Design and Analysis of a Single-Shot Longitudinal Phase Space Measurement Diagnostics at the Argonne Wakefield Accelerator

A single-shot longitudinal phase space diagnostics is currently being assembled at the Argonne Wakefield Accelerator (AWA). The diagnostics consists of mapping the longitudinal phase space coordinates to the transverse position space plane using a beamline that incorporates two magnetic dipoles arranged as a dogleg followed by an rf deflecting cavity. The deflecting cavity streaks the beam vertically while the dipole magnets bend horizontally. In this paper, we analyze analytically and via numerical simulations the performances of such diagnostics and their limitations. Simulations done in IMPACT-T shows good reconstruction of the longitudinal phase space.

43 PARTICLE ACCELERATORS↗

Analysis and design of terahertz antennas based on plasmonic resonant graphene sheets

Resonant graphene antennas used as true interfaces between terahertz (THz) space waves and a source/detector are presented. It is shown that in addition to the high miniaturization related to the plasmonic nature of the resonance, graphene-based THz antenna favorably compare with typical metal implementations in terms of return loss and radiation efficiency. Graphene antennas will contribute to the development of miniature, efficient, and potentially transparent all-graphene THz transceivers for emerging communication and sensing application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temperature modeling for analysis and design of the sintering furnance in HTR fuel type of ball

One of the factors that determine the safety of the operation of the sintering furnace fuel HTR ball is the temperature distribution in the ceramic tube furnace. The temperature distribution must be determined at design stage. The tube has a temperature of 1600 °C at one end and about 40 °C at the other end. The outside of the tube was cooled by air through natural convection. The tube is a furnace ceramic tube which its geometry are 0.08, 0.09 and 0.5 m correspondingly for the inner tube diameter, outer tube diameter and tube length. The temperature distribution of the tube is determined by the natural convection coefficient (NCF), which is difficult to be calculated manually. The determination of NCF includes the Grasshoff, Prandtl, and Nusselt numbers which is a function of the temperature difference between the surrounding air with the ceramic tube. If the temperature vary along the tube, the complexity of the calculations increases. Thus the proposed modeling was performed to determine the temperature distribution along the tube and heat transfer coefficient using a self-developed software which permit the design process easier.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Analysis and design of nonlocal spin devices with electric-field-induced spin-transport acceleration

We apply electric-field-induced acceleration for spin transport to a four-terminal nonlocal device and theoretically analyze its Hanle-effect signals. The effect of the ferromagnetic contact widths of the spin injector and detector on the signals is carefully discussed. Although Hanle-effect signals are randomized owing to the effect of the contact widths, this can be excluded by selecting an appropriate electric field for acceleration of spin transport. Spin lifetime can be correctly extracted by nonlocal devices with electric-field acceleration even using the spin injector and detector with finite contact widths.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design and analysis of dudded fuel experiments at the National Ignition Facility

Recent experiments conducted at the National Ignition Facility (NIF) within the past 2 years have achieved the burning plasma state and exceeded the Lawson criterion for the first time in the laboratory. Here, we report on a set of experiments where the deuterium and tritium (DT) ice layers were replaced with dudded tritium, hydrogen, and deuterium (THD) fuel mixtures to remove the influence of alpha-heating on hot spot dynamics. The hot spot compression and yield in the absence of alpha particle self-heating were measured to assess the proximity of NIF implosions toward the ignition cliff. We find that the “burn-off” Lawson parameters χnoα inferred from the THD experiments are in good agreement with the inferences from postshot simulations of the DT-layered implosions. The THD for burning plasma shot N210307 yielded χnoα≈0.88±0.03 while the THD for ignition shot N210808 yielded χnoα≈1.04±0.04. These results also provide important context for the observed variability in the repeat attempts of ignition shot N210808 since implosions on the ignition cliff are expected to exhibit very large variations in the fusion yield from small changes in the initial conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Humidified single-scattering albedometer (H-CAPS-PM SSA ): Design, data analysis, and validation

In this work, we report the development and validation of a new humidified aerosol single-scattering albedometer to quantify the effects of water uptake on submicrometer particle optical properties. The instrument simultaneously measures in situ aerosol light extinction ( σ ep ) and scattering ( σ sp ) using a cavity-attenuated phase shift-single scattering albedo particulate matter (PM) monitor (CAPS-PM SSA , Aerodyne Research, Inc., Billerica, MA, USA). It retrieves by difference aerosol light absorption ( σ ap ) and directly quantifies aerosol single-scattering albedo (SSA), the aerosol “brightness.” We custom built a relative humidity (RH) control system using a water vapor-permeable membrane humidifier and coupled it to the CAPS-PM SSA to enable humidified aerosol observations. Our humidified instrument (H-CAPS-PM SSA ) overcomes problems with noise caused by mirror purge-flow humidification, heating, and characterizing cell RH. Careful angular truncation corrections in scattering, particularly for larger particles, were combined with empirical observations. Results show that the optimal operational size to be D p < 400 nm. The H-CAPS-PM SSA was evaluated with several pure single-component aerosols including ammonium sulfate ((NH 4 ) 2 SO 4 ), absorbing nigrosin, and levoglucosan, an organic biomass smoke tracer. The measured σ ep , σ sp , and the derived optical hygroscopicity parameter ( κ ) for size-selected ammonium sulfate are in good agreement with literature values. For dry size-selected nigrosin in the 100 < D p < 400 nm range, SSA values increased from ~0.3 to 0.65 with increasing D p . The enhancement in nigrosin σ ap at RH = 80% was a factor of 1.05–1.20 relative to dry conditions, with the larger particles showing greater enhancement. SSA increased with RH with the largest fractional enhancement measured for the smallest particles. For polydisperse levoglucosan, we measured an optical κ of 0.26 for both light extinction and scattering and negligible absorption. Our new instrument enables reliable observations of the effects of ambient humidity on mixed aerosol optical properties, particularly for light-absorbing aerosols whose climate forcing is uncertain due to measurement gaps.

54 ENVIRONMENTAL SCIENCES↗

Design and Analysis of a 200 kW Dynamic Wireless Charging System for Electric Vehicles

Dynamic wireless charging of electric vehicles can significantly alleviate or eliminate range anxiety while reducing the required on-board battery capacity. To achieve an electric vehicle charging balance with minimal infrastructure costs, power transfer levels around 200 kW are required. In this paper, a system architecture with a modularized power electronics and optimized power transfer couplers was adopted to enable efficient power transfer. A DC/DC converter was used for secondary-side charging control of the battery. The system performance was validated in an experimental setup at 120 kW with 91.31% efficiency from the DC input on the primary side to the vehicle battery.

Xue, Lincoln↗