Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Direct detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Transmon Qubit constraints on dark matter-nucleon scattering

We recently pointed out that power measurements of single quasiparticle devices can be used to detect dark matter. These devices have the lowest known energy thresholds, far surpassing standard direct detection experiments, requiring energy deposition above only about an meV. We calculate dark matter induced quasiparticle densities in transmon qubits, and use the latest transmon qubit measurements that provide one of the strongest existing lab-based bounds on dark matter-nucleon scattering below about 100 MeV. We strongly constrain sub-component dark matter, using both a dark matter population thermalized in the Earth as well as the dark matter wind from the Galactic halo. We demonstrate future potential sensitivities using devices with low quasiparticle densities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Developing A Miniaturized Biology Assay for the Astrobiology Search Kit

Partnering with Retego Labs we will develop an acetate assay to use in the Astrobiology Search Kit advanced spectrometer. Our current knowledge of metabolic pathways (methanogeneis, and acetogenesis) both produce acetate. There is no known method of producing acetate abiotically, therefore the detection of acetate indicates the presence of biology. There is no current assays to directly detect acetate. We would be developing the first assay. Our development plan is based on the development of previous assays. We start with EPA standards then modify and increase the sensitivity based on our detection needs. In this case the detection is 10^2 cells/ml equivalent. This assay would be useful on Titan where if life exists the biogeochemistry is methane based instead of water based like Earth (possibly Mars, Europa).

H. Smith↗

Multimodal imaging of oil-in-water bilgewater emulsion and biofilms

Bilgewater emulsions, consisting of oil and surfactant mixtures in water, affect many aquatic species. Thus development of methods and techniques to treat or mitigate the formation and undesired consequences of shipboard emulsions are urgently needed. This work presents new results of the evolution of the bilgewaer chemical and physical properties using in situ imaging. A Navy O/W emulsion consisting of three oils and a detergent mixture was used as the synthetic bilgewater model [1, 2]. Synthetic oil-in-water (O/W) emulsion droplets were seled in a vacuum compatible microfluidic sample holder and imaged using a suite of tools including scanning electron microscopy (SEM), time-of-flight secondary ion mass spectrometry (ToF-SIMS), confocal laser scanning microscopy, and optical microscopy, highlighting the advantage of multiscale analysis and its applications in waste reduction and treatment in the environment. The transferrable and vacuum compatible microfluidic interface, System for Analysis at the Liquid Vacuum Interface (SALVI), was used in this study. SALVI enabled surface analysis of liquids and liquid-solid interactions using ToF-SIMS and SEM [3, 4]. Its detection window is an aperture of 2 ?m in diameter open to vacuum, permitting direct detection of the liquid surface. Liquid is withheld by surface tension within the aperture. The interface is composed of a silicon nitride membrane and polydimethylsiloxane microchannel [3, 4]. A variety of samples including complex liquid mixtures, ionic liquids, single mammalian cells, live biofilms, and solid-electrolyte interface have been analyzed using in situ imaging [5, 6]. The feasibility of using SALVI for in situ SEM imaging of nanoparticles and colloids in liquid was recently demonstrated [7]. This paper shows new findings of multimodal imaging and analysis of synthesized emulsion particles in water. Figure 1 depicts a schematic of multimodal in situ imaging of bilgewater emulsion using SEM and ToF-SIMS. Furthermore, we study the interactions of microbes and bilgewater emulsion. Microbes play an important role in the ocean. We hypothesize that microbes release organics that can act as surfactants that affect bilgewater formation or weakening. We present the first systematic study of emulsions and biofilms and investigate the effects of biofilms on bilgewater emulsions. Pseudomonas was selected as a model strain. Biofilms were cultured in a microchannel to allow culture [8]. Once a thick layer of biofilms was formed, the medium solution was changed to a mixture consisting of 50 % bilgewater emulsion. Dispersed biofilms were collected at 24 hrs. and 48 hrs. after emulsions were introduced into the channel. Bilgewater emulsions, biofilms, and mixtures of bilgewater emulsions and biofilms were analyzed using multiple in situ and ex situ techniques as described earlier. Our findings indicate that biofilms change the chemical makeup of the emulsion surface compositions and emulsion droplet size distribution, confirming the hypothesis that extracellular polymeric substance (EPS) related components released from biofilms can function as surfactants and change the oil-in-water interfaces.

bilgewater, multimodal imaging, biofilms↗

Systems level feasibility study for the detection of extra-solar planets. Volume 1: Infrared interferometer (IRIS) known as the Stanford Concept

A sensor system for the direct detection of extrasolar planets from an Earth orbit is evaluated: a spinning, infrared interferometer (IRIS). It is shuttle deployed, free flying, requires no on-orbit assembly and no reservicing over a design life of five years. The sensor concept and the mission objectives are reviewed, and the performance characteristics of a baseline sensor for standard observation conditions are derived. A baseline sensor design is given and the enabling technology discussed. Cost and weight estimates are performed; and a schedule for an IRIS program including technology development and assessment of risk are given. Finally, the sensor is compared with the apodized visual telescope sensor (APOTS) proposed for the same mission. The major conclusions are: that with moderate to strong technology advances, particularly in the fields of long life cryogenics, dynamical control, mirror manufacturing, and optical alignment, the detection of a Jupiter like planet around a Sunlike star at a distance of 30 light years is feasible, with a 3 meter aperture and an observation time of 1 hour. By contrast, major and possibly unlikely breakthroughs in mirror technology are required for APOTS to match this performance.

Source record↗

The Visible Nulling Coronagraph--Architecture Definition and Technology Development

This paper describes the advantages of visible direct detection and spectroscopy of Earth-like extrasolar planets using a nulling coronagraph instrument behind a moderately sized single aperture space telescope. Our concept synthesizes a nulling interferometer by shearing the telescope pupil, with the resultant producing a deep null. We describe nulling configurations that also include methods to mitigate stellar leakage, such as spatial filtering by a coherent array of single mode fibers, and post-starlight suppression wavefront sensing and control. With diffraction limited telescope optics and similar quality components in the optical train (lambda/20), suppression of the starlight to 1e-10 is readily achievable. We describe key features of the architecture and analysis, present latest results of laboratory measurements demonstrating achievable null depth and component development, and discuss future key technical milestones.

nulling interferometer↗

Thiol redox proteomics: Characterization of thiol-based post-translational modifications

Redox post-translational modifications on cysteine thiols (redox PTMs) have profound effects on protein structure and function, thus enabling regulation of various biological processes. Redox proteomics approaches aim to characterize the landscape of redox PTMs at the systems level. These approaches facilitate studies of condition-specific, dynamic processes implicating redox PTMs and have furthered our understanding of redox signaling and regulation. Mass spectrometry (MS) is a powerful tool for such analyses which has been demonstrated by significant advances in redox proteomics during the last decade. A group of well-established approaches involves the initial blocking of free thiols followed by selective reduction of oxidized PTMs and subsequent enrichment for downstream detection. Alternatively, novel chemoselective probe-based approaches have been developed for various redox PTMs. Direct detection of redox PTMs without any enrichment has also been demonstrated given the sensitivity of contemporary MS instruments. This review discusses the general principles behind different analytical strategies and covers recent advances in redox proteomics. Several applications of redox proteomics are also highlighted to illustrate how large-scale redox proteomics data can lead to novel biological insights.

59 BASIC BIOLOGICAL SCIENCES↗

Hydrogen Analysis by Gas Chromatography–Mass Spectrometry

The detection of hydrogen in complex gas mixtures is essential for many applications. Conventional approaches such as gas chromatography (GC) with thermal conductivity detection (TCD) and residual gas analyzers (RGAs) face significant limitations: TCD exhibits poor response when helium is used as a carrier gas, whereas RGAs lack chromatographic separation, preventing reliable quantification of hydrogen because of interference from other species. Traditional GC methods rely on dual-column configurations with packed or molecular-sieve porous layer open tubular (PLOT) columns to separate hydrogen from O2, N2, CO, CO2, CH4, and other hydrocarbons, increasing system complexity and limiting compatibility with mass spectrometry (MS) detection. In this work, we developed and validated a robust GC–MS method capable of directly detecting and quantifying hydrogen using electron ionization (EI) without dopants, reagent gases, or ion–molecule reaction schemes. By integrating a modified EI source and a cryogenically cooled single capillary column configuration, we achieved baseline separation of hydrogen from all major permanent gases and hydrocarbons in a refinery gas mixture using helium as the carrier gas. The method demonstrated excellent linearity, high sensitivity, and exceptional reproducibility. Adjustable sample-loop volumes and split ratios enabled optimization of peak shape and signal-to-noise performance for trace-level and percent-level hydrogen concentrations. Beyond hydrogen quantitation, the method provides simultaneous compositional profiling of other gases in a mixture in a single run, making it valuable for a wide range of tasks.

Lobodin, Vlad [ORNL]↗

Direct Probe of Dark Energy Interactions with a Solar System Laboratory: NASA Innovative Advanced Concepts (NIAC) - Phase 1 Final Report

In this NIAC (NASA Innovative Advanced Concepts) study, we embrace the challenge of direct detection of the galileon dark energy field in the Vainshtein model. We developed a mission concept to directly measure the galileon field using the solar system as a laboratory. The experiment scheme involves precise measurements of the trace of the total scalar force gradient tensor. A tetrahedral constellation off our spacecraft measures the "local" traces while orbiting about 1 AU (Astronomical Unit) away from the Sun and faraway from planets (Figure 1). The trace measurement is insensitive to the much stronger gravity field which satisfies the inverse square law and thus is traceless. Atomic test masses and atom interferometer measurement techniques are used as precise drag-free inertial references while laser ranging interferometers are employed to connect among atom interferometer pairs in spacecraft for the differential gradient force measurements. We conclude that such a mission is scientifically and technologically feasible. We show that a mission of 3-year measurement time would be able to provide high confidence statements (over 3 standard deviations) about the existence and strength of the cubic galileon field of the Sun. In addition, such a mission would also provide rich and diverse scientific data for testing any gravitational theory in general beyond the Newtonian gravity, hunting for ultra-light fields of dark matter, and detecting gravitational waves in the mid-frequency band between those of LIGO (Laser Interferometer Gravitational-Wave Observatory) and LISA (Laser Interferometer Space Antenna). For these reasons, we will term the mission concept Gravity Observation and Dark energy Detection Explorer in the Solar System (GODDESS).

Dark Energy↗

Machine Learning Enabled Sensor Fusion for In-Situ Defect Detection in Laser Powder Bed Fusion

Laser Powder Bed Fusion (L-PBF) Additive Manufacturing (AM) is among the metal 3D printing technologies most broadly adopted by the manufacturing industry. The current industry qualification paradigm for critical-application L-PBF parts relies heavily on expensive non-destructive inspection techniques such as X-Ray Computed Tomography (XCT), which significantly limits the use-cases of L-PBF. In situ monitoring of the process promises a less expensive alternative to ex situ testing, but existing sensor technologies and data analysis techniques struggle to detect sub-surface flaws (e.g., porosity and cracking) on production-scale L-PBF printers. RTX Technologies Research Center (RTRC) has licensed ORNL’s Peregrine software package – a printer- and camera-agnostic data analytics tool designed specifically for detecting process anomalies using in situ data collected during powder bed printing. The goal of this project was to feed temporally rich, multi-modal sensor data, including visible light, integrated near infrared (NIR), and spatially mapped co-axial melt pool thermal emission data into Peregrine to enable detection of subsurface flaws. XCT data was used as ground truth training data to allow Peregrine’s deep learning algorithms to recognize anomalies in these complex data streams in both test artifacts and industrially relevant geometries. Completion of this program has seen the successful implementation of multi-modal, multi-layer sensor data footprints for training of machine learning models in Peregrine. Flaws detected in XCT data have been successfully detected directly from this in situ data footprint, and initial analyses of the in situ probability-of-detection has been conducted, showing performance levels commensurate with traditional non-destructive evaluation (NDE) methods. The in situ monitoring methodology was then applied to an industrially relevant component that was using post-build NDE, highlighting the utility of the proposed method for hard-to-inspect AM components. As a direct result of this program, two journal manuscripts [1], [2] have been published in Additive Manufacturing, with additional manuscripts planned following program completion.

36 MATERIALS SCIENCE↗

Wave Detection and Tracking Within a Rotating Detonation Engine Through Object Detection

As the operational time window of experimental rotating detonation engines (RDEs) is expanded and the technology matures toward integration within gas turbines, monitoring techniques must evolve to offer computationally efficient and highly time-resolved diagnostics. In this study, computer vision object detection methodology that seeks to reduce data processing time and calculate wave velocity within drastically reduced time intervals as compared to traditional high-frame-rate RDE images analysis techniques is proposed. The adapted you-only-look-once object detection network is trained to detect individual detonation waves within single down-axis RDE images. The wave location and rotational direction detected within a frame are tracked through a series of high-speed images to calculate the frame-to-frame wave velocity with the time-step resolution of $\mathrm{20 μs}$ across a series of frames. The analysis of the annotation box size and image linearization effects is presented, demonstrating the lowest frame-to-frame velocity total uncertainty of $\mathrm{±3.8\%}$ and the highest classification speed of 9.5 frames per second using linearized images. Linearized images “unwrap” the RDE annulus pixel region to a reduced image size. Here, this new method offers great reductions in data processing times and unsteady detonation behavior insight at intervals more comparable to the timescales of detonation wave interactions via the application of machine learning to experimental RDE data.

33 ADVANCED PROPULSION SYSTEMS↗

Lidar Measurements of Wind, and Cloud & Aerosol Structures using HARLIE at the WVIOP, Sept/Oct 2000

The holographic scanning lidar HARLIE made continuous measurements of aerosol and cloud one-micron backscatter and derived the horizontal wind speed and direction at cloud height over the ARM (SGP) site during the water vapor campaign WVIOP, September 17 - October 6, 2000. Whenever possible, these measurements were compared with Loran-C winds as measured by the routine launches of Vaisala radiosonde balloons scheduled by the ARM project. Taken overall, the agreement between these two types of observation is excellent, which could be taken merely as a validation of the relatively new HARLIE technique. However, the detailed comparison for a given sonde launch clearly requires that, out of the HARLIE data which are taken all the time at all altitudes, one must select those segments that match the altitude-time trajectory of the sonde. Moreover, the conical HARLIE scan at a 45 deg. elevation angle covers a wide area that is more representative of the average wind conditions above the site than the isolated track of the sonde's ascent. We suggest that the HARLIE instrument offers a more general and improved representation of the horizontal wind profile whenever there is sufficient backscatter by clouds and aerosols for lidar operation. HARLIE is a rugged and compact lidar that operates from aircraft as well as from the ground and has been used in several meteorological campaigns. As a "direct detection" lidar, HARLIE does not require the complexity of a coherent detection system. The data reduction algorithms facilitate the rapid and accurate determination of wind speed and direction at all altitudes. Wind measurements and HARLIE performance data from WVIOP 2000 and other campaigns will be presented.

Schwemmer, Geary↗

A Search for Coronal Emission at the Bottom of the Main-Sequence: Stars and Brown Dwarf Candidates with Spectral Types Later than M7 and the Rotation-Activity Relation

This program intended to test whether the lowest mass stars at the bottom end of the main sequence and the lower mass brown dwarfs have coronae. If they have coronae, what are the coronal characteristics and what drives them? In the classical dynamo picture, the closed magnetic loop structure is generated near the boundary of the convective envelope and the radiative core. Stars with mass below 0.30 Msun however are fully convective, and the nature of the dynamo responsible for the generation of the coronae in this regime is poorly understood. Previous results from the ROSAT mission (e.g., Fleming et al. 1993, 1995; Schmitt et al. 1995) had confirmed three very important characteristics of M-star coronae: (1) a very high percentage of all M dwarfs have coronae (of order 85% in the local 7 pc sample), (2) those M dwarfs showing high chromospheric activity, such as having the Balmer series in emission or large/numerous optical flaring, indeed exhibit the highest coronal activity, and (3) that the maximum saturation boundary in X-ray luminosity, which amounts to 0.0001-0.001 for Lx/Lbol for the dMe stars, extends down to the current detection limit, through spectral types M7. It was likely that the incompleteness noted for result (1) above was simply a detection limit problem; for more distant sources, the X-ray fainter dM stars will drop below detection thresholds before the more X-ray luminous dMe stars. The latest stars for which direct detection of the corona had been successful were of spectral type dM7 (e.g., VB8, LHS 3003). This program proposed to obtain ROSAT HRI observations for a large number of the coolest known (at that time) stars at the bottom of the main-sequence, which had spectral types of M9 or later. Three stars were approved for observations with ROSAT-HRI totaling 180 ksec. The goal was to obtain X-ray detections or low upper limits for the three approved stars.

Stringfellow, Guy↗

Porosity Detection and Localization During Composite Cure Inside an Autoclave Using Ultrasonic Inspection

Composite materials offer unique benefits in aerospace applications such as increased strength-to-weight ratio and improved fatigue properties. They are increasingly being used in major commercial aircraft programs. However, current processing methods can lead to defects in composite parts, which must be detected using post-manufacturing inspection methods. Porosity (i.e., pores, voids) is a critical defect from the cure process that is detrimental to performance of the composite part. It is therefore necessary to understand and eliminate the formation of porosity defects. At NASA Langley Research Center, an in-situ cure monitoring system was developed to detect porosity defects as they form in real-time inside an autoclave. A capability to directly detect and localize porosity within a composite during cure did not exist before. This study is focused on an elevated-temperature ultrasonic inspection system to detect porosity defects in composites during autoclave cure. The ultrasonic inspection system operated inside an autoclave within an enclosure cooled by intermittent liquid nitrogen (LN_2) injections. A high-temperature, 2.25 MHz, transducer transmitted ultrasonic waves through the tool plate and into the composite part and measured the amplitude and time of flight of the reflected waves with a 1 mm × 1 mm step size/areal resolution. Porosity was observed via the ultrasonic reflections, which experienced increased attenuation in regions of high porosity. Distinct regions of increased porosity were present due to uneven pressure across the panel, which was driven by an intentional misfit between the flat caul plate and the tapered composite panel with ply drops. The results were validated by post-cure ultrasonic inspection and micrographs. The in-situ inspection system was able to successfully provide porosity detection and localization in the tapered ply-drop panel. The successful results indicate the promise of this system for future implementation in the manufacturing of composite structures for aerospace applications.

Composites↗

Planet detection and spectroscopy in visible light with a single aperture telescope and a nulling coronagraph

This talk describes a new concept for visible direct detection of Earth like extra solar planets using a nulling coronagraph instrument behind a 4m telescope in space. In the baseline design, a 4 beam nulling interferometer is synthesized from the telescope pupil, producing a very deep theta^4null which is then filtered by a coherent array of single mode fibers to suppress the residual scattered light. With perfect optics, the stellar leakage is less than 1e-11 of the starlight at the location of the planet. With diffraction limited telescope optics (lambda/20), suppression of the starlight to ~1e-10 is possible. The concept is described along with the key advantages over more traditional approaches such as apodized aperture telescopes and Lyot type coronagraphs.

coronagraph↗

A Review of Twenty-Six Years of U.S. Weather Radar Detection of Meteorite Falls

Weather radars have proven to be a valuable tool for detection, rapid recovery, and analysis of meteorite falls and fall statistics. The U.S. operates a nationwide weather radar network (NEXRAD) which will be discussed here, but it is important to acknowledge that weather radars operate worldwide and efforts are underway to utilize this rich resource. By the author’s count, since the NEXRAD system came online in the late 1990s it has detected 34 recovered meteorite falls and another 33 unrecovered probable falls. Weather radars are powerful tools because they directly detect meteorites falling after the end of their luminous flight, during the "dark flight" period. This allows rapid recovery through detection and modeling of fall locations down to as little as tens of meters. They are also the only tool that analyzes meteorites that survive their parent fireball, before many or all of them are lost to terrain. This allows direct measurement of meteorite mass, particle size distribution, and with additional work should allow calculation of pre-atmospheric mass and a measure of whole-body strength.

M D Fries↗

Dark matter absorption via electronic excitations

We revisit the calculation of bosonic dark matter absorption via electronic excitations. Working in an effective field theory framework and consistently taking into account in-medium effects, we clarify the relation between dark matter and photon absorption. As is well-known, for vector (dark photon) and pseudoscalar (axion-like particle) dark matter, the absorption rates can be simply related to the target material’s optical properties. However, this is not the case for scalar dark matter, where the dominant contribution comes from a different operator than the one contributing to photon absorption, which is formally next-to-leading-order and does not suffer from in-medium screening. It is therefore imperative to have reliable first-principles numerical calculations and/or semi-analytic modeling in order to predict the detection rate. We present updated sensitivity projections for semiconductor crystal and superconductor targets for ongoing and proposed direct detection experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Monte Carlo calibration of the SMM gamma ray spectrometer for high energy gamma rays and neutrons

The Gamma Ray Spectrometer (GRS) on the Solar Maximum Mission spacecraft was primarily designed and calibrated for nuclear gamma ray line measurements, but also has a high energy mode which allows the detection of gamma rays at energies above 10 MeV and solar neutrons above 20 MeV. The GRS response has been extrapolated until now for high energy gamma rays from an early design study employing Monte Carlo calculations. The response to 50 to 600 MeV solar neutrons was estimated from a simple model which did not consider secondary charged particles escaping into the veto shields. In view of numerous detections by the GRS of solar flares emitting high energy gamma rays, including at least two emitting directly detectable neutrons, the calibration of the high energy mode in the flight model has been recalculated by the use of more sophisticated Monte Carlo computer codes. New results presented show that the GRS response to gamma rays above 20 MeV and to neutrons above 100 MeV is significantly lower than the earlier estimates.

Cooper, J. F.↗

Electro-Optic Lightning Detector

Electric field measurements are fundamental to the study of thunderstorm electrification, thundercloud charge structure, and the determination of the locations and magnitudes of charges deposited by lightning. Continuous field observations can also be used to warn of impending electrical hazards. For example, the USAF Eastern Range (ER) and NASA Kennedy Space Center (KSC) in Florida currently operate a ground-based network of electric field mill sensors to warn against lightning hazards to space vehicle operations/launches. The sensors provide continuous recordings of the ambient field. Others investigators have employed flat-plate electric field antennas to detect changes In the ambient field due to lightning. In each approach, electronic circuitry is used to directly detect and amplify the effects of the ambient field on an exposed metal conductor (antenna plate); in the case of continuous field recordings, the antenna plate is alternately shielded and unshielded by a grounded conductor. In this work effort, an alternate optical method for detecting lightning-caused electric field changes is Introduced. The primary component in the detector is an anisotropic electro-optic crystal of potassium di-hydrogen phosphate (chemically written as KH2PO4 (KDP)). When a voltage Is placed across the electro-optic crystal, the refractive Indices of the crystal change. This change alters the polarization state of a laser light beam that is passed down the crystal optic axis. With suitable application of vertical and horizontal polarizers, a light transmission measurement is related to the applied crystal voltage (which in turn Is related to the lightning caused electric field change). During the past two years, all critical optical components were procured, assembled, and aligned. An optical housing, calibration set-up, and data acquisition system was integrated for breadboard testing. The sensor was deployed at NASA Marshall Space Flight Center (MSFC) in the summer of 1998 to collect storm data. Because solid-state technology is used, future designs of the sensor will be significantly scaled down In physical dimension and weight compared to the present optical breadboard prototype. The use of fiber optics would also provide significant practical improvements.

Koshak, William J.↗