Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electron Beam Collimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Laser-produced aluminum plasma expansion inside a plastic plasma envelope

Previous experimental results demonstrated that the plasma pressure decreases with the growing atomic number of the target material. In this context, a question arose if the Al plasma outflow could be collimated using the plastic plasma as a compressor. To solve this problem, an experiment using a plastic target with an Al cylindrical insert was performed. The focal spot diameter substantially larger than that of the insert ensured simultaneous heating both target materials. This experiment proved that a production of Al plasma jets collimated by an action of outer plastic plasma is feasible [Kasperczuk et al., Laser Part. Beams 30, 1 (2012)]. The results of investigations presented here provide additional information on distributions of electron temperature in the outflowing plasma and time and space characteristics of ion emission, both registered at bare and constrained-flow Al targets. The experiment was carried out at the Prague asterix laser system iodine laser facility. The laser provided a 250 ps (full width at half maximum) pulse with the energy of 130 J at the third harmonic frequency ({lambda}{sub 3} = 0.438 {mu}m). A plastic target with an Al cylindrical insert of 400 {mu}m in diameter as well as a bare Al target (for comparison) was used. The focal spot diameter ({Phi}{sub L}) 1200 {mu}m ensured the lateral pressure effect of the plastic plasma strong enough to guarantee the effective Al plasma compression. The electron temperature measurements have shown that such Al plasma compression is accompanied by the increase of its temperature, dominance of which starts at distance of 0.5 mm from the target surface. Measurements of ion emission characteristics confirm the earlier numerical simulation prediction that in these conditions the plasma expansion geometry is closer to planar. The constrained Al plasma jet is very narrow and its axial velocity is considerably larger than the velocity of freely expanding Al plasma stream. It means that the plastic plasma envelope, besides the Al plasma compression, also strongly accelerates the Al plasma in its axial motion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-Charge, Multi-MeV Electron Bunches Accelerated in Moderate Laser-Plasma Interaction Regime

Experiments, and simulations have shown that quasi-monoenergetic electron bunches can be accelerated from the background electron plasma population up to relativistic energies. Theoretical work indicated that with a proper choice of laser, plasma, and injection parameters the acceleration of electron bunches with small energy spread and short bunch length can occur in moderate intensity regime. Here we present the results of an experiment on electron acceleration carried out at the IPCF-CNR's Intense Laser Irradiation Laboratory in Pisa, within a wide national collaboration leaded by INFN named PLASMONX. High-charge, multi-MeV electron bunches were accelerated in moderated intensity regime by focusing the laser beam on a laminar gaseous target produced by a supersonic gas-jet. The laser-gas interaction was studied via interferometry, and Thomson scattering while the electron bunches were detected and characterised using a phosphor screen coupled with a magnetic spectrometer or a dosimetric detector. In some cases highly collimated electron bunches with moderate energy spread were observed, while the generation of high-charge, MeV energies electron bunches were obtained with high reproducibility for each gases tested.

43 PARTICLE ACCELERATORS↗

X-ray spectroscopy of warm and hot electron components in the CAPRICE source plasma at EIS testbench at GSI

An experimental campaign aiming to detect X radiation emitted by the plasma of the CAPRICE source – operating at GSI, Darmstadt – has been carried out. Two different detectors (a SDD – Silicon Drift Detector and a HpGe – hyper-pure Germanium detector) have been used to characterize the warm (2–30 keV) and hot (30–500 keV) electrons in the plasma, collecting the emission intensity and the energy spectra for different pumping wave frequencies and then correlating them with the CSD of the extracted beam measured by means of a bending magnet. A plasma emissivity model has been used to extract the plasma density along the cone of sight of the SDD and HpGe detectors, which have been placed beyond specific collimators developed on purpose. Results show that the tuning of the pumping frequency considerably modifies the plasma density especially in the warm electron population domain, which is the component responsible for ionization processes: a strong variation of the plasma density near axis region has been detected. Potential correlations with the charge state distribution in the plasma are explored.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced High Brilliance X-Ray Source

The possibility to dramatically increase the efficiency of laboratory based protein structure measurements through the use of polycapillary X-ray optics was investigated. This project initiated April 1, 1993 and concluded December 31, 1996 (including a no cost extension from June 31, 1996). This is a final report of the project. The basis for the project is the ability to collect X-rays from divergent electron bombardment laboratory X-ray sources and redirect them into quasiparallel or convergent (focused) beams. For example, a 0.1 radian (approx. 6 deg) portion of a divergent beam collected by a polycapillary collimator and transformed into a quasiparallel beam of 3 millradian (0.2 deg) could give a gain of 6(exp 2)/0.2(exp 2) x T for the intensity of a diffracted beam from a crystal with a 0.2 deg diffraction width. T is the transmission efficiency of the polycapillary diffraction optic, and for T=0.5, the gain would be 36/0.04 x O.5=45. In practice, the effective collection angle will depend on the source spot size, the input focal length of the optic (usually limited by the source spot-to-window distance on the x-ray tube) and the size of the crystal relative to the output diameter of the optic. The transmission efficiency, T, depends on the characteristics (fractional open area, surface roughness, shape and channel diameter) of the polycapillary optic and is typically in the range 0.2-0.4. These effects could substantially reduce the expected efficiency gain. During the course of this study, the possibility to use a weakly focused beam (0.5 deg convergence) was suggested which could give an additional 10-20 X efficiency gain for small samples . Weakly focused beams from double focusing mirrors are frequently used for macromolecular crystallography studies. Furthermore the crystals are typically oscillated by as much as 2 deg during each X-ray exposure in order to increase the reciprocal space (number of crystal planes) sampled and use of a slightly convergent beam could, in principle, provide a similar sampling benefit without oscillation. Although more problematic, because of complications in analyzing the diffraction patterns, it was also suggested that even more extreme beam convergence might be used to give another order of magnitude intensity gain and even smaller focused spot size which could make it possible to study smaller protein crystals than can be studied using standard laboratory based X-ray diffraction systems. This project represents the first systematic investigation of these possibilities. As initially proposed, the contract included requirements for design, purchase, evaluation and delivery of three polycapillary lenses to the Laboratory for Structural Biology at MSFC and demonstration of such optics at MSFC for selected protein crystal diffraction applications.

Gibson, Walter M.↗

Mu2e Calorimeter Clustering Studies [Slides]

aMu2e (muon-to-electron-conversion), an Intensity Frontier experiment at Fermilab set to begin data taking in 2022, will search for flavor violation in charged leptons with a muon decaying to only an electron without any neutrinos. Protons will be accelerated by the 8GeV proton beam before reaching Mu2e’s production target. From there, pions enter an S-shaped Transport Solenoid and travel through a series of absorbers and collimators to select low-energy negatively charged muons from pion decay that will hit the stopping target. Downstream from the stopping target are a curved straw tracker and two annular disk crystal calorimeters. The signal will be a mono-energetic e- with an energy close to the rest mass of a muon. The Mu2e expected single event sensitivity is 2.87e-17. The complimentary trigger strategy will take advantage of both online track searches from the tracker and calorimeter reconstruction. The trigger requires a rejection factor greater than 100 and m ust make its decision within a 3ms time budget. In order to provide high efficiency on signal events, our calorimeter clustering algorithms must be accurate and meet the timing performance. I will discuss the expected performance of two clustering algorithms: a fast algorithm to be used at the trigger level and a more accurate clustering algorithm to be used in the offline reconstruction. The fast algorithm defines clusters by only selecting crystals adjacent to a high energy crystal seed. The full-blown algorithm can find smaller clusters separated from the main cluster, within a distance and timing window, and combine them into one cluster. We have analyzed the topology of the reconstructed clusters by the two algorithms on events with only a conversion electron and combined signal and background events. The goal of these studies is to improve the performance of the fast algorithm to better reconstruct the cluster energy and work within the strict timing budget.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

FACET: SLAC___s New User Facility

FACET (Facility for Advanced Accelerator Experimental Tests) is a new User Facility at SLAC National Accelerator Laboratory. The first User Run started in spring 2012 with 20 GeV, 3 nC electron beams. The facility is designed to provide short (20 {micro}m) bunches and small (20 {micro}m wide) spot sizes, producing uniquely high power beams. FACET supports studies from many fields but in particular those of Plasma Wakefield Acceleration and Dielectric Wakefield Acceleration. The creation of drive and witness bunches and shaped bunch profiles is possible with 'Notch' Collimation. FACET is also a source of THz radiation for material studies. Positrons will be available at FACET in future user runs. We present the User Facility and the available tools and opportunities for future experiments.

43 PARTICLE ACCELERATORS↗

Transport Simulations for Fast Ignition on NIF

We are designing a full hydro-scale cone-guided, indirect-drive FI coupling experiment, for NIF, with the ARC-FIDO short-pulse laser. Current rad-hydro designs with limited fuel jetting into cone tip are not yet adequate for ignition. Designs are improving. Electron beam transport simulations (implicit-PIC LSP) show: (1) Magnetic fields and smaller angular spreads increase coupling to ignition-relevant 'hot spot' (20 um radius); (2) Plastic CD (for a warm target) produces somewhat better coupling than pure D (cryogenic target) due to enhanced resistive B fields; and (3) The optimal T{sub hot} for this target is {approx} 1 MeV; coupling falls by 3x as T{sub hot} rises to 4 MeV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Negative particle planar and axial channeling and channeling collimation

While information exists on high energy negative particle channeling there has been little study of the challenges of negative particle bending and channeling collimation. Partly this is because negative dechanneling lengths are relatively much shorter. Electrons are not particularly useful for investigating negative particle channeling effects because their material interactions are dominated by channeling radiation. Another important factor is that the current central challenge in channeling collimation is the proton-proton Large Hadron Collider (LHC) where both beams are positive. On the other hand in the future the collimation question might reemerge for electon-positron or muon colliders. Dechanneling lengths increase at higher energies so that part of the negative particle experimental challenge diminishes. In the article different approaches to determining negative dechanneling lengths are reviewed. The more complicated case for axial channeling is also discussed. Muon channeling as a tool to investigate dechanneling is also discussed. While it is now possible to study muon channeling it will probably not illuminate the study of negative dechanneling.

43 PARTICLE ACCELERATORS↗

Electron cyclotron resonance ion source plasma characterization by X-ray spectroscopy and X-ray imaging

An experimental campaign aiming to investigate electron cyclotron resonance (ECR) plasma X-ray emission has been recently carried out at the ECRISs—Electron Cyclotron Resonance Ion Sources laboratory of Atomki based on a collaboration between the Debrecen and Catania ECR teams. In a first series, the X-ray spectroscopy was performed through silicon drift detectors and high purity germanium detectors, characterizing the volumetric plasma emission. The on-purpose developed collimation system was suitable for direct plasma density evaluation, performed “on-line” during beam extraction and charge state distribution characterization. A campaign for correlating the plasma density and temperature with the output charge states and the beam intensity for different pumping wave frequencies, different magnetic field profiles, and single-gas/gas-mixing configurations was carried out. The results reveal a surprisingly very good agreement between warm-electron density fluctuations, output beam currents, and the calculated electromagnetic modal density of the plasma chamber. A charge-coupled device camera coupled to a small pin-hole allowing X-ray imaging was installed and numerous X-ray photos were taken in order to study the peculiarities of the ECRIS plasma structure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy partition, γ-ray emission, and radiation reaction in the near-quantum electrodynamical regime of laser-plasma interaction

When extremely intense lasers (I ≥ 10{sup 22} W/cm{sup 2}) interact with plasmas, a significant fraction of the pulse energy is converted into photon emission in the multi-MeV energy range. This emission results in a radiation reaction (RR) force on electrons, which becomes important at ultrahigh intensities. Using three-dimensional particle-in-cell simulations which include a quantum electrodynamics model for the γ–photons emission, the corresponding RR force and electron-positron pair creation, the energy partition in the laser-plasma system is investigated. At sufficiently high laser amplitudes, the fraction of laser energy coupled to electrons decreases, while the energy converted to γ-photons increases. The interaction becomes an efficient source of γ-rays when I > 10{sup 24} W/cm{sup 2}, with up to 40% of the laser energy converted to high-energy photons. A systematic study of energy partition and γ-photon emission angle shows the influence of laser intensity and polarization for two plasma conditions: high-density carbon targets and a low-density hydrogen targets. We find that in the opaque region, the laser-to-photon conversion efficiency scales as I{sub 0}{sup 3/2} for linearly polarized and I{sub 0}{sup 2−2.5} for circularly polarized lasers, respectively. In the relativistically transparent regime, the power-laws merge into I{sub 0}{sup 1/2} for both polarizations and photon emission peaks in the forward direction with a relatively small divergence angle (<20°), resulting in a collimated γ-ray beam.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the properties of synchrotron-like X-ray emission from laser wakefield accelerated electron beams

The electric and magnetic fields responsible for electron acceleration in a Laser Wakefield Accelerator (LWFA) also cause electrons to radiate x-ray photons. Such x-ray pulses have several desirable properties including short duration and being well collimated with tunable high energy. We measure the scaling of this x-ray source experimentally up to laser powers greater than 100 TW. An increase in laser power allows electron trapping at a lower density as well as with an increased trapped charge. These effects ended in an x-ray fluence that was measured to increase non-linearly with laser power. The fluence of x-rays was also compared with that produced from K-α emission resulting from a solid target interaction for the same energy laser pulse. The flux was demonstrated to be comparable, but the LWFA x-rays had a significantly smaller source size. This indicates that such a source may be useful as a backlighter for probing high energy density plasmas with ultrafast temporal resolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Muon spin rotation studies

The bulk of the muon spin rotation research work centered around the development of the muon spin rotation facility at the Alternating Gradient Synchrotron (AGS) of Brookhaven National Laboratory (BNL). The collimation system was both designed and fabricated at Virginia State University. This improved collimation system, plus improvements in detectors and electronics enabled the acquisition of spectra free of background out to 15 microseconds. There were two runs at Brookhaven in 1984, one run was devoted primarily to beam development and the other run allowed several successful experiments to be performed. The effect of uniaxial strain on an Fe(Si) crystal at elevated temperature (360K) was measured and the results are incorporated herein. A complete analysis of Fe pulling data taken earlier is included.

Source record↗

TU-FG-BRB-06: A Prompt Gamma-Ray Spectroscopy System for Clinical Studies of in Vivo Proton Range Verification

Purpose: We present a new system to perform prompt gamma-ray spectroscopy during proton pencil-beam scanning treatments, which enables in vivo verification of the proton range. This system will be used for the first clinical studies of this technology. Methods: After successful pre-clinical testing of prompt gamma-ray spectroscopy, a full scale system for clinical studies is now being assembled. Prompt gamma-rays will be detected during patient treatment using an array of 8 detector modules arranged behind a tungsten collimator. Each detector module consists of a lanthanum(III) bromide scintillator, a photomultiplier tube, and custom electronics for stable high voltage supply and signal amplification. A new real-time data acquisition and control system samples the signals from the detectors with analog-to-digital converters, analyses events of interest, and communicates with the beam delivery systems. The timing of the detected events was synchronized to the cyclotron radiofrequency and the pencil-beam delivery. Range verification is performed by matching measured energy- and timeresolved gamma-ray spectra to nuclear reaction models based on the clinical treatment plan. Experiments in phantoms were performed using clinical beams in order to assess the performance of the systems. Results: The experiments showed reliable real-time analysis of more than 10 million detector events per second. The individual detector modules acquired accurate energy- and time-resolved gamma-ray measurements at a rate of 1 million events per second, which is typical for beams delivered with a clinical dose rate. The data acquisition system successfully tracked the delivery of the scanned pencil-beams to determine the location of range deviations within the treatment field. Conclusion: A clinical system for proton range verification using prompt gamma-ray spectroscopy has been designed and is being prepared for use during patient treatments. We anticipate to start a first clinical study in the near future. This work was supported by the Federal Share of program income earned by Massachusetts; General Hospital on C06-CA059267, Proton Therapy Research and Treatment Center.

60 APPLIED LIFE SCIENCES↗

Coaxial charged particle energy analyzer

A non-dispersive electrostatic energy analyzer for electrons and other charged particles having a generally coaxial structure of a sequentially arranged sections of an electrostatic lens to focus the beam through an iris and preferably including an ellipsoidally shaped input grid for collimating a wide acceptance beam from a charged-particle source, an electrostatic high-pass filter including a planar exit grid, and an electrostatic low-pass filter. The low-pass filter is configured to reflect low-energy particles back towards a charged particle detector located within the low-pass filter. Each section comprises multiple tubular or conical electrodes arranged about the central axis. The voltages on the lens are scanned to place a selected energy band of the accepted beam at a selected energy at the iris. Voltages on the high-pass and low-pass filters remain substantially fixed during the scan.

Kelly, Michael A.↗

3 GeV Booster Synchrotron Conceptual Design Report

Synchrotron light cna be produced from a relativistic particle beam circulating in a storage ring at extremely high intensity and brilliance over a large spectral region reaching from the far infrared regime to hard x-rays. The particles, either electrons or positrons, radiate as they are deflected in the fields of the storage ring bending magnets or of magnets specially optimized for the production of synchrotron light. The synchrotron light being very intense and well collimated in the forward direction has become a major tool in a large variety of research fields in physics, chemistry, material science, biology, and medicine.

43 PARTICLE ACCELERATORS↗

Laser-Driven Fast Electron Collimation in Targets with Resistivity Boundary

We demonstrate experimentally that the relativistic electron flow in a dense plasma can be efficiently confined and guided in targets exhibiting a high-resistivity-core-low-resistivity-cladding structure analogous to optical waveguides. The relativistic electron beam is shown to be confined to an area of the order of the core diameter (50 {mu}m), which has the potential to substantially enhance the coupling efficiency of electrons to the compressed fusion fuel in the Fast Ignitor fusion in full-scale fusion experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Secondary electron emission from a charged dielectric in the presence of normal and oblique electric fields

The secondary electron emission coefficient was obtained for a FEP-Teflon dielectric charged with monoenergetic electrons normally incident upon the surface of the specimen. Measurements of secondary emission coefficient were done for normal and oblique incidence with different primary beam energies in the presence of normal and oblique electric fields. A collimated probing beam was directed to different points on the surface of the specimen and the released or accumulated charge was monitored using an electrometer. The measured data for different probing beam energies, different impact points and different angles of incidence were plotted vs. impact energy and impact point. Data analyzed by computer simulations to find the potential distribution on the surface of the specimen and the electric field around it, is presented and discussed.

Javidi, B.↗

Dynamic Coupling of Quasi-Electrostatic Thundercloud Fields to the Mesosphere and Lower Ionosphere: Sprites and Jets

Red Sprites and Blue Jets are two different types of recently discovered optical flashes ob- served above large thunderstorm systems. Sprites are luminous glows occurring at altitudes typically ranging from approximately 50 to 90 km. In video they exhibit a red color at their top which gradually changes to blue at lower altitudes. Sprites may occur singly or in clusters of two or more. The lateral extent of "unit" sprites is typically 5-10 km and they endure for several milliseconds. Jets are upward moving (approximately 100 km/s) highly collimated beams of luminosity, emanating from the tops of thunderclouds, extending up to approximately 50 km altitude and exhibiting a primarily blue color. We propose that sprites result from large electric field transients capable of causing electron heating, breakdown ionization and excitation of optical emissions at mesospheric altitudes following the removal of thundercloud charge by a cloud-to-ground discharge. Depending on the history of charge accumulation and removal, and the distribution of ambient atmospheric conductivity, the breakdown region may have the shape of vertically oriented ionization column(s). Results of a two-dimensional and self consistent quasi-electrostatic (QE) model indicate that most of the observed features of sprites can be explained in terms of the formation and self-driven propagation of streamer type channels of breakdown ionization. Comparison of the optical emission intensities of the 1st and 2nd positive bands of N2, Meinel and 1st negative bands of N2(+) and the 1st negative band of O2(+) demonstrates that the 1st positive band of N2 is the dominant optical emission in the altitude range approximately 50-90 km, which accounts for the observed red color of sprites. Optical emissions of the 1st and 2nd positive bands of N2 occur in carrot-like vertical structures with typical transverse dimension approximately 5-10 km which can span an altitude range from approximately 80 km to well below approximately 50 km. The appearance of optical emissions associated with sprites can be delayed in time (approximately 1-20 ms) with respect to the causative cloud to ground discharge. Theoretical model results are found to be in good agreement with recent video, photometric and spectral measurements of sprites.

Pasko, Victor Petrovich↗