Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Environmental control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Environmental controls on the kinetics of iron-sulfur cluster nucleation and nanoparticle formation

Anoxic, sulfidic conditions have been prevalent since the early Proterozoic and favor aqueous iron-sulfur (FeS aq ) clusters as a major fraction of the soluble, reduced iron and sulfur pool. FeS aq cluster formation and nucleation is driven by the high affinity between ferrous iron (Fe(II)) and sulfide (HS − ), ultimately yielding particles that precipitate as iron sulfide minerals. FeS aq clusters were recently shown to be bioavailable sources of iron and sulfur for a variety of anaerobes, yet little is known of the factors that influence the kinetics of their formation and nucleation. Here we apply computational and spectroscopic approaches to investigate the dynamics of FeS aq nucleation, cluster growth, precipitation, and redissolution as a function of Fe(II)/HS − concentration, temperature, and pH. Experiments were conducted under excess HS − to mimic euxinic conditions common to contemporary anaerobic aquatic ecosystems and those of the Proterozoic. Density functional theory calculations reveal the key role of water oxygen-iron interactions in stabilizing small FeS aq clusters and promoting solubility. Dynamic light scattering revealed a concentration-dependent increase in the kinetics of FeS aq nucleation and cluster aggregation. Increasing temperature promoted FeS aq cluster nucleation and aggregation while also enhancing dissolution. Alkaline pH also promoted FeS aq nucleation and cluster aggregation. At 25 °C, pH 7.0, and at reactant concentrations of 30 µM, FeS aq clusters < 10 nm in diameter remained in solution for > 2 h. These results underscore the importance of temperature, pH, and reactant concentration in the kinetics of FeS aq nucleation and cluster growth that, in turn, influence their bioavailability in anaerobic ecosystems.

Aquatic ecosystems↗

Micro-environmental control for efficient local cooling

Micro-environment is hereby defined as the air space and environment around a person that directly impacts his/her thermal sensation. Most existing HVAC systems condition the air of the entire room including the unoccupied space, which leaves a big potential to save energy. This study aims at evaluating the performance of three existing air terminal devices (ATDs) to locally remove enough heat from the micro-environment to manage the thermal balance so as not to sacrifice thermal comfort when the ambient unoccupied space temperature is increased by 2.2 °C from 23.9 °C to 26.1 °C in the summer to reduce the external cooling load. A computational fluid dynamics (CFD) model was developed, validated by full-scale chamber tests and applied to evaluate different configurations of the ATDs for local cooling. Results show that the predicted performance agreed well with the measurements, and the selected ATD, with only 50 W cooling power, was always able to remove a sufficient amount of heat from the microenvironment in a room of raised temperature, when the manikin was moved inside a semicircle movement range. The cooling performance of the jet was increased more by increasing the supply air flow rate than reducing the supply temperature and was highly dependent on the shooting angle. Finally, the heat flux from the manikin surface is very sensitive to the surface temperature and furniture placement, and proper specification of the surface temperature is crucial for the CFD simulation to match the measured results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Micro-environmental control for efficient local heating: CFD simulation and manikin test verification

Micro-environment control system has been proved to be able to provide local thermal comfort control. It also has the potential to save building energy by relaxing the control on the unoccupied space. This work aims at designing an efficient heating delivering device (HDD) to locally warm the person to restore thermal comfort when the unoccupied space temperature is reduced from 70.0 °F to 66.0 °F to save the energy. A three-stage approach was developed for designing the HDD including the initial stage of developing by CFD simulation, the second stage of manikin test verification and final stage of human subject test confirmation. The results of the first two stages were presented and discussed in this work. It was shown that convective heating was not efficient enough unless a confinement box was used to hold the hot air around the legs and feet. A more ergonomically friendly design of using a foot warmer was finally proved to be a better solution for individually heating by both simulation and experiments since it can heat the occupant sufficiently. The ability of using CFD to predict heat loss from the clothed human body and its limitation was also investigated. It was found that with proper clothing insulation, the CFD can give a reasonable prediction, although simulating the clothing as a layer of certain thermal resistance might be problematic regarding the structure and permeability of the clothing material. In conclusion, a more appropriate method for simulating the clothing was needed for better prediction in the future.

42 ENGINEERING↗

Permanent Foam Fixatives for Radioactive Contamination Control: Environmental Chamber Testing

The Department of Energy (DOE) Office of Environmental Management (EM) is tasked with closing cleanup sites throughout the DOE-EM complex. A major component of successfully closing the sites is the deactivation and decommissioning (D&D) of radioactively contaminated buildings in nuclear facilities. Deactivation consists of the process of placing a contaminated facility in stable condition in order to minimize any risks that could affect workers, the public, and the environment. Successful deactivation and decommissioning consists of leaving the buildings in an agreed upon end state to provide future protection against hazards. Hazards include radiation but can also include asbestos, polychlorinated biphenyls, and other environmental and physical hazards.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

KBase Narrative - Genomic and environmental controls on Castellaniella biogeography in an anthropogenically disturbed site

Genome assemblies were imported into KBase using the Batch Import Assembly from Staging Area (v1.0.57) function. All assemblies were annotated using the Annotated Multiple Microbial Assemblies with RASTtk - v1.073 tool. Annotated genomes were grouped into sets using the Add Genomes to GenomeSet - v1.7.6 function. Individual annotated genomes can be found both below and in the Data menu to the left. Taxonomy was assigned using the Classify Microbes with GTDB-Tk-v1.7.0 tool. The results of this analysis are shown below. Analysis of the Castellaniella pangenome was performed using the Compute Pangenome (v0.0.7) tool. Using the same method, we also computed the ORR-specific and non-ORR Castellaniella pangenomes. All pangenome results (including the presence/absence matrix) can be found below.

Szink, Elizabeth↗

Prediction of gas leakage of environmental control systems

Mathematical models of leakage configurations and various flow theories are presented with the substantive experimental test data to provide background material for future design and failure analysis. Normal-rate leakage and emergency, high-rate leakage are considered.

Jackson, J. K.↗