Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DEGENERATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

(L{sub e}-L{sub {mu}-}L{sub {tau}}) discrete symmetry for heavy right-handed neutrinos and degenerate leptogenesis

The degenerate leptogenesis is studied when the degeneracy in two of the heavy right-handed neutrinos [the third one is irrelevant if {mu}-{tau} symmetry is assumed] is due to L{identical_to}(L{sub e}-L{sub {mu}-}L{sub {tau}}) discrete symmetry. It is shown that a sizable leptogenesis asymmetry ({epsilon}{>=}10{sup -6}) is possible. The level of degeneracy required also predicts the Majorana phase needed for the asymmetry and this prediction is testable since it is the same phase, which appears in the double {beta} decay. Implications of nonzero reactor angle {theta}{sub 13} are discussed. It is shown that the contribution from sin{sup 2{theta}}{sub 13} to the leptogenesis asymmetry parameter may even dominate. An accurate measurement of sin{sup 2{theta}}{sub 13} would have important implications for the mass degeneracy of heavy right-handed neutrinos.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Phase diagram of QCD with four degenerate quarks

We revisit the determination of the pseudocritical line of QCD with four degenerate quarks at nonzero temperature and baryon density by the method of analytic continuation. We determine the pseudocritical couplings at imaginary chemical potentials by high-statistics Monte Carlo simulations and reveal deviations from the simple quadratic dependence on the chemical potential visible in earlier works on the same subject. Finally, we discuss the implications of our findings for the shape of the pseudocritical line at real chemical potential, comparing different possible extrapolations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nearly degenerate gauginos and dark matter at the LHC

Motivated by dark-matter considerations in supersymmetric theories, we investigate in a fairly model-independent way the detection at the LHC of nearly degenerate gauginos with mass differences between a few GeV and about 30 GeV. Because of the degeneracy of gaugino states, the conventional leptonic signals are likely lost. We first consider the leading signal from gluino production and decay. We find that it is quite conceivable to reach a large statistical significance for the multijet plus missing energy signal with an integrated luminosity about 50 pb{sup -1} (50 fb{sup -1}) for a gluino mass of 500 GeV (1 TeV). If gluinos are not too heavy, less than about 1.5 TeV, this channel can typically probe gaugino masses up to about 100 GeV below the gluino mass. We then study the Drell-Yan type of gaugino pair production in association with a hard QCD jet, for gaugino masses in the range of 100-150 GeV. The signal observation may be statistically feasible with about 10 fb{sup -1}, but systematically challenging due to the lack of distinctive features for the signal distributions. By exploiting gaugino pair production through weak boson fusion, signals of large missing energy plus two forward-backward jets may be observable at a 4-6{sigma} level above the large SM backgrounds with an integrated luminosity of 100-300 fb{sup -1}. Finally, we point out that searching for additional isolated soft muons in the range p{sub T{approx}}3-10 GeV in the data samples discussed above may help to enrich the signal and to control the systematics. Significant efforts are made to explore the connection between the signal kinematics and the relevant masses for the gluino and gauginos, to probe the mass scales of the superpartners, in particular, the lightest supersymmetric particle dark matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

From hidden symmetry to extra dimensions: A five-dimensional formulation of the degenerate BESS model

We consider the continuum limit of a moose model corresponding to a generalization to N sites of the degenerate BESS model. The five-dimensional formulation emerging in this limit is a realization of a RS1 type model with SU(2){sub L} x SU(2){sub R} in the bulk, broken by boundary conditions and a vacuum expectation value on the infrared brane. A low-energy effective Lagrangian is derived by means of the holographic technique and corresponding bounds on the model parameters are obtained.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Instanton solutions mediating tunneling between the degenerate vacua in curved space

We investigate the instanton solution between the degenerate vacua in curved space. We show that there exist O(4)-symmetric solutions not only in de Sitter but also in both flat and anti-de Sitter space. The geometry of the new type of solutions is finite and preserves the Z{sub 2} symmetry. The nontrivial solution corresponding to the tunneling is possible only if gravity is taken into account. The numerical solutions as well as the analytic computations using the thin-wall approximation are presented. We expect that these solutions do not have any negative mode as in the instanton solution.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multiple scattering of slow ions in a partially degenerate electron fluid

We extend former investigation to a partially degenerate electron fluid at any temperature of multiple slow ion scattering at T=0. We implement an analytic and mean-field interpolation of the target electron dielectric function between T=0 (Lindhard) and T{yields}{infinity} (Fried-Conte). A specific attention is given to multiple scattering of proton projectiles in the keV energy range, stopped in a hot-electron plasma at solid density.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Degenerate Fermi Gas of {sup 87}Sr

We report quantum degeneracy in a gas of ultracold fermionic {sup 87}Sr atoms. By evaporatively cooling a mixture of spin states in an optical dipole trap for 10.5 s, we obtain samples well into the degenerate regime with T/T{sub F}=0.26{sub -0.06}{sup +0.05}. The main signature of degeneracy is a change in the momentum distribution as measured by time-of-flight imaging, and we also observe a decrease in evaporation efficiency below T/T{sub F{approx}}0.5.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Suppression of Density Fluctuations in a Quantum Degenerate Fermi Gas

We study density profiles of an ideal Fermi gas and observe Pauli suppression of density fluctuations (atom shot noise) for cold clouds deep in the quantum degenerate regime. Strong suppression is observed for probe volumes containing more than 10 000 atoms. Measuring the level of suppression provides sensitive thermometry at low temperatures. After this method of sensitive noise measurements has been validated with an ideal Fermi gas, it can now be applied to characterize phase transitions in strongly correlated many-body systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum Degenerate Mixtures of Alkali and Alkaline-Earth-Like Atoms

We realize simultaneous quantum degeneracy in mixtures consisting of the alkali and alkaline-earth-like atoms Li and Yb. This is accomplished within an optical trap by sympathetic cooling of the fermionic isotope {sup 6}Li with evaporatively cooled bosonic {sup 174}Yb and, separately, fermionic {sup 173}Yb. Using cross-thermalization studies, we also measure the elastic s-wave scattering lengths of both Li-Yb combinations, |a{sub {sup 6}Li-{sup 174}Yb}|=1.0{+-}0.2 nm and |a{sub {sup 6}Li-{sup 173}Yb}|=0.9{+-}0.2 nm. The equality of these lengths is found to be consistent with mass-scaling analysis. The quantum degenerate mixtures of Li and Yb, as realized here, can be the basis for creation of ultracold molecules with electron spin degrees of freedom, studies of novel Efimov trimers, and impurity probes of superfluid systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Continuum Lowering and Fermi-Surface Rising in Strongly Coupled and Degenerate Plasmas

Here, continuum lowering is a well-known and important physics concept that describes the ionization potential depression (IPD) in plasmas caused by thermal-/pressure-induced ionization of outer-shell electrons. The existing IPD models are often used to characterize plasma conditions and to gauge opacity calculations. Recent precision measurements have revealed deficits in our understanding of continuum lowering in dense hot plasmas. However, these investigations have so far been limited to IPD in strongly coupled but nondegenerate plasmas. Here, we report a first-principles study of the K-edge shifting in both strongly coupled and fully degenerate carbon plasmas, with quantum molecular dynamics (QMD) calculations based on the all-electron density-functional theory (DFT). The resulted K-edge shifting versus plasma density, as a probe to the continuum lowering and the Fermi-surface rising, is found to be significantly different from predictions of existing IPD models. In contrast, a simple model of “single atom in box” (SAIB), developed in this work, accurately predicts K-edge locations as what ab-initio calculations provide.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Search for Nearly Mass-Degenerate Higgsinos Using Low-Momentum Mildly Displaced Tracks in 𝑝⁢𝑝 Collisions at $\sqrt{s}$ = 13 TeV with the ATLAS Detector

Higgsinos with masses near the electroweak scale can solve the hierarchy problem and provide a dark matter candidate, while detecting them at the LHC remains challenging if their mass splitting is 𝒪⁡(1 GeV). This Letter presents a novel search for nearly mass-degenerate Higgsinos in events with an energetic jet, missing transverse momentum, and a low-momentum track with a significant transverse impact parameter using 140 fb −1 of proton-proton collision data at $\sqrt{s}$ = 13 TeV collected by the ATLAS experiment. For the first time since LEP, a range of mass splittings between the lightest charged and neutral Higgsinos from 0.3 to 0.9 GeV is excluded at 95% confidence level, with a maximum reach of approximately 170 GeV in the Higgsino mass.

Hadron colliders↗

Colloquium: Nonlinear collective interactions in quantum plasmas with degenerate electron fluids

The current understanding of some important nonlinear collective processes in quantum plasmas with degenerate electrons is presented. After reviewing the basic properties of quantum plasmas, model equations (e.g., the quantum hydrodynamic and effective nonlinear Schroedinger-Poisson equations) are presented that describe collective nonlinear phenomena at nanoscales. The effects of the electron degeneracy arise due to Heisenberg's uncertainty principle and Pauli's exclusion principle for overlapping electron wave functions that result in tunneling of electrons and the electron degeneracy pressure. Since electrons are Fermions (spin-1/2 quantum particles), there also appears an electron spin current and a spin force acting on electrons due to the Bohr magnetization. The quantum effects produce new aspects of electrostatic (ES) and electromagnetic (EM) waves in a quantum plasma that are summarized in here. Furthermore, nonlinear features of ES ion waves and electron plasma oscillations are discussed, as well as the trapping of intense EM waves in quantum electron-density cavities. Specifically, simulation studies of the coupled nonlinear Schroedinger and Poisson equations reveal the formation and dynamics of localized ES structures at nanoscales in a quantum plasma. The effect of an external magnetic field on the plasma wave spectra and develop quantum magnetohydrodynamic equations are also discussed. The results are useful for understanding numerous collective phenomena in quantum plasmas, such as those in compact astrophysical objects (e.g., the cores of white dwarf stars and giant planets), as well as in plasma-assisted nanotechnology (e.g., quantum diodes, quantum free-electron lasers, nanophotonics and nanoplasmonics, metallic nanostructures, thin metal films, semiconductor quantum wells, and quantum dots, etc.), and in the next generation of intense laser-solid density plasma interaction experiments relevant for fast ignition in inertial confinement fusion schemes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Systemic clearance of p16 INK4a -positive senescent cells mitigates age-associated intervertebral disc degeneration

RATIONALE:Age-related changes in the intervertebral discs are the predominant contributors to back pain, a common physical and functional impairment experienced by older persons. Cellular senescence, a process wherein cells undergo growth arrest and chronically secrete numerous inflammatory molecules and proteases, has been reported to cause decline in the health and function of multiple tissues with age. Although senescent cells have been reported to increase in intervertebral degeneration (IDD), it is not known whether they are causative in age-related IDD. OBJECTIVE:The study aimed to elucidate whether a causal relationship exists between cellular senescence and age-related IDD. METHODS AND RESULTS:To examine the impact of senescent cells on age-associated IDD, we used p16-3MR transgenic mice, which enables the selective removal of p16 INK4a -positive senescent cells by the drug ganciclovir. Disc cellularity, aggrecan content and fragmentation alongside expression of inflammatory cytokine (IL-6) and matrix proteases (ADAMTS4 and MMP13) in discs of p16-3MR mice treated with GCV and untreated controls were assessed. In aged mice, reducing the per cent of senescent cells decreased disc aggrecan proteolytic degradation and increased overall proteoglycan matrix content along with improved histological disc features. Additionally, reduction of senescent cells lowered the levels of MMP13, which is purported to promote disc degenerative changes during aging. CONCLUSIONS:The findings of this study suggest that systemic reduction in the number of senescent cells ameliorates multiple age-associated changes within the disc tissue. Cellular senescence could therefore serve as a therapeutic target to restore the health of disc tissue that deteriorates with age.

60 APPLIED LIFE SCIENCES↗

Degeneration of Biogenic Superparamagnetic Magnetite

ABSTRACT. Magnetite crystals precipitated as a consequence of Fe(III) reduction by Shewanella algae BrY after 265 hours incubation and 5-year storage were investigated with transmission electron microscopy, M ssbauer spectroscopy and X-ray diffraction. The magnetite crystals were typically superparamagnetic with an approximate size of 13 nm. The lattice constants of the 265 hour and 5-year crystals are 8.4164 and 8.3774 , respectively. The M ssbauer spectra indicated that the 265 hour magnetite had excess Fe(II) in its crystal-chemistry (Fe3+1.9901Fe2+ 1.0149O4) but the 5-year magnetite was Fe(II)-deficient in stoichiometry (Fe3+2.3875Fe2+0.4188O4). Such crystal-hemical changes may be indicative of the degeneration of superparamagnetic magnetite through the aqueous oxidization of Fe(II) anaerobically, and the concomitant oxidation of the organic phases(fatty acid methyl esters) that were present during the initial formation of the magnetite. The observation of a corona structure on the aged magnetite corroborates the oxidation of Fe(II) on the outer layers of magnetite crystals. These results suggest that there may be a possible link between the enzymatic activity of the bacteria and the stability of Fe(II)-excess magnetite, which may help explain why stable nano-magnetite grains are seldom preserved in natural environments.

Li, Dr. Yi-Liang↗

Dosimetry characterization of a multibeam radiotherapy treatment for age-related macular degeneration

Age-related macular degeneration (ARMD) is a major health problem worldwide. Advanced ARMD, which ultimately leads to profound vision loss, has dry and wet forms, which account for 20% and 80% of cases involving severe vision loss, respectively. A new device and approach for radiation treatment of ARMD has been recently developed by Oraya Therapeutics, Inc. (Newark, CA). The goal of the present study is to provide a initial dosimetry characterization of the proposed radiotherapy treatment via Monte Carlo radiation transport simulation. A 3D eye model including cornea, anterior chamber, lens, orbit, fat, sclera, choroid, retina, vitreous, macula, and optic nerve was carefully designed. The eye model was imported into the MCNPX2.5 Monte Carlo code and radiation transport simulations were undertaken to obtain absorbed doses and dose volume histograms (DVH) to targeted and nontargeted structures within the eye. Three different studies were undertaken to investigate (1) available beam angles that maximized the dose to the macula target tissue, simultaneously minimizing dose to normal tissues, (2) the energy dependency of the DVH for different x-ray energies (80, 100, and 120 kVp), and (3) the optimal focal spot size among options of 0.0, 0.4, 1.0, and 5.5 mm. All results were scaled to give 8 Gy to the macula volume, which is the current treatment requirement. Eight beam treatment angles are currently under investigation. In all eight beam angles, the source-to-target distance is 13 cm, and the polar angle of entry is 30 degree sign from the geometric axis of the eye. The azimuthal angle changes in eight increments of 45 degree sign in a clockwise fashion, such that an azimuthal angle of 0 degree sign corresponds to the 12 o'clock position when viewing the treated eye. Based on considerations of nontarget tissue avoidance, as well as facial-anatomical restrictions on beam delivery, treatment azimuthal angles between 135 degree sign and 225 degree sign would be available for this treatment system (i.e., directly upward and entering the eye from below). At beam directions approaching 225 degree sign and higher, some dose contribution to the optic nerve would result under the assumption that the optic nerve is tilted cranially above the geometric axis in a given patient, a feature not typically seen in past studies. A total treatment dose of 24 Gy would be delivered in three 8 Gy treatments at these selected azimuthal angles. Dose coefficients, defined as the macula radiation absorbed dose per unit air kerma in units of Gy/Gy, were 16% higher for 120 kVp x-ray beams in comparison to those at 80 kVp, thus requiring only 86% of the integrated tube current (mAs) for equivalent dose delivery. When 0.0, 0.4, and 1.0 mm focal spot sizes were used, the dose profiles in the macula are very similar and relatively uniform, whereas a 5.5 mm focal spot size produced a more nonuniform dose profile. The results of this study demonstrate the therapeutic promise of this device and provide important information for further design and clinical implementation for radiotherapy treatments for ARMD.

61 RADIATION PROTECTION AND DOSIMETRY↗

Investigation of a {sup 90}Sr/{sup 90}Y source for intra-ocular treatment of wet age-related macular degeneration

Purpose: The purpose of this study is to perform an extensive investigation of an approximately 2.5 mm long {sup 90}Sr/{sup 90}Y source designed for treating wet age-related macular degeneration. Methods: As part of this investigation, a NIST-traceable absorbed dose to water calibration technique was established, and a source deployment verification test was developed. The influence of treatment cannula construction tolerance on the measurements as well as the dose delivered to the patient was investigated using the Monte Carlo code MCNP5. Variation between production cannulae was quantified experimentally using a well-type ionization chamber, and additional measurements along with Monte Carlo calculations of the collimating insert used for source deployment verification were performed to validate the model. Results: Maximum variation in the integrated target dose was seen when the source was shifted laterally within the treatment cannula. For the well chamber measurements, the observed standard deviation in ionization current for a single source placed in different reference cannulae was {+-}0.3%, with a maximum observed range of less than {+-}0.5%. Clinical cannulae in the collimating insert showed an average of 17.8%{+-}0.4% of the reference signal when sources were fully deployed compared to 18.5% predicted by Monte Carlo calculations. This discrepancy has been attributed primarily to construction of the collimator since the collimation gap was observed to be approximately 0.025-0.075 mm smaller than specified. Construction tolerance of the well chamber insert as well as position tolerance of the cannula tip were both investigated, and their influence on the predicted signal was quantified. Additional measurements along with Monte Carlo based calculations of the collimating insert with polyethylene spacers added to the setup were performed to validate the Monte Carlo model. The shimmed Monte Carlo and measured data agree to within 1%, which is a magnitude difference of approximately 0.1% of the reference signal. Conclusions: This investigation confirms that the signal for an acceptably deployed source in the collimating insert is between 17.5% and 21.5% of the reference signal, as calculated using Monte Carlo models. Clinical cannulae for which the source deployment verification measurement falls outside the acceptable range should not be used to treat patients.

07 ISOTOPE AND RADIATION SOURCES↗

Stereotactic targeting and dose verification for age-related macular degeneration

Purpose: Validation of the targeting and dose delivery of the IRay low voltage age-related macular degeneration treatment system. Methods: Ten human cadaver eyes were obtained for this study and mounted in the IRay system. Using gel and vacuum, an I-Guide immobilization device was coupled to the eyes and radiochromic film was affixed to the posterior aspect of the globes. Three narrow x-ray beams were delivered through the pars plana to overlap on the predicted nominal fovea. A needle was placed through the center of the film's beam spot and into the eye to register the film and the inner retina. The process was performed three times for each of the ten eyes (30 simulated treatments; 90 individual beams). The globes were dissected to assess the targeting accuracy by measuring the distances from the needles to the fovea. The dose to the fovea was calculated from the radiochromic film. Results: X-ray targeting on the retina averaged 0.6{+-}0.4 mm from the fovea. Repeated treatments on the same eye showed a reproducibility of 0.4{+-}0.4 mm. The optic nerve was safely avoided, with the 90% isodose edge of the beam spot between 0.4 and 2.6 mm from the edge of the optic disk. Measured dose matched that prescribed. Conclusions: This study provides confidence that the IRay, with an average accuracy of 0.6 mm and a precision of 0.4 mm, can reliably treat most AMD lesions centered on the fovea. With the exception of motion, all sources of error are included.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-F-CAMPUS-T-02: Monte Carlo Evaluation of Kilovoltage Radiosurgery with AuNPs for Age Related Macular Degeneration (AMD)

Purpose: To evaluate the benefit of gold nanoparticles (AuNP) in radiosurgery of Age related Macular Degeneration (AMD) using Monte Carlo (MC) simulation. AMD disease causes vision loss due to a leaky vasculature of the endothelial cells. Radiosurgical therapy aims to destroy this vasculature while minimizing the delivered dose to healthy tissues of the eye. AuNP known to enhance local dose have been targeted to the macular choroidal endothelial cells to increase the therapeutic efficacy. Methods: Dose enhancement ratio (DER) in macula endothelial cells due to a thin layer of AuNP has been calculated by a MC radiation transport simulation. AuNP layer (10–100nm) has been placed on the bottom of the macula at 2.4cm depth in a water parallelepiped 3×3×6cm3. This layer has been modeled considering various concentrations of AuNP ranging from 5.5–200mg per gram of endothelial cell (volume 10×10×2um3). The x-ray source is 100kVp 4mm diameter beam tilted 0°-30° with respect to the lens. Results: DER in endothelial cell for AuNP concentration of 31mg/g (shown experimentally feasible) and 10–100nm sizes is about 1.8. Tilting 4mm-beam does not reduce the enhancement but allows to avoid the surrounding tissues. Dose distribution in the AuNP vicinity has a significant increase within 30um, peaked at AuNP interface. DER inside and outside of the irradiation 4mm-field are the same while the actual delivered dose is more than one order of magnitude lower outside the field. Compared to 100kVp, usage of filtered spectra with enhanced flux in the region 20keV-40keV shows further increase of DER by about 20%. Dose to the neighboring organs such as retina/optic nerve are reduced accordingly. Conclusion: The results of this MC simulation provide further confirmation of the potential to enhance DER with AuNP from previous analytical calculations. This study provides impetus to improve treatment effectiveness of AMD disease with radiotherapy.

60 APPLIED LIFE SCIENCES↗