Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Distribution systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

An efficient algorithm for estimating noise covariances in distributed systems

An efficient computational algorithm for estimating the noise covariance matrices of large linear discrete stochatic-dynamic systems is presented. Such systems arise typically by discretizing distributed-parameter systems, and their size renders computational efficiency a major consideration. The proposed adaptive filtering algorithm is based on the ideas of Belanger, and is algebraically equivalent to his algorithm. The earlier algorithm, however, has computational complexity proportional to p to the 6th, where p is the number of observations of the system state, while the new algorithm has complexity proportional to only p-cubed. Further, the formulation of noise covariance estimation as a secondary filter, analogous to state estimation as a primary filter, suggests several generalizations of the earlier algorithm. The performance of the proposed algorithm is demonstrated for a distributed system arising in numerical weather prediction.

Dee, D. P.↗

Support for User Interfaces for Distributed Systems

An extensible Java(TradeMark) software framework supports the construction and operation of graphical user interfaces (GUIs) for distributed computing systems typified by ground control systems that send commands to, and receive telemetric data from, spacecraft. Heretofore, such GUIs have been custom built for each new system at considerable expense. In contrast, the present framework affords generic capabilities that can be shared by different distributed systems. Dynamic class loading, reflection, and other run-time capabilities of the Java language and JavaBeans component architecture enable the creation of a GUI for each new distributed computing system with a minimum of custom effort. By use of this framework, GUI components in control panels and menus can send commands to a particular distributed system with a minimum of system-specific code. The framework receives, decodes, processes, and displays telemetry data; custom telemetry data handling can be added for a particular system. The framework supports saving and later restoration of users configurations of control panels and telemetry displays with a minimum of effort in writing system-specific code. GUIs constructed within this framework can be deployed in any operating system with a Java run-time environment, without recompilation or code changes.

Eychaner, Glenn↗

Resilience Metrics for Building-Level Electrical Distribution Systems with Energy Storage: Preprint

The energy system infrastructure that delivers power to a building's loads needs to be resilient, such that it can withstand and recover from extreme outages (e.g., grid faults that leave millions of people without power during severe weather events). Building-level electrical distribution systems (BEDSs) distribute power from a building's energy sources - including the grid, solar photovoltaic (PV) panels, and batteries - to its loads, including lighting, HVAC, and plug loads. BEDS with storage can provide resilience by distributing local electricity supply to critical loads during an outage. Quantitative metrics are needed to assess the resilience improvements associated with new BEDS and storage system technologies. In this paper, we apply an existing metric, the probability of outage survival curve (POSC), to BEDS with storage and propose a set of novel metrics that improve upon POSC. Through a simulation-based case study, we demonstrate how these metrics are impacted by the BEDS design and how they can be used to design a resilient system.

buildings↗

MPC4CLR (Model-Predictive-Control-for-Critical-Load-Restoration-in-Power-Distribution-Systems) [SWR-22-24]

Model predictive control (MPC) is a system or process control technique for making decisions under uncertainty via rolling look-ahead optimizations at each control step where only the current step decisions are applied, and the rest are discarded. In this work, we developed an MPC for a critical load restoration (CLR) in power distribution systems to recover system service (electricity delivery) following an extreme event-triggered substation outage. The method considers the problem of controlling distributed energy resources (DERs) of the distribution system with the objective of achieving maximum load pick up while satisfying distribution network flow and voltage constraints. A linearized optimal power flow (OPF) model is employed to represent the physics of the network. The problem formulation is augmented with a ramping (up) reserve product for the DERs to ensure improved and upward monotonic load restoration as time evolves. Simulation analysis and performance tests are performed using a modified IEEE 13-bus test feeder integrated with wind, solar, microturbine, and energy storage battery. The software is developed using various software packages in Julia and Python. The MPC model is implemented using the JuMP optimization language in Julia while the data analytics including renewable generation and load demand forecasts, running the MPC simulation and visualizations is performed in Python.

Eseye, Abinet Tesfaye↗

Switching Device-Cognizant Sequential Distribution System Restoration

This paper presents an optimization framework for sequential reconfiguration using an assortment of switching devices and repair process in distribution system restoration. Compared to existing studies, this paper considers types, capabilities and operational limits of different switching devices, making it applicable in practice. We develop a novel multi-phase method to find the optimal sequential operation of various switching devices and repair faulted areas. We consider circuit breakers, reclosers, sectionalizers, load breaker switches, and fuses. The switching operation problem is decomposed into two mixed-integer linear programming (MILP) subproblems. The first subproblem determines the optimal network topology and estimates the number of steps to reach that topology, while the second subproblem generates a sequence of switching operations to coordinate the switches. For repairing the faults, we design an MILP model that dispatches repair crews to clear faults and replace melted fuses. After clearing a fault, we update the topology of the network by generating a new sequence of switching operations, and the process continues until all faults are cleared. To improve the computational efficiency, a network reduction algorithm is developed to group line sections, such that only switchable sections are present in the reduced network. The proposed method is validated on the IEEE 123-bus and 8500-bus systems.

distribution system↗

A meta-learning based distribution system load forecasting model selection framework

This paper presents a meta-learning based, automatic distribution system load forecasting model selection framework. Furthermore, the framework includes the following processes: feature extraction, candidate model preparation and labeling, offline training, and online model recommendation. Using load forecasting needs and data characteristics as input features, multiple metalearners are used to rank the candidate load forecast models based on their forecasting accuracy. Then, a scoring-voting mechanism is proposed to weights recommendations from each meta-leaner and make the final recommendations. Heterogeneous load forecasting tasks with different temporal and technical requirements at different load aggregation levels are set up to train, validate, and test the performance of the proposed framework. Simulation results demonstrate that the performance of the meta-learning based approach is satisfactory in both seen and unseen forecasting tasks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Network reconfiguration and distributed energy resource scheduling for improved distribution system resilience

Electric utility companies work to restore as much load as possible after power outages caused by extreme weather events. In this paper, an outage management strategy is proposed to enhance distribution system resilience through network reconfiguration and distributed energy resources (DERs) scheduling. After a line fault, the proposed algorithm can identify radial network topology based on the rank of the incidence matrix. The reconfiguration is implemented by switching tie lines and sectionalizing lines. With the new network topology, an optimal DER scheduling problem is solved to minimize the accumulative cost for dispatchable DER operation and load reduction. Finally, the optimal topology that minimizes the accumulative cost is selected from all radial topologies. The computational workload is relatively low because only linear programming needs to be solved. Using the case studies of the IEEE 69-bus and IEEE 123-bus systems, we consider the worst-case scenarios in which faults occur in the upstream feeder. The simulation results demonstrate that the proposed strategy allows for a relatively high percentage of the load to remain in service after line faults. Furthermore, compared with microgrid-formation approaches, the proposed strategy has advantages when applied to the distribution systems with several normally-open tie lines and low DER penetration.

42 ENGINEERING↗

Economic Dispatch With Distributed Energy Resources: Co-Optimization of Transmission and Distribution Systems

The increasing penetration of distributed energy resources (DERs) in the distribution networks has turned the conventionally passive load buses into active buses that can provide grid services for the transmission system. To take advantage of the DERs in the distribution networks, this letter formulates a transmission-and-distribution (T&D) systems co-optimization problem that achieves economic dispatch at the transmission level and optimal voltage regulation at the distribution level by leveraging large generators and DERs. A primal-dual gradient algorithm is proposed to solve this optimization problem jointly for T&D systems, and a distributed market-based equivalent of the gradient algorithm is used for practical implementation. Finally, the results are corroborated by numerical examples with the IEEE 39-Bus system connected with 7 different distribution networks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-Source Data Aggregation and Real-Time Anomaly Classification and Localization in Power Distribution Systems

This paper proposes a real-time anomaly location and classification framework for power distribution systems to simultaneously determine the type of anomaly (i.e., short-circuit fault, cyber attack, DER switching) and its location. The proposed framework employs the data aggregation module to collect the measurement data from multiple field devices operating at different sampling rates, such as protection relays and D-PMUs. The output of the data aggregation is then fed into a multi-task learning-based long-based short-term memory (MTL-LSTM) to classify the type of anomaly and the location in two separate tasks. The proposed MTL-LSTM approach can be utilized in real-time operation in order to distinguish between normal and several anomalous operations and locate the anomaly. The proposed framework is tested on a modified IEEE 33-bus test feeder benchmark that integrates solar generation and energy storage. Furthermore, the results show that the proposed framework can locate and classify anomalies for several operation conditions with more than 96% accuracy. Further experiments highlight the impact of aggregating multiple sources of data on the performance of the proposed model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Validation of Synthetic U.S. Electric Power Distribution System Data Sets

There is a strong need for synthetic yet realistic distribution system test data sets that are as diverse, large, and complex to solve as real systems. Such data sets can facilitate the development of advanced algorithms and the assessment of emerging distributed energy resources while avoiding the need to acquire proprietary critical infrastructure or private data. Such synthetic data sets, however, are useful only if they are realistic enough to look and behave similarly to actual systems. This paper presents a comprehensive framework for validating synthetic distribution data sets using a three-pronged statistical, operational, and expert validation approach. Furthermore, it also presents a set of statistical and operational metric targets for achieving realistic data sets based on detailed characterization of more than 10,000 real U.S. utility feeders. The paper demonstrates the use of the proposed validation approach to validate three large-scale synthetic data sets developed by the authors representing Santa Fe, New Mexico; Greensboro, North Carolina; and the San Francisco Bay Area, California.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Structural parameter identification of distributed systems using finite element approximation

A system identification technique is developed for classes of distributed systems using finite element approximations. Vibrating systems represented by partial differential equations have physical parameters associated with mass, stiffness, and damping distributions which need to be known in order to properly control and design mathematical models of the system. In order to identify these parameters a weighted least-squares algorithm and modified Newton-Raphson method is used for the identification process. The theory and technique is demonstrated by estimating the system parameters of a vibrating cantilever beam made up of several different structural properties.

Lee, K. Y.↗

Real-time disaggregation of renewable energy generation on an electricity distribution system

Techniques are described for disaggregation of renewable energy generation on an electricity distribution system. Aggregate power measurements are identified a distribution substation. Active power load of the distribution substation and active power generated by renewable energy sites can be disaggregated from the aggregate power measurements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Detecting Anomalies for Fire Prevention in Distribution Systems: Challenges and Analytical Techniques

Electric utilities in California have historically been linked to up to 10% of wildfires. To mitigate this risk, Southern California Edison has invested significantly in wildfire prevention strategies, including undergrounding cables and enhancing equipment inspections. This article explores a novel approach to fire prevention by detecting anomalies in the distribution system that may indicate potential fire hazards. The focus is on identifying arcing conditions through high-resolution point-on-wave (POW) measurements. Arcing, a precursor to fires, is challenging to detect due to its subtle transients and complex system topology. The article discusses the use of advanced signal processing and machine learning techniques, such as spectral correlation function and discrete wavelet transform, to extract features from POW data and accurately identify arcing events. The study demonstrates a high accuracy rate in detecting arcing, paving the way for improved fire prevention measures in electric distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cybersecurity Baselines for Electric Distribution Systems and DER

The National Association of Regulatory Utility Commissioners (NARUC) has partnered with the Department of Energy (DOE) to develop a set of cybersecurity baselines for electric distribution systems and the distributed energy resources (DERs) that connect to them. Cybersecurity is an integral underpinning of power system resilience, and this initiative builds on work that states have undertaken over the last decade to mitigate cybersecurity risk across their critical infrastructures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Online Model-Free Chance-Constrained Distribution System Voltage Control Using DERs

This paper proposes an online data-driven distributed energy resource management system (DERMS) optimization method using chance-constrained formulation to address distribution system voltage regulation. This is achieved via the local sensitivity factor (LSF)-enabled reformulation of the DER control into a linear programming (LP) problem, which is easy and computationally efficient to solve. The LSF is estimated using online measurements and does not need the assumption of node load information. The latter is usually required for existing optimization-based methods but is difficult to obtain in practice. To mitigate measurement uncertainties, a scenario-based chance-constrained formulation is constructed. Compared with other control methods, the results carried out in a realistic distribution system show that the proposed method can effectively eliminate voltage violation issues.

chance-constrained optimization↗

Pressure safety approach for PIP-II cryogenic distribution system and cryomodules

The Proton Improvement Plan-II (PIP-II) is a superconducting linear accelerator being built at Fermilab that will provide 800 MeV proton beam for neutrino production. The linac consists of a total of twenty-three (23) cryomodules of five (5) different types. Cooling is required at 2K, 5K and 40K. The Cryogenic Distribution System (CDS) consists of a Distribution Valve Box, ~285 m of cryogenic transfer line, modular Bayonet Cans to interface with cryomodules, and a Turnaround Can. The cryogenic system must provide protection from over-pressure by sizing pressure relief devices for all volumes and process line circuits. The cryomodule cavity circuits have dual pressure ratings, 4.1 bara when cold and 2.05 bara when warm (T>80K). Worst case relieving cases will be identified. The methods for determining heat flux will be presented. For the relieving occurring in the linac tunnel, flow must vent to outside to avoid an oxygen deficiency hazard. Also, we will present vacuum vessel relief sizing to protect the cryogenic distribution system vacuum shells from over pressure during an internal line rupture. The project is funded by US DOE Offices of Science, High Energy Physics.

43 PARTICLE ACCELERATORS↗

Pressure safety approach for PIP-II cryogenic distribution system and cryomodules

The Proton Improvement Plan-II (PIP-II) is a superconducting linear accelerator being built at Fermilab that will provide 800 MeV proton beam for neutrino production. The linac consists of a total of twenty-three (23) cryomodules of five (5) different types. Cooling is required at 2K, 5K and 40K. The Cryogenic Distribution System (CDS) consists of a Distribution Valve Box, ~285 m of cryogenic transfer line, modular Bayonet Cans to interface with cryomodules, and a Turnaround Can. The cryogenic system must provide protection from over-pressure by sizing pressure relief devices for all volumes and process line circuits. The cryomodule cavity circuits have dual pressure ratings, 4.1 bara when cold and 2.05 bara when warm (T>80K). Worst case relieving cases will be identified. The methods for determining heat flux will be presented. For the relieving occurring in the linac tunnel, flow must vent to outside to avoid an oxygen deficiency hazard. Also, we will present vacuum vesse l relief sizing to protect the cryogenic distribution system vacuum shells from over pressure during an internal line rupture. The project is funded by US DOE Offices of Science, High Energy Physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantum Reinforcement Learning for Volt-VAR Control in Power Distribution Systems

Volt-VAR control (VVC) is crucial in active distribution networks for optimizing voltage profiles and minimizing network losses. While traditional deep reinforcement learning (DRL) algorithms exhibit promise for VVC, they often require extensive computational resources to handle such a high-dimensional problem. As a potential solution, quantum reinforcement learning (QRL) algorithms integrate the computational capabilities of quantum computing into the DRL framework. However, existing QRL algorithms struggle with complex VVC problems due to the limitations of current quantum hardware. To bridge this gap, this paper proposes an innovative QRL algorithm featuring an end-to-end architecture that integrates a classical autoencoder, variational quantum circuits (VQCs), and classical post-processing layers. This design efficiently compresses high-dimensional grid states, enabling VQCs to leverage quantum advantages while producing multiple control device outputs tailored for VVC tasks. Numerical studies on three representative distribution systems verify the effectiveness and scalability of the proposed QRL algorithm, and demonstrate its enhanced performance over classical approaches with only approximately 1% of the parameters. Additionally, the robustness of our developed algorithm is validated through noisy quantum environments.

97 MATHEMATICS AND COMPUTING↗