Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electrical Safety”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Prognostics and Health Monitoring in Li-Ion Batteries and Capacitors Using Physics-Based Modeling Approach

In order to tackle and solve the prediction problem of the lifetime of Li-ion batteries, it is essential to have awareness of the current state and health of the battery pack. To be able to accurately predict the future state of any system, one must possess knowledge of its current and future operations. Using derived models of the current and future system behavior, a model-based prognostics approach can be implemented as a solution to the prediction problem. As more and more autonomous electric vehicles progressively emerge in our daily life, a very critical challenge lies in accurate prediction of remaining useful life of the systems/subsystems. Batteries, power electronics conditioning systems, and motors are integrated to form the powertrain in electric vehicles; one of the most critical systems. In the case of electric aircrafts, computing remaining flying time is critical for safety, since an aircraft that runs out of power (battery charge) while in the air will eventually lose control leading to catastropheThis presentation covers a physics-based modeling approach implemented for case studies in capacitor and battery prognostics which are an integral part of an electrical powertrain system. The general approach of model-based prognostics will be examined as a potential solution for safety critical problems related to battery state of charge and state of health.

Physics based modeling↗

Magnetic Shielding with Soft Magnetic Alloys

Abnormal electrical environments receive a lot of attention from nuclear safety engineers, but less attention has been paid to the magnetic effects that accompany such environments. Engineers with backgrounds outside of physics or electrical engineering may not be as familiar with this topic; this report serves as a brief summary of the phenomena and proposes experiments to support practical engineering solutions. Lightning strikes, in particular, create an environment hazardous to electronics, especially to components that rely on magnetic coupling for normal function. The most direct method of mitigating unwanted magnetic effects caused by lightning is to shield the component of interest; several materials and configuration options are explained here. An experimental approach is recommended to validate numerical modeling.

42 ENGINEERING↗

Instrumentation for Assessing DC Electrical Distribution Systems in Buildings

Direct current (DC) distribution systems is emerging as a favorable option over alternating current in buildings due to its energy and non-energy benefits (e.g., efficiency, resilience, safety). However, limited guidelines exist to evaluate the DC electrical distribution infrastructure. This paper aims to fill that gap by detailing our experience with metering a building-level electrical DC distribution system. Our case study is a DC microgrid at the Direct Energy Partners Research & Development facility located in Charlotte, North Carolina. This paper presents our approach, technical challenges, and lessons learned with DC metering and instrumentation.

buildings↗

Improving plant efficiency through the installation of TecSOLCEP online monitoring system - 362

In February 2016, Nuclear Energy Institute (NEI) launched its 'Delivering the Nuclear Promise (DNP)' strategic plan with the objective of reducing electric generating costs by 30% across the nuclear power industry by 2018. Improving efficiency has been addressed as one of the strategic focus areas in the plan. In nuclear power plants (NPPs) there is room for improvement in main components efficiency and TecSOLCEP is a software tool that has proved its value for that purpose. TecSOLCEP is a software tool for monitoring, diagnosing and quantifying performance deviations in Power Plants. It faithfully follows the methodology of ASME standards. Over 15 years of success stories in more than 50 electric power plants of different technologies worldwide, justify the benefits for the plants. The implicit concept in TecSOLCEP is 'Benefit based Maintenance' (BbM) as complementary to usual maintenance strategies like time-based, condition-based or predictive. These maintenance strategies are oriented to obtain the Safety and Reliability goals shared by all the electricity generation technologies. BbM is oriented to get the maximum economic benefit by Efficiency care, which historically has not been a priority, especially in nuclear plants. BbM applied with the help of performance monitoring tools like TecSOLCEP, is called to play an important role to improve efficiency which, in plants mainly operating at full power, is equivalent to increase the maximum power. Nuclear power plants that intend to extend their lives may also take advantage of identifying and quantifying inefficiencies in equipment to better address necessary investments. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Utilizing Code Generation from Models for Electric Aircraft Motor Controller Flight Software

The processes followed to develop and test safety-critical flight software significantly increase development effort and overhead in comparison to both non-safety-critical and non-flight software. Generating code from models can be used to reduce development effort; however, the processes for using code generation to develop flight software are relatively immature. This work presents an approach for developing safety-critical flight software utilizing code generation from models to reduce development time and effort. The presented use-case is of electric aircraft motor control software developed for NASA's X-57 Maxwell aircraft.

flight software↗

Climate Control Load Reduction Strategies for Electric Drive Vehicles in Warm Weather

Passenger compartment climate control is one of the largest auxiliary loads on a vehicle. Like conventional vehicles, electric vehicles (EVs) require climate control to maintain occupant comfort and safety, but cabin heating and air conditioning have a negative impact on driving range for all electric vehicles. Range reduction caused by climate control and other factors is a barrier to widespread adoption of EVs. Reducing the thermal loads on the climate control system will extend driving range, thereby reducing consumer range anxiety and increasing the market penetration of EVs. Researchers at the National Renewable Energy Laboratory have investigated strategies for vehicle climate control load reduction, with special attention toward EVs. Outdoor vehicle thermal testing was conducted on two 2012 Ford Focus Electric vehicles to evaluate thermal management strategies for warm weather, including solar load reduction and cabin pre-ventilation. An advanced thermal test manikin was used to assess a zonal approach to climate control. In addition, vehicle thermal analysis was used to support testing by exploring thermal load reduction strategies, evaluating occupant thermal comfort, and calculating EV range impacts. Through stationary cooling tests and vehicle simulations, a zonal cooling configuration demonstrated range improvement of 6%-15%, depending on the drive cycle. A combined cooling configuration that incorporated thermal load reduction and zonal cooling strategies showed up to 33% improvement in EV range.

33 ADVANCED PROPULSION SYSTEMS↗

Development of cathode-electrolyte-interphase for safer lithium batteries

Accompanied by the adoption of aggressive cathodes to continuously improve batteries energy density, enhancing their safety is becoming increasingly urgent for the electric vehicle development. In-situ controllable formation of robust cathode-electrolyte interphase (CEI) with high inorganic content seems to be the most promising strategy to address the thermal runaway concerns. Moreover, the in-situ formation strategy via suitable electrolyte replacement or electrolyte additives is extremely simple yet effective, especially for industrial manufacture of batteries. Here, this paper briefly reviews recent advanced CEIs formed by conventional carbonate-based electrolytes, fluorinated electrolytes, concentrated electrolytes, and solid state electrolytes. The focus on the thermal stability of the cathodes after CEI modification, and at the same time conduct safety tests at the material, cell, and module levels for comprehensive evaluation are encouraged. The review will provide inspiration for future developments in battery safety and push forward the practical applications of newly developed high-energy density batteries.

25 ENERGY STORAGE↗

Safer Batteries through Coupled Multiscale Modeling (ICCS 2015)

Batteries are highly complex electrochemical systems, with performance and safety governed by coupled nonlinear electrochemical-electrical-thermal-mechanical processes over a range of spatiotemporal scales. We describe a new, open source computational environment for battery simulation known as VIBE - the Virtual Integrated Battery Environment. VIBE includes homogenized and pseudo-2D electrochemistry models such as those by Newman-Tiedemann-Gu (NTG) and Doyle- Fuller-Newman (DFN, a.k.a. DualFoil) as well as a new advanced capability known as AMPERES (Advanced MultiPhysics for Electrochemical and Renewable Energy Storage). AMPERES provides a 3D model for electrochemistry and full coupling with 3D electrical and thermal models on the same grid. VIBE/AMPERES has been used to create three-dimensional battery cell and pack models that explicitly simulate all the battery components (current collectors, electrodes, and separator). The models are used to predict battery performance under normal operations and to study thermal and mechanical response under adverse conditions.

battery safety↗

FUELEAP Model-Based System Safety Analysis

NASA researchers, in a partnership with Boeing, are investigating a fuel-cell powered variant of the X-57 “Maxwell” Mod-II electric propulsion aircraft, which is itself derived from a stock Tecnam P2006T. The “Fostering Ultra-Efficient Low-Emitting Aviation Power” (FUELEAP) project will replace the X-57 power subsystem with a hybrid Solid-Oxide Fuel Cell (SOFC) system to increase the potential range of the electric-propulsion aircraft while dramatically improving efficiency and emissions over stock internal-combustion engines. Our FUELEAP safety analysis faces two primary challenges. First, the Part 23 certificated Tecnam P2006T is undergoing significant modifications to host the hybrid electric-propulsion system, and the challenge is to assure that the safety inherent in the stock aircraft (and subsequently in X-57 Mod-II) is not compromised by changes in avionics, aircraft structural loading, weight and balance, or other considerations. Secondly, because the SOFC power system has little (if any) relevant in-service precedent, our challenge is to assure that we identify and mitigate all reasonably plausible hazards introduced by unique FUELEAP equipage. We are investigating and utilizing Model-Based Safety Analysis (MBSA) methods to help us address these FUELEAP safety challenges. We captured aircraft-level system hazard conditions using instances of a SysML hazard block via aircraft-level Functional Hazard Analysis (FHA). Then, using SysML models of the FUELEAP architecture, we related the hazard conditions to initiating system events and possible mitigations, such as design architecture modifications or operational constraints. We are continuing to define our approach to MBSA by developing a component-by-component inventory of local failure modes and tracing their possible contribution to hazard conditions. Finally, we are applying an argument-based approach to FUELEAP assurance. Through a FUELEAP “safety case,” we are providing an explicit argument for FUELEAP safety by associating assurance evidence with overarching safety claims through a structured argument.

Woodham, Kurt P.↗

International Space Station (ISS) Plasma Contactor Unit (PCU) Utilization Plan Assessment Update

The International Space Station (ISS) vehicle undergoes spacecraft charging as it interacts with Earth's ionosphere and magnetic field. The interaction can result in a large potential difference developing between the ISS metal chassis and the local ionosphere plasma environment. If an astronaut conducting extravehicular activities (EVA) is exposed to the potential difference, then a possible electrical shock hazard arises. The control of this hazard was addressed by a number of documents within the ISS Program (ISSP) including Catastrophic Safety Hazard for Astronauts on EVA (ISS-EVA-312-4A_revE). The safety hazard identified the risk for an astronaut to experience an electrical shock in the event an arc was generated on an extravehicular mobility unit (EMU) surface. A catastrophic safety hazard, by the ISS requirements, necessitates mitigation by a two-fault tolerant system of hazard controls. Traditionally, the plasma contactor units (PCUs) on the ISS have been used to limit the charging and serve as a "ground strap" between the ISS structure and the surrounding ionospheric plasma. In 2009, a previous NASA Engineering and Safety Center (NESC) team evaluated the PCU utilization plan (NESC Request #07-054-E) with the objective to assess whether leaving PCUs off during non-EVA time periods presented risk to the ISS through assembly completion. For this study, in situ measurements of ISS charging, covering the installation of three of the four photovoltaic arrays, and laboratory testing results provided key data to underpin the assessment. The conclusion stated, "there appears to be no significant risk of damage to critical equipment nor excessive ISS thermal coating damage as a result of eliminating PCU operations during non- EVA times." In 2013, the ISSP was presented with recommendations from Boeing Space Environments for the "Conditional" Marginalization of Plasma Hazard. These recommendations include a plan that would keep the PCUs off during EVAs when the space environment forecast input to the ISS charging model indicates floating potentials (FP) within specified limits. These recommendations were based on the persistence of conditions in the space environment due to the current low solar cycle and belief in the accuracy and completeness of the ISS charging model. Subsequently, a Noncompliance Report (NCR), ISS-NCR-232G, Lack of Two-fault Tolerance to EVA Crew Shock in the Low Earth Orbit Plasma Environment, was signed in September 2013 specifying new guidelines for the use of shock hazard controls based on a forecast of the space environment from ISS plasma measurements taken prior to the EVA [ISS-EVA-312-AC, 2012]. This NESC assessment re-evaluates EVA charging hazards through a process that is based on over 14 years of ISS operations, charging measurements, laboratory tests, EMU studies and modifications, and safety reports. The assessment seeks an objective review of the plasma charging hazards associated with EVA operations to determine if any of the present hazard controls can safely change the PCU utilization plan to allow more flexibility in ISS operations during EVA preparation and execution.

Hernandez-Pellerano, Amri↗

Consequence-Driven Cybersecurity for High-Power Electric Vehicle Charging Infrastructure

Cybersecurity of high-power charging infrastructure for electric vehicles (EVs) is critical to the safety, reliability, and consumer confidence in this publicly accessible technology. Cybersecurity vulnerabilities in high-power EV charging infrastructure may also present risks to broader transportation and energy-infrastructure systems. Here, this paper details a methodology used to analyze and prioritize high-consequence events that could result from cybersecurity sabotage to high-power charging infrastructure. The highest prioritized events are evaluated under laboratory conditions for the severity of impact and the complexity of cybersecurity manipulation. Mitigation solutions and strategies are presented to secure the vulnerabilities that potentially lead to high-consequence events. These mitigations can be immediately implemented by industry or executed during the design stage.

25 ENERGY STORAGE↗

Importance of helium-3 for the future

Relevant plasma physics principles of thermonuclear research; the state of plasma physics as it pertains to the D-He(3) cycle; the technological benefits of the D-He(3) fuel cycle; the availability of He(3); and its location, methods of extraction and cost are discussed. A perspective on the rate of progress toward the goal of heating the confined plasma fuel to sufficiently high temperatures at high enough densities and for long enough times to cause substantial fusion of the atoms to take place is given in graphical form. The main technological advantages resulting from the D-He(3) fuel cycle, when compared with the DT cycle, are as follows: (1) increased electrical conversion efficiency; (2) reduced radiation damage to reactors; (3) reduced radioactive waste; (4) an increased level of safety in case of an accident; (5) the lower cost of electricity; and (6) the shorter time to commercialization. An account is given of mining He(3) on the Moon.

Kulcinski, Gerald L.↗

Design and Analysis of a Region-Wide Remotely Controllable Electrical Lock-Out System

Electric utilities have a main responsibility to protect the lives and safety of their workers when they are working on low-, medium-, and high-voltage power lines and distribution circuits. With the anticipated widespread deployment of smart grids, a secure and highly reliable means of maintaining isolation of customer-owned distributed generation (DG) from the affected distribution circuits during maintenance is necessary to provide a fully de-energized work area, ensure utility personnel safety, and prevent hazards that can lead to accidents such as accidental electrocution from unanticipated power sources. Some circuits are serviced while energized (live line work) while others are de-energized for maintenance. For servicing de-energized circuits and equipment, lock-out tag-out (LOTO) programs provide a verifiable procedure for ensuring that circuit breakers are locked in the off state and tagged to indicate that status to operational personnel so that the lines will be checked for voltage to verify they are de-energized. The de-energized area is isolated from any energized sources, which traditionally are the substations. This procedure works well when all power sources and their interconnections are known armed with this knowledge, utility personnel can determine the appropriate circuits to de-energize for isolating the target line or equipment. However, with customer-owned DG tied into the grid, the risk of inadvertently reenergizing a circuit increases because circuit connections may not be adequately documented and are not under the direct control of the local utility. Thus, the active device may not be properly de-energized or isolated from the work area. Further, a remote means of de-energizing and locking out energized devices provides an opportunity for greatly reduced safety risk to utility personnel compared to manual operations. In this paper, we present a remotely controllable LOTO system that allows individual workers to determine the configuration and status of electrical system circuits and permit them to lock out customer-owned DG devices for safety purposes using a highly secure and ultra-reliable radio signal. The system consists of: (1) individual personal lockout devices, (2) lockout communications and logic module at circuit breakers, which are located at all DG devices, and (3) a database and configuration control process located at the utility operations center. The lockout system is a close permissive, i.e., loss of control power or communications will cause the circuit breaker to open. Once the DG device is tripped open, a visual means will provide confirmation of a loss of voltage and current that verifies the disconnected status of the DG. Further the utility personnel will be able to place their own lock electronically on the system to ensure a lockout functionally. The proposed LOTO system provides enhanced worker safety and protection against unintended energized lines when DG is present. The main approaches and challenges encountered through designing the proposed region-wide LOTO system are discussed in this paper. These approaches include: (1) evaluating the reliability of the proposed approach under N-modular redundancy with voter/spares configurations and (2) conducting a system level risk assessment study using the failure modes and effects analysis (FMEA) technique to identify and rank failure modes by probability of occurrence, probability of detection, and severity of consequences. This ranking allows a cost benefits analysis to be conducted such that dollars and efforts will be applied to the failures that provide greatest incremental gains in system capability (resilience, survivability, security, reliability, availability, etc.) per dollar spent whether capital, operations, or investment. Several simulation scenarios and their results are presented to demonstrate the viability of these approaches.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Characterizing electrical panel capacity, breaker space, and loads in U.S. single-family homes

Electrical panels distribute electricity to appliances, equipment, and other building loads and maintain safety by preventing overloads of branch circuits, feeders, and utility service wires connecting homes to the grid. Load calculations in the National Electrical Code (NEC) determine the capacity of installed electrical panels in the United States, which are rated in amps (A). Circuit breakers within electrical panels affect the magnitude and number of loads that panels can serve. In home retrofits and renovations, existing electrical panels may not accommodate new electrical loads, either due to insufficient electrical capacity or a lack of available breaker spaces. Homes with these panel constraints may need to replace existing panels with new panels that have greater capacity and breaker space.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of Integrated Safety and Security Models for Comprehensive Reliability and Resiliency Evaluation

The security of the electric grid and supporting energy systems is crucial to national security. One of the complexities in analyzing the security of energy systems is the safety consequences that may result from accidents. For energy systems, the goal is to ensure that they operate as intended and that any consequences are mitigated or prevented. The integration of safety and security is paramount to protecting these systems from attacks and ensuring that large consequences are prevented. This report describes an integrated safety and security methodology to evaluate cybersecurity events that can lead to large consequences. This novel approach first describes how Systems-Theoretic Process Analysis (STPA) provides a digital causal analysis for Bayesian Networks (BNs). The use of STPA causal analysis provides a systematic approach to constructing BNs that adequately model cyber scenarios that result in consequences. When combined with the technical principles described in Risk-Informed Management of Enterprise Systems (RIMES), a comprehensive risk-informed cybersecurity analysis results that allows decision-makers to prioritize systems that most impact risk.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Challenges in the Development of High Temperature Reactors

Advanced reactor designs offer potentially significant improvements over currently operating light water reactors including improved fuel utilization, increased efficiency, higher temperature operation (enabling a new suite of non-electric industrial process heat applications), and increased safety. As with most technologies, these potential performance improvements come with a variety of challenges to bringing advanced designs to the marketplace. There are technical challenges in material selection and thermal hydraulic and power conversion design that arise particularly for higher temperature, long life operation (possibly >60 years). The process of licensing a new reactor design is also daunting, requiring significant data collection for model verification and validation to provide confidence in safety margins associated with operating a new reactor design under normal and off-normal conditions. This paper focuses on the key technical challenges associated with two proposed advanced reactor concepts: the helium gas cooled Very High Temperature Reactor (VHTR) and the molten salt cooled Advanced High Temperature Reactor (AHTR).

42 ENGINEERING↗