Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DATA CONVERTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Topical Report on Water Balance Model Development and Initial Application

This topical report summarizes results from developing a generic dynamic water balance tool which can be used by coal-fired power plant operators to evaluate FGD water management strategies. EPRI is using a statistical software model created on the GoldSim platform and data from coal-fired energy plants to determine the fraction of power plant water needs that can be satisfied by electrodialysis reversal treatment and, correspondingly, the discharge volume and/or byproducts that still need to be managed. The generic model is designed to accept a number of easily obtainable process variables and generate probabilities of resultant water characteristics. The model is also constructed as a universal process flow; one that can be adjusted to accommodate most major components of an FGD blowdown handling system. The generic model is dynamic and utilizes user-inputted operational variation in water quality and quantity to best provide a probabilistic representation of potential performance outcomes. In order to account for complexities of water composition and treatment, a separate chemical modeling software is used to evaluate water chemistry and unit operation performance. The thermodynamic modeling software, OLI Studio, is employed to convert ion data from laboratory analyses into balanced molecular concentrations that are classified as dissolved and suspended solids. The dynamic water model is designed to import a total of 11 species commonly found in FGD blowdown water as molecular concentrations.Water management unit operations are used in the model and categorized by either physical unit operation blocks or chemical unit operations blocks. As the name implies, the physical water treatment blocks are unit operations that are exclusively physical changes to the system (e.g., separations and volume changes). The chemical water treatment blocks are unit operations where chemical changes occur and require the use of OLI Studio to characterize subsequent streams. Water and material balances from three unique coal-fired power plants were obtained and preliminary modeling on the dynamic water balance tool was performed using the extracted data from these power plants. These three power plants were chosen due to their unique configurations and water profiles that represented a variety of operational changes. Results from using the dynamic tool with the three plant configurations are presented and discussed in the context of the existing tool and planned future capabilities.

01 COAL, LIGNITE, AND PEAT↗

Dataset for scientific paper "Simulated plant‑mediated oxygen input has strong impacts on fine‑scale porewater biogeochemistry and weak impacts on integrated methane fluxes in coastal wetlands", a modeling study based on field observation at the tidal salt marshes of the Parker River Estuary, Massachusetts, United States

This dataset is the raw and processed data for the paper "Simulated plant ‑ mediated oxygen input has strong impacts on fine ‑ scale porewater biogeochemistry and weak impacts on integrated methane fluxes in coastal wetlands". This study investigated how plant-mediated oxygen input affects subsurface biogeochemical reactions of organic carbon degradation and the resulting methane emissions of coastal wetlands by model simulation. We used the subsurface geochemical simulator PFLOTRAN for the modeling, which produced the simulated changes in porewater chemical substances and methane emissions over 10 days under different scenarios of plant-mediated oxygen input.Specifically, this dataset contains: 1) the input files for PFLOTRAN of all simulation runs conducted in this study. Those files are with an extension of ".in", containing information of the biogeochemical reaction network (stoichiometry, reaction rate, Monod constants, etc), fluid flow rate and oxygen concentration in the fluid which together simulated the plant-mediated oxygen input, the configuration of artificial reactions that simulated the methane fluxes, etc. The PFLOTRAN input files are text files, which can be opened by NotePad, but running these input files will require proper installation of PFLOTRAN (instruction: https://documentation.pflotran.org/user_guide/how_to/installation/installation.html). 2) the raw and processed model output from PFLOTRAN of all simulation runs, and 3) the python scripts used to process the raw model output, including random allocation of root cells, converting raw data into organized formats, calculating the methane fluxes based on the model output, data visualization, etc. The raw and processed model output from PFLOTRAN are in .spydata format, which can be viewed with Python. and 3) the python scripts for data processing and analysis are programming scripts, which can be opened with Python.This modeling work, in particular the model parameterization of root density and initial conditions of porewater concentrations of biogeochemical substances, was based on field measurements at the salt marsh of the Upper Parker River Estuary, Massachusetts, United States.

54 ENVIRONMENTAL SCIENCES↗

MICROX-2 cross section library based on ENDF/B-VII

New cross section libraries of a neutron transport code MICROX-2 have been generated for advanced reactor design and fuel cycle analyses. A total of 386 nuclides were processed, including 10 thermal scattering nuclides, which are available in ENDF/B-VII release 0 nuclear data. The NJOY system and MICROR code were used to process nuclear data and convert them into MICROX-2 format. The energy group structure of the new library was optimized for both the thermal and fast neutron spectrum reactors based on Contributon and Point-wise Cross Section Driven (CPXSD) method, resulting in a total of 1173 energy groups. A series of lattice cell level benchmark calculations have been performed against both experimental measurements and Monte Carlo calculations for the effective/infinite multiplication factor and reaction rate ratios. The results of MICROX-2 calculation with the new library were consistent with those of 15 reference cases. The average errors of the infinite multiplication factor and reaction rate ratio were 0.31% {delta}k and 1.9%, respectively. The maximum error of reaction rate ratio was 8% for {sup 238}U-to-{sup 235}U fission of ZEBRA lattice against the reference calculation done by MCNP5. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

DOE Joint Genome Institute 2008 Progress Report

While initially a virtual institute, the driving force behind the creation of the DOE Joint Genome Institute in Walnut Creek, California in the Fall of 1999 was the Department of Energy's commitment to sequencing the human genome. With the publication in 2004 of a trio of manuscripts describing the finished 'DOE Human Chromosomes', the Institute successfully completed its human genome mission. In the time between the creation of the Department of Energy Joint Genome Institute (DOE JGI) and completion of the Human Genome Project, sequencing and its role in biology spread to fields extending far beyond what could be imagined when the Human Genome Project first began. Accordingly, the targets of the DOE JGI's sequencing activities changed, moving from a single human genome to the genomes of large numbers of microbes, plants, and other organisms, and the community of users of DOE JGI data similarly expanded and diversified. Transitioning into operating as a user facility, the DOE JGI modeled itself after other DOE user facilities, such as synchrotron light sources and supercomputer facilities, empowering the science of large numbers of investigators working in areas of relevance to energy and the environment. The JGI's approach to being a user facility is based on the concept that by focusing state-of-the-art sequencing and analysis capabilities on the best peer-reviewed ideas drawn from a broad community of scientists, the DOE JGI will effectively encourage creative approaches to DOE mission areas and produce important science. This clearly has occurred, only partially reflected in the fact that the DOE JGI has played a major role in more than 45 papers published in just the past three years alone in Nature and Science. The involvement of a large and engaged community of users working on important problems has helped maximize the impact of JGI science. A seismic technological change is presently underway at the JGI. The Sanger capillary-based sequencing process that dominated how sequencing was done in the last decade is being replaced by a variety of new processes and sequencing instruments. The JGI, with an increasing number of next-generation sequencers, whose throughput is 100- to 1,000-fold greater than the Sanger capillary-based sequencers, is increasingly focused in new directions on projects of scale and complexity not previously attempted. These new directions for the JGI come, in part, from the 2008 National Research Council report on the goals of the National Plant Genome Initiative as well as the 2007 National Research Council report on the New Science of Metagenomics. Both reports outline a crucial need for systematic large-scale surveys of the plant and microbial components of the biosphere as well as an increasing need for large-scale analysis capabilities to meet the challenge of converting sequence data into knowledge. The JGI is extensively discussed in both reports as vital to progress in these fields of major national interest. JGI's future plan for plants and microbes includes a systematic approach for investigation of these organisms at a scale requiring the special capabilities of the JGI to generate, manage, and analyze the datasets. JGI will generate and provide not only community access to these plant and microbial datasets, but also the tools for analyzing them. These activities will produce essential knowledge that will be needed if we are to be able to respond to the world's energy and environmental challenges. As the JGI Plant and Microbial programs advance, the JGI as a user facility is also evolving. The Institute has been highly successful in bending its technical and analytical skills to help users solve large complex problems of major importance, and that effort will continue unabated. The JGI will increasingly move from a central focus on 'one-off' user projects coming from small user communities to much larger scale projects driven by systematic and problem-focused approaches to selection of sequencing targets. Entire communities of scientists working in a particular field, such as feedstock improvement or biomass degradation, will be users of this information. Despite this new emphasis, an investigator-initiated user program will remain. This program in the future will replace small projects that increasingly can be accomplished without the involvement of JGI, with imaginative large-scale 'Grand Challenge' projects of foundational relevance to energy and the environment that require a new scale of sequencing and analysis capabilities. Close interactions with the DOE Bioenergy Research Centers, and with other DOE institutions that may follow, will also play a major role in shaping aspects of how the JGI operates as a user facility. Based on increased availability of high-throughput sequencing, the JGI will increasingly provide to users, in addition to DNA sequencing, an array of both pre- and post-sequencing value-added capabilities to accelerate their science.

09 BIOMASS FUELS↗

Exploring Physics of Ferroelectric Domain Walls in Real Time: Deep Learning Enabled Scanning Probe Microscopy

The functionality of ferroelastic domain walls in ferroelectric materials is explored in real-time via the in situ implementation of computer vision algorithms in scanning probe microscopy (SPM) experiment. The robust deep convolutional neural network (DCNN) is implemented based on a deep residual learning framework (Res) and holistically nested edge detection (Hed), and ensembled to minimize the out-of-distribution drift effects. The DCNN is implemented for real-time operations on SPM, converting the data stream into the semantically segmented image of domain walls and the corresponding uncertainty. Further the pre-defined experimental workflows perform piezoresponse spectroscopy measurement on thus discovered domain walls, and alternating high- and low-polarization dynamic (out-of-plane) ferroelastic domain walls in a PbTiO 3 (PTO) thin film and high polarization dynamic (out-of-plane) at short ferroelastic walls (compared with long ferroelastic walls) in a lead zirconate titanate (PZT) thin film is reported. This work establishes the framework for real-time DCNN analysis of data streams in scanning probe and other microscopies and highlights the role of out-of-distribution effects and strategies to ameliorate them in real time analytics.

36 MATERIALS SCIENCE↗

Direct measurement and calculation of rubber bulk modulus by piston-cylinder method using conventional mechanical testing equipment

This article describes a method to directly measure the bulk modulus of rubber using a piston-cylinder type apparatus. The function of the testing apparatus is to reliably transfer load to the water inside the vessel and allow for the accurate and continuous measurement of volumetric displacement as the contents are compressed. During the test, load is applied to a piston-cylinder containing the rubber test sample and water using a conventional mechanical testing load frame. Load and the travel of the piston are recorded by a load cell and extensometer, respectfully. A brass or stainless steel plug of the same dimensions as the test sample is tested as a control sample to isolate the compliance of the system, including the compressibility of water and compliance of the piston-cylinder. The results from this control test are used to disincorporate the compliance of the system from the sample test results. Load-linear displacement data are mathematically converted to pressure-volumetric displacement data, from which bulk modulus is calculated. The test apparatus and method are validated using the known bulk modulus of water. Finally, the bulk modulus for two similar rubbers is evaluated. The validity of the results and limitations of the device are discussed.

36 MATERIALS SCIENCE↗

Techno-economic assessment of emerging CO 2 electrolysis technologies

Recycling of waste CO 2 to bulk chemicals has a tremendous potential for the decarbonization of the chemical industry. Quantitative analysis of the prospects of this technology is hindered by the lack of flexible techno-economic assessment (TEA) models that enable evaluation of the processing costs under different deployment scenarios. In this protocol, we explain how to convert literature data into metrics useful for evaluation of the emerging electrolysis technologies, derive TEA models, and illustrate their use with a CO 2 -to-ethylene example. For complete details on the use and execution of this protocol, please refer to Barecka et al. (2021a).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Estimating the conditions for polariton condensation in organic thin-film microcavities

We examine the possibility of observing Bose condensation of a confined two-dimensional polariton gas in an organic quantum well. We deduce a suitable parameterization of a model polynomial Hamiltonian based upon the cavity geometry, the biexciton binding energy, and similar spectroscopic and structural data. By converting the sum-over-states to a semiclassical integration over D-dimensional phase space, we arrive at a principle of correspondence between ideal and non-ideal Bose gases that share a common critical exponent. Using our results, we can calculate the properties for a model cavity containing an anthracene thin film.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Metal-oxide-semiconductor capacitors and Schottky diodes studied with scanning microwave microscopy at 18 GHz

We measured the DC and RF impedance characteristics of micrometric metal-oxide-semiconductor (MOS) capacitors and Schottky diodes using scanning microwave microscopy (SMM). The SMM consisting of an atomic force microscopy (AFM) interfaced with a vector network analyser (VNA) was used to measure the reflection S11 coefficient of the metallic MOS and Schottky contact pads at 18 GHz as a function of the tip bias voltage. By controlling the SMM biasing conditions, the AFM tip was used to bias the Schottky contacts between reverse and forward mode. In reverse bias direction, the Schottky contacts showed mostly a change in the imaginary part of the admittance while in forward bias direction the change was mostly in the real part of the admittance. Reference MOS capacitors which are next to the Schottky diodes on the same sample were used to calibrate the SMM S11 data and convert it into capacitance values. Calibrated capacitance between 1–10 fF and 1/C{sup 2} spectroscopy curves were acquired on the different Schottky diodes as a function of the DC bias voltage following a linear behavior. Additionally, measurements were done directly with the AFM-tip in contact with the silicon substrate forming a nanoscale Schottky contact. Similar capacitance-voltage curves were obtained but with smaller values (30–300 aF) due to the corresponding smaller AFM-tip diameter. Calibrated capacitance images of both the MOS and Schottky contacts were acquired with nanoscale resolution at different tip-bias voltages.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A method for determining average damage depth of sawn crystalline silicon wafers

The depth of surface damage (or simply, damage) in crystalline silicon wafers, caused by wire sawing of ingots, is determined by performing a series of minority carrier lifetime (MCLT) measurements. Samples are sequentially etched to remove thin layers from each surface and MCLT is measured after each etch step. The thickness-removed (δt) at which the lifetime reaches a peak value corresponds to the damage depth. This technique also allows the damage to be quantified in terms of effective surface recombination velocity (S eff ). To accomplish this, the MCLT data are converted into an S eff vs δt plot, which represents a quantitative distribution of the degree of damage within the surface layer. We describe a wafer preparation procedure to attain reproducible etching and MCLT measurement results. We also describe important characteristics of an etchant used for controllably removing thin layers from the wafer surfaces. Lastly, some typical results showing changes in the MCLT vs δt plots for different cutting parameters are given.

14 SOLAR ENERGY↗

Upgrade of the helically symmetric experiment Thomson scattering diagnostic suite

The Helically Symmetric eXperiment (HSX) Thomson Scattering (TS) diagnostic is being upgraded to decrease uncertainty in electron temperature and density measurements. Upgrades to the HSX TS diagnostic will consist of a novel redesign of polychromator electronics and digitization of the TS output signal. Here, we also present a study of the benefits of an additional spectral channel that will sample the red-shifted band of the scattered spectrum. In conclusion, to maximize system bandwidth (BW) and gain, while minimizing noise, the existing low-BW polychromator electronics on HSX will be replaced by high-BW, high gain circuitry designed in-house.

47 OTHER INSTRUMENTATION↗

The dwarfs beyond: The stellar-to-halo mass relation for a new sample of intermediate redshift low-mass galaxies

A number of recent challenges to the standard ΛCDM paradigm relate to discrepancies that arise in comparing the abundance and kinematics of local dwarf galaxies with the predictions of numerical simulations. Such arguments rely heavily on the assumption that the Local Volume's dwarf and satellite galaxies form a representative distribution in terms of their stellar-to-halo mass ratios. To address this question, we present new, deep spectroscopy using DEIMOS on Keck for 82 low-mass (10{sup 7}-10{sup 9} M {sub ☉}), star-forming galaxies at intermediate redshift (0.2 < z < 1). For 50% of these we are able to determine resolved rotation curves using nebular emission lines and thereby construct the stellar mass Tully-Fisher relation to masses as low as 10{sup 7} M {sub ☉}. Using scaling relations determined from weak lensing data, we convert this to a stellar-to-halo mass relation for comparison with abundance matching predictions. We find a discrepancy between our observations and the predictions from abundance matching in the sense that we observe 3-12 times more stellar mass at a given halo mass. We suggest possible reasons for this discrepancy, as well as improved tests for the future.

79 ASTRONOMY AND ASTROPHYSICS↗

Resolving astrophysical uncertainties in dark matter direct detection

We study the impact of the assumed velocity distribution of galactic dark matter particles on the interpretation of results from nuclear recoil detectors. By converting experimental data to variables that make the astrophysical unknowns explicit, different experiments can be compared without implicit assumptions concerning the dark matter halo. We extend this framework to include the annual modulation signal, as well as multiple target elements. Recent results from DAMA, CoGeNT and CRESST-II can be brought into agreement if the velocity distribution is very anisotropic and thus allows a large modulation fraction. However constraints from CDMS and XENON cannot be evaded by appealing to such astrophysical uncertainties alone.

79 ASTRONOMY AND ASTROPHYSICS↗

Neutron capture cross sections of {sup 184}W and {sup 186}W

The neutron capture cross sections of {sup 184}W and {sup 186}W have been determined by means of the activation technique. The measurements were carried out at the Karlsruhe 3.75-MV Van de Graaff accelerator using the {sup 7}Li(p,n){sup 7}Be reaction for neutron production. Samples of natural composition were irradiated in a quasistellar neutron spectrum for a thermal energy of kT=25 keV. Systematic uncertainties were investigated by variation of the experimental parameters in repeated activations. The induced activities were counted with HPGe detectors via the strongest {gamma}-ray lines in the decay of the respective product nuclei. The measured data were converted into Maxwellian averaged cross sections at kT=30 keV, yielding 221{+-}12 mb and 231{+-}11 mb for {sup 184}W and {sup 186}W, respectively. Together with the result of a previously reported measurement on {sup 180}W, the present values can be used to improve the cross-section trend with neutron number, which is important for extrapolation into the regions of unstable isotopes. These results are of interest for stellar and explosive nucleosynthesis in nuclear astrophysics as well as for technological applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigating the accuracy of microstereotactic-body-radiotherapy utilizing anatomically accurate 3D printed rodent-morphic dosimeters

Purpose: Sophisticated small animal irradiators, incorporating cone-beam-CT image-guidance, have recently been developed which enable exploration of the efficacy of advanced radiation treatments in the preclinical setting. Microstereotactic-body-radiation-therapy (microSBRT) is one technique of interest, utilizing field sizes in the range of 1–15 mm. Verification of the accuracy of microSBRT treatment delivery is challenging due to the lack of available methods to comprehensively measure dose distributions in representative phantoms with sufficiently high spatial resolution and in 3 dimensions (3D). This work introduces a potential solution in the form of anatomically accurate rodent-morphic 3D dosimeters compatible with ultrahigh resolution (0.3 mm{sup 3}) optical computed tomography (optical-CT) dose read-out. Methods: Rodent-morphic dosimeters were produced by 3D-printing molds of rodent anatomy directly from contours defined on x-ray CT data sets of rats and mice, and using these molds to create tissue-equivalent radiochromic 3D dosimeters from Presage. Anatomically accurate spines were incorporated into some dosimeters, by first 3D printing the spine mold, then forming a high-Z bone equivalent spine insert. This spine insert was then set inside the tissue equivalent body mold. The high-Z spinal insert enabled representative cone-beam CT IGRT targeting. On irradiation, a linear radiochromic change in optical-density occurs in the dosimeter, which is proportional to absorbed dose, and was read out using optical-CT in high-resolution (0.5 mm isotropic voxels). Optical-CT data were converted to absolute dose in two ways: (i) using a calibration curve derived from other Presage dosimeters from the same batch, and (ii) by independent measurement of calibrated dose at a point using a novel detector comprised of a yttrium oxide based nanocrystalline scintillator, with a submillimeter active length. A microSBRT spinal treatment was delivered consisting of a 180° continuous arc at 225 kVp with a 20 × 10 mm field size. Dose response was evaluated using both the Presage/optical-CT 3D dosimetry system described above, and independent verification in select planes using EBT2 radiochromic film placed inside rodent-morphic dosimeters that had been sectioned in half. Results: Rodent-morphic 3D dosimeters were successfully produced from Presage radiochromic material by utilizing 3D printed molds of rat CT contours. The dosimeters were found to be compatible with optical-CT dose readout in high-resolution 3D (0.5 mm isotropic voxels) with minimal artifacts or noise. Cone-beam CT image guidance was possible with these dosimeters due to sufficient contrast between high-Z spinal inserts and tissue equivalent Presage material (CNR ∼10 on CBCT images). Dose at isocenter measured with optical-CT was found to agree with nanoscintillator measurement to within 2.8%. Maximum dose in line profiles taken through Presage and film dose slices agreed within 3%, with FWHM measurements through each profile found to agree within 2%. Conclusions: This work demonstrates the feasibility of using 3D printing technology to make anatomically accurate Presage rodent-morphic dosimeters incorporating spinal-mimicking inserts. High quality optical-CT 3D dosimetry is feasible on these dosimeters, despite the irregular surfaces and implanted inserts. The ability to measure dose distributions in anatomically accurate phantoms represents a powerful useful additional verification tool for preclinical microSBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cardiac motion correction based on partial angle reconstructed images in x-ray CT

Purpose: Cardiac x-ray CT imaging is still challenging due to heart motion, which cannot be ignored even with the current rotation speed of the equipment. In response, many algorithms have been developed to compensate remaining motion artifacts by estimating the motion using projection data or reconstructed images. In these algorithms, accurate motion estimation is critical to the compensated image quality. In addition, since the scan range is directly related to the radiation dose, it is preferable to minimize the scan range in motion estimation. In this paper, the authors propose a novel motion estimation and compensation algorithm using a sinogram with a rotation angle of less than 360°. The algorithm estimates the motion of the whole heart area using two opposite 3D partial angle reconstructed (PAR) images and compensates the motion in the reconstruction process. Methods: A CT system scans the thoracic area including the heart over an angular range of 180° + α + β, where α and β denote the detector fan angle and an additional partial angle, respectively. The obtained cone-beam projection data are converted into cone-parallel geometry via row-wise fan-to-parallel rebinning. Two conjugate 3D PAR images, whose center projection angles are separated by 180°, are then reconstructed with an angular range of β, which is considerably smaller than a short scan range of 180° + α. Although these images include limited view angle artifacts that disturb accurate motion estimation, they have considerably better temporal resolution than a short scan image. Hence, after preprocessing these artifacts, the authors estimate a motion model during a half rotation for a whole field of view via nonrigid registration between the images. Finally, motion-compensated image reconstruction is performed at a target phase by incorporating the estimated motion model. The target phase is selected as that corresponding to a view angle that is orthogonal to the center view angles of two conjugate PAR images. To evaluate the proposed algorithm, digital XCAT and physical dynamic cardiac phantom datasets are used. The XCAT phantom datasets were generated with heart rates of 70 and 100 bpm, respectively, by assuming a system rotation time of 300 ms. A physical dynamic cardiac phantom was scanned using a slowly rotating XCT system so that the effective heart rate will be 70 bpm for a system rotation speed of 300 ms. Results: In the XCAT phantom experiment, motion-compensated 3D images obtained from the proposed algorithm show coronary arteries with fewer motion artifacts for all phases. Moreover, object boundaries contaminated by motion are well restored. Even though object positions and boundary shapes are still somewhat different from the ground truth in some cases, the authors see that visibilities of coronary arteries are improved noticeably and motion artifacts are reduced considerably. The physical phantom study also shows that the visual quality of motion-compensated images is greatly improved. Conclusions: The authors propose a novel PAR image-based cardiac motion estimation and compensation algorithm. The algorithm requires an angular scan range of less than 360°. The excellent performance of the proposed algorithm is illustrated by using digital XCAT and physical dynamic cardiac phantom datasets.

60 APPLIED LIFE SCIENCES↗

SU-E-J-72: Dosimetric Study of Cone-Beam CT-Based Radiation Treatment Planning Using a Patient-Specific Stepwise CT-Density Table

Purpose: To assess dose calculation accuracy of cone-beam CT (CBCT) based treatment plans using a patient-specific stepwise CT-density conversion table in comparison to conventional CT-based treatment plans. Methods: Unlike CT-based treatment planning which use fixed CT-density table, this study used patient-specific CT-density table to minimize the errors in reconstructed mass densities due to the effects of CBCT Hounsfield unit (HU) uncertainties. The patient-specific CT-density table was a stepwise function which maps HUs to only 6 classes of materials with different mass densities: air (0.00121g/cm3), lung (0.26g/cm3), adipose (0.95g/cm3), tissue (1.05 g/cm3), cartilage/bone (1.6g/cm3), and other (3g/cm3). HU thresholds to define different materials were adjusted for each CBCT via best match with the known tissue types in these images. Dose distributions were compared between CT-based plans and CBCT-based plans (IMRT/VMAT) for four types of treatment sites: head and neck (HN), lung, pancreas, and pelvis. For dosimetric comparison, PTV mean dose in both plans were compared. A gamma analysis was also performed to directly compare dosimetry in the two plans. Results: Compared to CT-based plans, the differences for PTV mean dose were 0.1% for pelvis, 1.1% for pancreas, 1.8% for lung, and −2.5% for HN in CBCT-based plans. The gamma passing rate was 99.8% for pelvis, 99.6% for pancreas, and 99.3% for lung with 3%/3mm criteria, and 80.5% for head and neck with 5%/3mm criteria. Different dosimetry accuracy level was observed: 1% for pelvis, 3% for lung and pancreas, and 5% for head and neck. Conclusion: By converting CBCT data to 6 classes of materials for dose calculation, 3% of dose calculation accuracy can be achieved for anatomical sites studied here, except HN which had a 5% accuracy. CBCT-based treatment planning using a patient-specific stepwise CT-density table can facilitate the evaluation of dosimetry changes resulting from variation in patient anatomy.

60 APPLIED LIFE SCIENCES↗