Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Developing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Development of techniques for gantryless associated-particle imaging

To move fast-neutron radiography using the associated-particle imaging technique from the laboratory to the field, the development of new analysis techniques is required. In particular, the relative positions of the source and detectors need to be determined when they have been placed by hand, the normalization for a particular source–detector geometry needs to be determined without a measurement in the same geometry with no object present, and accurate image stitching is required when multiple detector positions are necessary to image an object. The present work describes methods that employ transmission neutron data to localize a fast-neutron imaging panel with respect to the neutron source, calculate a normalization for a given source–detector geometry, stitch images together, and describes the required system calibrations. The reported techniques enable in-field neutron radiography for cases in which the source–detector geometry is not well known a priori and where operational constraints preclude a normalization measurement.

Heath, Matthew↗

Advanced low-beta cavity development for proton and ion accelerators

Recent developments in designing and processing low-beta superconducting cavities at Argonne National Laboratory are very encouraging for future applications requiring compact proton and ion accelerators. One of the major benefits of these accelerating structures is achieving real-estate accelerating gradients greater than 3 MV/m very efficiently either continuously or for long-duty cycle operation (>1%). The technology has been implemented in low-beta accelerator cryomodules for the Argonne ATLAS heavy-ion linac where the cryomodules are required to have real-estate gradients of more than 3 MV/m. In offline testing low-beta cavities with even higher gradients have already been achieved. This paper will review this work where we have achieved surface fields greater than 166 mT magnetic and 117 MV/m electric in a 72 MHz quarter-wave resonator optimized for beta = 0.077 ions.

Heavy Ion Accelerators↗

Knockdown of NLE1 inhibits development of malignant melanoma in vitro and in vivo NLE1 promotes development of malignant melanoma

Melanoma, which originates from neural crest derived melanocytes, causes severe pain and even death to numerous patients. Previous studies reported that Notchless Homolog 1 (NLE1) plays an important role in cell proliferation, transcription and signal transduction. However, the clinical significance and biological behavior of NLE1 in melanoma remain a mystery. Thus, the role of NLE1 in melanoma was investigated in vitro and in vivo. The expression of NLE1 in melanoma was elevated and the expression level was positively correlated with lymphatic metastasis and tumor stage. In addition, NLE1 knockdown by shRNA specifically inhibited proliferation, enhanced the apoptotic sensitivity and hindered migration of melanoma cells in vitro. Mice xenograft model further showed that NLE1 knockdown could inhibit the tumor formation of melanoma in vivo. Additionally, the induction of apoptosis of melanoma cells by NLE1 knockdown required the participation of a series of apoptosis-related proteins. Besides, NLE1 can activate the PI3K/AKT signaling pathway. In summary, NLE1 was involved in the development and progression of melanoma, which may be a novel potential target for molecular therapy of melanoma.

60 APPLIED LIFE SCIENCES↗

Developing Scaling Relationships for Molecular Electrocatalysis through Studies of Fe-Porphyrin-Catalyzed O 2 Reduction

The oxygen reduction reaction (ORR) is a multiproton/multielectron transformation in which dioxygen (O 2 ) is reduced to water or hydrogen peroxide and serves as the cathode reaction in most fuel cells. The ORR (O 2 + 4e – + 4H + → 2H 2 O) involves up to nine substrates and thus requires navigating a complicated reaction landscape, typically with several high-energy intermediates. Many catalysts can perform this reaction, though few operate with fast rates and at low overpotentials (close to the thermodynamic potential). Attempts to optimize these parameters, both in homogeneous and heterogeneous electrocatalytic systems, have focused on modifying catalyst design and understanding kinetic/thermodynamic relationships between catalytic intermediates. One such method for analyzing and predicting catalyst reactivity and efficiency has been the development of “molecular scaling relationships”. In this work, we share our experience deriving and utilizing molecular scaling relationships for soluble, iron-porphyrin-catalyzed O 2 reduction in organic solvents. These relationships correlate turnover frequencies (TOF max ) and effective overpotentials (η eff ), properties uniquely defined for homogeneous catalysts. Following a general introduction of scaling relationships for both homogeneous and heterogeneous electrocatalysis, we describe the components of such scaling relationships: (i) the overall thermochemistry of the reaction and (ii) the rate and rate law of the catalyzed reaction. We then show how connecting these thermodynamic and kinetic parameters reveals multiple molecular scaling relationships for iron-porphyrin-catalyzed O 2 reduction. For example, the log(TOF max ) responds steeply to changes in ηeff that result from different catalyst reduction potentials (18.5 decades in TOF max /V in η eff ) but much less dramatically to changes in η eff that arise from varying the pKa of the acid buffer (5.1 decades in TOF max /V in η eff ). Thus, a single scaling relationship is not always sufficient for describing molecular electrocatalysis. This is particularly evident when the catalyst identity and reaction conditions are coupled. Using these multiple scaling relationships, we demonstrate that the metrics of turnover frequency and effective overpotential can be predictably tuned to achieve faster rates at lowered overpotentials. This Account uses a collection of related stories describing our research on soluble iron-porphyrin-catalyzed ORR to show how molecular scaling relationships can be derived and used for any electrocatalytic reaction. Such scaling relationships are powerful tools that connect the thermochemistry, mechanism, and rate law for a catalytic system. We hope that this collection shows the utility and simplicity of the molecular scaling approach for understanding catalysis, for enabling direct comparisons between catalyst systems, and for optimizing catalytic processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Toward the Development of a High-Voltage Mg Cathode Using a Chromium Sulfide Host

Development of Mg-ion batteries as advanced electrochemical energy storage systems relies on the design and discovery of high-voltage positive electrode (cathode) materials. To date, a variety of sulfide cathodes have been reported (e.g., Mg x Mo 6 S 8 , Mg x Ti 2 S4, etc.), but the voltages of these materials are too low to prepare a high energy density Mg cell. Theoretical computations predicted that Mg x Cr 2 S 4 operating with the high-voltage Cr 3+/4+ redox couple would serve as a suitable cathode candidate, but experimental attempts to extract Mg 2+ from the lattice have been largely unsuccessful. Here, we show that reversible electrochemical activity within a thiospinel framework (AB 2 S 4 ) relies on a redox-active transition metal present in the B site; otherwise, anionic redox activity triggers decomposition of the spinel structure. Since Cr and S states are highly coupled in MgCr 2 S 4 , the Cr 3+/4+ redox couple is inaccessible so that reversible (de)intercalation of Mg 2+ cannot occur and charging leads to dissolution of the active material. These findings point to an insufficiency in the screening criteria previously used to identify MgCr 2 S 4 as a promising Mg cathode. Thus, a computable descriptor based on the electronic structure of the discharged material is proposed to predict the prevalence of cation vs anion redox and improve future surveys of potential candidates. It is unlikely that the high-voltage Cr redox couple will be accessible to oxidation in the presence of sulfur within the restrictions of a spinel framework; however, it is possible that a suitable layered Mg x CrS 2 structure could serve as a reversible high-voltage Mg cathode.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of Lipid-Coated Semiconductor Nanosensors for Recording of Membrane Potential in Neurons

In the past decade, optical imaging methods have significantly improved our understanding of the information processing principles in the brain. Although many promising tools have been designed, sensors of membrane potential are lagging behind the rest. Semiconductor nanoparticles are an attractive alternative to classical voltage indicators, such as voltage-sensitive dyes and proteins. Such nanoparticles exhibit high sensitivity to external electric fields via the quantum-confine Stark effect. Here we report the development of semiconductor voltage-sensitive nanorods (vsNRs) that self-insert into the neuronal membrane. To facilitate interaction of the nanorods with the membrane, we functionalized their surface with the lipid mixture derived from brain extract. We describe a workflow to detect and process the photoluminescent signal of vsNRs after widefield time-lapse recordings. We also present data indicating that vsNRs are feasible for sensing membrane potential in neurons at a single-particle level. This shows the potential of vsNRs for the detection of neuronal activity with unprecedentedly high spatial and temporal resolution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Uranium recovery from seawater: development of fiber adsorbents prepared via atom-transfer radical polymerization

We developed a novel adsorbent preparation method using atom-transfer radical polymerization (ATRP) combined with radiation-induced graft polymerization (RIGP) in order to synthesize an adsorbent for uranium recovery from seawater. Furthermore, the ATRP method allowed a much higher degree of grafting on the adsorbent fibers (595 2818%) than that allowed by RIGP alone. The adsorbents were prepared with varied composition of amidoxime groups and hydrophilic acrylate groups. The successful preparation revealed that both ligand density and hydrophilicity were critical for optimal performance of the adsorbents. Adsorbents synthesized in this study showed a relatively high performance (141 179 mg/g at 49 62 % adsorption) in laboratory screening tests using a uranium concentration of ~6 ppm. This performance is much higher than that of known commercial adsorbents. However, actual seawater experiment showed impeded performance compared to the recently reported high-surface-area-fiber adsorbents, due to slow adsorption kinetics. The impeded performance motivated an investigation of the effect of hydrophilic block addition on the graft chain terminus. The addition of hydrophilic block on the graft chain terminus nearly doubled the uranium adsorption capacity in seawater, from 1.56 mg/g to 3.02 mg/g. Our investigation revealed the importance of polymer chain conformation, in addition to ligand and hydrophilic group ratio, for advanced adsorbent synthesis for uranium recovery from seawater.

07 ISOTOPE AND RADIATION SOURCES↗

Development of the C{sup 6+} laser ablation ion source for the KEK digital accelerator

A laser ion source that provides a fully ionized carbon ion beam is under joint development at the High Energy Accelerator Research Organization and Brookhaven National Laboratory. Long-pulse (6 ns) and short-pulse (500 ps) laser systems were tested by using them to irradiate a graphite target. Notable differences between the systems were observed in these experiments. Preliminary experimental results, such as the charge-state spectrum, beam intensity, and stability, are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a dual MCP framing camera for high energy x-rays

Recently developed diagnostic techniques at LLNL require recording backlit images of extremely dense imploded plasmas using hard x-rays, and demand the detector to be sensitive to photons with energies higher than 50 keV [R. Tommasini et al., Phys. Phys. Plasmas 18, 056309 (2011); G. N. Hall et al., “AXIS: An instrument for imaging Compton radiographs using ARC on the NIF,” Rev. Sci. Instrum. (these proceedings)]. To increase the sensitivity in the high energy region, we propose to use a combination of two MCPs. The first MCP is operated in a low gain regime and works as a thick photocathode, and the second MCP works as a high gain electron multiplier. We tested the concept of this dual MCP configuration and succeeded in obtaining a detective quantum efficiency of 4.5% for 59 keV x-rays, 3 times larger than with a single plate of the thickness typically used in NIF framing cameras.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a new virtual diagnostic for V3FIT

The determination of plasma equilibria from diagnostic information is a fundamental issue. V3FIT is a fully three-dimensional reconstruction code capable of solving the inverse problem using both magnetic and kinetic measurements. It uses VMEC as core equilibrium solver and supports both free- and fixed-boundary reconstruction approaches. In fixed-boundary mode VMEC does not use explicit information about currents in external coils, even though it has important effects on the shape of the safety factor profile. Indeed, the edge safety factor influences the reversal position in RFP plasmas, which then determines the position of the m = 0 island chain and the edge transport properties. In order to exploit such information a new virtual diagnostic has been developed, that thanks to Ampère's law relates the external current through the center of the torus to the circulation of the toroidal magnetic field on the outermost flux surface. The reconstructions that exploit the new diagnostic are indeed found to better interpret the experimental data with respect to edge physics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a reduced model of formation reactions in Zr-Al nanolaminates

A computational model of anaerobic reactions in metallic multilayered systems with an equimolar composition of zirconium and aluminum is developed. The reduced reaction formalism of M. Salloum and O. M. Knio, Combust. Flame 157(2): 288–295 (2010) is adopted. Attention is focused on quantifying intermixing rates based on experimental measurements of uniform ignition as well as measurements of self-propagating front velocities. Estimates of atomic diffusivity are first obtained based on a regression analysis. A more elaborate Bayesian inference formalism is then applied in order to assess the impact of uncertainties in the measurements, potential discrepancies between predictions and observations, as well as the sensitivity of predictions to inferred parameters. Intermixing rates are correlated in terms of a composite Arrhenius law, which exhibits a discontinuity around the Al melting temperature. Analysis of the predictions indicates that Arrhenius parameters inferred for the low-temperature branch lie within a tight range, whereas the parameters of the high-temperature branch are characterized by higher uncertainty. The latter is affected by scatter in the experimental measurements, and the limited range of bilayers where observations are available. For both branches, the predictions exhibit higher sensitivity to the activation energy than the pre-exponent, whose posteriors are highly correlated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of an interpretive simulation tool for the proton radiography technique

Proton radiography is a useful diagnostic of high energy density (HED) plasmas under active theoretical and experimental development. In this paper, we describe a new simulation tool that interacts realistic laser-driven point-like proton sources with three dimensional electromagnetic fields of arbitrary strength and structure and synthesizes the associated high resolution proton radiograph. The present tool’s numerical approach captures all relevant physics effects, including effects related to the formation of caustics. Electromagnetic fields can be imported from particle-in-cell or hydrodynamic codes in a streamlined fashion, and a library of electromagnetic field “primitives” is also provided. This latter capability allows users to add a primitive, modify the field strength, rotate a primitive, and so on, while quickly generating a high resolution radiograph at each step. In this way, our tool enables the user to deconstruct features in a radiograph and interpret them in connection to specific underlying electromagnetic field elements. We show an example application of the tool in connection to experimental observations of the Weibel instability in counterstreaming plasmas, using ∼10{sup 8} particles generated from a realistic laser-driven point-like proton source, imaging fields which cover volumes of ∼10 mm{sup 3}. Insights derived from this application show that the tool can support understanding of HED plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Developing a robust sensor for infrared imaging bolometers

A new type of large area sensor for infrared imaging bolometers has been developed. It replaces the thin and fragile free-standing metal foils, which typically have been used, with a multi-layer coated sapphire (or diamond) substrate. Sapphire is transparent to mid-infrared wavelengths, is robust against transients, and can be thick enough to even be the vacuum window. The primary radiation absorber is still a thin deposited metal layer, but now it is partially insulated from the supporting sapphire substrate by a black (carbon-based) layer, which also acts as a blackbody remitter. Test results indicate 6× more noise equivalent power density (estimated NEPD = 23 W/m 2 at 5 ms camera exposure time, foil temperature decay time 60 ms) for a 2 μm gold-coated sapphire disk compared to estimated NEP = 4 W/m 2 at 1.8 ms exposure time, with foil decay time 420 ms, for a nominal 2.5 μm thick platinum-free-standing foil.

47 OTHER INSTRUMENTATION↗