Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy Simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

A method to generate heating and cooling schedules based on data from connected thermostats

Internet-connected thermostats are a promising new source of temperature and operational data in homes because they record inside temperatures, setpoints, and HVAC runtimes every five minutes. Over 20 million Internet-connected thermostats have already been installed in American homes. Data from about 20,000 connected thermostats were collected and organized by climate zone, number of occupants, floor area, and day type. A method was developed to create up to 40 representative temperature schedules which, together, can more accurately capture the diversity of heating and cooling behaviors. These results are suitable for input into schedules for building energy simulation models. This information enables more realistic simulations of American heating and cooling behavior, leading to more accurate estimates of energy consumption and savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Savings Analysis of the Proposed NYStretch-Energy Code 2018

This study was conducted by the Pacific Northwest National Laboratory (PNNL) in support of the stretch energy code development led by the New York State Energy Research and Development Authority (NYSERDA). In 2017 NYSERDA developed its 2016 Stretch Code Supplement to the 2016 New York State Energy Conservation Construction Code (hereinafter referred to as “NYStretch-Energy”). NYStretch-Energy is intended as a model energy code for statewide voluntary adoption that anticipates other code advancements culminating in the goal of a statewide Net Zero Energy Code by 2028. Since then, NYSERDA continues to develop the NYStretch-Energy Code 2018 edition. To support the effort, PNNL conducted energy simulation analysis to quantify the energy savings of proposed commercial provisions of the NYStretch-Energy Code (2018) in New York. The focus of this project is the 20% improvement over existing commercial model energy codes. A key requirement of the proposed stretch code is that it be ‘adoptable’ as an energy code, meaning that it must align with current code scope and limitations, and primarily impact building components that are currently regulated by local building departments. It is largely limited to prescriptive measures, which are what most building departments and design projects are most familiar with. This report describes a set of energy-efficiency measures (EEMs) that demonstrate 20% energy savings over ANSI/ASHRAE/IES Standard 90.1-2013 (ASHRAE 2013) across a broad range of commercial building types and all three climate zones in New York. In collaboration with New Building Institute, the EEMs were developed from national model codes and standards, high-performance building codes and standards, regional energy codes, and measures being proposed as part of the on-going code development process. PNNL analyzed these measures using whole building energy models for selected prototype commercial buildings and multifamily buildings representing buildings in New York. Section 2 of this report describes the analysis methodology, including the building types and construction area weights update for this analysis, the baseline, and the method to conduct the energy saving analysis. Section 3 provides detailed specifications of the EEMs and bundles. Section 4 summarizes the results of individual EEMs and EEM bundles by building type, energy end-use and climate zone. Appendix A documents detailed descriptions of the selected prototype buildings. Appendix B provides energy end-use breakdown results by building type for both the baseline code and stretch code in all climate zones.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Final Energy Savings Analysis of the Proposed NYStretch-Energy Code 2018

This study was conducted by the Pacific Northwest National Laboratory (PNNL) in support of the stretch energy code development led by the New York State Energy Research and Development Authority (NYSERDA). In 2017 NYSERDA developed its 2016 Stretch Code Supplement to the 2016 New York State Energy Conservation Construction Code (hereinafter referred to as “NYStretch-Energy”). NYStretch-Energy is intended as a model energy code for statewide voluntary adoption that anticipates other code advancements culminating in the goal of a statewide Net Zero Energy Code by 2028. Since then, NYSERDA continues to develop the NYStretch-Energy Code 2018 edition (NYSERDA 2018). To support the effort, PNNL conducted energy simulation analysis to quantify the energy savings of proposed commercial provisions of the NYStretch-Energy Code 2018 in New York. The focus of this project is to significantly improve the energy efficiency over existing commercial model energy codes. A key requirement of the proposed stretch code is that it be ‘adoptable’ as an energy code, meaning that it must align with current code scope and limitations, and primarily impact building components that are currently regulated by local building departments. It is largely limited to prescriptive measures, which are what most building departments and design projects are most familiar with. This report describes a set of energy-efficiency measures (EEMs) that demonstrate significant energy savings over ANSI/ASHRAE/IES Standard 90.1-2013 (ASHRAE 2013) across a broad range of commercial building types and all three climate zones in New York. In collaboration with New Building Institute, the EEMs were developed from national model codes and standards, high-performance building codes and standards, regional energy codes, and measures being proposed as part of the on-going code development process. PNNL analyzed these measures using whole building energy models for selected prototype commercial buildings and multifamily buildings representing buildings in New York.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

2015 IECC: Energy Savings Analysis

Section 304(a) of the Energy Conservation and Production Act, as amended, requires the Secretary of Energy to make a determination each time a revised edition of the 1992 Model Energy Code (MEC), or any successor thereof, is published with respect to whether the revised code would improve energy efficiency in residential buildings. The International Energy Conservation Code (IECC), as administered by the International Code Council (ICC), establishes the national model code for energy efficiency requirements for residential buildings. The latest edition of the IECC, the 2015 IECC, was published on June 3, 2014 and forms the basis of this analysis. To meet these statutory requirements, as well as to assist states and adopting entities in understanding associated savings, the DOE Building Energy Codes Program and Pacific Northwest National Laboratory (PNNL) conduct analyses to evaluate the differences between the latest edition of the IECC and its immediate predecessor. A qualitative analysis is conducted, identifying all changes made to the previous edition of the IECC, and characterizing these changes in terms of their anticipated impact on residential building energy consumption. A quantitative analysis is then modeled through building energy simulation to estimate the resulting energy impacts. This report documents the technical analysis used to evaluate whether residential buildings constructed to meet the requirements of the 2015 IECC would result in energy efficiency improvements over residential buildings constructed to meet the requirements of the previous edition, the 2012 IECC. PNNL considered all code change proposals approved for inclusion in the 2015 IECC during the ICC code development cycle, and evaluated their combined impact on a suite of prototypical residential building energy models across all U.S. climate zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Scenario Documentation: Chiller Replacement

Building on a 3-year effort to calibrate and validate the U.S. Department of Energy's ResStock (TM) and ComStock (TM) models, this work produces national datasets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual energy consumption (at a subhourly resolution) of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. The goal of this work is to develop energy efficiency and demand flexibility end-use load shapes that cover high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to various "what-if" scenarios that can be applied to buildings. An end-use savings shape is the difference in energy consumption between a baseline building (or collection of buildings) and a building with an energy efficiency or demand flexibility measure applied. It results in a time-series profile broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step, as well as annual aggregations. This report describes the modeling methodology for a single end-use savings shape measure - chiller replacement - and briefly introduces key results. The full public dataset can be accessed on the ComStock (TM) data lake or via the Data Viewer at comstock.nrel.gov. The public data set enables users to create custom aggregations of results for their use case (e.g., filter to a specific county).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Scenario Documentation: Standard Performance Heat Pump Rooftop Unit With New Windows

Building on a 3-year effort to calibrate and validate the U.S. Department of Energy's ResStock (TM) and ComStock (TM) models, this work produces national datasets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual energy consumption (at subhourly resolution) of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. The goal of this work is to develop energy efficiency and demand flexibility end-use load shapes that cover high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to various "what-if" scenarios that can be applied to buildings. An end-use savings shape is the difference in energy consumption between a baseline building (or collection of buildings) and a building with an energy efficiency or demand flexibility measure applied. It results in a time-series profile broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step, as well as annual aggregations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Medium- and Heavy-Duty Truck Duty Cycles

This dataset provides second-by-second duty cycle data for Class 6 and Class 8 diesel trucks in Texas, including key vehicle metrics, engine-related data, and GPS data (excluding GPS latitude and longitude to ensure confidentiality). The data were collected via tablets installed on the trucks and organized into daily datasets, each associated with a unique vehicle ID and date. There are 12 daily datasets for Class 6 diesel trucks (three unique vehicle IDs) and 43 daily datasets for Class 8 diesel trucks (six unique vehicle IDs). The units associated with each column are included in the name. The engine performance data include columns such as engine speed, engine percent torque, and engine fuel rate. Road grade (%/100) was estimated using the GPS altitude and wheel-based vehicle speed, which is used as an input for FASTSim. Cumulative distance was also calculated using the wheel-based vehicle speed. Additional columns include: - Engine Speed (RPM): Removed inaccurate readings and used to calculate angular velocity (radians/second). - Torque (N·m): Calculated using engine percent torque, nominal friction percent torque, and engine reference torque values (those columns were removed from dataset), then normalized to express as torque (%). - Flywheel Power (%): Calculated using the angular velocity and torque (in kW), then normalized as a percentage of the maximum value. - Engine Fuel Rate (%) and Torque (%): Both metrics were normalized by dividing by their respective maximum values within each dataset to express them as percentages. The datasets were analyzed to assess the energy impact of various driving behaviors, simulate energy efficiency, and recommend optimal routes for diesel trucks using NLR’s tool called RouteE. For driver coaching, factors like speed and acceleration limits were considered, and idle periods were reduced (assuming the engine was off during idling) to adjust each drive cycle. These adjusted drive cycles were then simulated in FASTSim to evaluate their effect on fleet energy consumption and estimate potential energy savings. The original cycles are available for download on this page ![image](CoVaR_Image_for_Data_Page_Kenworth_Truck.jpg)

1Hz↗

Effects of electron-phonon coupling and electronic thermal conductivity in high energy molecular dynamics simulations of irradiation cascades in nickel

The two-temperature model has been applied to investigate the effects of the electronic subsystem on 150 keV Ni ion cascades in nickel using molecular dynamics simulation. We explore the effects of the magnitude of the electron-phonon coupling and the electronic thermal conductivity on defect production and cluster formation. It has been found that stronger electron-phonon coupling allows larger and more rapid energy feedback to the atomic subsystem, leading to reduction of number of point defects and suppression of the formation of larger defect clusters. It was observed that larger electronic thermal conductivity results in slightly increased number of point defects and larger size vacancy clusters. The latter takes place because of suppression of point defects recombination in faster cooling areas of initial damage.

Zarkadoula, Eva↗

Validating Simulated Models of Energy Consumption by a Battery Electric Motorcoach: A real-world deployment in a harsh climate.

Many efforts have been made to simulate energy consumption of battery electric buses (BEBs) to optimize their deployment into existing fleets. The models produced, however, are rarely validated against real-world consumption data, limiting their generalizability and widespread application to fleets around the US. Furthermore, a major concern specific to BEBs is the effects of harsh climates on their performance. We build upon the state-of-the-art energy consumption modeling techniques developed for BEBs and apply them to a unique geographic context and a unique electrified vehicle. This geography, climate, and vehicle further the existing understanding of the factors affecting medium- and heavy-duty electric vehicles (MHDEVs) by allowing for new relationships to be tested and by assessing the generalizability of known relationships to new contexts. We find that temperature is less predictive of energy consumption for the battery electric motorcoach (BEM) in the case study environment than it is for BEBs in other studies. A mitigating factor that we presume to be working on the relationship between temperature and energy consumption is the fact that the BEM route does not stop between origin and destination to exchange passengers, and in turn, conditioned cabin air. Our model also incorporates wind speed and direction relative to travel, which is a novel contribution of our methodology. Results from our study are helpful for transit service planners, fleet operators, and logistics firms for improving their ability to predict performance of potential deployments of MHDEVs into existing operations.

32 - ENERGY CONSERVATION, CONSUMPTION, AND UTILIZA↗

Simulation of radiation energy release in air showers

A simulation study of the energy released by extensive air showers in the form of MHz radiation is performed using the CoREAS simulation code. We develop an efficient method to extract this radiation energy from air-shower simulations. We determine the longitudinal profile of the radiation energy release and compare it to the longitudinal profile of the energy deposit by the electromagnetic component of the air shower. We find that the radiation energy corrected for the geometric dependence of the geomagnetic emission scales quadratically with the energy in the electromagnetic component of the air shower with a second-order dependence on the atmospheric density at the position of the maximum shower development X {sub max}. In a measurement where X {sub max} is not accessible, this second order dependence can be approximated using the zenith angle of the incoming direction of the air shower with only a minor loss in accuracy. Our method results in an intrinsic uncertainty of 4% in the determination of the energy in the electromagnetic air-shower component, which is well below current experimental uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improving Air-Conditioner and Heat Pump Modeling (Presentation made at the Building America Stakeholders Meeting) [Slides]

A new approach to modeling residential air conditioners and heat pumps allows users to model systems by specifying only the more readily-available SEER/EER/HSPF-type metrics. Manufacturer data was used to generate full sets of model inputs for over 450 heat pumps and air conditioners. A sensitivity analysis identified which inputs can be safely defaulted 'behind-the-scenes' without negatively impacting the reliability of energy simulations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Verification and Validation of EnergyPlus Phase Change Material Model for Opaque Wall Assemblies

Phase change materials (PCMs) represent a technology that may reduce peak loads and HVAC energy consumption in buildings. A few building energy simulation programs have the capability to simulate PCMs, but their accuracy has not been completely tested. This study shows the procedure used to verify and validate the PCM model in EnergyPlus using a similar approach as dictated by ASHRAE Standard 140, which consists of analytical verification, comparative testing, and empirical validation. This process was valuable, as two bugs were identified and fixed in the PCM model, and version 7.1 of EnergyPlus will have a validated PCM model. Preliminary results using whole-building energy analysis show that careful analysis should be done when designing PCMs in homes, as their thermal performance depends on several variables such as PCM properties and location in the building envelope.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Online Tool for Preliminary Design and Techno-Economic Analysis of District Geothermal Heating and Cooling Systems

District geothermal heating and cooling systems (DGHCS) have significant benefits for reducing energy consumption as well as building- and grid-level peak electric demand. Currently, no publicly available tools are available to effectively design and conduct techno-economic analysis of DGHCS. GeoWISE was originally developed for preliminary design and techno-economic analysis of geothermal heating and cooling systems in an individual commercial or residential building. This paper introduces recent upgrades of GeoWISE that allow users to design and conduct techno-economic analysis of DGHCS. Several new features are implemented in GeoWISE to allow selection and specification of multiple new or existing buildings. A database of information for over 125 million existing U.S. buildings was used in GeoWISE that allows users easily locate existing buildings of interest based on street addresses, and optionally edit information of the buildings (e.g., footprint, vintage, principal functions, number of floors, window-to-wall ratio). Unique energy simulation models of the selected buildings are then automatically created using the Automatic Building Energy Modeling (AutoBEM) and EnergyPlus simulations are performed to predict thermal loads of the buildings. A simplified DGHCS is then designed and simulated to predict its energy use. A central borehole heat exchanger (BHE) of the DGHCS is sized using the RowWise algorithm of GHEDesigner to meet the thermal loads within user-specified land areas for installing BHE. The upgraded GeoWISE reports the needed capacity of heating and cooling equipment in each building, design of the central BHE, energy consumption reduction, and energy cost saving resulting from using DGHCS compared with conventional HVAC systems. A case study is showcased using the upgraded GeoWISE to design and conduct techno-economic analysis of a simplified DGHCS.

Prem Anand Jayaprabha, Jyothis Anand [ORNL] (ORCID↗

ComStock Measure Documentation: High-Efficiency Rooftop Unit

Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models, this work produces national data sets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The "baseline" model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass adoption impact on the baseline building stock. "Measures" refers to various "what-if" scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public data sets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario - high-efficiency rooftop unit (RTU) - and briefly introduces key results. The full public data set can be accessed on the Comstock data lake or via the Data Viewer at comstock.nlr.gov. The public data set enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Documentation: Variable-Speed Pumps

Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models, this work produces national data sets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The "baseline" model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass adoption impact on the baseline building stock. "Measures" refers to various "what-if" scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public data sets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario - variable speed pumps - and briefly introduces key results. The full public data set can be accessed on the ComStock data lake or via the Data Viewer at comstock.nlr.gov. The public data set enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Computing and Simulation

Designing and developing a framework for nuclear energy simulation is challenging because of the technical complexity of the task and the wide range of desired capabilities and possible approaches. During the course of this project, the NEAMS CT team has systematically studied a range of framework requirements and capabilities as documented in several reports. This work focused primarily on the SHARP and Salome frameworks. We are now carrying out a more detailed survey of additional framework parts and requirements. Based on this work, we expect to make a specific framework plan by about the end of 2010 and then to expand our effort to develop and integrate the various parts of such a framework. In addition, EDF and IBM have worked to optimize Code_Saturne for Blue Gene/P. We have significantly improved the performance of the code, introduced OpenMP parallelization which will be important for future HPC architectures with more cores, and solved a problem with over 1 billion mesh cells.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Regression-based approach to modeling emerging HVAC technologies in EnergyPlus: A case study using a Vuilleumier-cycle heat pump

This paper presents a regression-based approach for modeling emerging heating, ventilation, and air-conditioning (HVAC) technologies using the user-defined coil object in the building simulation software EnergyPlus. The approach can use output from HVAC system models or experimental data to create regression-based performance curves, which are then used within the building simulation. The regression approach is an alternative to modeling new HVAC technologies directly in EnergyPlus or performing co-simulation with a system model in a separate program. The proposed approach connects component and system level designs, and their associated performance, with annual energy use and costs in a variety of climates. This study focused on a Vuilleumier-cycle heat pump for a commercial building. We describe (1) the design and modeling of this system, (2) methods for translating this performance into a simplified model in EnergyPlus, and (3) building energy simulation results in United States climate zones 4-6. The results predict that the Vuilleumier-cycle heat pump will use 34 to 44% less source heating energy than an 80% efficient gas furnace, and more source cooling energy than a SEER 13 air conditioner. Total energy costs are lower when electricity prices are high and natural gas prices are low.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Upgrade Package Documentation: Wall and Roof Insulation and New Windows

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on an upgrade package of three end-use savings shapes upgrades - Window Replacement, Exterior Wall Insulation, and Roof Insulation, which we will refer to collectively as the "High Efficiency Envelope" package. More details on the individual upgrades can be found on the ComStock Measures Documentation page. An upgrade package applies two or more EUSS upgrades to a single building model simulation. Since ComStock is a bottom-up physics-based model, an upgrade package will go beyond aggregating or summing the individual upgrade results and produce novel results by simulating interactions between the upgrades. For example, pairing an envelope upgrade with an electrification upgrade would likely result in higher savings results than the sum of these upgrades individually, and the size of the heating, ventilating, and air conditioning (HVAC) equipment may be reduced if the envelope upgrade reduces the loads significantly.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗