Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CsY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Synthesis, structure, and magnetic and electronic properties of Cs{sub 2}Hg{sub 2}USe{sub 5}

The compound Cs{sub 2}Hg{sub 2}USe{sub 5} was obtained from the solid-state reaction of U, HgSe, Cs{sub 2}Se{sub 3}, Se, and CsI at 1123 K. This material crystallizes in a new structure type in space group P2/n of the monoclinic system with a cell of dimensions a=10.276(6) A, b=4.299(2) A, c=15.432(9) A, beta=101.857(6) A, and V=667.2(6) A{sup 3}. The structure contains {sub i}nfinity{sup 2}[Hg{sub 2}USe{sub 5}] layers separated by Cs atoms. Within the layers are distorted HgSe{sub 4} tetrahedra and regular USe{sub 6} octahedra. In the temperature range of 25-300 K Cs{sub 2}Hg{sub 2}USe{sub 5} displays Curie-Weiss paramagnetism with mu{sub eff}=3.71(2) mu{sub B}. The compound exhibits semiconducting behavior in the [010] direction; the conductivity at 298 K is 3x10{sup -3} S/cm. Formal oxidation states of Cs/Hg/U/Se may be assigned as +1/+2/+4/- 2, respectively. - Graphical abstract: View of the crystal structure of Cs{sub 2}Hg{sub 2}USe{sub 5}.

36 MATERIALS SCIENCE↗

Assessment of the grindability of robocast silicon carbide

The demand for high-performance lightweight optics has driven interest in silicon carbide (SiC) due to its exceptional thermal stability, hardness, and strength-to-weight ratio. This study investigates the potential of robocasting, an additive manufacturing process, as a viable method for producing lightweighted SiC components for optical applications. Four samples with varied starting powder phases (α and β) and sintering conditions were fabricated and evaluated. Post-sintering surface and form were assessed using coherence scanning interferometry (CSI) and coordinate measuring machine (CMM) techniques. A three-stage grinding process was applied to each sample, with surface roughness assessed at each stage. Results demonstrate that samples with predominantly α-phase SiC and smaller particle sizes achieved superior surface finish, particularly sample D2-α-2135 °C, which displayed the lowest post-grinding Sq value of 0.178 µm. The analysis also indicated no significant print-through effect from the lightweighting structure, or print artifacts, at this stage of grinding. However, β-phase samples showed poorer grindability, increased surface roughness, and pitting. These findings suggest that phase composition and particle size are critical for achieving the desired surface quality in robocast SiC optics. Future work will incorporate additional samples and finer grinding wheels to refine surface quality further, supporting the development of SiC for high-precision optical applications.

Barrett, Taylor [ORNL]↗

Upgrade of the proximity focusing RICH at Jlab

The Hall A RICH at Jefferson Lab is undergoing an upgrade to adapt to the higher momentum kinematics of the neutron spin structure Transversity experiments planned to run in 2008. The JLab RICH is a proximity focusing detector using liquid C6F14 as Cherenkov radiator, a thin layer of CsI as photon converter, evaporated on segmented pad panels of a proportional chamber. The original RICH had a superior hadron identification up to 2 GeV/c with pion/kaon rejection at the level of 1:1000 at ~ similar90% intrinsic efficiency. The upgrade will extend this performance above 2.4 GeV/c by means of a larger photon detector (a multiwire-multipad proportional chamber) and a longer proximity gap which will improve the photon detection geometrical efficiency and the angular resolution, respectively.

43 PARTICLE ACCELERATORS↗

Development of a pepper pot emittance probe and its application for ECR ion beam studies.

A pepper pot-scintillator screen system has been developed and used to measure the emittance of DC ion beams extracted from a high-intensity permanent magnet ECR ion source. The system includes a fast beam shutter with a minimum dwell time of 18 ms to reduce the degradation of the CsI(Tl) scintillator by DC ion beam irradiation and a CCD camera with a variable shutter speed in the range of 1 {micro}s-65 s. On-line emittance measurements are performed by an application code developed on a LabVIEW platform. The sensitivity of the device is sufficient to measure the emittance of DC ion beams with current densities down to about 100 nA/cm{sup 2}. The emittance of all ion species extracted from the ECR ion source and post-accelerated to an energy of 75-90 keV/charge have been measured downstream of the LEBT. As the mass-to-charge ratio of ion species increases, the normalized RMS emittances in both transverse phase planes decrease from 0.5-1.0 {pi} mm mrad for light ions to 0.05-0.09 {pi} mm mrad for highly charged {sup 209}Bi ions. The dependence of the emittance on ion's mass-to-charge ratio follows very well the dependence expected from beam rotation induced by decreasing ECR axial magnetic field. The measured emittance values cannot be explained by only ion beam rotation for all ion species and the contribution to emittance of ion temperature in plasma, non-linear electric fields and non-linear space charge is comparable or even higher than the contribution of ion beam rotation.

74 ATOMIC AND MOLECULAR PHYSICS↗

Design, construction, operation and performance of a Hadron Blind Detector for the PHENIX experiment

A Hadron Blind Detector (HBD) has been developed, constructed and successfully operated within the PHENIX detector at RHIC. The HBD is a Cherenkov detector operated with pure CF{sub 4}. It has a 50 cm long radiator directly coupled in a windowless configuration to a readout element consisting of a triple GEM stack, with a CsI photocathode evaporated on the top surface of the top GEM and pad readout at the bottom of the stack. This paper gives a comprehensive account of the construction, operation and in-beam performance of the detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and status of the Mu2e electromagnetic calorimeter

Here, the Mu2e experiment at Fermilab aims at measuring the neutrinoless conversion of a negative muon into an electron and reach a single event sensitivity of 2.5×10 –17 after three years of data taking. The monoenergetic electron produced in the final state, is detected by a high precision tracker and a crystal calorimeter, all embedded in a large superconducting solenoid (SD) surrounded by a cosmic ray veto system. The calorimeter is complementary to the tracker, allowing an independent trigger and powerful particle identification, while seeding the track reconstruction and contributing to remove background tracks mimicking the signal. In order to match these requirements, the calorimeter should have an energy resolution of O(5)% and a time resolution better than 500 ps at 100 MeV. The baseline solution is a calorimeter composed of two disks of BaF 2 crystals read by UV extended, solar blind, Avalanche Photodiode (APDs), which are under development from a JPL, Caltech, RMD consortium. In this paper, the calorimeter design, the R&D; studies carried out so far and the status of engineering are described. A backup alternative setup consisting of a pure CsI crystal matrix read by UV extended Hamamatsu MPPC's is also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-cost, multi-mode detector solutions

Low-cost radiation detectors capable of providing efficient gamma-ray and neutron detection are essential in passive nuclear monitoring systems such as radiation portal monitors (RPMs) and detection of Special Nuclear Materials (SNM) through Active Interrogation (AI). Here, three low-cost detector solutions are discussed—(1) Large-area polystyrene-based plastic scintillators for AI (2) Pulse Shape Discrimination (PSD) capable plastic scintillators doped with heavy-metals for imparting gamma-ray spectroscopy (3) Composite detector technology based on inorganic scintillator submerged into the plastic scintillator, for detection of thermal and fast neutrons in addition to gamma-ray spectroscopy. Composite detectors using inorganic component such as Cs 2 LiYCl 6 (CLYC), Cs 2 LiLaBr x Cl 6-x (CLLBC), or CsI:Tl have been developed up to 4” sizes. Neutron and gamma efficiencies are compared for samples with different inorganic loading.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mu2e Calorimeter Readout System

The Mu2e electromagnetic calorimeter is made of two disks of un-doped parallelepiped CsI crystals readout by SiPM. There are 674 crystals in one disk and each crystal is readout by an array of two SiPM. The readout electronics is composed of two types of modules: (1) the front-end module hosts the shaping amplifier and the high voltage linear regulator; since one front-end module is interfaced to one SiPM, a total of 2696 modules are needed for the entire calorimeter; (2) a waveform digitizer provides a further level of amplification and digitizes the SiPM signal at the sampling frequency of 200MHz with 12-bits ADC resolution; since one board digitizes the data received from 20 SiPMs, a total of 136 boards are needed. The readout system operational conditions are hostile: ionization dose of 20krads , neutron flux of 10 12 n(1MeVeq)/cm 2 , magnetic field of 1T and in vacuum level of 10 -4 Torr . A description of the readout system and qualification tests is reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of the muon flux produced by 10.6 GeV electrons in a beam dump

This paper proposes the results of an experiment to assess the muon flux produced by the interaction of a 10.6 GeV electron beam with the Hall-A beam dump at Jefferson Lab (JLab). The goal was to benchmark Monte Carlo simulations that are an essential tool for estimating beam-related backgrounds in beam-dump experiments aimed at searching for rare events, such as the Beam Dump eXperiment (BDX) planned at JLab. Beam-produced muons were measured with a CsI(Tl) crystal sandwiched between a set of segmented plastic scintillators placed at two different distances from the dump: 25.7 m and 28.8 m. At each location the muon flux was sampled at different vertical positions with respect to the beam height. Data have been compared with detailed Monte Carlo simulations using FLUKA for the muon production in the dump and propagation to the detector, and GEANT4 to simulate the detector response. The good agreement between data and simulations, within the uncertainties of the soil composition and density, exhibit the validity of our simulation tools to predict the beam-related muon background in electron beam-dump experiments at ~10 GeV.

47 OTHER INSTRUMENTATION↗

The Mu2e experiment — Searching for charged lepton flavor violation

The Mu2e experiment will search for a Standard Model violating rate of neutrinoless conversion of a muon into an electron in the presence of an aluminum nucleus. Observation of this charged lepton flavor violating process would be an unambiguous sign of new physics. Mu2e will improve upon previous searches for this process by four orders of magnitude. This requires the world’s highest-intensity muon beam, a detector system capable of efficiently reconstructing the 105 MeV/c conversion electron signal, and minimizing sensitivity to background events. A pulsed 8 GeV proton beam strikes a target, producing pions that decay into muons. Beam outside the pulse must be suppressed to < 1 0 – 10 to reduce beam-related backgrounds. The muon beam is guided from the production target along the transport system and onto the aluminum stopping target. Conversion electrons leave the stopping target and propagate inside a solenoidal magnetic field to the tracker and electromagnetic calorimeter. The tracker is a system of straw tube panels filled with Ar/CO 2 at 1 atm that tracks particles inside of a solenoidal B-field and measures their momenta with ~ 100 keV/c resolution to resolve signal events from decay-in-orbit backgrounds. The CsI calorimeter provides E / p and is used to seed the track reconstruction algorithm with σ E / E ~ 10 % and σ t < 500 ps . Additionally, a novel cosmic ray veto with greater than 99.99% efficiency brings the expected number of background events to fewer than one over three years of running. Finally, to normalize the experiment, the stopping target monitor measures the rate of capture photons from muons incident on the stopping target by using a system of high-purity germanium and lanthanum bromide scintillators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sub-25 ps timing measurements with 10 × 10 cm 2 PICOSEC Micromegas detectors

The PICOSEC Micromegas detector is a precise timing gaseous detector based on a Cherenkov radiator coupled to a semi-transparent photocathode and a Micromegas amplifying structure. First single-pad prototypes demonstrated a time resolution below σ = 25 ps, however, to make the concept appropriate to physics applications, several developments are required. The objective of this work was to achieve an equivalent time resolution for a 10 × 10 cm 2 area PICOSEC Micromegas detector. The prototype was designed, produced and tested in the laboratory and successfully operated with a 80 GeV/c muon beam. Preliminary results for this device equipped with a CsI photocathode demonstrated a time resolution below σ = 25 ps for all measured pads. The time resolution was reduced to be below σ = 18 ps by decreasing the drift gap to 180 μm and using dedicated RF amplifier cards as new electronics. The excellent timing performance of the single-channel proof of concept was not only transferred to the 100-channel prototype, but even improved, making the PICOSEC Micromegas detector more suitable for large-area experiments in need of detectors with high time resolutions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High event rate analysis technique for the dual-axis duo-lateral position-sensitive silicon detectors of FAUST

The dual-axis duo-lateral (DADL) position-sensitive silicon detector was developed to obtain precise position and energy information for detected charged particles. The Forward Array Using Silicon Technology (FAUST) is currently equipped with 68 DADL detectors backed by CsI(Tl) scintillators for the study of charged particle correlations in heavy-ion collisions where precise position and energy information is essential. When conventional signal processing electronics were used for the DADL detectors, a position dependence of the measured energy as well as distortions in the calculated particle positions were observed. In previous work, waveforms from the detector after preamplification were studied to better understand the features that give rise to these distortions; therein, a waveform analysis technique was developed to improve the energy resolution and linearity in position reconstruction. However, the reading and writing of waveforms for an entire detector array limits data collection rates and adds significant burden in data storage and analysis speed. In this work, the integrators of a Struck SIS3316 ADC were utilized to process 228 Th source data to develop and optimize a new analysis method that captures the benefits of the waveform analysis technique while circumventing the waveform writing requirement. This integrator method – capable of 59 keV (FWHM) energy resolution – was used in the collection of 35 MeV/nucleon 28 Si + 12 C collision data using FAUST to investigate exotic decays of highly excited highly deformed nuclei. In this data, a position resolution of 0.4 mm (FWHM) was obtained for 25 MeV α-particles; for α-particles near this energy that originate from 8 Be ground state decays, a 8 Be ground state width of 30 keV (FWHM) was obtained. The impact of the energy-dependent DADL position resolution emergent from electronic noise on the quality of excited state measurement was modeled and compared to the experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single channel PICOSEC Micromegas detector with improved time resolution

This paper presents design guidelines and the experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. The design encompasses the detector board, vessel, auxiliary mechanical parts, and electrical connectivity for high voltage (HV) and signals, focusing on improving the stability, reducing noise, and ensuring signal integrity to optimize timing performance. A notable feature is the simple and fast reassembly procedure, facilitating quick replacement of the detector internal components that allows for an efficient measurement strategy involving different detector components. The paper also examines the influence of parasitic capacitance and inductance on the output signal integrity. To validate the design, a prototype assembly and three interchangeable detector boards with varying readout pad diameters were manufactured. Detectors were initially tested in the laboratory. Finally, the timing performance of the detectors with different pad sizes was verified using 150 GeV muons. Notably, a record time resolution for a PICOSEC Micromegas detector technology with a CsI photocathode of 12.5 ± 0.8 ps was achieved for a detector with 10 mm diameter readout pad size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of the Mu2e experiment

The Mu2e experiment at Fermilab searches for the coherent, neutrino-less conversion of a μ − to e − in the Coulomb field of Al nuclei, that represents one of the cleanest Charged Lepton Flavor Violating (CLFV) processes for exploring Beyond the Standard Model (BSM) physics. Mu2e aims to improve previous sensitivity by four orders of magnitude, with a distinctive signature provided by identifying mono-energetic electrons with energy slightly below the muon rest mass. To reach this goal, the experiment will use the highest intensity pulsed muon beam in the world, with up to 6 × 1 0 9 stopped muons/sec. This is achieved using the Fermilab proton beam and the design and realization of a unique 25 m long superconducting solenoidal system. The high beam intensity relies upon minimizing beam losses in the slow extraction region, indicating an opportunity of using bent crystals for shadowing. A high-resolution straw tracker and a fast CsI crystal calorimeter identify the conversion electron. Both detectors are inserted behind the Stopping Target in the last solenoid section. A Cosmic Ray Veto covers a large part of the solenoids to suppress background produced by cosmic rays. In this paper, we report the details of the experimental layout, the construction status of the magnetic system and detectors, and a short description of the simulation and realization of the bent crystals. Performing crystal channeling in front of the first slow extraction septa will allow beam shadowing and largely reduce beam losses. •Charge Lepton Flavor Violation processes: μ − → e − conversion.•Large Superconducting Solenoid system.•High-Intensity beams•High precision detectors.•Crystal channeling.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Response of Materials to Single Ion Events

Response of materials to single radiation events is fundamental to research and many technological applications that involve energetic particles. Ion-solid interactions lead to energy loss of ions, production of electron-hole pairs, and light emission from excitation-induced luminescence. Employing a unique time-of-flight system, material response to single ion irradiation has been utilized to measure electronic energy loss, and to evaluate materials performance for radiation detection. Measurements of electronic energy loss of single ions in a thin ZrO2 foil over a continuous energy range exhibit good agreement with SRIM predictions for He and Be ions. For O and F ions, slight over- and under-estimation of SRIM prediction is evident at energies around 250 (near the stopping maximum) and above 800 keV/nucleon, respectively. For a Si semiconductor detector, its response to single ion irradiation shows that pulse height defect is clear for elements heavier than Si, and nonlinear energy response is significant for all elements at energies below ~ 150 keV/nucleon. For a single crystal CsI:Tl scintillator, the response to H ion events is used to determine relative light yield and absolute energy resolution over a wide energy region, where energy resolution of ~ 5.3% is achieved at 2 MeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TexAT detector upgrade for 14 O($α$, $p$) 17 F cross section measurement

A direct cross-section measurement of the 14 O($α$, $p$) 17 F reaction is important to understand the light curves of x-ray bursts. The measurement will be performed using the Texas Active Target TPC version 2 (TexAT_v2). The TexAT_v2 aims at measuring lower energy protons from the reaction than the original TexAT. Newly developed silicon and CsI(Tl) detector arrays are added at the left, right and bottom of a modified field cage to increase its detection efficiency. Furthermore, this paper describes the overall specifications and two commissioning experiments performed at Texas A&M University.

14O(α, p)17F↗

New determination of the branching ratio of the structure dependent radiative K + → e + ν e γ

The branching ratio of the structure dependent (SD) radiative K + → e + ν e γ decay relative to that of the K + → e + ν e (γ) decay including the internal bremsstrahlung (IB) process (K e2 (γ) ) has been measured in the J-PARC E36 experiment using plastic scintillator/lead sandwich detectors, in contrast to the previous E36 measurement, which used a CsI(Tl) calorimeter. In the analysis, the effect of IB was also taken into account in the SD radiative decay as $K$$^{SD}_{e2γ(γ)}$. By combining the new data with the previous E36 result after revision for the IB correction for $K$$^{SD}_{e2γ(γ)}$, a new value Br($K$$^{SD}_{e2γ(γ)}$)/Br(Ke 2(γ) ) = 1.20 ± 0.07 has e2γ(γ) e2γ(γ) been determined. This is consistent with a recent lattice QCD calculation, but larger than the expectation of Chiral Perturbation Theory (ChPT) at order O(p 4 ) and the previous KLOE value. Using the method to relate form factor and branching ratio described in the KLOE paper, the present result is also consistent with the form factor prediction based on a gauged nonlocal chiral quark model, but larger than that from ChPT at order O(p 6 ).

79 ASTRONOMY AND ASTROPHYSICS↗