Current status of visibility sensors for aviation

The development of a new increased range higher visibility was investigated. The visibility sensor that is currently is the Transmissometer. Current transmissometer technology provides only a factor of 10 dynamic range with a single base line. The FAA is preparing to install automated weather observing systems (AWOS) at many locations. These systems require visibilities up to approximately 5 miles. To use a transmissometer for this type of measurement, the base line must be about 1,000 feet; where alignment becomes very difficult to maintain. New technologies were developd for measuring visibility. Improved transmissometers, forward-scatter meters and back-scatter meters have become available. A current practical issue for visibility sensors is how to specify one that is good enough to meet the needs of aviation. The first question is what performance is required; how accurately must the sensor measure? Visibility sensors do not actually measure the visibility directly. The purpose of measuring the visibility is to predict what the pilot will see a considerable distance away from the sensor location. The atmosphere introduces considerable variation in the measurement and the basic sensor accuracy needed is difficult to define. The second question for high visibilities is what to use as the standard reference sensor. The third question pertains to the competitive procurement of visibility sensors, which is mandated at present. Two acceptance test procedures to be used to insure satisfactory sensor performance is examined.

David C. Burnham↗

IUE observations of comets P/Brorsen-Metcalf and Okazaki-Levy-Rudenko

Comet P/Brorsen-Metcalf (1989c) was observed with the International Ultraviolet Explorer (IUE) on several dates from 27 July 1989 through 5 August 1989; comet Okazaki-Levy-Rudenko (1989r) was observed in low dispersion with IUE on 2 and 22 December 1989. The water production rates for P/Brorsen-Metcalf were derived from OH measurements using the vectorial model of Festou (1981). Included also are the water production rates for Okazaki-Levy-Rudenko. Two estimates of the water production rate from the O I emission around 1304 A(octogons) are included. The ultraviolet continuum was not reliably measurable in comet P/Brorsen-Metcalf in most of the spectra, but Afp is approximately 30 cm for 2 August. For the comet Okazaki-Levy-Rudenko, an Afp = 50 cm was derived for 22 December. Both comets have very little dust compared to other recently observed comets. The ratio of CS to water production rates are presented. Relative to water, both comets had less CS than P/Halley in the same range of heliocentric distances. The CS production rates were obtained from a Haser model, assuming a short-lived parent (CS2). Because the dynamic range of the IUE spectrographs are limited, not all species can be measured in each spectrum. The P/Brorsen-Metcalf spectra from 31 July and 3 August were obtained from the NSSDC Archives. Due to the observing technique used for these spectra, the exposure time and hence, the brightnesses and derived quantities have a small uncertainty associated with them.

Roettger, E. E.↗

Effective Inflow Conditions for Turbulence Models in Aerodynamic Calculations

The selection of inflow values at boundaries far upstream of an aircraft is considered, for one- and two-equation turbulence models. Inflow values are distinguished from the ambient values near the aircraft, which may be much smaller. Ambient values should be selected first, and inflow values that will lead to them after the decay second; this is not always possible, especially for the time scale. The two-equation decay during the approach to the aircraft is shown; often, the time scale has been set too short for this decay to be calculated accurately on typical grids. A simple remedy for both issues is to impose floor values for the turbulence variables, outside the viscous sublayer, and it is argued that overriding the equations in this manner is physically justified. Selecting laminar ambient values is easy, if the boundary layers are to be tripped, but a more common practice is to seek ambient values that will cause immediate transition in boundary layers. This opens up a wide range of values, and selection criteria are discussed. The turbulent Reynolds number, or ratio of eddy viscosity to laminar viscosity has a huge dynamic range that makes it unwieldy; it has been widely mis-used, particularly by codes that set upper limits on it. The value of turbulent kinetic energy in a wind tunnel or the atmosphere is also of dubious value as an input to the model. Concretely, the ambient eddy viscosity must be small enough to preserve potential cores in small geometry features, such as flap gaps. The ambient frequency scale should also be small enough, compared with shear rates in the boundary layer. Specific values are recommended and demonstrated for airfoil flows

Spalart, Philippe R.↗

GPS/MEMS IMU/Microprocessor Board for Navigation

A miniaturized instrumentation package comprising a (1) Global Positioning System (GPS) receiver, (2) an inertial measurement unit (IMU) consisting largely of surface-micromachined sensors of the microelectromechanical systems (MEMS) type, and (3) a microprocessor, all residing on a single circuit board, is part of the navigation system of a compact robotic spacecraft intended to be released from a larger spacecraft [e.g., the International Space Station (ISS)] for exterior visual inspection of the larger spacecraft. Variants of the package may also be useful in terrestrial collision-detection and -avoidance applications. The navigation solution obtained by integrating the IMU outputs is fed back to a correlator in the GPS receiver to aid in tracking GPS signals. The raw GPS and IMU data are blended in a Kalman filter to obtain an optimal navigation solution, which can be supplemented by range and velocity data obtained by use of (l) a stereoscopic pair of electronic cameras aboard the robotic spacecraft and/or (2) a laser dynamic range imager aboard the ISS. The novelty of the package lies mostly in those aspects of the design of the MEMS IMU that pertain to controlling mechanical resonances and stabilizing scale factors and biases.

Gender, Thomas K.↗

Alignment Jig for the Precise Measurement of THz Radiation

A miniaturized instrumentation package comprising a (1) Global Positioning System (GPS) receiver, (2) an inertial measurement unit (IMU) consisting largely of surface-micromachined sensors of the microelectromechanical systems (MEMS) type, and (3) a microprocessor, all residing on a single circuit board, is part of the navigation system of a compact robotic spacecraft intended to be released from a larger spacecraft [e.g., the International Space Station (ISS)] for exterior visual inspection of the larger spacecraft. Variants of the package may also be useful in terrestrial collision-detection and -avoidance applications. The navigation solution obtained by integrating the IMU outputs is fed back to a correlator in the GPS receiver to aid in tracking GPS signals. The raw GPS and IMU data are blended in a Kalman filter to obtain an optimal navigation solution, which can be supplemented by range and velocity data obtained by use of (l) a stereoscopic pair of electronic cameras aboard the robotic spacecraft and/or (2) a laser dynamic range imager aboard the ISS. The novelty of the package lies mostly in those aspects of the design of the MEMS IMU that pertain to controlling mechanical resonances and stabilizing scale factors and biases.

Javadi, Hamid H.↗

JPSS-2 VIIRS Day-Night Band Pre-launch Radiometric Calibration and Performance

The first two flight models of the Visible Infrared Imaging Radiometer Suite (VIIRS) instrument continue to operate onboard the Suomi National Polar-orbiting Partnership (S-NPP) and NOAA-20 spacecrafts. The third flight model is set to be launched as one of a complement of instruments onboard the Joint Polar–orbiting Satellite System-2 (JPSS-2) satellite. In addition to its 14 reflective solar bands and 7 thermal emissive bands, VIIRS has a unique Day-Night Band (DNB). The DNB is a panchromatic imager based on CCD detectors, covering a spectral range of about 500 – 900 nm. The DNB is made up of three gain stages, allowing the sensor to operate over a large dynamic range (3×10(−9) - 0.02 W⁄cm(2)/sr). As part of VIIRS pre-launch ground testing, the DNB has been characterized to determine its functionality and performance under a space-like environment. The results are compared against the design specification and to previous VIIRS flight models when applicable. This paper presents a comprehensive summary of the VIIRS DNB prelaunch testing and the results of radiometric and spectral assessments. The expected impact to on-orbit operations and calibrated data products are also discussed.

Infrared Imaging Radiometer Suite (VIIRS)↗

All-digital phase-lock loops for noise-free signals

Bit-synchronizers utilize all-digital phase-lock loops that are referenced to a high frequency digital clock. Phase-lock loop of first design acquires frequency within nominal range and tracks phase; second design is modified for random binary data by addition of simple transition detector; and third design acquires frequency over wide dynamic range.

Anderson, T. O.↗

High performance visible and near-infrared charge-coupled-device array for spectroscopy applications

This paper describes the design and performance of a scientific CCD array for use in NASA's Shuttle Image Spectrometer Experiment. The device is a four-phase, buried-channel CCD structure that operates in the frame-transfer mode. The sensor consists of 64 x 404 pixels, has a 100 percent fill factor, and operates in the visible and near-infrared spectral regions. In operation, the 404 horizontal elements provide spatial information, while the 64 vertical elements give spectral information covering the wavelength range of 400 to 1000 nm in 10 nm increments. The high full-well capacity of each pixel and low noise floor yield a dynamic range of more than 95 dB. In addition, the device has been designed to have good linearity characteristics. The unique dual-output structure allows a horizontal row to be read out to the right or to the left, or it can be split from the middle to both right and left output circuits simultaneously for high speed applications. The power dissipation of the device is about 60 mW.

Wang, Weng-Lyang↗

[Microfabricated X-ray Optics Technology Development for the Constellation X-Mission]

MIT has previously developed advanced methods for the application of silicon microstructures (so-called microcombs) in the precision assembly of foil x-ray optics in support of the Constellation-X Spectroscopy X-ray Telescope (SXT) technology development at the NASA Goddard Space Flight Center (GSFC). During the first year of the above Cooperative Agreement, MIT has developed a new, mature, potentially high- yield process for the manufacturing of microcombs that can be applied to a range of substrates independent of thickness. MIT also developed techniques to extract microcomb accuracy from an assembly truss metrology test stand and to extend the dynamic range of its Shack-Hartmann foil metrology tool. The placement repeatability of foil optics with microcombs in the assembly truss has been improved by a factor of two to approximately 0.15 micron. This was achieved by electric contact determination in favor of determining contact through force measurements. Development work on a stress-free thin foil holder was also supported by this agreement and successfully continued under a different grant.

Schattenburg, Mark L.↗

Update of S-NPP VIIRS Thermal Emissive Bands Radiometric Calibration Stability Monitoring Using the Moon

The Suomi-NPP VIIRS thermal emissive bands (TEB) are radiometrically calibrated on-orbit with reference to an onboard blackbody (BB) regularly operated at approximately 292.5 K. The calibration stability at other temperature ranges can be evaluated based on the observations of remote targets with stable thermal properties, such as the Moon. VIIRS has scheduled viewings of the Moon on a nearly monthly basis at a phase angle of nearly -51 degrees. In this study, the brightness temperatures (BT) of the lunar surface retrieved using the detector gain coefficients calibrated with the BB are trended to monitor the calibration stability of VIIRS TEB. Since the Lunar surface temperatures are spatially non-uniform and vary greatly with the photometric geometry, the BT trending must be based on the same regions of the Moon under the same solar illumination condition. Also, the TEB lunar images are always partially saturated because the highest lunar surface temperatures are beyond the dynamic range of all VIIRS TEB detectors. Therefore, a temporally invariant dynamic mask is designed to clip a fraction of the lunar images corresponding to the regions of the Moon that may saturate the detector at any lunar event. The BT of the remaining hottest pixels are then trended. Results show that, since the launch of VIIRS to mid-2016, the radiometric calibration of all TEB detectors has been stable within 0.4 K at the BT range of as high as 350 K.

Wang, Zhipeng↗

Physics-informed machine learning of the Lagrangian dynamics of velocity gradient tensor

Reduced models describing the Lagrangian dynamics of the velocity gradient tensor (VGT) in homogeneous isotropic turbulence (HIT) are developed under the physics-informed machine learning (PIML) framework. We consider the VGT at both Kolmogorov scale and coarse-grained scale within the inertial range of HIT. Building reduced models requires resolving the pressure Hessian and subfilter contributions, which is accomplished by constructing them using the integrity bases and invariants of the VGT. The developed models can be expressed using the extended tensor basis neural network (TBNN) introduced by Ling et al. [J. Fluid Mech. 807, 155 (2016)]. Physical constraints, such as Galilean invariance, rotational invariance, and incompressibility condition, are thus embedded in the models explicitly. Our PIML models are trained on the Lagrangian data from a high-Reynolds number direct numerical simulation (DNS). To validate the results, we perform a comprehensive out-of-sample test. We observe that the PIML model provides an improved representation for the magnitude and orientation of the small-scale pressure Hessian contributions. Statistics of the flow, as indicated by the joint PDF of second and third invariants of the VGT, show good agreement with the “ground-truth” DNS data. A number of other important features describing the structure of HIT are reproduced by the model successfully. We have also identified challenges in modeling inertial range dynamics, which indicates that a richer modeling strategy is required. This helps us identify important directions for future research, in particular towards including inertial range geometry into the TBNN.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Single Pixel Characterization of X-Ray TES Microcalorimeter Under AC Bias at MHz Frequencies

In this paper we present the progress made at SRON in the read-out of GSFC x-ray transition-edge sensor (TES) micro-calorimeters in the frequency domain. The experiments reported so far, whose aim was to demonstrate an energy resolution of 2eV at 6 keV with a TES acting as a modulator, were carried out at frequencies below 700 kHz using a standard flux locked loop (FLL) SQUID read-out scheme. The TES read-out suffered from the use of sub-optimal circuit components, large parasitic inductances, low quality factor resonators and poor magnetic field shielding. We have developed a novel experimental set-up, which allows us to test several read-out schemes in a single cryogenic run. In this set-up, the TES pixels are coupled via superconducting transformers to 18 high-Q lithographic LC filters with resonant frequencies ranging between 2 and 5 MHz. The signal is amplified by a two-stage SQUID current sensor and baseband feedback is used to overcome the limited SQUID dynamic range. We study the single pixel performance as a function of TES bias frequency, voltage and perpendicular magnetic field.

Gottardi, L.↗

Studying the Formation and Development of Molecular Clouds: With the CCAT Heterodyne Array Instrument (CHAI)

Surveys of all different types provide basic data using different tracers. Molecular clouds have structure over a very wide range of scales. Thus, "high resolution" surveys and studies of selected nearby clouds add critical information. The combination of large-area and high resolution allows Increased spatial dynamic range, which in turn enables detection of new and perhaps critical morphology (e.g. filaments). Theoretical modeling has made major progress, and suggests that multiple forces are at work. Galactic-scale modeling also progressing - indicates that stellar feedback is required. Models must strive to reproduce observed cloud structure at all scales. Astrochemical observations are not unrelated to questions of cloud evolution and star formation but we are still learning how to use this capability.

heterodyne sub-millimeter arrays↗

Metal-embedded fiber optic sensor packaging and signal demodulation scheme towards high-frequency dynamic measurements in harsh environments

Optical fiber-based sensors are commonly used for industrial monitoring and control processes due to their small size, resistance to electromagnetic interference, and ability to perform a wide variety of high-precision measurements. However, implementing optical fiber sensors in harsh environments is challenging because they are small and fragile. Proper packaging of fiber-optic sensors could extend their use to harsh environments, including at high temperature and under high radiation. Furthermore, conventional fiber optic-based measurement systems often use computationally expensive signal processing algorithms which hinder their use in high-frequency dynamic applications. This work reports on the design of an optical fiber-pressure sensor system based on low-coherence interferometry that uses a metal-embedded optical fiber to provide a robust sensor package. Additionally, a novel phase demodulation scheme is proposed to extract length changes from the deformation of a thin diaphragm within a Fabry–Pérot cavity to measure pressure. The sensor has been tested to ±100 kPa, has a theoretical linear response over a 270 kPa dynamic range (24 dB maximum signal-to-noise ratio), and can resolve pressure transients up to 3910 kPa/s. Sampling at 100 kHz, the present sensor can resolve 2 kPa dynamic pressures at frequencies up to 2 kHz. Faster transients on the order of tens to hundreds of kHz can theoretically be resolved at the expense of decreasing the maximum resolvable amplitude. A methodology for designing a LCI pressure sensor for a given application is outlined based on the limitations imposed by the Nyquist criterion, the diaphragm's resonant frequency, the LCI optoelectronics, and the phase demodulation scheme. The sensor is the first to implement a low-coherence light source and a Fabry–Pérot interferometer designed to provide real-time high-fidelity pressure measurements using a metal-embedded optical fiber. The demonstrated sensor provides a platform for sensing in harsh conditions such as in nuclear and energy applications.

47 OTHER INSTRUMENTATION↗

Spectroscopic imaging of the thermosphere from the Space Shuttle

The design features, performance characteristics, and intended missions for the Imaging Spectrometric Observatory scheduled to fly on the first Spacelab Shuttle mission in 1983 are described. The instrument comprises an array of five imaging spectrometers covering the spectral range 300-1200 A. The spectrometers operate simultaneously, using CCDs as collector elements. Resolution on the first flight will be limited to 3 A, with coverage to containing the dynamic range from nocturnal signals to the bright earth. A minicomputer in the Spacelab will permit crewmember interaction with the measurements, while data will be telemetered in real-time to a ground station. Initial mission objectives include observations of dayglow, nightglow, and twilightglow over the full wavelength range capability.

Torr, M. R.↗

Tuning Organic Electrochemical Transistor Threshold Voltage using Chemically Doped Polymer Gates

Organic electrochemical transistors (OECTs) have shown promise as transducers and amplifiers of minute electronic potentials due to their large transconductances. Tuning the OECT threshold voltage is important to achieve low-powered devices with amplification properties within the desired operational voltage range. However, traditional design approaches have struggled to decouple channel and materials properties from threshold voltage, thereby compromising on several other OECT performance metrics, such as electrochemical stability, transconductance, and dynamic range. In this work, simple solution-processing methods are utilized to chemically dope polymer gate electrodes, thereby controlling their work function, which in turn tunes the operation voltage range of the OECTs without perturbing their channel properties. Chemical doping of initially air-sensitive polymer electrodes further improves their electrochemical stability in ambient conditions. Thus, OECTs that are simultaneously low-powered and electrochemically resistant to oxidative side reactions under ambient conditions are demonstrated. Furthermore, this approach shows that threshold voltage, which is once interwoven with other OECT properties, can in fact be an independent design parameter, expanding the design space of OECTs.

chemical doping↗

Optical fiber sensors for the non-destructive evaluation of materials

The operation of the modal domain vibration sensor was demonstrated in several simple vibrational systems. Two apparent advantages are the sensors bandwidth and sensitivity. An inherent drawback of standard vibration detection devices is their rapid cost increase with high frequency bandwidth. This sensor showed consistent response in the freqency range of 1.5 to 400 Hz. By imparting very small but measurable excitations in the structures, the sensors ability to respond to very low order vibration induced strain was established. Dynamic ranges on the order of 18 to 22 dB for the CF beam and string systems respectively were observed. The sensor itself represents a very simple system: a coherent source, a single fiber and a low bandwidth detector. The inherent advantages of ruggedness and immunity to external radiation can also be added. Finally, the sensor minimally impairs structural motion through loading, an advantage in monitoring small vibrations or lightweight structures. Some drawbacks of the sensor are also noted.

Source record↗

High-speed analog fiber optic links for satellite communication

Large-aperture phased array antennas operating at millimeter wave frequencies are designed for space-based communications and imaging. Array elements are comprised of active transmit/receive (T/R) modules which are linked to the central processing unit through a high-speed fiberoptic network. This paper demonstrates optical control of active modules for satellite communication at 24 GHz. An approach called T/R level data mixing, which utilizes fiberoptic transmission of a data signal to individual T/R modules to be upconverted by an optically synchronized local oscillator, is demonstrated at 24 GHz. A free-running HEMT oscillator, used as local oscillator at 24 GHz, is synchronized using indirect subharmonic optical injection locking over a locking range of 14 MHz. Results of data link performance over 500-1000 MHz is also reported in terms of gain-bandwidth, linearity and third-order intercept, sensitivity, and dynamic range.