Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electron cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Survey Of Cooling Techniques

Methods of maintaining electronics at best operating temperatures reviewed. Paper surveys cooling techniques for electronic components and sensors that must be kept at temperatures ranging from thousandths of kelvin to room temperature. Discusses characteristics of various coolers in terms of ground and space applications, cooling capacity, reliability, and temperature range. Also discusses briefly, cooling of conventional electronic circuitry operating few degrees above environmental temperature by natural or forced convection of air or liquid. At greater length, discusses passive and active refrigeration of "cold" electronic circuitry operating below environmental temperature.

Chan, Chung K.↗

Space Station Radiator Test Hosted by NASA Lewis at Plum Brook Station

In April of 1997, the NASA Lewis Research Center hosted the testing of the photovoltaic thermal radiator that is to be launched in 1999 as part of flight 4A of the International Space Station. The tests were conducted by Lockheed Martin Vought Systems of Dallas, who built the radiator. This radiator, and three more like it, will be used to cool the electronic system and power storage batteries for the space station's solar power system. Three of the four units will also be used early on to cool the service module.

Speth, Randall C.↗

Three Canted Radiator Panels to Provide Adequate Cooling for Instruments on Slewing Spacecraft in LEO

Certain free-flying spacecraft in low Earth orbit (LEO) or payloads on the International Space Station (ISS) are required to slew to point the telescopes at targets. Instrument detectors and electronics require cooling. Traditionally a planar thermal radiator is used. The temperature of such a radiator varies significantly when the spacecraft slews because its view factors to space vary significantly. Also for payloads on the ISS, solar impingement on the radiator is possible. These thermal adversities could lead to inadequate cooling for the instrument. This paper presents a novel thermal design concept that utilizes three canted radiator panels to mitigate this problem. It increases the overall radiator view factor to cold space and reduces the overall solar or albedo flux absorbed per unit area of the radiator.

Choi, Michael K.↗

Four K refrigerators with a new compact heat exchanger

Two refrigerators have been developed which have nominal cpacities of 0.25M and 0.5W at 4.2K. These use standard two stage Displex sup R expanders and compressors combined with a new compact heat exchanger which is concentric with the expander cylinder. These refrigerators can be used to cool superconducting electronic devices by direct attachment to the 4K heat station, or they can be plugged into the neck of a liquid helium superconducting magnet cryostat where they can cool the radiation shields and reliquefy helium.

Longsworth, R. C.↗

X-15 conditioning and pressurization system

The cooling system for the X-15 airplane incorporates insulation partial protection against high-temperature effects plus liquid and gaseous nitrogen to control specifically environmental and equipment temperatures. Electronic-equipment cooling represents the largest load; however, other items to be considered are the pressure-suit ventilation, aerodynamic-heating effects, sensor-head cooling, and windshield antifogging. A review of various types of cooling systems indicates that an expendable, stored, cooling system is the most efficient for short-duration missions. This paper presents a description including a simplified schematic diagram of the subject system. (author)

Bouman, C P↗

Alpha particle channeling in ITER

Alpha particle channeling, the attempt to extract energy from high-energy fusion alpha particles using a combination of high- and low-frequency waves introduced in the plasma with antennae, is studied using a guiding center code. We examine the effect of the combination of cooling caused by a cyclotron mode, particle diffusion due to Alfvén modes introduced for ash removal, the inclusion of microturbulent diffusion, and the slowing down of the alpha particles on electrons. Induced cooling is achieved with a cyclotron resonance, producing additional losses of particles above 3.5 MeV in an amount about equal to the prompt loss. The removal of the low-energy cooled particles by additional modes or by microturbulent diffusion is the hardest challenge for alpha channeling. The cooled alpha particles remain deep in the plasma center, so for this removal, the method used must be capable of providing transport from the plasma center to the edge without also causing losses of high-energy particles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evolution of electron and proton temperatures in a flaring loop. I - A case of thermal heating of electrons

A temperature difference between electrons and protons produced in a flaring loop was investigated experimentally by adopting a one-fluid, two-temperature model instead of a single-temperature model. Consideration was given to the case in which flare energy is released in the form of heating of electrons located in the top part of the loop. In this case, a large temperature difference appears in the corona in the energy-input phase of the flare. When the material evaporated from the chromosphere fills the corona, the temperature difference in the loop begins to shrink rapidly from below. Eventually, in the loop apex, the proton temperature exceeds the electron temperature mainly due to cooling of the electrons by conduction down the loop and heating of the protons by compression of the ascending material. In the late phase of the flare (about 15 min from the flare onset), the temperature difference becomes less than 2 pct of the mean temperature of electrons and protons at every point in the loop.

Nagai, F.↗

Mars Pathfinder mechanically pumped cooling loop

A mechanically pumped single-phase cooling loop was successfully flown on the Mars Pathfinder (MPF) Spacecraft which safely landed on the Martian surface on July 4, 1997. One of the key technologies that enabled the mission to succeed was an active heat rejection system (HRS) used to cool the electronics on the spacecraft during its seven-month cruise from Earth to Mars.

spacecraft tehermal control pumped cooling loop↗

Ultrafast thermal modification of strong coupling in an organic microcavity

There is growing interest in using strongly coupled organic microcavities to tune molecular dynamics, including the electronic and vibrational properties of molecules. However, very little attention has been paid to the utility of cavity polaritons as sensors for out-of-equilibrium phenomena, including thermal excitations. Here, we demonstrate that non-resonant infrared excitation of an organic microcavity system induces a transient response in the visible spectral range near the cavity polariton resonances. We show how these optical responses can be understood in terms of ultrafast heating of electrons in the metal cavity mirror, which modifies the effective refractive index and subsequently the strong coupling conditions. The temporal dynamics of the microcavity are strictly determined by carriers in the metal, including the cooling of electrons via electron–phonon coupling and excitation of propagating coherent acoustic modes in the lattice. We rule out multiphoton excitation processes and verify that no real polariton population exists despite their strong transient features. These results suggest the cavity polaritons to be promising as sensitive probes of non-equilibrium phenomena.

36 MATERIALS SCIENCE↗

Effectiveness-weighted control of cooling system components

Energy efficient control of cooling system cooling of an electronic system is provided based, in part, on weighted cooling effectiveness of the components. The control includes automatically determining speed control settings for multiple adjustable cooling components of the cooling system. The automatically determining is based, at least in part, on weighted cooling effectiveness of the components of the cooling system, and the determining operates to limit power consumption of at least the cooling system, while ensuring that a target temperature associated with at least one of the cooling system or the electronic system is within a desired range by provisioning, based on the weighted cooling effectiveness, a desired target temperature change among the multiple adjustable cooling components of the cooling system. The provisioning includes provisioning applied power to the multiple adjustable cooling components via, at least in part, the determined control settings.

42 ENGINEERING↗

Effectiveness-weighted control of cooling system components

Energy efficient control of cooling system cooling of an electronic system is provided based, in part, on weighted cooling effectiveness of the components. The control includes automatically determining speed control settings for multiple adjustable cooling components of the cooling system. The automatically determining is based, at least in part, on weighted cooling effectiveness of the components of the cooling system, and the determining operates to limit power consumption of at least the cooling system, while ensuring that a target temperature associated with at least one of the cooling system or the electronic system is within a desired range by provisioning, based on the weighted cooling effectiveness, a desired target temperature change among the multiple adjustable cooling components of the cooling system. The provisioning includes provisioning applied power to the multiple adjustable cooling components via, at least in part, the determined control settings.

Campbell, Levi A.↗

Wet/Dry Vacuum Cleaner

Vacuum cleaner collects and retains dust, wet debris, and liquids. Designed for housekeeping on Space Station Freedom, it functions equally well in normal Earth Gravity or in microgravity. Generates acoustic noise at comfortably low levels and includes circuitry that reduces electromagnetic interference to other electronic equipment. Draws materials into bag made of hydrophobic sheet with layers of hydrophilic super-absorbing pads at downstream end material. Hydrophilic material can gel many times its own weight of liquid. Blower also provides secondary airflow to cool its electronic components.

Reimers, Harold↗

Polytropic relationship in interplanetary magnetic clouds

High time-resolution data from the ISEE 3 and IMP 8 spacecraft are presented for the magnetic field and the proton and electron populations of a number of magnetic clouds, in order to investigate such clouds' thermodynamics and the relationship between their magnetic and thermodynamic structures. It is judged on the basis of these data that while the magnetic flield of the cloud expands, the ions are cooled. Hot electrons are trapped by the magnetic field in the magnetic cloud's core. These conditions are favorable for the generation of ion-acoustic waves.

Osherovich, V. A.↗

Thermal Gradient Effects on Redox Evolution and Volatility-Driven Fractionation in Ternary U/Ce/Cs Condensates

Understanding how thermal history influences redox evolution and chemical fractionation is essential for characterizing high-temperature condensation in complex materials, including nuclear debris. Here, we tested the hypothesis that distinct thermal regimes in a plasma flow reactor influence redox pathways and elemental partitioning in ternary U/Ce/Cs systems. A configurable plasma flow reactor was modified with an external tube furnace to impose two distinct thermal gradients: continuous ambient cooling and a furnace-assisted thermal hold-up near 1400 K followed by rapid cooling. Transmission electron microscopy characterized phase identity, morphology, and nanoscale element distributions, while inductively coupled plasma-mass spectrometry quantified bulk elemental ratios. Across both thermal regimes, uranium and cerium condensed as UO 2 and CeO 2 as dominant refractory oxide products. Uranium partially oxidized to α-UO 3 during extended ambient cooling, while furnace-assisted hold-up preserved UO 2 and produced partial reduction of cerium to Ce 2 O 3 . Cesium remained volatile upstream and condensed later in the reactor, forming Cs 2 O and Cs-uranate phases with the highest incorporation after thermal hold-up. Bulk ICP-MS measurements supported these observations. U/Ce ratios remained comparatively stable and Cs displayed delayed and apparent transient enrichment that matched the nanoscale measurements. This integrated approach provides a quantitative method for linking thermal gradients to redox evolution and volatility-driven fractionation. These results show how the plasma flow reactor can identify where equilibrium descriptions remain adequate and where kinetic effects from residence time and temperature history must be considered when interpreting condensation behavior in multicomponent systems.

and nuclear chemistry↗

Ring Electron Cooler for Electron Ion Collider

Cooling of protons at top energy (γ = 293) to counteract the IBS driven emittance growth can be beneficial to the EIC performance. The Ring Electron Cooler provides such capability.

43 PARTICLE ACCELERATORS↗

Beam optics ramping in underconstrained lattice design: Application to Electron-Ion Collider hadron storage ring cooling section

This paper presents the lattice design and optics ramping strategy for the cooling section of the hadron storage ring at the electron-ion collider. The main challenge is that available tuning knobs exceed beam-optics constraints. Independently optimized injection and top-energy optics often yield disconnected solutions, making interpolation impossible. To address this, we propose two new methods. The first is an intermediate-penalty scheme that ensures ramping path continuity by penalizing constraint violations at intermediate states. The second is a continuation-based approach that adapts high-energy optics to low energy, guided by an adaptive weighting scheme to balance injection and ramping constraints. The solutions meet all beam dynamics and hardware limits. The two methods offer a general strategy for ramping in systems where the solution space is under-constrained and the starting and target configurations are far apart.

43 PARTICLE ACCELERATORS↗

Fluid dynamic simulation and analysis of water-cooling systems for the Electron-Ion Collider

The Electron-Ion Collider is the newest large-scale project at Brookhaven National Laboratory. The collider’s purpose is to provide further advancements in the knowledge of the universe’s origin by accelerating particles near the speed of light. Our project for this 3.8 km ring was to create a thermal hydraulic steady-state simulation design of the water-cooling system to be cost-effective and energy efficient, as envisioned by Charlie Foltz, the EIC Infrastructure Division Director. The system would include a supply and return header, which cools several thousand components of the ring. The water would then be returned and cooled down using a system of cooling towers and plate and frame heat exchangers. Due to the size of the system and the complexity of the network analysis, a fluid dynamic simulation software, AFT Fathom, was used. Since previous methods of maintaining systems relied on building upon smaller real-life models and implementing empirical data, this flow model was unique and first of a kind in the domain of accelerator design, construction and operation. Therefore, our hydraulic team piloted a new method to perform network analysis on a large scale cooling system. We successfully created several test scenarios for system behavior in a shorter time compared to the method of performing hand calculations. Cooling specifications for heat rejection, pressure drop, flow rate, and pipe sizing were changed based on the individual systems of the vacuum, radio frequency (RF), magnet and power supply, and cryogenics sections. Finally, we used DOE guidelines to perform life-cycle cost analysis with net present value and carbon saving analysis on the systems where pipe size could be optimized.

43 PARTICLE ACCELERATORS↗

Cooling and Timing Tests of the ATLAS Fast TracKer VME Boards

The Fast TracKer (FTK) is an ATLAS trigger upgrade built for full-event, low-latency, high-rate tracking. The FTK core, made of 9U VME boards, performs the most demanding computational task. The associative memory board (AMB) serial link processor and the auxiliary card (AUX), plugged on the front and back sides of the same VME slot, constitute the processing unit (PU), which finds tracks using hits from eight layers of the inner detector. The PU works in pipeline with the second stage board (SSB), which finds 12-layer tracks by adding extra hits to the identified tracks. In the designed configuration, 16 PUs and four SSBs are installed in a VME crate. The high power consumption of the AMB, AUX, and SSB (respectively, of about 250, 70, and 160 W per board) required the development of a custom cooling system. Even though the expected power consumption for each VME crate of the FTK system is high compared with a common VME setup, the 8 FTK core crates will use ≈60 kW, which is just a fraction of the power and the space needed for a CPU farm performing the same task. We report on the integration of 32 PUs and eight SSBs inside the FTK system, on the infrastructures needed to run and cool them, and on the tests performed to verify the system processing rate and the temperature stability at a safe value.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗