Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Examination of synthetic gas puff imaging diagnostic data from a gyrokinetic turbulence code

A synthetic gas puff imaging (GPI) diagnostic has been developed for the purpose of validating the three-dimensional gyrokinetic turbulence code XGC. The synthetic diagnostic is described and applied to XGC simulations of two Alcator C-Mod discharges. The turbulence characteristics deduced from the resulting simulated GPI frames, using analysis techniques similar to those applied to experimental data, are compared with locally derived characteristics extracted directly from the XGC output. The comparison of the two is shown to be potentially impacted by misalignment between the GPI view and the magnetic field, the dependence of the light emission on the electron density and temperature, and spatial and temporal variations in the neutral gas cloud induced by the turbulent plasma fluctuations. We conclude that quantitative and, in some cases even qualitative, validation of turbulence simulations need to account for these effects. While we cannot directly compare our results with experimental data due to the absence of high quality GPI data from the shots and times simulated by XGC, we do relate the overall characteristics obtained from the synthetic GPI analysis to published Alcator C-Mod GPI data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of microwave broadband CMOS transmitter and receiver circuits for MIR and ECEI plasma diagnostics

To efficiently determine the plasma electron density fluctuations using the MIR diagnostic technique, a 55–75 GHz 65 nm-CMOS transmitter has been developed where four separate intermediate frequency (IF) signals are up-converted, amplified, and then combined to generate an 8-tone RF output; a broadband 90 nm-CMOS receiver has also been constructed, which consists of an RF-low noise amplifier (LNA), mixer, and IF amplifier. The circuits and their corresponding modules will soon be deployed on the DIII-D and NSTX-U fusion devices. A 110–140 GHz 65 nm-CMOS receiver has also been designed, which is suitable for measuring the deep-core temperature fluctuations in the DIII-D tokamak using the electron cyclotron emission imaging diagnostic system. In addition to the RF-LNA/balun, mixer, and IF amplifier, an LO balun/tripler and driving amplifier are now included in this highly integrated circuit chip. By adopting the microwave and millimeterwave system-on-chip concept in the front-end system design, this paper demonstrates that compact transmitter and receiver modules can be easily built, which, in turn, facilitates array implementation and maintenance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Upgrades to the ion cyclotron emission diagnostic on the DIII-D tokamak

The ion cyclotron emission diagnostic on the DIII-D tokamak comprises seven single-turn loops that measure high-frequency (1–100 MHz) magnetic field fluctuations that are often excited by energetic particles in the plasma. The raw voltage signals induced in the loops in response to these fluctuations travel through a series of cables, isolation transformer DC blocks, low-pass filters, and finally a digitizer before being analyzed in frequency space. The diagnostic has been recently upgraded, most notably to include four additional graphite tile loops and a new eight-channel digitizer. The previous three loops are all on the low-field side of the tokamak. The measurement capabilities of the system have been expanded by the addition of a new horizontally oriented loop on the low-field side, an additional toroidal loop on the low-field side, and two toroidal loops on the high-field side. These loops will be used to provide approximate mode polarization, improved toroidal mode number calculations, and information on modes in inward-shifted plasmas, respectively.

47 OTHER INSTRUMENTATION↗

Calibration of a versatile multi-energy soft x-ray diagnostic for WEST long pulse plasmas

A compact multi-energy soft x-ray diagnostic is being installed on the W Environment in Steady-state Tokamak (WEST), which was designed and built to test ITER-like tungsten plasma facing components in a long pulse (~1000 s) scenario. The diagnostic consists of a pinhole camera fielded with the PILATUS3 photon-counting Si-based detector (≲100 kpixel). The detector has sensitivity in the range 1.6–30 keV and enables energy discrimination, providing a higher energy resolution than conventional systems with metal foils and diodes with adequate space and time resolution (≲1 cm and 2 ms). The lower-absorption cut-off energy is set independently on each one of the ~100 kpixels, providing a unique opportunity to measure simultaneously the plasma emissivity in multiple energy ranges and deduce a variety of plasma parameters (e.g., T e , n Z , and ΔZ eff ). The energy dependence of each pixel is calibrated here over the range 3–22 keV. The detector is exposed to a variety of monochromatic sources—fluorescence emission from metallic targets—and for each pixel, the lower energy threshold is scanned to calibrate the energy dependence. The data are fit to a responsivity curve (“S-curve”) that determines the mapping between the possible detector settings and the energy response for each pixel. Here, the calibration is performed for three energy ranges: low (2.3–6 keV), medium (4.5–13.5 keV), and high (5.4–21 keV). We determine the achievable energy resolutions for the low, medium, and high energy ranges as 330 eV, 640 eV, and 950 eV, respectively. The main limitation for the energy resolution is found to be the finite width of the S-curve.

47 OTHER INSTRUMENTATION↗

Optimization of the gamma reaction history diagnostic for double-shell pusher areal density and reaction history measurements on the National Ignition Facility

The double-shell inertial confinement fusion campaign, which consists of an aluminum ablator, a foam cushion, a high-Z pusher (tungsten or molybdenum), and liquid deuterium–tritium (DT) fuel, aims for its first DT filled implosions on the National Ignition Facility (NIF) in 2024. The high-Z, high density pusher does not allow x-rays to escape the double-shell capsule. Therefore, nuclear diagnostics such as the Gamma Reaction History (GRH) diagnostic on the NIF are crucial for understanding high-Z implosion performance. To optimize the GRH measurement of fusion reaction history and the pusher’s areal density, the MCNP6.3-based forward model of the detector was built. When calculating the neutron-induced inelastic gamma ray production, the interaction of neutrons with the compressed fuel was additionally included. By folding the calculated gamma ray spectrum output and the previously calibrated GRH detector responses, the optimum set of GRH energy thresholds for measuring the pusher areal density is determined to be 2.9 and 6.3 MeV for DT double-shell experiments. In addition, the effect of the down-scattering of neutrons on the gamma ray spectrum, the minimum required yield for measurements, and the attenuation of the gamma rays through the pusher are analyzed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress toward absolute calibrations of DC x-ray sources from 1 keV to >30 keV for Z diagnostics applications

Numerous x-ray diagnostics at the Z facility, time-resolved and time-integrated, would benefit from a local calibrated x-ray source. For many years, Z has used low-power Manson x-ray sources to provide some characterization information for components of Z diagnostics below 30 keV. More recently, we have acquired TruFocus x-ray sources, which operate at voltages up to 100 kV depending on the anode material and model. These DC sources have demonstrated good stability and repeatability. Absolute calibrations of either sources or detectors usually involve another calibrated detector from another source, which has not been readily available locally. Therefore, we have adopted the strategy of characterizing a sensitive semiconductor diode detector by controlling or inferring the active volume. This characterized detector is then used to scale the Manson x-ray spectral shape as measured by an Amptek energy-resolving detector. Here, the result agrees well with the modeled source spectrum. We can apply this technique to the TruFocus as well.

Crystal spectroscopy↗

A new synthetic correlation electron cyclotron emission diagnostic for validating nonlinear gyrokinetic simulations of electron temperature turbulence

To validate nonlinear gyrokinetic simulations of electron temperature turbulence, the experimental correlation electron cyclotron emission (CECE) measurements are to be compared using a synthetic CECE diagnostic, which generates modeled CECE measurement quantities by implementing realistic measurement parameters (e.g., spatial and wavenumber resolutions, radial location, etc.) to nonlinear gyrokinetic simulations. In this work, we calculate the radial and vertical spatial and wavenumber transfer functions, which are defined by the electron cyclotron emission emissivity radial profile and vertical probing antenna pattern, respectively. These transfer functions are applied to nonlinear gyrokinetic simulations of electron temperature turbulence using the continuum gyrokinetic code. A simultaneous comparison of the experimental electron temperature turbulence power spectrum and root-mean-square (RMS) level, as well as the radial correlation length with the new synthetic CECE diagnostic at a core location ρ ∼ 0.75 in an L-mode DIII-D tokamak plasma, is presented. Here, the preliminary result shows that the synthetic CECE output underestimates the RMS level by ∼42% and overestimates the radial correlation length by ∼40%.

Cyclotron radiation↗

LAMP Diagnostics at the Point-of-Care: Emerging Trends and Perspectives for the Developer Community

Over the past decade, loop-mediated isothermal amplification (LAMP) technology has played an important role in molecular diagnostics. Amongst numerous nucleic acid amplification assays, LAMP stands out in terms of sample-to-answer time, sensitivity, specificity, cost, robustness, and accessibility, making it ideal for field-deployable diagnostics in resource-limited regions. In this review, we outline the front-end LAMP design practices for point-of-care (POC) applications, including sample handling and various signal readout methodologies. Next, we explore existing LAMP technologies that have been validated with clinical samples in the field. We summarize recent work that utilizes reverse transcription (RT) LAMP to rapidly detect SARS-CoV-2 as an alternative to standard PCR protocols. Finally, we describe challenges in translating LAMP from the benchtop to the field and opportunities for future LAMP assay development and performance reporting. Despite the popularity of LAMP in the academic research community and a recent surge in interest in LAMP due to the COVID-19 pandemic, there are numerous areas for improvement in the fundamental understanding of LAMP, which are needed to elevate the field of LAMP assay development and characterization.

60 APPLIED LIFE SCIENCES↗

Observations of xenon spectra on the EAST x-ray crystal spectrometer for high-temperature plasma diagnostics

The Xe 44+ 2.7203 Å line, which has been proposed as one of the diagnostic lines for the x-ray imaging crystal spectrometer on ITER, is observed on the EAST tokamak together with its several satellite lines. The observations are made under high electron temperature (T e ) conditions (core T e > 5 keV). Most of the observed xenon lines are identified by comparing the experiment results with the atomic simulation results. The first ion temperature measurements made by the xenon spectra on EAST are also reported in this article. These xenon spectra observations contribute to the justification for using xenon as the diagnostic impurity in x-ray crystal spectrometers in future reactor-scale high-temperature plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Blade Designs For Improved Multi-Phase Performance In sCO 2 Compressors; Part II - Optical Diagnostics In sCO 2 And Experimental Evaluation With Particle Image Velocimetry

This paper presents the second part of a study in which the leading-edge and suction surface of a compressor blade was modified to delay onset of phase change for sCO 2 compressors operating near the critical point. Using a first-of-its-kind apparatus for the measurement of sCO 2 flow fields, Particle Image Velocimetry (PIV) is used for local flow field measurements of two compressor blade geometries: the modified “biased-wedge,” and a conventional constant thickness blade. Utilizing the developed hardware, the feasibility of a simple, laser-based diagnostic for qualitatively measuring liquid phase regions, is also presented. The design of the optical diagnostics rig, a discussion of numerous challenges, and necessary considerations involved in performing optical-based measurements like PIV, in sCO 2 , are discussed. Velocity field measurements for the modified compressor profile show a much lower suction peak compared to a conventional blade. Furthermore, these results validate numerical results at the tested conditions, where the suction side profile of the biased wedge works to minimize the local pressure gradient.

14 SOLAR ENERGY↗

Development of HEK-293 Cell Lines Constitutively Expressing Flaviviral Antigens for Use in Diagnostics

Flaviviruses are important human pathogens worldwide. Diagnostic testing for these viruses is difficult because many of the pathogens require specialized biocontainment. To address this issue, we generated 39 virus-like particle (VLP)- and nonstructural protein 1 (NS1)-secreting stable cell lines in HEK-293 cells of 13 different flaviviruses, including dengue, yellow fever, Japanese encephalitis, West Nile, St. Louis encephalitis, Zika, Rocio, Ilheus, Usutu, and Powassan viruses. Antigen secretion was stable for at least 10 cell passages, as measured by enzyme-linked immunosorbent assays and immunofluorescence assays. Thirty-five cell lines (90%) had stable antigen expression over 10 passages, with three of these cell lines (7%) increasing in antigen expression and one cell line (3%) decreasing in antigen expression. Antigen secretion in the HEK-293 cell lines was higher than in previously developed COS-1 cell line counterparts. These antigens can replace current antigens derived from live or inactivated virus for safer use in diagnostic testing.

59 BASIC BIOLOGICAL SCIENCES↗

Analysis of Fault Data Collected from Automated Fault Detection and Diagnostic Products for Packaged Rooftop Units

Rooftop units (RTUs) and other packaged systems are very common in commercial buildings in the U.S., and they often have minimal controls and poor performance. Automated fault detection and diagnostics (AFDD) is a powerful tool that can continuously monitor operating equipment, detect abnormal performance, diagnose problems, and report findings to building operators. AFDD technologies for RTUs have been under development for many years and have recently begun to enter the market in a significant way. There are several AFDD systems available for RTUs that feature a wide range of designs, capabilities, and reporting. Unfortunately, there is little consistency among the AFDD applications and little understanding of the performance and value of these systems. This study presents analysis of AFDD data provided by four companies from over 28,000 RTUs, five building types, and multiple climate zones. The objectives of this investigation were to gain a better understanding of how RTU AFDD systems operate, the types and frequencies of faults identified, and how building operators interact with these systems. The monitoring of a variety of RTUs provides insights into the AFDD monitoring inputs, faults, and diagnostics from which these tools are capable of informing building owners about the status of their HVAC systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of Fault Data Collected from Automated Fault Detection and Diagnostic Products for Packaged Rooftop Units

Rooftop units (RTUs) and other packaged systems are very common in commercial buildings in the U.S., and they often have minimal controls and poor performance. Automated fault detection and diagnostics (AFDD) is a powerful tool that can continuously monitor operating equipment, detect abnormal performance, diagnose problems, and report findings to building operators. AFDD technologies for RTUs have been under development for many years and have recently begun to enter the market in a significant way. There are several AFDD systems available for RTUs that feature a wide range of designs, capabilities, and reporting. Unfortunately, there is little consistency among the AFDD applications and little understanding of the performance and value of these systems. This study presents analysis of AFDD data provided by four companies from over 28,000 RTUs, five building types, and multiple climate zones. The objectives of this investigation were to gain a better understanding of how RTU AFDD systems operate, the types and frequencies of faults identified, and how building operators interact with these systems. The monitoring of a variety of RTUs provides insights into the AFDD monitoring inputs, faults, and diagnostics from which these tools are capable of informing building owners about the status of their HVAC systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A laser inverse Compton scattering diagnostic to study runaway electron dynamics during tokamak disruptions

The goal is to design a new diagnostic based on laser inverse Compton scattering (LICS) to study the dynamics of runaway electron formation and their subsequent loss during triggered disruptions in DIII-D. It is known that better measurements of the runaway electron population, throughout the evolution of a disruption, is critical for mitigating the impact of energetic electron beams especially in high plasma current discharges such as those in reactor relevant burning plasmas. The goal of the LICS approach being designed for DIII-D is to measure the timeresolved spatial profile and energy distribution of the runaway electrons while they are in the core of the tokamak plasma. During the last year, a code was developed to simulate the signals from a new laser scattering diagnostic for DIII-D, which will measure the relativistic electron population expected in DIII-D after disruptions triggered by argon pellet injection.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Novel 'Smart Microchip Proppants' Technology for Precision Diagnostics of Hydraulic Fracture Networks (Edited Final Report)

This project introduces innovative technology to improve subsurface characterization, visualization, and diagnostics of unconventional reservoirs (fossil resources). Through a collaborative effort involving the University of Kansas, UCLA, MicroSilicon Inc., and EOG Resources, the project aims to deliver precision diagnostics for hydraulic fractures using novel high-resolution imaging technology based on smart microchip proppants. Additionally, it seeks to enhance the accuracy and predictability of integrated numerical, and machine-learning modeling techniques for hydraulic fracture characterization and simulation. This groundbreaking technology addresses significant gaps in understanding unconventional and tight reservoir behavior and optimizing well-completion strategies, enabling more cost-efficient recovery of unconventional resources.

02 PETROLEUM↗

Pediatric Tuberculosis: The Impact of “Omics” on Diagnostics Development

Tuberculosis (TB) is a major public health concern for all ages. However, the disease presents a larger challenge in pediatric populations, partially owing to the lack of reliable diagnostic standards for the early identification of infection. Currently, there are no biomarkers that have been clinically validated for use in pediatric TB diagnosis. Identification and validation of biomarkers could provide critical information on prognosis of disease, and response to treatment. In this review, we discuss how the “omics” approach has influenced biomarker discovery and the advancement of a next generation rapid point-of-care diagnostic for TB, with special emphasis on pediatric disease. Limitations of current published studies and the barriers to their implementation into the field will be thoroughly reviewed within this article in hopes of highlighting future avenues and needs for combating the problem of pediatric tuberculosis.

59 BASIC BIOLOGICAL SCIENCES↗

Ultra-Compact Neuroprocessor for Automotive Diagnostic and Control

Demands on the performance of vehicle control and diagnostic systems are steadily increasing as a consequence of stiff global competition and government mandates. In the United States, light trucks and passenger cars are required both to meet strict emission standards and to perform continuous diagnostics of all emissions systems operating in the vehicle.

Neuroprocessor automotive diagnostics↗

Diagnostic Reasoning using Prognostic Information for Unmanned Aerial Systems

With increasing popularity of unmanned aircraft, continuous monitoring of their systems, software, and health status is becoming more and more important to ensure safe, correct, and efficient operation and fulfillment of missions. The paper presents integration of prognosis models and prognostic information with the R2U2 (REALIZABLE, RESPONSIVE, and UNOBTRUSIVE Unit) monitoring and diagnosis framework. This integration makes available statistically reliable health information predictions of the future at a much earlier time to enable autonomous decision making. The prognostic information can be used in the R2U2 model to improve diagnostic accuracy and enable decisions to be made at the present time to deal with events in the future. This will be an advancement over the current state of the art, where temporal logic observers can only do such valuation at the end of the time interval. Usefulness and effectiveness of this integrated diagnostics and prognostics framework was demonstrated using simulation experiments with the NASA Dragon Eye electric unmanned aircraft.

Diagnostics↗