dichroic beamsplitters and filters was used to record TRFS decay profiles at four distinct spectral bands where biological tissue typically presents fluorescence emission maxima, namely, 390, 452, 542, and 629 nm. Each emission channel was temporally separated by using transmission delays through 200 μm diameter multimode optical fibers of 1, 10, 19, and 28 m lengths. A Laguerre-expansion deconvolution algorithm was used to compensate for modal dispersion inherent to large diameter optical fibers and the finite bandwidth of detectors and digitizers. The system was found to be highly efficient and fast requiring a few nano-Joule of laser pulse energy and <1 ms per point measurement, respectively, for the detection of tissue autofluorescent components. Organic and biological chromophores with lifetimes that spanned a 0.8–7 ns range were used for system validation, and the measured lifetimes from the organic fluorophores deviated by less than 10% from values reported in the literature. Multi-spectral lifetime images of organic dye solutions contained in glass capillary tubes were recorded by raster scanning the single fiber probe in a 2D plane to validate the system as an imaging tool. The lifetime measurement variability was measured indicating that the system provides reproducible results with a standard deviation smaller than 50 ps. The ms-TRFS is a compact apparatus that makes possible the fast, accurate, and precise multispectral time-resolved fluorescence lifetime measurements of low quantum efficiency sub-nanosecond fluorophores.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectrally resolved fluorescence diffuse tomography of biological tissues

Spectrally resolved fluorescence diffuse tomography (SFDT) is demonstrated to be an effective approach to the reconstruction of the fluorescent agent distribution in biological tissues. Analysis of the measured optical power spectrum enables more accurate fluorophore localisation in solving the inverse tomography problem, because the dispersion of the optical parameters of the imaging subject leads to characteristic changes in the shape of its fluorescence spectrum. The SFDT system built by us includes a common optical fibre output of light sources and a single fibre input of the detector in an on-axis configuration, and an electromechanical scanner. The system enables studies of laboratory animals having tumours labelled with various fluorescent agents (fluorescent proteins, quantum dots and others). The first in vivo experiments have demonstrated the feasibility of tumour detection and localisation in laboratory animals by SFDT. (optical tomography)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Speckle spectroscopy of fluorescent randomly inhomogeneous media

We propose a coherence optical method for probing fluorescent randomly inhomogeneous media based on the statistical analysis of spatial fluctuations of spectrally selected fluorescence radiation. We develop a phenomenological model that interrelates the flicker index of the spatial distribution of the fluorescence intensity at a fixed wavelength and the mean path difference of partial components of the fluorescence radiation field in the probed medium. The results of experimental approbation of the developed method using the layers of densely packed silicon dioxide particles saturated with the aqueous rhodamine 6G solution with a high concentration of the dye are presented. The experimentally observed significant decrease in the flicker index under the wavelength tuning from the edges of the fluorescence spectrum towards it central part is presumably a manifestation of spectrally dependent negative absorption in the medium. (speckle spectroscopy)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Biomimetic tissue phantoms for neurosurgical near-infrared fluorescence imaging

Neurosurgical fluorescence imaging is a well-established clinical approach with a growing range of indications for use. However, this technology lacks effective phantom-based tools for development, performance testing, and clinician training. Our primary aim was to develop and evaluate 3D-printed phantoms capable of optically and morphologically simulating neurovasculature under fluorescence angiography. Volumetric digital maps of the circle of Willis with basilar and posterior communicator artery aneurysms, along with surrounding cerebral tissue, were generated. Phantoms were fabricated with a stereolithography printer using custom photopolymer composites, then visualized under white light and near-infrared fluorescence imaging. Feature sizes of printed components were found to be within 13% of digital models. Phantoms exhibited realistic optical properties and convincingly recapitulated fluorescence angiography scenes. Methods identified in this study can facilitate the development of realistic phantoms as powerful new tools for fluorescence imaging.

3D modeling↗

An Experimental Study of the Fluorescence Spectrum of Cesium Atoms in the Presence of a Buffer Gas

A direct experiment is performed to determine the quantum efficiency of a cesium fluorescence filter. The fluorescence spectra of cesium atoms are recorded under excitation of the upper states of the second resonance doublet with a Bell–Bloom cesium lamp. Introduction of different noble gases into the cell with cesium leads to the appearance of additional fluorescence photons. It is found that a fluorescence filter based on atomic cesium vapor with addition of helium in the working cell has the highest efficiency and response rate of all known fluorescence filters based on alkali-metal atomic vapors.

74 ATOMIC AND MOLECULAR PHYSICS↗

Calculation of Transfer Functions of Multilayer Biotissues in the Problems of Correction of Their Fluorescence Spectra

A method for rapid calculation of a flux of stimulated fluorescence of a multilayer optically dense medium with inhomogeneous distribution of the fluorophore has been developed. The light field in the medium at the excitation wavelength of fluorescence is represented by a superposition of incident collimated, incident diffuse, and reflected diffuse fluxes. A two-stream approximation is used to describe the light field in the medium at the wavelength of emission of the fluorescence. Fluxes in adjacent elementary layers of the medium and on its surface are connected by simple matrix operators that are obtained using a combination of engineering approaches of radiation-transfer theory and single-scattering approximation. The calculations of fluorescence fluxes of a four-layer biotissue that are excited and recorded at 400–800 nm are compared with their Monte Carlo simulation with a discrepancy of 1%. The effect of the propagation medium on the fluorescence spectra of 5-ALA-induced protoporphyrin IX that are recorded from human skin was studied, and a technique for their correction that is based on measurements and quantitative analysis of the diffuse reflectance spectrum of skin was proposed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Two-component molecular tagging velocimetry utilizing NO fluorescence lifetime and NO2 photodissociation techniques in an underexpanded jet flowfield

We report the application of molecular tagging velocimetry (MTV) toward two-component velocimetry as demonstrated in an underexpanded free jet flowfield. Two variants of the MTV technique are presented: 1) electronic excitation of seeded nitric oxide (NO) with gated fluorescence imaging (fluorescence lifetime) and 2) photodissociation of seeded NO2 followed by NO fluorescence imaging (NO2 photodissociation). The seeded NO fluorescence lifetime technique is advantageous in low-quenching, high-velocity flowfields, while the photodissociation technique is useful in high-quenching environments, and either high- or low-velocity flowfields due to long lifetime of the NO photoproduct. Both techniques are viable for single-shot measurements, with determined root mean squared results for streamwise and radial velocities of {approx}5%. This study represents the first known application of MTV utilizing either the fluorescence lifetime or the photodissociation technique toward two-component velocity mapping in a gaseous flowfield. Methods for increasing the spatial resolution to be comparable to particle-based tracking techniques are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗