Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Drop size distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Characterization of Large Drop Velocity in the NASA Icing Research Tunnel

This paper presents experimental work conducted in the Icing Research Tunnel at NASA Glenn Research Center to characterize the velocity of large drops in the test section. Some icing spray clouds with large drops were generated with Mod1 nozzles at low nozzle air pressure of 2 to 4 psig for various tunnel air speeds. Drop diameters and drop velocities were measured via high-resolution imaging with a Particle Imaging Particle Tracking Velocimetry probe developed by Artium Technologies. The probe was mounted at four different locations aligned with the centerline of the test section from near the end of the contraction to the constant height test section part of the tunnel. CFD analyses were performed. It showed that the probe head geometry affects the local air flow in the measurement area of the probe between the prongs and in front of the probe. Initial analysis of the air velocity data during the test also indicated that the probe mounting stand has blockage effect on the local tunnel air velocity measurement by a pitot-static probe affixed on the mounting plate next to the stand. Those findings were later verified in the Icing Research Tunnel using a new pitot-static probe design with a linear motion system to measure the local tunnel air velocity with and without the probe. As a result, additional drop trajectory simulations were performed with the airflow moving towards the probe head with a Langmuir-D 7-bin distribution cloud containing large drops. The simulation results helped identify a critical drop-size threshold of 300 μm above which the velocities of larger drops are negligibly affected by the adverse pressure gradient generated by the probe head due to their large drop inertia. From the dimensional analysis of the drop velocity measurement data obtained, it showed that at the tunnel test section reference location a generalized empirical correlation was developed for the non-dimensional drop velocity as a function of the non-dimensional corrected drop diameter independent of the actual spraybar pressure settings and the tunnel air speeds. The generalized curve-fit correlation showed that the drop velocity was universally asymptotic to about 86 percent of the corresponding tunnel air speed at the test section reference location for the largest drop diameter captured by the probe. Further evaluation of this correlation is recommended to assess its applicability for Supercooled Large Drop icing scaling applications in the Icing Research Tunnel.

SLD↗

Simulations of Evaporating Multicomponent Fuel Drops

A paper presents additional information on the subject matter of Model of Mixing Layer With Multicomponent Evaporating Drops (NPO-30505), NASA Tech Briefs, Vol. 28, No. 3 (March 2004), page 55. To recapitulate: A mathematical model of a three-dimensional mixing layer laden with evaporating fuel drops composed of many chemical species has been derived. The model is used to perform direct numerical simulations in continuing studies directed toward understanding the behaviors of sprays of liquid petroleum fuels in furnaces, industrial combustors, and engines. The model includes governing equations formulated in an Eulerian and a Lagrangian reference frame for the gas and drops, respectively, and incorporates a concept of continuous thermodynamics, according to which the chemical composition of a fuel is described by use of a distribution function. In this investigation, the distribution function depends solely on the species molar weight. The present paper reiterates the description of the model and discusses further in-depth analysis of the previous results as well as results of additional numerical simulations assessing the effect of the mass loading. The paper reiterates the conclusions reported in the cited previous article, and states some new conclusions. Some new conclusions are: 1. The slower evaporation and the evaporation/ condensation process for multicomponent-fuel drops resulted in a reduced drop-size polydispersity compared to their single-component counterpart. 2. The inhomogeneity in the spatial distribution of the species in the layer increases with the initial mass loading. 3. As evaporation becomes faster, the assumed invariant form of the molecular- weight distribution during evaporation becomes inaccurate.

Bellan, Josette↗

Contrasting responses to climate change at Himalayan treelines revealed by population demographics of two dominant species

Abstract Alpine treelines are expected to shift upward due to recent climate change. However, interpretation of changes in montane systems has been problematic because effects of climate change are frequently confounded with those of land use changes. The eastern Himalaya, particularly Langtang National Park, Central Nepal, has been relatively undisturbed for centuries and thus presents an opportunity for studying climate change impacts on alpine treeline uncontaminated by potential confounding factors. We studied two dominant species, Abies spectabilis (AS) and Rhododendron campanulatum (RC) , above and below the treeline on two mountains. We constructed 13 transects, each spanning up to 400 m in elevation, in which we recorded height and state (dead or alive) of all trees, as well as slope, aspect, canopy density, and measures of anthropogenic and animal disturbance. All size classes of RC plants had lower mortality above treeline than below it, and young RC plants (<2 m tall) were at higher density above treeline than below. AS shows little evidence of a position change from the historic treeline, with a sudden extreme drop in density above treeline compared to below. Recruitment, as measured by size–class distribution, was greater above treeline than below for both species but AS is confined to ~25 m above treeline whereas RC is luxuriantly growing up to 200 m above treeline. Synthesis . Evidence suggests that the elevational limits of RC have shifted upward both because (a) young plants above treeline benefited from facilitation of recruitment by surrounding vegetation, allowing upward expansion of recruitment, and (b) temperature amelioration to mature plants increased adult survival. We predict that the current pure stand of RC growing above treeline will be colonized by AS that will, in turn, outshade and eventually relegate RC to be a minor component of the community, as is the current situation below the treeline.

54 ENVIRONMENTAL SCIENCES↗

Computational Icing Risk Analysis of the D8 "Double Bubble" Aircraft

A computational icing risk analysis utilizing LEWICE3D was performed for the D8 Double Bubble aircraft. A variety of discrete drop sizes spanning the Appendix C and O regimes were simulated. For computational efficiency a 50-bin global discretization was produced and projected onto the distributions of interest, eliminating redundant simulations. The trajectory and impingement characteristics for discrete drop diameters were analyzed to help understand the behavior of the water drops in the presence of a complex flow field. The collection efficiency results for the discrete drop diameters were then weighted by their contributions to the total water content of six different continuous distributions and subsequently superposed to approximate these curves. Results indicate that significant variation in impingement exists as a function of drop diameter for complex wing body geometries, and that current discretization practices may be insufficient to accurately predict water collection on certain regions of the aircraft. Results also indicate that the Appendix O distributions, specifically those with considerable water content at large drops, generates water collection patterns that are markedly different from distributions representative of Appendix C.

icing↗

Computational Icing Risk Analysis of the D8 "Double Bubble" Aircraft

A computational icing risk analysis utilizing LEWICE3D was performed for the D8 Double Bubble aircraft. A variety of discrete drop sizes spanning the Appendix C and O regimes were simulated. For computational efficiency a 50-bin global discretization was produced and projected onto the distributions of interest, eliminating redundant simulations. The trajectory and impingement characteristics for discrete drop diameters were analyzed to help understand the behavior of the water drops in the presence of a complex flow field. The collection efficiency results for the discrete drop diameters were then weighted by their contributions to the total water content of six different continuous distributions and subsequently superposed to approximate these curves. Results indicate that significant variation in impingement exists as a function of drop diameter for complex wing body geometries, and that current discretization practices may be insufficient to accurately predict water collection on certain regions of the aircraft. Results also indicate that the Appendix O distributions, specifically those with considerable water content at large drops, generates water collection patterns that are markedly different from distributions representative of Appendix C.

Porter, Christopher E.↗

Venturi nozzle effects on fuel drop size and nitrogen oxide emissions

The effect of a venturi nozzle on the Sauter mean diameter of a water spray produced by a simplex pressure atomizing injector in a swirling airflow was determined. A Malvern particle and droplet size distribution analyzer, Type S.T. 1800, was used to measure D sub 32 of the water sprays. The water spray was studied at ambient temperature (293 K) and atmospheric pressure. The venturi reduced D sub 32 by an average of 30 percent when installed with a simplex injector and air swirler. The venturi primarily improved atomization of the injector spray by increasing relative air velocity. The small drop size enhanced vaporization and therefore decreased oxides of nitrogen in a combustor. The decrease in drop size provided by the addition of a venturi explains the results obtained in a previous small scale research combustor wherein NOx emission indices decreased as a result of this hardware modification.

Johnson, S. M.↗

Coastal Cloud Chemistry during EPCAPE Field Campaign Report

For this campaign, Principal Investigator Markus Petters deployed a suite of instruments inside Lynn Russell’s container that was sited at Mt. Soledad during the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE) campaign. Funding for this activity was provided by National Science Foundation Award 2410536. The instrument rack (Figure 1) included a differential mobility analyzer, a condensation particle counter, a portable optical particle spectrometer, and a continuous flow diffusion cloud condensation nuclei counter (CCN). The instruments sampled from a counterflow virtual impactor (CVI) inlet and an isokinetic inlet. The measurements provided aerosol size distribution, size-resolved CCN activity, and denuded versus undenuded CCN activity of aerosols and cloud drop residuals.

54 ENVIRONMENTAL SCIENCES↗

One-Dimensional Spontaneous Raman Measurements of Temperature Made in a Gas Turbine Combustor

The NASA Glenn Research Center is working with the aeronautics industry to develop highly fuel-efficient and environmentally friendly gas turbine combustor technology. This effort includes testing new hardware designs at conditions that simulate the high-temperature, high-pressure environment expected in the next-generation of high-performance engines. Glenn has the only facilities in which such tests can be performed. One aspect of these tests is the use of nonintrusive optical and laser diagnostics to measure combustion species concentration, fuel/air ratio, fuel drop size, and velocity, and to visualize the fuel injector spray pattern and some combustion species distributions. These data not only help designers to determine the efficacy of specific designs, but provide a database for computer modelers and enhance our understanding of the many processes that take place within a combustor. Until recently, we lacked one critical capability, the ability to measure temperature. This article summarizes our latest developments in that area. Recently, we demonstrated the first-ever use of spontaneous Raman scattering to measure combustion temperatures within the Advanced Subsonics Combustion Rig (ASCR) sector rig. We also established the highest rig pressure ever achieved for a continuous-flow combustor facility, 54.4 bar. The ASCR facility can provide operating pressures from 1 to 60 bar (60 atm). This photograph shows the Raman system setup next to the ASCR rig. The test was performed using a NASA-concept fuel injector and Jet-A fuel over a range of air inlet temperatures, pressures, and fuel/air ratios.

Hicks, Yolanda R.↗

An Examination of the Impact of Drizzle Drops on Satellite-Retrieved Effective Particle Sizes

In general, cloud effective droplet radii are remotely sensed in the near-infrared using the assumption of a monomodal droplet size distribution. It has been observed in many instances, especially in relatively pristine marine environments, that cloud effective droplet radii derived from satellite data often exceed 15 m or more. Comparisons of remotely sensed and in situ retrievals indicate that the former often overestimates the latter in clouds with drizzle-size droplets. To gain a better understanding of this discrepancy, this paper performs a theoretical and empirical evaluation of the impact of drizzle drops on the derived effective radius.

Minnis, Patrick↗

Clarifying remotely-retrieved precipitation of shallow marine clouds from the NSF/NCAR Gulfstream V

Precipitation is a key process within the shallow cloud lifecycle. The Cloud System Evolution in the Trades (CSET) campaign included the first deployment of a 94 GHz Doppler radar and 532 nm lidar. Despite a larger sampling volume, initial mean radar/lidar retrieved rain rates (Schwartz et al. 2019) based on the upward-pointing remote sensor datasets are systematically less than those measured by in-situ precipitation probes in the cumulus regime. Subsequent retrieval improvements produce rainrates that compare better to in-situ values, but still underestimate. Retrieved shallow cumulus drop sizes can remain too small and too few, with an overestimated shape parameter narrowing the raindrop size distribution too much. Three potential causes for the discrepancy are explored: the gamma functional fit to the dropsize distribution, attenuation by rain and cloud water, and an underaccounting of Mie dampening of the reflectivity. A truncated exponential fit may represent the dropsizes below a showering cumulus cloud more realistically, although further work would be needed to fully evaluate the impact of a different dropsize representation upon the retrieval. The rain attenuation is within the measurement uncertainty of the radar. Mie dampening of the reflectivity is shown to be significant, in contrast to previous stratocumulus campaigns with lighter rain rates, and may be difficult to constrain well with the remote measurements. An alternative approach combines an a priori determination of the dropsize distribution width based on the in-situ data with the mean radar Doppler velocity and reflectivity. This can produce realistic retrievals, although a more comprehensive assessment is needed to better characterize the retrieval errors.

54 ENVIRONMENTAL SCIENCES↗

Collective effects of temperature gradients and gravity on droplet coalescence

The interaction and coalescence of small spherical drops in dilute, homogeneous dispersions are considered theoretically under conditions, where drop motion results from gravity settling and thermocapillary migration acting simultaneously. A trajectory analysis is used to predict pairwise collision rates, and population dynamics equations are solved to predict the time evolution of the droplet size distribution. The rate of droplet collisions and growth may be reduced dramatically by antiparallel alignment of the gravitational and thermocapillary velocities. For such antiparallel alignment with the gravitational relative velocity exceeding the thermocapillary relative velocity for two widely separated drops, there is a 'collision-forbidden region' in parameter space. This occurs because the gravitational relative velocity decays more rapidly with decreasing separation distance between the drops than does the thermocapillary relative velocity, and so the resultant relative velocity along the line-of-centers from these two sources combined becomes zero at a finite separation and the drops are unable to collide. As a result, small drops which initially collide and coalesce due to thermocapillary motion will only grow until they reach a critical size for which the oppositely directed gravitational motion balances the thermocapillary motion.

Zhang, Xiaoguang↗

A survey of manufacturers of solar thermal energy systems

Sixty-seven firms that had received funding for development of solar thermal energy systems (STES) were surveyed. The effect of the solar thermal technology systems program in accelerating (STES) were assessed. The 54 firms still developing STES were grouped into a production typology comparing the three major technologies with three basic functions. It was discovered that large and small firms were developing primarily central receiver systems, but also typically worked on more than one technology. Most medium-sized firms worked only on distributed systems. Federal support of STES was perceived as necessary to allow producers to take otherwise unacceptable risks. Approximately half of the respondents would drop out of STES if support were terminated, including a disproportionate number of medium-sized firms. A differentiated view of the technology, taking into account differing firm sizes and the various stages of technology development, was suggested for policy and planning purposes.

Levine, N.↗

Comparison of Raindrop Size Distribution Measurements by Collocated Disdrometers

An impact-type Joss-Waldvogel disdrometer (JWD), a two-dimensional video disdrometer (2DVD), and a laser optical OTT Particle Size and Velocity (PARSIVEL) disdrometer (PD) were used to measure the raindrop size distribution (DSD) over a 6-month period in Huntsville, Alabama. Comparisons indicate event rain totals for all three disdrometers that were in reasonable agreement with a reference rain gauge. In a relative sense, hourly composite DSDs revealed that the JWD was more sensitive to small drops (,1 mm), while the PD appeared to severely underestimate small drops less than 0.76mm in diameter. The JWD and 2DVD measured comparable number concentrations of midsize drops (1-3mm) and large drops (3-5 mm), while the PD tended to measure relatively higher drop concentrations at sizes larger than 2.44mm in diameter. This concentration disparity tended to occur when hourly rain rates and drop counts exceeded 2.5mm/h and 400/min, respectively. Based on interactions with the PD manufacturer, the partially inhomogeneous laser beam is considered the cause of the PD drop count overestimation. PD drop fall speeds followed the expected terminal fall speed relationship quite well, while the 2DVD occasionally measured slower drops for diameters larger than 2.4mm, coinciding with events where wind speeds were greater than 4m/s. The underestimation of small drops by the PD had a pronounced effect on the intercept and shape of parameters of gamma-fitted DSDs, while the overestimation of midsize and larger drops resulted in higher mean values for PD integral rain parameters

disdrometers↗

Particle diagnostics and turbulence measurements in a confined isothermal liquid spray

An experimental study of the behavior and structure of a liquid spray immersed in a strong swirling field is reported. In order to simulate some of the aerodynamic conditions experienced by a spray in a model combustor, an experimental setup using an acrylic chamber, a vane-type swirler, and separate air supplies for both the secondary air and swirl air were integrated to perform the experiments in the wind tunnel. The effect of the swirling flow on the original spray cone is to widen it substantially, and to provide a vortex core where intense mixing results in large changes in particle size distribution and in particle number density. Outside the recirculation region, both the D32 and N sub d attain more uniform values. Inside the recirculation region, the mean axial velocity averaged over all the drop sizes has larger values than the mean air velocity. Outside the recirculation region, both the particles and the air exhibit virtually the same velocities. The turbulence measurements showed regions of high turbulence intensity in the boundaries of the recirculation region.

Brena De La Rosa, A.↗

Update on the NASA Glenn Propulsion Systems Lab Icing and Ice Crystal Cloud Characterization (2017)

NASA Glenn's Propulsion Systems Lab, an altitude engine test facility, generates icing clouds with a spray system. While the spray system is used mostly to create ice crystal clouds (Appendix D/P), the 2017 cloud characterization effort added the requirement to produce exactly supercooled liquid clouds in Appendix C and Appendix O. Success was demonstrated to supercool the largest drops at the warmest conditions, but not freeze out the smallest drops at the coldest conditions. This paper documents primarily the total water content characterization methodology and results from an Iso-Kinetic Probe in ice crystals and Multi-Wire sensor in supercooled liquid, along with the cloud uniformity provided by light extinction tomography. Particle size distribution results from High Speed Imaging probes and a Phase Doppler Interferometer are discussed. Also, a new numerical model for tracking the thermodynamics of the air-drop interactions in PSL from the plenum toward the cloud characterization plane are noted. Both of these latter topic are more fully documented in companion papers.

Calibration↗

Laser velocimetry measurements in a gas turbine research combustor

The effects of turbulence on the production of pollutant species in a gas-turbine research combustor are studied using laser diffraction velocimetry (LDV) techniques. Measurements that were made in the primary combustion zone include mean velocity, rms velocity fluctuations, velocity probability distributions, and autocorrelation functions. A unique combustor design provides relatively uniform flow conditions and independent control of drop size, equivalence ratio, inlet temperature, and combustor pressure. Parameters which characterize the nature of the spray combustion (i.e., whether single droplet or group combustion occurs), were determined from the LDV data. Turbulent diffusivity (eddy viscosity) reaches a value of 2930 sq cm/sec, corresponding to a convective integral length scale of 1.8 cm. The group combustion number, based on turbulent diffusivity, is measured to be 6.2

Driscoll, J. F.↗

Microphysical modeling of cirrus. 1: Comparison with 1986 FIRE IFO measurements

We have used a one-dimensional model of cirrus formation to study the development of cirrus clouds during the 1986 First ISCCP (International Satellite Cloud Climatology Project) Regional Experiment (FIRE) intensive field observations (IFO). The cirrus model includes microphysical, dynamical, and radiative processes. Sulfate aerosols, solution drops, ice crystals, and water vapor are all treated as interactive elements in the model. Ice crystal size distributions are fully resolved based on calculations of homogeneous freezing nucleation, growth by water vapor deposition, evaporation, coagulation, and vertical transport. We have focused on the cirrus observed on November 1, 1986. Vertical wind speed for the one-dimensional simulation is taken from a mesoscale model simulation for the appropriate time period. The mesoscale model simulation suggested that strong upward motions over Wyoming and subsequent horizontal transport of upper level moisture were responsible for the cirrus observed over Wisconsin on this date. We assumed that our one-dimensional model could be used to represent a vertical column moving from Wyoming to Wisconsin over a period of several hours. Ice crystal nucleation occurs in our model in the 8 to 10-km region as a result of the strong updrafts (and cooling) early in the simulation. Growth, coagulation, and sedimentation of these ice crystals result in a broad cloud region (5-10 km thick) with an optical depth of 1-2 after a few hours, in agreement with the FIRE measurements. Comparison with aircraft microphysical measurements made over Wisconsin indicates that the simulation generated reasonable ice water content, but the predicted ice number densities are too low, especially for radii less than about 50 microns. Sensitivity tests suggest that better agreement between simulated and observed microphysical properties is achieved if the nucleation rate is higher or stronger vertical mixing (perhaps associated with multidimensional motions) is present.

Jensen, Eric J.↗