Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Determination and Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Determination of the stability and control derivatives of the F/A-18 HARV from flight data using the maximum likelihood method

The research being conducted pertains to the determination of the stability and control derivatives of the F/A-18 High Alpha Research Vehicle (HARV) from flight data using the Maximum Likelihood Method. The document outlines the approach used in the parameter estimation (PID) process and briefly describes the mathematical modeling of the F/A-18 HARV and the maneuvers designed to generate a sufficient data base for the PID research.

Napolitano, Marcello R.↗

PhyCA-PhyloChip Analysis

PhyCA allows interpretation of a PhyloChip assay. It takes as input, a text file containing the fluorescent intensity from each feature on the microarray surface. PhyCA will determine the background and noise levels, compare probes against controls and determine response scores for each probe pair. It then summarizes a set of probe pair results to determine presence of an operational taxonomic unit as well as its abundance. The PhyCA software is novel from other microarray interpretation software from the following reasons: 1) It leverages spiked-in Quantitative Standards and non-spike-in Negative Controls to build a per-chip model of positive and non-positive responses. 2) It allows a refinement of Presence/Absence calls by evaluating each responding probe against a putative cross-hybridization network. 3) It can be used with phylogenetic microarrays designed for Bacteria, Archaea or Eukaryotes. Hardware req.: PC, MAC; Software req.: OS: Windows, Mac, Linux; Types of files: source code, control information; user guide. The software depends on other software to be installed on the same machine as PhyCA.

Desantis, Todd↗

STS payloads mission control study, executive summary briefing

The following study objectives were investigated and results are briefly discussed: (1) identify flight control ground functions for representative STS payloads, (2) investigate present/planned NASA-wide facilities for STS payload control, (3) determine feasible, cost effective system concept options for flight control of STS payloads, and (4) development of implementation guidelines for proposed concept option(s).

Source record↗

Interaction of the Space Shuttle on-orbit autopilot with tether dynamics

The effect of Orbiter flight control on tether dynamics is studied by simulation. Open-loop effects of Orbiter jet firing on tether dynamics are shown, and the potential for closed-loop interaction between tether dynamics and Orbiter flight control is determined. The significance of these effects on Orbiter flight control and tether control is assessed.

Bergmann, Edward V.↗

Dynamic attitude command and control of the TOPEX/Poseidon spacecraft

The dynamic control laws utilized by the TOPEX/Poseidon (T/P) spacecraft attitude determination and control subsystem to command and maneuver the satellite during normal mission mode (NMM) laws are described. Results show that the vehicle is able to respond to the dynamic attitude commands while at the same time providing ample disturbance rejection capability.

Zimbelman, D. F.↗

On-orbit performance of the Extended Gyrocompass Controller for the TOPEX/Poseidon spacecraft

The paper describes the Earth Acquisition Mode Extended Gyrocompass Controller flown aboard the NASA-CNES TOPEX/Poseidon Attitude Determination and Control Subsystem spacecraft for providing highly accurate measurements of the surface elevations over all the ocean basins. Particular attention is given to the on-orbit performance of the Extended Gyrocompass Controller used during quaternion initialization and Update Filter convergence processing, both of these procedures requiring maintenance of the spacecraft attitude control and knowledge. The development of the Extended Gyrocompass control technique is reviewed, and the results of the on-orbit yaw attitude control and knowledge performance provided by this algorithm are presented.

Sanneman, P. A.↗

Grid Interactive Microgrid Controller for Resilient Communities (Final Report)

The objective of this project was to determine microgrid controller requirements using a use-case approach, then develop, configure and validate the performance of an advanced microgrid controller capable of managing from 1 to 10 megawatts (MW) of aggregated generation capacity to meet the performance targets outlined in DOE Funding Opportunity Announcement (FOA) DE-FOA-0000997 “Microgrid Research, Development, and System Design” and support the expanding deployment of commercial scale microgrid systems. The project aimed to develop and validate a commercially viable and flexible microgrid controller, easily adapted to different end-user community applications and to a range of electric grid characteristics with the primary outcome of the project being a standard operational model that can be deployed at multiple communities, each with unique resources and resiliency requirements. Spirae’s Wave™ microgrid controller was the advanced microgrid controller utilized in this project. The Spirae Wave™ control platform provides a scalable architecture for integrating and managing high levels of renewable and distributed energy resources (DER) at the edge of the grid. The motivation for the project is a result of the increased interest in microgrids resulting from the confluence of a number of important factors 1) Costs of distributed generation of many different types continues to decrease. This includes gas-based generation that has benefited from the lower cost of natural gas as well as renewable generation (solar, wind, hydro), 2) Storage development for many different industries is lowering its cost for the electric power industry. Storage is a key element of a microgrid to provide the flexibility of operation needed, 3) Applications like combined heat and power further improve the economics of local generation and provide the opportunity for local optimization of resources and loads, 4) There continues to be a need for improved resiliency and coordination of local system strategies (e.g. microgrids) with overall grid investments that can result in more optimum overall investment strategies and reduced times to restore power after major events. The increased interest in microgrids as both a system for local energy optimization and for improved resiliency comes with a need for new controller strategies that can help realize these applications. The new controllers should also reflect industry standards and provide a platform for continued innovation. Additionally, the controllers should be flexible to adapt to a wide variety of end-user community applications and to a wide range of electric grid characteristics. The controller should be equipped with standard functions and interfaces that can expand community opportunities for microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Determining the potential productivity of food crops in controlled environments

The quest to determine the maximum potential productivity of food crops is greatly benefitted by crop growth models. Many models have been developed to analyze and predict crop growth in the field, but it is difficult to predict biological responses to stress conditions. Crop growth models for the optimal environments of a Controlled Environment Life Support System (CELSS) can be highly predictive. This paper discusses the application of a crop growth model to CELSS; the model is used to evaluate factors limiting growth. The model separately evaluates the following four physiological processes: absorption of PPF by photosynthetic tissue, carbon fixation (photosynthesis), carbon use (respiration), and carbon partitioning (harvest index). These constituent processes determine potentially achievable productivity. An analysis of each process suggests that low harvest index is the factor most limiting to yield. PPF absorption by plant canopies and respiration efficiency are also of major importance. Research concerning productivity in a CELSS should emphasize: (1) the development of gas exchange techniques to continuously monitor plant growth rates and (2) environmental techniques to reduce plant height in communities.

Bugbee, Bruce↗

Comparison of Wind-Tunnel and Flight Measurements of Stability and Control Characteristics of a Douglas A-26 Airplane

Stability and control characteristics determined from tests in the Langley 19-foot pressure tunnel of a 0.2375-scale model of the Douglas XA-26 airplane are compared with those measured in flight tests of a Douglas A-26 airplane. Agreement regarding static longitudinal stability as indicated by the elevator-fixed neutral points and by the variation of elevator deflection in both straight and turning flight was found to be good except at speeds approaching the stall. At these low speeds the airplane possessed noticeably improved stability, which was attributed to pronounced stalling at the root of the production wing. The pronounced root stalling did not occur on the smooth, well-faired model wing. Elevator tab effectiveness determined from model tests agreed well with flight-test tab effectiveness, but control-force variations with speed and acceleration were not in good agreement. The use of model hinge-moment data obtained at zero sideslip appeared to be satisfactory for the determination of aileron forces in sideslip. Fairly good correlation in aileron effectiveness and control forces was obtained; fabric distortion may have been responsible to some extent for higher flight values of aileron force at high speeds. Estimation of sideslip developed in an abrupt aileron roll was fair, but determination of the rudder deflection required to maintain zero sideslip in a rapid aileron roll was not entirely satisfactory.

Kayten, Gerald G↗

Method and apparatus for characterizing propagation delays of integrated circuit devices

Propagation delay of a signal through a channel is measured by cyclically generating a first step-wave signal for transmission through the channel to a two-input logic element and a second step-wave signal with a controlled delay to the second input terminal of the logic element. The logic element determines which signal is present first at its input terminals and stores a binary signal indicative of that determination for control of the delay of the second signal which is advanced or retarded for the next cycle until both the propagation delayed first step-wave signal and the control delayed step-wave signal are coincident. The propagation delay of the channel is then determined by measuring the time between the first and second step-wave signals out of the controlled step-wave signal generator.

Blaes, Brent R.↗

Space tug thermal control

It was determined that space tug will require the capability to perform its mission within a broad range of thermal environments with currently planned mission durations of up to seven days, so an investigation was conducted to define a thermal design for the forward and intertank compartments and fuel cell heat rejection system that satisfies tug requirements for low inclination geosynchronous deploy and retrieve missions. Passive concepts were demonstrated analytically for both the forward and intertank compartments, and a worst case external heating environment was determined for use during the study. The thermal control system specifications and designs which resulted from the research are shown.

Source record↗

Model Predictive Control of HVAC Systems: Implementation and Testing at the University of California, Merced

A Model Predictive Control algorithm was developed for the UC Merced campus chilled water plant. Model predictive control (MPC) is an advanced control technology that has proven successful in the chemical process industry and other industries. The main goal of the research was to demonstrate the practical and commercial viability of MPC for optimization of building energy systems. The control algorithms were developed and implemented in MATLAB, allowing for rapid development, performance, and robustness assessment. The UC Merced chilled water plant includes three water-cooled chillers and a two million gallon chilled water storage tank. The tank is charged during the night to minimize on-peak electricity consumption and take advantage of the lower ambient wet bulb temperature. The control algorithms determined the optimal chilled water plant operation including chilled water supply (CHWS) temperature set-point, condenser water supply (CWS) temperature set-point and the charging start and stop times to minimize a cost function that includes energy consumption and peak electrical demand over a 3-day prediction horizon. A detailed model of the chilled water plant and simplified models of the buildings served by the plant were developed using the equation-based modeling language Modelica. Steady state models of the chillers, cooling towers and pumps were developed, based on manufacturers performance data, and calibrated using measured data collected and archived by the control system. A detailed dynamic model of the chilled water storage tank was also developed and calibrated. Simple, semi-empirical models were developed to predict the temperature and flow rate of the chilled water returning to the plant from the buildings. These models were then combined and simplified for use in a model predictive control algorithm that determines the optimal chiller start and stop times and set-points for the condenser water temperature and the chilled water supply temperature. The report describes the development and testing of the algorithm and evaluates the resulting performance, concluding with a discussion of next steps in further research. The experimental results show a small improvement in COP over the baseline policy but it is difficult to draw any strong conclusions about the energy savings potential for MPC with this system only four days of suitable experimental data were obtained once correct operation of the MPC system had been achieved. These data show an improvement in COP of 3.1% {+-} 2.2% relative to a baseline established immediately prior to the period when the MPC was run in its final form. This baseline includes control policy improvements that the plant operators learned by observing the earlier implementations of MPC, including increasing the temperature of the water supplied to the chiller condensers from the cooling towers. The process of data collection and model development, necessary for any MPC project, resulted in the team uncovering various problems with the chilled water system. Although it is difficult to quantify the energy savings resulting from these problems being remedied, they were likely on the same order as the energy savings from the MPC itself. Although the types of problems uncovered and the level of energy savings may differ significantly from other projects, some of the benefits of detecting and diagnosing problems are expected from the use of MPC for any chilled water plant. The degree of chiller loading was found to be a key factor for efficiency. It is more efficient to operate the chillers at or near full load. In order to maximize the chiller load, one would maximize the temperature difference across chillers and the chilled water flow rate through the chillers. Thus, the CHWS set-point and the chilled water flow-rate can be used to limit the chiller loading to prevent chiller surging. Since the flow rate has an upper bound and the CHWS set point has a lower bound, the chiller loading is constrained and often determined by the chilled water return temperature (CHWR). The CHWR temperature is primarily comprised of warm water from the top of the TES tank. The CHWR temperature falls substantially as the thermocline approaches the top of the tank, which reduces the chiller loading. As a result, it has been determined that overcharging the TES tank can be detrimental to the chilled water plant efficiency. The resulting MPC policy differs from the current practice of fully charging the TES tank. A heuristic rule could possible avoid this problem without using predictive control. Similarly, the COP improvements from the change in CWS set-point were largely captured by a static set-point change by the operators. Further research is required to determine how much of the MPC savings could be garnered through simplified rules (based on the MPC study), with and without prediction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Robust time-domain identification of mass stiffness, and damping matrices

Accurate estimates of the mass, stiffness, and damping characteristics of a structure is necessary for determining the control laws best suited for active control methodologies. There are several modal identification techniques available for determining the frequencies, damping ratios, and mode shapes of a structure. However, modal identification methods in both the frequency and time domains have difficulties for certain circumstances. Frequency domain techniques which utilize the steady-state response from various harmonic inputs often encounter difficulties when the frequencies are closely distributed, the structure exhibits a high degree of damping, or the steady-state condition is hard to establish. Time domain techniques have produced successful results, but lack robustness with respect to measurement noise. In this paper, two identification techniques and an estimation method are combined to form a time-domain technique to accurately identify the mass, stiffness, and damping matrices from noisy measurements.

Roemer, Michael J.↗

LED lamp color control system and method

An LED lamp color control system and method including an LED lamp having an LED controller 58; and a plurality of LED channels 60 operably connected to the LED controller 58, each of the plurality of LED channels 60 having a channel switch 62 in series with at least one shunted LED circuit 83, the shunted LED circuit 83 having a shunt switch 68 in parallel with an LED source 80. The LED controller 58 determines whether the LED source 80 is in a feedback controllable range, stores measured optical flux for the LED source 80 when the LED source 80 is in the feedback controllable range, and bypasses storing the measured optical flux when the LED source 80 is not in the feedback controllable range.

47 OTHER INSTRUMENTATION↗

Development of a dynamic flow imaging phantom for dynamic contrast-enhanced CT

Purpose: Dynamic contrast enhanced CT (DCE-CT) studies with modeling of blood flow and tissue perfusion are becoming more prevalent in the clinic, with advances in wide volume CT scanners allowing the imaging of an entire organ with sub-second image frequency and sub-millimeter accuracy. Wide-spread implementation of perfusion DCE-CT, however, is pending fundamental validation of the quantitative parameters that result from dynamic contrast imaging and perfusion modeling. Therefore, the goal of this work was to design and construct a novel dynamic flow imaging phantom capable of producing typical clinical time-attenuation curves (TACs) with the purpose of developing a framework for the quantification and validation of DCE-CT measurements and kinetic modeling under realistic flow conditions. Methods: The phantom is based on a simple two-compartment model and was printed using a 3D printer. Initial analysis of the phantom involved simple flow measurements and progressed to DCE-CT experiments in order to test the phantoms range and reproducibility. The phantom was then utilized to generate realistic input TACs. A phantom prediction model was developed to compute the input and output TACs based on a given set of five experimental (control) parameters: pump flow rate, injection pump flow rate, injection contrast concentration, and both control valve positions. The prediction model is then inversely applied to determine the control parameters necessary to generate a set of desired input and output TACs. A protocol was developed and performed using the phantom to investigate image noise, partial volume effects and CT number accuracy under realistic flow conditionsResults: This phantom and its surrounding flow system are capable of creating a wide range of physiologically relevant TACs, which are reproducible with minimal error between experiments ({sigma}/{mu} < 5% for all metrics investigated). The dynamic flow phantom was capable of producing input and output TACs using either step function based or typical clinical arterial input function (AIF) inputs. The measured TACs were in excellent agreement with predictions across all comparison metrics with goodness of fit (R{sup 2}) for the input function between 0.95 and 0.98, while the maximum enhancement differed by no more than 3.3%. The predicted output functions were similarly accurate producing R{sup 2} values between 0.92 and 0.99 and maximum enhancement to within 9.0%. The effect of ROI size on the arterial input function (AIF) was investigated in order to determine an operating range of ROI sizes which were minimally affected by noise for small dimensions and partial volume effects for large dimensions. It was possible to establish the measurement sensitivity of both the Toshiba (ROI radius range from 1.5 to 3.2 mm ''low dose'', 1.4 to 3.0 mm ''high dose'') and GE scanner (1.5 to 2.6 mm ''low dose'', 1.1 to 3.4 mm ''high dose''). This application of the phantom also provides the ability to evaluate the effect of the AIF error on kinetic model parameter predictions. Conclusions: The dynamic flow imaging phantom is capable of producing accurate and reproducible results which can be predicted and quantified. This results in a unique tool for perfusion DCE-CT validation under realistic flow conditions which can be applied not only to compare different CT scanners and imaging protocols but also to provide a ground truth across multimodality dynamic imaging given its MRI and PET compatibility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

1999 Flight Mechanics Symposium

This conference publication includes papers and abstracts presented at the Flight Mechanics Symposium held on May 18-20, 1999. Sponsored by the Guidance, Navigation and Control Center of Goddard Space Flight Center, this symposium featured technical papers on a wide range of issues related to orbit-attitude prediction, determination, and control; attitude sensor calibration; attitude determination error analysis; attitude dynamics; and orbit decay and maneuver strategy. Government, industry, and the academic community participated in the preparation and presentation of these papers.

John P. Lynch↗