Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electronic Procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Laser-field-induced surface-hopping method for the simulation and control of ultrafast photodynamics

We present the semiclassical laser-field-induced surface-hopping method for the simulation and control of coupled electron-nuclear dynamics in complex molecular systems including all degrees of freedom. Our approach is based on the Wigner representation of quantum mechanics. The combination of the molecular dynamics 'on the fly' employing quantum initial conditions with the surface-hopping procedure allows for the treatment of the electronic transitions induced by the laser field. Our semiclassical approach reproduced accurately exact quantum dynamics in a two-electronic-state model system. We demonstrate the scope of our method on the example of the optimal pump-dump control of the trans-cis isomerization of a prototypical Schiff base molecular switch. Our results show that selective photochemistry can be achieved by shaped laser pulses which open new dynamical pathways by suppressing the isomerization through the conical intersections between electronic states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Enhancement factor of nuclear reactions in partially ionized plasmas and asymmetric mixtures

When hydrogen is mixed with heavy (high‐ Z ) elements, even as traces, such as iron in the sun, the plasma mixture transits from a weakly coupled state to the intermediate coupling regime of simultaneous weak and strong couplings due to charge asymmetry. In those circumstances, partial ionization is an important aspect to consider. We present a global approach for evaluating enhancement factors for thermonuclear reactions in such mixtures. We grounded our approach on extensive orbital free molecular dynamics (OFMD) simulations of hydrogen‐silver mixtures, chosen as a prototype of hydrogen—high‐ Z mixtures, in a large range of temperature (100 < T < 1600 eV). By comparing a series of OFMD simulations to hyper‐netted chain calculations of effective binary ionic mixtures (eBIM), we set a general procedure for computing enhancement factors. The electron screening contribution is also included implicitly in the definition of the effective ionizations within the average atom framework. The agreement between the pair distribution functions of OFMD and eBIM validates a prescription in which each average atom representing a given species shares the same external electron density with the others (iso‐ n e rule). We checked that an interpolation formula between weak and strong couplings in BIM, due to Chugunov and DeWitt, is accurate enough to address the limit of extreme dilution of a heavy element.

Arnault, Philippe↗

Restenosis Rates After Drug-Eluting Stent Treatment for Stenotic Small-Diameter Renal Arteries

Purpose: To determine primary rates in small-diameter renal arteries, including complex bifurcation lesions, treated with drug-eluting stents (DES) in patients with atherosclerotic renal artery stenosis. Materials and Methods: This is a retrospective single-institution study. A total of 37 patients with 39 stented renal arteries were included. Patient and procedural data were obtained from the electronic medical record. Survival free from restenosis was estimated using the Kaplan–Meier method with patients stratified into two groups based on renal artery diameters (≤ 3.5 mm or > 3.5 mm). Univariate Cox proportional models were used to estimate hazard ratios associated with clinical and angiographic variables. Results: Average renal artery diameter at time of treatment was 3.4 mm ± 0.4 mm. The median survival free from restenosis was 992 days, with 11 out of 37 (29.7%) developing an in-stent restenosis. Renal arteries < 3.5 mm in diameter had similar patency rates as renal arteries > 3.5 mm (P = 0.33). The 1-, 2-, and 5-year patency rates were 71%, 63%, and 38%, respectively. History of stroke was the only comorbidity to portend a significantly greater rate of restenosis (hazard ratio 3.77; 95%CI, 1.05–13.6; P = 0.04). Medications did not statistically alter the risk of restenosis. Conclusion: Revascularization of renal arteries with DES achieved similar primary patency rates irrespective of renal artery diameter. Stent configuration was not associated with time to renal replacement therapy or all-cause mortality. Level of Evidence: Level 3, Cohort Study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transmission Kikuchi diffraction and transmission electron forescatter imaging of electropolished and FIB manufactured TEM specimens

We present a study of the efficiency of the utility of scanning electron microscope (SEM)-based transmission methods for characterizing grain structure in thinned bulk metals. Foils of type 316 stainless steel were prepared by two methods commonly used for transmission electron microscopy — double-jet electropolishing and focused ion beam milling. A customized holder allowed positioning of the foils in a configuration appropriate for both transmission electron forward scatter diffraction, and for transmission imaging by the use of a forescatter detector with two diodes. We found that both crystallographic orientation maps and dark-field transmitted images could be obtained for specimens prepared by either method. However, for both methods, preparation-induced artifacts may affect the quality or accuracy of transmission SEM data, especially those acquired by the use of transmission Kikuchi diffraction. Generally, the quality of orientation data was better for specimens prepared by electropolishing, due to the absence of ion-induced damage. - Highlights: • The transmission imaging and diffraction techniques are emerging in scanning electron microscopy (SEM) as promising new field of materials characterization. • The manuscript titled: “Transmission Kikuchi Diffraction and Transmission Electron Forescatter Imaging of Electropolished and FIB Manufactured TEM Specimens” documents how different specimen thinning procedures can effect efficiency of transmission Kikuchi diffraction and transmission electron forescatter imaging. • The abilities to make precision crystallographic orientation maps and dark-field images in transmission was studied on electropolished versus focus ion beam manufactured TEM specimens. • Depending on the need, electropolished and focused ion beam technique may produce suitable specimens for transmission imaging and diffraction in SEM.

36 MATERIALS SCIENCE↗

Effective Inclusion of Mechanical and Electrical Anharmonicity in Excited Electronic States: VPT2-TDDFT Route

Here, we present a reliable and cost-effective procedure for the inclusion of anharmonic effects in excited-state energies and spectroscopic intensities by means of second-order vibrational perturbation theory. This development is made possible thanks to a recent efficient implementation of excited-state analytic Hessians and properties within the time-dependent density functional theory framework. As illustrated in this work, by taking advantage of such algorithmic developments, it is possible to perform calculations of excited-state infrared spectra of medium-large isolated molecular systems, with anharmonicity effects included in both the energy and property surfaces. We also explore the use of this procedure for the inclusion of anharmonic effects in the simulation of vibronic bandshapes of electronic spectra, and compare the results with previous, more approximate models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spontaneous and reversible hollowing of alloy anode nanocrystals for stable battery cycling

High-capacity alloy anode materials for Li-ion batteries have long been held back by limited cyclability caused by the large volume changes during lithium insertion and removal. Hollow and yolk-shell nanostructures have been used to increase the cycling stability by providing an inner void space to accommodate volume changes and a mechanically and dimensionally stable outer surface. These materials, however, require complex synthesis procedures. Here, using in situ transmission electron microscopy, we show that sufficiently small antimony nanocrystals spontaneously form uniform voids on the removal of lithium, which are then reversibly filled and vacated during cycling. This behaviour is found to arise from a resilient native oxide layer that allows for an initial expansion during lithiation but mechanically prevents shrinkage as antimony forms voids during delithiation. In this work, we developed a chemomechanical model that explains these observations, and we demonstrate that this behaviour is size dependent. Thus, antimony naturally evolves to form optimal nanostructures for alloy anodes, as we show through electrochemical experiments in a half-cell configuration in which 15-nm antimony nanocrystals have a consistently higher Coulombic efficiency than larger nanoparticles.

25 ENERGY STORAGE↗

Improved AlphaFold modeling with implicit experimental information

Machine-learning prediction algorithms such as AlphaFold and RoseTTAFold can create remarkably accurate protein models, but these models usually have some regions that are predicted with low confidence or poor accuracy. We hypothesized that by implicitly including new experimental information such as a density map, a greater portion of a model could be predicted accurately, and that this might synergistically improve parts of the model that were not fully addressed by either machine learning or experiment alone. An iterative procedure was developed in which AlphaFold models are automatically rebuilt on the basis of experimental density maps and the rebuilt models are used as templates in new AlphaFold predictions. We show that including experimental information improves prediction beyond the improvement obtained with simple rebuilding guided by the experimental data. This procedure for AlphaFold modeling with density has been incorporated into an automated procedure for interpretation of crystallographic and electron cryo-microscopy maps.

59 BASIC BIOLOGICAL SCIENCES↗

Sub-10 nm nano-gap device for single-cluster transport measurements

We present a versatile procedure for the fabrication of single electron transistor (SET) devices with nanometer-sized clusters and embedded back gate electrode. The process uses sputtering gas-aggregation for the growth of clusters and e-beam lithography with double angle shadow-edge deposition to obtain electrodes separated by nano-gaps with width below 10 nm. The nano-gap width is easily controlled only by geometrical factors such as deposited thin film thickness and evaporation angles. The usefulness of this technique is demonstrated by measuring the SET behavior of a device with a 4 nm cobalt cluster embedded in alumina, where the Coulomb blockade and incremental cluster charging can be readily identified without resorting to the differential conductivity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Resonance strength measurement at astrophysical energies: The {sup 17}O(p,α){sup 14}N reaction studied via Trojan Horse Method

In recent years, the Trojan Horse Method (THM) has been used to investigate the low-energy cross sections of proton-induced reactions on {sup 17}O nuclei, overcoming extrapolation procedures and enhancement effects due to electron screening. We will report on the indirect study of the {sup 17}O(p,α){sup 14}N reaction via the THM by applying the approach developed for extracting the resonance strength of narrow resonance in the ultralow energy region. Two measurements will be described and the experimental THM cross sections will be shown for both experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

THE RGB AND AGB STAR NUCLEOSYNTHESIS IN LIGHT OF THE RECENT {sup 17}O(p, {alpha}){sup 14}N AND {sup 18}O(p, {alpha}){sup 15}N REACTION-RATE DETERMINATIONS

In recent years, the Trojan Horse Method (THM) has been used to investigate the low-energy cross sections of proton-induced reactions on A = 17 and A = 18 oxygen isotopes, overcoming extrapolation procedures and enhancement effects due to electron screening. In particular, the strengths of the 20 keV and 65 keV resonances in the {sup 18}O(p, {alpha}){sup 15}N and {sup 17}O(p, {alpha}){sup 14}N reactions, respectively, have been extracted, as well as the contribution of the tail of the broad 656 keV resonance in the {sup 18}O(p, {alpha}){sup 15}N reaction inside the Gamow window. The strength of the 65 keV resonance in the {sup 17}O(p, {alpha}){sup 14}N reaction, measured by means of the THM, has been used to renormalize the corresponding resonance strength in the {sup 17}O + p radiative capture channel. As a result, more accurate reaction rates for the {sup 18}O(p, {alpha}){sup 15}N, {sup 17}O(p, {alpha}){sup 14}N, and {sup 17}O(p, {gamma}){sup 18}F processes have been deduced, devoid of systematic errors due to extrapolation or the electron screening effect. Such rates have been introduced into state-of-the-art red giant branch and asymptotic giant branch (AGB) models for proton-capture nucleosynthesis coupled with extra-mixing episodes. The predicted abundances have been compared with isotopic compositions provided by geochemical analysis of presolar grains. As a result, an improved agreement is found between the models and the isotopic mix of oxide grains of AGB origins, whose composition is the signature of low-temperature proton-capture nucleosynthesis. The low {sup 14}N/{sup 15}N found in SiC grains cannot be explained by the revised nuclear reaction rates and remains a serious problem that has not been satisfactorily addressed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radioactive source calibration test of the CMS Hadron Endcap Calorimeter test wedge with Phase I upgrade electronics

The Phase I upgrade of the CMS Hadron Endcap Calorimeters consists of new photodetectors (Silicon Photomultipliers in place of Hybrid Photo-Diodes) and front-end electronics. The upgrade will eliminate the noise and the calibration drift of the Hybrid Photo-Diodes and enable the mitigation of the radiation damage of the scintillators and the wavelength shifting fibers with a larger spectral acceptance of the Silicon Photomultipliers. The upgrade also includes increased longitudinal segmentation of the calorimeter readout, which allows pile-up mitigation and recalibration due to depth-dependent radiation damage. As a realistic operational test, the responses of the Hadron Endcap Calorimeter wedges were calibrated with a $^{60}$Co radioactive source with upgrade electronics. The test successfully established the procedure for future source calibrations of the Hadron Endcap Calorimeters. Lastly we describe the instrumentation details and the operational experiences related to the sourcing test.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Unveiling the underlying interactions in Ta 2 NiSe 5 from photoinduced lifetime change

We present a generic procedure for quantifying the interplay of electronic and lattice degrees of freedom in photodoped insulators through a comparative analysis of theoretical many-body simulations and time- and angle-resolved photoemission spectroscopy (TR-ARPES) of the transient response of the candidate excitonic insulator Ta 2 NiSe 5 . Our analysis demonstrates that the electron-electron interactions dominate the electron-phonon ones. In particular, a detailed analysis of the TR-ARPES spectrum enables a clear separation of the dominant broadening (electronic lifetime) effects from the much smaller band-gap renormalization. Theoretical calculations show that the observed strong spectral broadening arises from the electronic scattering of the photoexcited particle-hole pairs and cannot be accounted for in a model in which electron-phonon interactions are dominant. The competing interactions were quantified using the scaling analysis in the weak fluence regime. We demonstrate that the magnitude of the weaker subdominant band-gap renormalization sensitively depends on the distance from the semiconductor/semimetal transition in the high-temperature state, which could explain the apparent contradictions between various TR-ARPES experiments. The analysis presented here indicates that electron-electron interactions play a vital role (albeit not the sole one) in stabilizing the insulating state, and establishes the comparison between lifetime and gap evolution as an important probe of correlated insulators.

36 MATERIALS SCIENCE↗

Time-Projection Chamber Development for the Multi-Purpose Detector in the NICA Project

Within the framework of the scientific program for the study of hot and dense nuclear matter in the Veksler and Baldin Laboratory of High Energy Physics of the Joint Institute of Nuclear Research, Dubna (JINR), the NICA megaproject (Nuclotron-based Ion Collider fAcility) based on the Nuclotron-M accelerator is implemented. The new accelerator facility will make it possible to research the properties of dense baryonic matter in the collision of heavy ions in a wide range of atomic masses from p – p collisions in the energy range √ S{sub pp} = 12–27 GeV/ n and d + d collisions with energies of √ S{sub NN} = 4–13.8 GeV/n with the average luminosity L = 10{sup 32} cm{sup –2} s{sup –1} up to Au{sup +79} + Au{sup +79} collisions in the energy range √S{sub NN} = 4–11 GeV/n with the average luminosity L = 10{sup 27} cm{sup –2} s{sup –1} (Au{sup +79}). A collider provides two points of intersection of beams, in one of which the multipurpose detector (Multi-Purpose Detector, MPD) will be installed. The time-projection gas chamber (TPC) is the main tracking detector and the particle identifier of the Multi-Purpose Detector. The article considers the structure of the MPD, the design and the main working parameters of TPC and its subsystems. The front-end electronics (FEE), as well as the procedure for assembling and integrating the TPC into the MPD are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electromagnetic compatibility design guideline for STADAN

Procedures for achieving electromagnetic compatibility in electronic and electrical equipment for aerospace ground stations are investigated. The application of shielding theory to good design is treated and standards of good practice are outlined for bonding, grounding, wiring, and cabling. Some aspects of filter design are explained, and suggestions are given for the application of filters to electronic and electrical equipment.

Cowdell, R. B.↗

Discrimination of gravitational stimuli

The construction and installation of an animal centrifuge and its electronic support system was completed. Experimental procedures for obtaining data on the relationship between the discriminability of g differences and location along the continuum of effective weight were initiated. Data were obtained under two successive discriminations showing discrimination among g levels. In addition, there was some indication that the discriminability of differences between g levels associated with reinforcement was the same at two locations along the g continuum, although there were differences in measures of absolute discrimination at these locations.

Clark, F. C.↗

Metallurgical evaluation of factors influencing the ductility of aged T-111

The metallurgical factors influencing the ductility of T-111 (Ta-8W-2Hf) alloy following long-time exposures of GTA welds and tubing in the temperature range 982 C (1800 F) through 1316 C (2400 F) were evaluated by means of scanning and transmission electron microscopy, Auger electron emission spectroscopy, and optical metallographic procedures. No classical aging response occurs in the alloy over the temperature range studied. The ductility impairment implied by previous investigations is not the result of microstructural response of the alloy to thermal exposures. Intergranular failure in the GTA sheet welds appears the result of random contamination by silicon, potassium, and/or fluorine at the grain boundaries of the fusion zones. Exposure to lithium at high temperatures had no adverse effects on the ductility of T-111 tubing. These materials were, however, sensitive to post-age handling and testing procedures.

Gold, R. E.↗

Test evaluation of the Sperry laser gyro model ASLG 15

Various parameters were evaluated such as bias, scale factor, scale factor sensitivity to supply voltage and external temperature, and turn-on trends. Photographs and descriptions of test equipment are given, and test procedures are outlined. A systems description (electronic equipment, block diagrams), performance characteristics, and equipment specifications of the laser gyro model are given. Also considered are the laser beam optics (laser mode locking). Results are reported for the various parameters examined, and recommendations given.

Source record↗

Discrepancies between theoretical and empirical models of the flaring solar chromosphere and their possible resolution

Possible sources of pronounced discrepancy between empirical and theoretical models of the solar chromosphere during flares are discussed. It is noted that a principal source of uncertainty in empirical models is the inhomogeneity of the spectral data on which they are based. With theoretical models, probably the most important source of error is neglect of the radiative coupling of upper and lower chromospheric regions. A new procedure for studying flare energy input is suggested wherein the required input is derived from the empirical model chromosphere. This procedure is applied to the electron-heated case, and it is found that the integral equation defining the flare energy deposition rate can be inverted analytically to yield the injected electron flux energy spectrum from knowledge of the energy balance in the empirical atmosphere. Recent empirical model results are analyzed in this manner, and the calculated injected electron flux spectrum is compared with that needed for hard X-ray bursts in moderately large flares.

Emslie, A. G.↗