Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ENERGY RANGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Reviewing E(sub peak) Relations with Swift and Suzaku Data

In recent years several authors have derived correlations between gamma-ray burst (GRB) spectral peak energy (E(sub peak)) and either isotropic-equivalent radiated energy (E(sub iso)) or peak luminosity (L(sub iso)). Since these relationships are controversial, but could provide redshift estimators, it is important to determine whether bursts detected by Swift exhibit the same correlations. Swift has greatly added to the number of GRBs for which redshifts are known and hence E(sub iso) and L(sub iso) could be calculated. However, for most bursts it is not possible to adequately constrain E(sub peak) with Swift data alone since most GRBs have E(sub peak) above the energy range (15-50 keV) of the Swift Burst Alert Telescope (BAT). Therefore we have analyzed the spectra of 78 bursts (31 with redshift) which were detected by both Swift/BAT and the Suzaku Wide-band All-sky Monitor (WAM), which covers the energy range 50-5000 keV. For most bursts in this sample we can precisely determine E(sub peak) and for bursts with known redshift we can compare how the E(sub peak) relations for the Swift/Suzaku sample compare to earlier published results. Keywords: gamma rays: bursts

Krimm, Hans A.↗

A high transmission tender X-ray monochromator employing a matched pair of multilayer grating and mirror

It is now well established that multilayer coated gratings may offer high diffraction efficiencies over the tender X-ray range, from about 1 keV to 5 keV, covering the gap between single layer coated grating monochromators and crystal monochromators. Nevertheless, few beamlines in the world are using such gratings in their monochromator. The successful implementation of a multilayer grating monochromator requires producing a matched pair of a multilayer grating and a multilayer mirror, and this matching is not straightforward as it must account for different incidence angles and refraction effects on each element. Here we review the realization of the multilayer grating monochromator of the SIRIUS beamline which has been successfully in service for several years. We show how, by alternating computer simulation with our diffraction code and measurements, we could optimize the monochromator transmission on a very wide energy range. After the grating was coated, it was found that the angle of optimal efficiency versus photon energy was significantly different from what was predicted by a simple conformal model of binary layers. Layer interdiffusion and profile smoothing during the deposition process must be added to the multilayer model to reproduce the measured data. The critical adjustment of the mirror multilayer period is achieved by the lateral translation of the mirror, which was given a small transverse period gradient. The monochromator is thus providing high transmission efficiency in the 1 to 5 keV energy range, more than 30% over 2.5 keV and up to 46% at 4.6 keV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Coupled-channels analysis of pion and η electroproduction within the Jülich-Bonn-Washington model

Pion and η electroproduction data are jointly analyzed for the first time, up to a center-of-mass energy of 1.6 GeV. The framework is a dynamical coupled-channels model, based on the recent Jülich-Bonn-Washington analysis of pion electroproduction data for the same energy range. Comparisons are made to a number of single-channel η electroproduction fits. By comparing multipoles of comparable fit quality, we find some of these amplitudes are well determined over the near-threshold region, while others will require fits over an extended energy range.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Energetic Neutral Atom Imaging at Low Altitudes from the Swedish Microsatellite Astrid: Images and Spectral Analysis

Observations of energetic neutral atoms (ENA) in the energy range 26- 52 keV are reported from four occasions during geomagnetically disturbed periods. The data were acquired by the ENA imager flown on the Swedish microsatellite Astrid in a 1000 km circular orbit with 83 deg inclination. The ENA imager separates charged particles from neutrals through an electrostatic deflection system in the energy range between 0.1 and 114 keV. ENA images obtained from vantage points in the polar cap and in the afternoon magnetic local time (MLT) hours looking into the antisunward hemisphere show intense ENA fluxes (approx. 10(exp 4)/sq cm sr s over 26-37 keV) coming from the dusk region and low altitudes (approx. 300 km). The morphology shows no relation to local magnetic field excluding the possibility of charged particle detection. It is concluded that the source of these ENAs are precipitating/mirroring ions from the ring current/trapped radiation interacting with the exobase on auroral L-shells and in the dusk region. The observed ENA fluxes show a relation with Kp and Dst geomagnetic indices. The observed ENA spectrum from a geomagnetic storm on February 8, 1995, is investigated in more detail and compared to the parent ion spectrum obtained by the Defense Meteorological Satellite Project (DMSP) satellite, Fl2, during the same period on L = 6 +/- 2 around dusk. The observed ENA spectral slope is used to derive the parent ion spectral temperature. The derived ion temperatures range is 3.0 - 6.0 keV for H and 4.5 - 8.5 keV for O. The higher of these ion temperatures comes closest in agreement to the extrapolated DMSP spectrum leading us to favor O over H as the species of the detected ENAS. It is shown that the detected ENAs must have been produced at L greater than or equal to 6 to reach the detector without atmospheric attenuation and that the main energy dependence of the ENA spectrum, apart from the parent ion spectrum, is governed by the energy dependence of the charge exchange cross section between ions and exospheric oxygen.

Brandt, Pontus C:son↗

Nucleon-Nucleon Total Cross Section

The total proton-proton and neutron-proton cross sections currently used in the transport code HZETRN show significant disagreement with experiment in the GeV and EeV energy ranges. The GeV range is near the region of maximum cosmic ray intensity. It is therefore important to correct these cross sections, so that predictions of space radiation environments will be accurate. Parameterizations of nucleon-nucleon total cross sections are developed which are accurate over the entire energy range of the cosmic ray spectrum.

Norbury, John W.↗

Observations of Taurus X-1 by the 1-60 keV X-ray detector on the OSO-7.

The seventh Orbiting Solar Observatory, OSO-7, carries an X-ray detector for measuring the positions, spectra, and time variations of X-ray sources in the energy range from 1 to 60 keV. The instrument has operated successfully since the launch on 1971 September 29. The purpose of this paper is to describe the instrument and to report a measurement of the spectrum of Tau X-1 based on data covering the widest energy range that has so far been observed in a single experiment.

Clark, G. W.↗

Which nuclear data can be validated with LLNL pulsed-sphere experiments?

It is shown here that 14-MeV D+T LLNL pulsed-sphere experiments bring complementary information into the process of validating nuclear data compared to experiments that are traditionally used for this purpose—such as critical assemblies. To be more specific, the 14-MeV D+T LLNL pulsed-sphere neutron-leakage spectra enable to validate scattering and fission nuclear data up to 15 MeV (compared to approximately up to 5 MeV when using criticality experiments) and employ to this end simple compound targets containing only few isotopes. In this work, sensitivity profiles of the spectra to nuclear data are calculated in order to understand in detail which isotopes, observables, and energy ranges of nuclear data contribute significantly to their simulation. These profiles are presented for a few selected spheres containing 16 O, 12 C, 56 Fe, and 239 Pu. It is shown that the neutron-leakage spectra of spheres containing light elements are mostly sensitive to elastic- and inelastic-scattering cross sections on discrete levels and corresponding angular distributions. Spheres of structural materials are sensitive to elastic- and inelastic-scattering cross sections, including scattering on discrete levels and the continuum, and double-differential cross sections. Actinide spheres are also strongly sensitive to the fission observables, in particular to the total-fission neutron spectrum. Thin spheres (in which neutrons experience on average less than one scatter) are mostly sensitive to data near the elastic peak, in the energy range from 12–15 MeV, while thicker ones can be sensitive to data at lower incident-neutron energies due to multiple-scattering effects. This information is brought together with simulations of 71 pulsed-sphere neutron-leakage spectra using the ENDF/B-VII.1 and ENDF/B-VIII.0 nuclear-data libraries. This analysis highlights ENDF/B-VIII.0 data that could be further investigated for potential shortcomings ( 6 Li, 12 C, 16 O, 24-26 Mg, 27 Al, 48 Ti, 56 Fe, and 208 Pb) or are likely reliable ( 1,2 H, 7 Li, 9 Be, 14 N, 235,238 U, and 239 Pu) as indicated by validating with LLNL pulsed-sphere experiments.

14-MeV D+T LLNL pulsed-sphere neutron-leakage spec↗

Cosmic antihelium-3 nuclei sensitivity of the GAPS experiment

The General Antiparticle Spectrometer (GAPS) is an Antarctic balloon experiment designed for low-energy (0.1-0.3 GeV/n) cosmic antinuclei as signatures of dark matter annihilation or decay. GAPS is optimized to detect low-energy antideuterons, as well as to provide unprecedented sensitivity to low-energy antiprotons and antihelium nuclei. The novel GAPS antiparticle detection technique, based on the formation, decay, and annihilation of exotic atoms, provides greater identification power for these low-energy antinuclei than previous magnetic spectrometer experiments. This work reports the sensitivity of GAPS to detect antihelium-3 nuclei, based on full instrument simulation, event reconstruction, and realistic atmospheric influence simulations. The report of antihelium nuclei candidate events by AMS-02 has generated considerable interest in antihelium nuclei as probes of dark matter and other beyond the Standard Model theories. GAPS is in a unique position to detect or set upper limits on the cosmic antihelium nuclei flux in an energy range that is essentially free of astrophysical background. In three 35-day long-duration balloon flights, GAPS will be sensitive to an antihelium flux on the level of $1.3^{+4.5}_{-1.2} $ ∙ 10 -6 m -2 sr -1 s -1 (GeV/n) -1 (95% confidence level) in the energy range of 0.11-0.3 GeV/n, opening a new window on rare cosmic physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Long-range energy-state maneuvers for minimum time to specified terminal conditions

The calculus of variations and energy-state approximation are used to determine the optimum maneuvers in three-dimensional minimum-time aircraft flight paths to a specified final point or line. Constraints on thrust, Mach number, angle of attack, dynamic pressure, and load factor are included. It is shown that when the initial range is sufficiently large that the maximum velocity constraint is encountered en route, the calculation of minimum-time maneuvers can be greatly simplified by a separation of arcs into two two-parameter problems. Suboptimal paths along which the bank angle is restricted to three discrete values (negative maximum angle, 0, positive maximum angle) compare favorably with the optimum, continuous bank angle solutions for transonic speeds and below.

Parsons, M. G.↗

Verifying MCNP Models of the TEX High 240 Plutonium Benchmark

Computational modeling programs are invaluable tools that allow us to understand systems, safely develop new processes, and make reliable predictions about future designs. However, the effectiveness of these codes is limited by the degree to which their parameters match the real world. In the field of nuclear engineering, cross section data is one of these vital parameters. Accurate cross section data on important fissile and fissionable isotopes promotes the design of safer and more efficient fabrication, transportation, storage, and stockpiling of nuclear fuel. Unfortunately, there are knowledge gaps in data on key isotopes. In 2011, a multinational meeting hosted by the US Department of Energy Nuclear Criticality Safety Program ranked the priority of certain cross section data needs. In response, Lawrence Livermore National Lab (LLNL) designed the Thermal and Epithermal eXperiment (TEX) series of benchmark experiments. Benchmark experiments are used to validate current cross section data. They validate data by comparing the results of an actual experiment to the predicted results from a computational model. The data a benchmark applies to depends on the isotope and energy range the experiment’s neutron multiplication factor ( k eff ) is most sensitive to. The development and testing of the TEX High 240 Plutonium Benchmark will help validate 240 Pu cross section data. The configuration and materials of this benchmark are designed to be most sensitive to 240 Pu's intermediate energy range (from 0.625 ev to 100 keV ). MCNP® models of the assembly have been developed by LLNL and the results have been written in the final design report. In order for the discrepancies between benchmark models and experiments to be attributed to cross section inaccuracies, the accuracy of the models needs to be verified. The goal of this project is to verify of the results of LLNL's modeling by creating a new set of MCNP models and comparing the results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

EGRET Diffuse Gamma Ray Maps Between 30 MeV and 10 GeV

This paper presents all-sky maps of diffuse gamma radiation in various energy ranges between 30 MeV and 10 GeV, based on data collected by the EGRET instrument on the Compton Gamma Ray Observatory. Although the maps can be used for a variety of applications, the immediate goal is the generation of diffuse gamma-ray maps which can be used as a diffuse background/foreground for point source analysis of the data to be obtained from new high-energy gamma-ray missions like GLAST and AGILE. To generate the diffuse gamma maps from the raw EGRET maps, the point sources in the Third EGRET Catalog were subtracted out using the appropriate point spread function for each energy range. After that, smoothing was performed to minimize the effects of photon statistical noise. A smoothing length of 1deg was used for the Galactic plane maps. For the all-sky maps, a procedure was used which resulted in a smoothing length roughly equivalent to 4deg. The result of this work is 16 maps of different energy intervals for [b]less than or equal to 20deg, and 32 all-sky maps, 16 in equatorial coordinates (J2000) and 16 in Galactic coordinates.

Cillis, A. N.↗

Measurement of Insulation Compaction in the Cryogenic Fuel Tanks at Kennedy Space Center by Fast/Thermal Neutron Techniques

The liquid hydrogen and oxygen cryogenic storage tanks at John F. Kennedy Space Center (KSC) use expanded perlite as thermal insulation. Th ere is evidence that some of the perlite has compacted over time, com promising the thermal performance and possibly also structural integr ity of the tanks. Therefore an Non-destructive Testing (NDT) method for measuring the perlite density or void fraction is urgently needed. Methods based on neutrons are good candidates because they can readil y penetrate through the 1.75 cm outer steel shell and through the ent ire 120 cm thickness of the perlite zone. Neutrons interact with the nuclei of materials to produce characteristic gamma rays which are the n detected. The gamma ray signal strength is proportional to the atom ic number density. Consequently, if the perlite is compacted then the count rates in the individual peaks in the gamma ray spectrum will i ncrease. Perlite is a feldspathic volcanic rock made up of the major elements Si, AI, Na, K and 0 along with some water. With commercially available portable neutron generators it is possible to produce simul taneously fluxes of neutrons in two energy ranges: fast (14 MeV) and thermal (25 meV). Fast neutrons produce gamma rays by inelastic scatt ering which is sensitive to Fe and O. Thermal neutrons produce gamma rays by radiative capture in prompt gamma neutron activation (PGNA) and this is sensitive to Si, AI, Na, Kand H. Thus the two energy ranges produce complementary information. The R&D program has three phases: numerical simulations of neutron and gamma ray transport with MCNP s oftware, evaluation of the system in the laboratory on test articles and finally mapping of the perlite density in the cryogenic tanks at KSC. The preliminary MCNP calculations have shown that the fast/therma l neutron NDT method is capable of distinguishing between expanded an d compacted perlite with excellent statistics.

Livingston, R. A.↗

EGRET Diffuse Gamma Ray Maps Between 30 MeV and 10 GeV

This paper presents all-sky maps of diffuse gamma radiation in various energy ranges between 30 MeV and 10 GeV, based on data collected by the EGRET instrument on the Compton Gamma Ray Observatory. Although the maps can be used for a variety of applications. the immediate goal is the generation of diffuse gamma-ray maps which can be used as a diffuse background/foreground for point source analysis of the data to be obtained from new high-energy gamma-ray missions like GLAST and AGILE. To generate the diffuse gamma maps from the raw EGRET maps, the point sources in the Third EGRET Catalog were subtracted out using the appropriate point spread function for each energy range. After that, smoothing was performed to minimize the effects of photon statistical noise. A smoothing length of 1 deg vas used for the Galactic plane maps. For the all-sky maps, a procedure was used which resulted in a smoothing length roughly equivalent to 4 deg. The result of this work is 16 maps of different energy intervals for absolute value of b < or equal to 20 deg, and 32 all-sky maps, 16 in equatorial coordinates (J2000) and 16 in Galactic coordinates.

Cillis, A, N.↗

The High Energy Telescope for STEREO

The IMPACT investigation for the STEREO Mission includes a complement of Solar Energetic Particle instruments on each of the two STEREO spacecraft. Of these instruments, the High Energy Telescopes (HETs) provide the highest energy measurements. This paper describes the HETs in detail, including the scientific objectives, the sensors, the overall mechanical and electrical design, and the on-board software. The HETs are designed to measure the abundances and energy spectra of electrons, protons, He, and heavier nuclei up to Fe in interplanetary space. For protons and He that stop in the HET, the kinetic energy range corresponds to approx. 13 to 40 MeV/n. Protons that do not stop in the telescope (referred to as penetrating protons) are measured up to approx. 100 MeV/n, as are penetrating He. For stopping He, the individual isotopes He-3 and He-4 can be distinguished. Stopping electrons are measured in the energy range approx. 0.7 - 6 MeV.

vonRosenvinge, Tycho↗

Compact high gradient ion accelerating structure

A high gradient linear accelerating structure can propagate high frequency waves at a negative harmonic to accelerate low-energy ions. The linear accelerating structure can provide a gradient of 50 MV/m for particles at a β of between 0.3 and 0.4. The high gradient structure can be a part of a linear accelerator configured to provide an energy range from an ion source to 450 MeV/u for 12 C 6+ and 250 MeV for protons. The linear accelerator can include one or more of the following sections: a radiofrequency quadrupole (RFQ) accelerator operating at the sub-harmonic of the S-band frequency, a high gradient structure for the energy range from ˜45 MeV/u to ˜450 MeV/u.

Kutsaev, Sergey↗

Graph Neural Networks for low-energy event classification & reconstruction in IceCube

IceCube, a cubic-kilometer array of optical sensors built to detect atmospheric and astrophysical neutrinos between 1 GeV and 1 PeV, is deployed 1.45 km to 2.45 km below the surface of the ice sheet at the South Pole. The classification and reconstruction of events from the in-ice detectors play a central role in the analysis of data from IceCube. Reconstructing and classifying events is a challenge due to the irregular detector geometry, inhomogeneous scattering and absorption of light in the ice and, below 100 GeV, the relatively low number of signal photons produced per event. To address this challenge, it is possible to represent IceCube events as point cloud graphs and use a Graph Neural Network (GNN) as the classification and reconstruction method. The GNN is capable of distinguishing neutrino events from cosmic-ray backgrounds, classifying different neutrino event types, and reconstructing the deposited energy, direction and interaction vertex. Based on simulation, we provide a comparison in the 1 GeV–100 GeV energy range to the current state-of-the-art maximum likelihood techniques used in current IceCube analyses, including the effects of known systematic uncertainties. For neutrino event classification, the GNN increases the signal efficiency by 18% at a fixed background rate, compared to current IceCube methods. Alternatively, the GNN offers a reduction of the background (i.e. false positive) rate by over a factor 8 (to below half a percent) at a fixed signal efficiency. For the reconstruction of energy, direction, and interaction vertex, the resolution improves by an average of 13%–20% compared to current maximum likelihood techniques in the energy range of 1 GeV–30 GeV. The GNN, when run on a GPU, is capable of processing IceCube events at a rate nearly double of the median IceCube trigger rate of 2.7 kHz, which opens the possibility of using low energy neutrinos in online searches for transient events.

47 OTHER INSTRUMENTATION↗

Capabilities of GRO/OSSE for observing solar flares

The launch of the Gamma Ray Observatory (GRO) near solar maximum makes solar flare studies early in the mission particularly advantageous. The Oriented Scintillation Spectrometer Experiment (OSSE) on GRO, covering the energy range 0.05 to 150 MeV, has some significant advantages over the previous generation of satellite-borne gamma-ray detectors for solar observations. The OSSE detectors will have about 10 times the effective area of the Gamma-Ray Spectrometer (GRS) on Solar Maximum Mission (SMM) for both photons and high-energy neutrons. The OSSE also has the added capability of distinguishing between high-energy neutrons and photons directly. The OSSE spectral accumulation time (approx. 4s) is four times faster than that of the SMM/GRS; much better time resolution is available in selected energy ranges. These characteristics will allow the investigation of particle acceleration in flares based on the evolution of the continuum and nuclear line components of flare spectra, nuclear emission in small flares, the anisotropy of continuum emission in small flares, and the relative intensities of different nuclear lines. The OSSE observational program will be devoted primarily to non-solar sources. Therefore, solar observations require planning and special configurations. The instrumental and operational characteristics of OSSE are discussed in the context of undertaking solar observations. The opportunities for guest investigators to participate in solar flare studies with OSSE is also presented.

Kurfess, J. D.↗

Design of the Experimental Exposure Conditions to Simulate Ionizing Radiation Effects on Candidate Replacement Materials for the Hubble Space Telescope

In this effort, experimental exposure times for monoenergetic electrons and protons were determined to simulate the space radiation environment effects on Teflon components of the Hubble Space Telescope. Although the energy range of the available laboratory particle accelerators was limited, optimal exposure times for 50 keV, 220 keV, 350 keV, and 500 KeV electrons were calculated that produced a dose-versus-depth profile that approximated the full spectrum profile, and were realizable with existing equipment. For the case of proton exposure, the limited energy range of the laboratory accelerator restricted simulation of the dose to a depth of .5 mil. Also, while optimal exposure times were found for 200 keV, 500 keV and 700 keV protons that simulated the full spectrum dose-versus-depth profile to this depth, they were of such short duration that the existing laboratory could not be controlled to within the required accuracy. In addition to the obvious experimental issues, other areas exist in which the analytical work could be advanced. Improved computer codes for the dose prediction- along with improved methodology for data input and output- would accelerate and make more accurate the calculational aspects. This is particularly true in the case of proton fluxes where a paucity of available predictive software appears to exist. The dated nature of many of the existing Monte Carlo particle/radiation transport codes raises the issue as to whether existing codes are sufficient for this type of analysis. Other areas that would result in greater fidelity of laboratory exposure effects to the space environment is the use of a larger number of monoenergetic particle fluxes and improved optimization algorithms to determine the weighting values.

Smith, L. Montgomery↗