Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Eclipse”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

SU-E-P-16: A Feasibility Study of Using Eclipse AAA for SRS Treatement

Purpose: To commission Varian Eclipse AAA for SRS treatment and compare the accuracy with Brainlab iPlan system for clinical cases measured with radiochromic film. Methods: A 6MV AAA clinical model for a Varian TrueBeam STx is used as baseline. The focal spot and field size of the baseline model(BASE) are (1.75,0.75) and 40×40cm{sup 2} respectively. Maximum field sizes, output factors(S{sub t}), FWHM focal spot and secondary source sizes are systematically adjusted to obtain an optimized model(OPT) by comparing the calculated PDD’s, profiles, and output factors with measurements taken with a stereotactic diode(SD) and, cc01 and cc04 ion chambers in Blue Phantom. In-phantom dose distributions of clinical SRS fields are calculated using the OPT and the clinical Brainlab iPlan pencil-beam. Within the 90% isodose-line(ROI), the average dose difference between the calculations and radiochromic film measurements are assessed. Results: The maximum field, focal spot and secondary source sizes for the OPT are 15×15cm{sup 2}, (0,0), and 32.3mm respectively. The OPT St input at 1.0 and 2.0cm fields are increased by 4.5% and 1.5% from BASE. The calculated output of the BASE and OPT underestimate by 16.1%–3.2% respectively at 0.5×0.5cm{sup 2} field and 3.1%−0.02% respectively at 1.0×1.0cm{sup 2} field. The depth doses at 10cm are within 3.5% and 0.4% of measurements for 0.5×0.5 and 1.0×1.0cm{sup 2}. The ROI dose of OPT and iPlan are within 1.6% and 0.6% of film measurements for 3.0cm clinical fields. For 1.0cm fields, the ROI dose of OPT underestimate 0.0–2.0% and iPlan overestimates 1.7–2.9% relative to measurements. Conclusion: The small field dose calculation of Eclipse AAA algorithm can be significantly improved by carefully adjusting the input parameters. The larger deviation of the OPT for 0.5×0.5cm{sup 2} field from measurements can be attributed to the lowest 1.0cm field size input limit of AAA. The OPT compares reasonably well with the iPlan pencil-beam and measurements.

60 APPLIED LIFE SCIENCES↗

SU-E-T-196: Comparative Analysis of Surface Dose Measurements Using MOSFET Detector and Dose Predicted by Eclipse - AAA with Varying Dose Calculation Grid Size

Purpose: Skin dose can be the limiting factor and fairly common reason to interrupt the treatment, especially for treating head-and-neck with Intensity-modulated-radiation-therapy(IMRT) or Volumetrically-modulated - arc-therapy (VMAT) and breast with tangentially-directed-beams. Aim of this study was to investigate accuracy of near-surface dose predicted by Eclipse treatment-planning-system (TPS) using Anisotropic-Analytic Algorithm (AAA)with varying calculation grid-size and comparing with metal-oxide-semiconductor-field-effect-transistors(MOSFETs)measurements for a range of clinical-conditions (open-field,dynamic-wedge, physical-wedge, IMRT,VMAT). Methods: QUASAR™-Body-Phantom was used in this study with oval curved-surfaces to mimic breast, chest wall and head-and-neck sites.A CT-scan was obtained with five radio-opaque markers(ROM) placed on the surface of phantom to mimic the range of incident angles for measurements and dose prediction using 2mm slice thickness.At each ROM, small structure(1mmx2mm) were contoured to obtain mean-doses from TPS.Calculations were performed for open-field,dynamic-wedge,physical-wedge,IMRT and VMAT using Varian-21EX,6&15MV photons using twogrid-sizes:2.5mm and 1mm.Calibration checks were performed to ensure that MOSFETs response were within ±5%.Surface-doses were measured at five locations and compared with TPS calculations. Results: For 6MV: 2.5mm grid-size,mean calculated doses(MCD)were higher by 10%(±7.6),10%(±7.6),20%(±8.5),40%(±7.5),30%(±6.9) and for 1mm grid-size MCD were higher by 0%(±5.7),0%(±4.2),0%(±5.5),1.2%(±5.0),1.1% (±7.8) for open-field,dynamic-wedge,physical-wedge,IMRT,VMAT respectively.For 15MV: 2.5mm grid-size,MCD were higher by 30%(±14.6),30%(±14.6),30%(±14.0),40%(±11.0),30%(±3.5)and for 1mm grid-size MCD were higher by 10% (±10.6), 10%(±9.8),10%(±8.0),30%(±7.8),10%(±3.8) for open-field, dynamic-wedge, physical-wedge, IMRT, VMAT respectively.For 6MV, 86% and 56% of all measured values agreed better than ±20% for 1mm and 2.5mm grid-sizes respectively. For 18MV, 56% and 18% of all measured-values agreed better than ±20% for 1mm and 2.5mm grid-sizes respectively. Conclusion: Reliable Skin-dose calculations by TPS can be very difficult due to steep dose-gradient and inaccurate beam-modelling in buildup region.Our results showed that Eclipse over-estimates surface-dose.Impact of grid-size is also significant,surface-dose increased up to 40% from 1mm to 2.5mm,however, 1mm calculated-values closely agrees with measurements. Due to large uncertnities in skin-dose predictions from TPS, outmost caution must be exercised when skin dose is evaluated,a sufficiently smaller grid-size(1mm)can improve the accuracy and MOSFETs can be used for verification.

60 APPLIED LIFE SCIENCES↗

SU-E-T-277: Dose Calculation Comparisons Between Monaco, Pinnacle and Eclipse Treatment Planning Systems

Purpose: Monaco treatment planning system (TPS) version 5.0 uses a Monte-Carlo based dose calculation engine. The aim of this study is to verify and compare the Monaco based dose calculations with both Pinnacle{sup 3} collapsed cone convolution superposition (CCC) and Eclipse analytical anisotropic algorithm (AAA) calculations. Methods: For this study, previously treated SBRT lung, head and neck and abdomen patients were chosen to compare dose calculations between Pinnacle, Monaco and Eclipse. Plans were chosen from those that had been treated using the Elekta VersaHD or a NovalisTX linac. The plans included 3D conventional and IMRT beams using 6MV and 6MV Flattening filter free (FFF) photon beams. The original plans calculated with CCCS or AAA along with the recalculated ones using MC from the three TPS were exported into Velocity software for inter-comparison. Results: To compare the dose calculations, Mean Lung Dose (MLD), lung V5 and V20 values, and PTV Heterogeneity indexes (HI) and Conformity indexes (CI) were all calculated and recorded from the dose volume histograms (DVH). For each patient, the CI values were identical but there were differences in all other parameters. The HI was computed higher by 5 and 4% for calculated plans AAA and CCCS respectively, compared to the MC ones. The DVH graphs showed large differences between the CCCS and AAA and Monaco for 3D FFF, VMAT and IMRT plans. Better DVH agreement between was observed for 3D conventional plans. Conclusion: Better agreement was observed between CCCS and MC calculations than AAA and MC calculations. Those differences were more profound as the field size was decreasing and in the presence of inhomogeneities.

60 APPLIED LIFE SCIENCES↗

SU-F-SPS-05: Experimental Validation of Peripheral Dose Distribution of Electron Beams for Eclipse Electron Monte Carlo Algorithm

Purpose: In this study, the two available calculation algorithms of the Varian Eclipse treatment planning system(TPS), the electron Monte Carlo(eMC) and General Gaussian Pencil Beam(GGPB) algorithms were used to compare measured and calculated peripheral dose distribution of electron beams. Methods: Peripheral dose measurements were carried out for 6, 9, 12, 15, 18 and 22 MeV electron beams of Varian Triology machine using parallel plate ionization chamber and EBT3 films in the slab phantom. Measurements were performed for 6×6, 10×10 and 25×25cm{sup 2} cone sizes at dmax of each energy up to 20cm beyond the field edges. Using the same film batch, the net OD to dose calibration curve was obtained for each energy. Films were scanned 48 hours after irradiation using an Epson 1000XL flatbed scanner. Dose distribution measured using parallel plate ionization chamber and EBT3 film and calculated by eMC and GGPB algorithms were compared. The measured and calculated data were then compared to find which algorithm calculates peripheral dose distribution more accurately. Results: The agreement between measurement and eMC was better than GGPB. The TPS underestimated the out of field doses. The difference between measured and calculated doses increase with the cone size. The largest deviation between calculated and parallel plate ionization chamber measured dose is less than 4.93% for eMC, but it can increase up to 7.51% for GGPB. For film measurement, the minimum gamma analysis passing rates between measured and calculated dose distributions were 98.2% and 92.7% for eMC and GGPB respectively for all field sizes and energies. Conclusion: Our results show that the Monte Carlo algorithm for electron planning in Eclipse is more accurate than previous algorithms for peripheral dose distributions. It must be emphasized that the use of GGPB for planning large field treatments with 6 MeV could lead to inaccuracies of clinical significance.

60 APPLIED LIFE SCIENCES↗

SU-F-T-256: 4D IMRT Planning Using An Early Prototype GPU-Enabled Eclipse Workstation

Purpose: True 4D IMRT planning, based on simultaneous spatiotemporal optimization has been shown to significantly improve plan quality in lung radiotherapy. However, the high computational complexity associated with such planning represents a significant barrier to widespread clinical deployment. We introduce an early prototype GPU-enabled Eclipse workstation for inverse planning. To our knowledge, this is the first GPUintegrated Eclipse system demonstrating the potential for clinical translation of GPU computing on a major commercially-available TPS. Methods: The prototype system comprised of four NVIDIA Tesla K80 GPUs, with a maximum processing capability of 8.5 Tflops per K80 card. The system architecture consisted of three key modules: (i) a GPU-based inverse planning module using a highly-parallelizable, swarm intelligence-based global optimization algorithm, (ii) a GPU-based open-source b-spline deformable image registration module, Elastix, and (iii) a CUDA-based data management module. For evaluation, aperture fluence weights in an IMRT plan were optimized over 9 beams,166 apertures and 10 respiratory phases (14940 variables) for a lung cancer case (GTV = 95 cc, right lower lobe, 15 mm cranio-caudal motion). Sensitivity of the planning time and memory expense to parameter variations was quantified. Results: GPU-based inverse planning was significantly accelerated compared to its CPU counterpart (36 vs 488 min, for 10 phases, 10 search agents and 10 iterations). The optimized IMRT plan significantly improved OAR sparing compared to the original internal target volume (ITV)-based clinical plan, while maintaining prescribed tumor coverage. The dose-sparing improvements were: Esophagus Dmax 50%, Heart Dmax 42% and Spinal cord Dmax 25%. Conclusion: Our early prototype system demonstrates that through massive parallelization, computationally intense tasks such as 4D treatment planning can be accomplished in clinically feasible timeframes. With further optimization, such systems are expected to enable the eventual clinical translation of higher-dimensional and complex treatment planning strategies to significantly improve plan quality. This work was partially supported through research funding from National Institutes of Health (R01CA169102) and Varian Medical Systems, Palo Alto, CA, USA.

60 APPLIED LIFE SCIENCES↗

The Factory and the Beehive. III. PTFEB132.707+19.810, A Low-mass Eclipsing Binary in Praesepe Observed by PTF and K2

Theoretical models of stars constitute the fundamental bedrock upon which much of astrophysics is built, but large swaths of model parameter space remain uncalibrated by observations. The best calibrators are eclipsing binaries in clusters, allowing measurement of masses, radii, luminosities, and temperatures for stars of known metallicity and age. We present the discovery and detailed characterization of PTFEB132.707+19.810, a P = 6.0 day eclipsing binary in the Praesepe cluster (τ ∼ 600–800 Myr; [Fe/H] = 0.14 ± 0.04). The system contains two late-type stars (SpT{sub P} = M3.5 ± 0.2; SpT{sub S} = M4.3 ± 0.7) with precise masses (M{sub p}=0.3953±0.0020 M {sub ⊙}; M{sub s}=0.2098 ±0.0014 M {sub ⊙}) and radii (R{sub p}=0.363±0.008 R {sub ⊙}; R{sub s}=0.272±0.012 R {sub ⊙}). Neither star meets the predictions of stellar evolutionary models. The primary has the expected radius but is cooler and less luminous, while the secondary has the expected luminosity but is cooler and substantially larger (by 20%). The system is not tidally locked or circularized. Exploiting a fortuitous 4:5 commensurability between P {sub orb} and P{sub rot,prim}, we demonstrate that fitting errors from the unknown spot configuration only change the inferred radii by ≲1%–2%. We also analyze subsets of data to test the robustness of radius measurements; the radius sum is more robust to systematic errors and preferable for model comparisons. We also test plausible changes in limb darkening and find corresponding uncertainties of ∼1%. Finally, we validate our pipeline using extant data for GU Boo, finding that our independent results match previous radii to within the mutual uncertainties (2%–3%). We therefore suggest that the substantial discrepancies are astrophysical; since they are larger than those for old field stars, they may be tied to the intermediate age of PTFEB132.707+19.810.

79 ASTRONOMY AND ASTROPHYSICS↗

Envelopes in eclipsing binary stars

Theoretical research on eclipsing binaries is presented. The specific areas of investigation are the following: (1) the relevance of envelopes to the study of the light curves of eclipsing binaries, (2) the disk envelope, and (3) the spherical envelope.

Huang, S.↗

Ultraviolet photometry of the eclipsing variable CW Cephei

A series of photometric observations was made of the eclipsing variable CW Cephei on the OAO 2. Approximate elements were derived from the eclipse depths and shape of the secondary. Persistent asymmetries and anomalous light variations, larger than the expected experimental error, were also found, subsequent ground-based observations show H alpha entirely in emission, indicating the presence of an extended gaseous system surrounding one or both components. A detailed comparison was made of the flux distribution of the binary relative to that for the nominally unreddened stars delta Pic, BlIII, and eta Aur, B3V, to investigate the effects of interstellar extinction. The resultant extinction curves, normalized at a wavelength of 3330 A, show a relatively smooth increase with decreasing wavelength.

Sobieski, S.↗

Ultraviolet photometry of the eclipsing variable CW Cephei

An extended series of photometric observations were made of the eclipsing variable CW Cephei using the Wisconsin instrument on OAO-2. Approximate elements which were derived based solely on the eclipse depths and shape of the secondary are in satisfactory agreement with those found using ground based observations. However, persistent asymmetries and anomalous light variations, all larger than the expected experimental error, were also found; subsequent ground-based observations show H sub alpha entirely in emission indicating the presence of an extended gaseous system surrounding one or both of the components. Consistent solutions utilizing all data at all wavelengths were not found.

Sobieski, S.↗

Measurement of total electron content with a geostationary satellite during the solar eclipse of March 7, 1970.

This note deals with the measurement of the total electron content of the ionosphere at the Goddard Space Flight Center, looking towards the geostationary satellite ATS 3 during the solar eclipse of Mar. 7, 1970. Obscuration at this site was nearly total. Faraday rotation was measured with a stationary circularly polarized antenna and a dual-channel phase-lock receiver tuned to 137.350 MHz. By comparing the electrical phase of the two opposite circularly polarized components, a continuous chart recording was made of Faraday rotation vs local time. A depletion of about 25% in electron content was observed from first contact to the time of minimum electron content. The time variations of the electron content during the eclipse are briefly examined in the light of current theories of ionospheric processes.

Rangaswamy, S.↗

Polarimetry of the daytime sky during solar eclipses.

Measurement of the degree of linear polarization of the residual illumination in the umbral region in different colors at intermediate levels in the atmosphere (10 to 12 km) during the total solar eclipses of May 30, 1965, and Nov. 12, 1966. The objective was to examine the polarization characteristics of light that had been scattered more than once. It is found that, in the middle of the visible region of the electromagnetic spectrum (0.4 to 0.6 micron), multiply scattered light is partially linearly polarized (about 20%) at the altitudes where the measurements have been made. Results of similar ground-based measurements performed during the annular eclipse of Sept. 11, 1969, are also briefly discussed.

Nagaraja Rao, C. R.↗

The electron heating rate and ion chemistry in the thermosphere above Wallops Island during the solar eclipse of 7 March 1970.

Measurement of the N2 concentration and temperature, the ion composition and concentrations, and the electron temperature up to 290 km about 30 and 5 min before totality during the Mar. 7, 1970, eclipse. The rockets traveled similar trajectories, thus permitting the purely temporal changes between flights to be resolved. The neutral temperature and N2 concentration changed little, but the electron temperature decreased by as much as 20% in the lower F region. The ion concentration decreased by about 30% in the F region and about 50% in the E region, with little change in relative ion composition. The electron cooling rates decreased by a factor of 6 in the lower F region, approximately in proportion to the change in the visible solar disk. A smaller than expected decrease in the cooling rate below 150 km between the two flights indicates a hardening of the solar spectrum and suggests a significant heat contribution from the solar corona near totality. The ion composition measurements were consistent with solutions of the ion continuity equations. A proper fit required a factor-of-three enhancement of the flux below 200 A, an amount also consistent with the electron heat balance analysis. Reactions involving the minor ions N(+) and N2(+) were found to be important for the ion chemistry of the major ions O2(+) and NO(+), especially at the time of eclipse.-

Brace, L. H.↗

Rocket measurements of conjugate photoelectrons during the total solar eclipse of 7 March 1970 over Wallops Island.

Results of measurements made with a retarding potential analyzer on a Nike-Tomahawk rocket during the totality of the solar eclipse, showing definite evidence for the existence of photoelectrons from the conjugate hemisphere. Photoelectrons are observed in the altitude range from 120 to 260 km. The observed flux in the energy range from 2 to 30 eV is relatively constant above about 200 km, but decreased below that altitude. The flux of 5-eV energy electrons above 200 km altitude is about 10 to the 7th power electrons/cm/sec/eV. Higher-energy electrons were also observed, and it is possible that the energy content of these observed fluxes of conjugate-point photoelectrons is sufficient to maintain the observed electron densities and temperatures during the total eclipse.

Maier, E. J.↗

Observations of the total lunar eclipse on February 10, 1971 at 3.1 mm wavelength.

Observations were made of the total lunar eclipse on February 10, 1971 at a wavelength of 3.1 mm at the Millimeter Wave Observatory of the University of Texas at Austin. Eclipse cooling curves obtained for Copernicus, Mare Serenitatis, and a mountainous region indicate maximum temperature decreases of 6.77%, 6.37%, and 7.51%, respectively. Cooling rates of about 6 K/hour were measured. The normalized solar insolation has also been calculated for each region.

Ulich, B. L.↗

Eclipse design limits for circular orbits.

By means of simple geometric construction compact expressions for the maximum and minimum eclipse durations of a circular orbit, whose semimajor axis and inclination are specified, can be obtained. The method outlined in this note provides the designer with the necessary envelope of eclipse durations that a spacecraft will experience throughout its lifetime, and, therefore, provides a quick method of estimating necessary thermal constraints. Moreover, the closed form method presented eliminates the need for extensive machine time expenditure previously required for this type of analysis. Some numerical data to aid in the design of the spacecraft is provided.

Escobal, P. R.↗

A computer program for modeling non-spherical eclipsing binary star systems

The accurate analysis of eclipsing binary light curves is fundamental to obtaining information on the physical properties of stars. The model described accounts for the important geometric and photometric distortions such as rotational and tidal distortion, gravity brightening, and reflection effect. This permits a more accurate analysis of interacting eclipsing star systems. The model is designed to be useful to anyone with moderate computing resources. The programs, written in FORTRAN 4 for the IBM 360, consume about 80k bytes of core. The FORTRAN program listings are provided, and the computational aspects are described in some detail.

Wood, D. B.↗

Infrared atlas charts of the eclipsed moon.

The objective of this atlas is to present the thermal response of the lunar surface observed during an eclipse of the moon with accurate position data. The observations were made at a wavelength of 11 microns with an angular resolution of 10 sec, equivalent to 17 km at the disk center. Over a thousand thermally anomalous regions (hot spots) were detected. They cool more slowly than their environs and remain warmer than their environs during the umbral phase. In addition to these very localized hot spots, some of the maria show thermal enhancements during the eclipse. Fourty four charts make up this atlas which are identical in coverage and projection to the Lunar Atlas Charts (LAC) series. The charts are in the form of digital images of a normalized temperature difference which is particularly useful for studying regions of small thermal enhancements. Each increase of intensity corresponds to a 4 K temperature increase.

Shorthill, R. W.↗