Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cryostat”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Dynamics of superfluid helium in zero gravity

The Spacelab 2 superfluid helium experiment was designed to: (1) examine the behavior of capillary waves and measure their velocity and dampling; (2) study the sloshing motion of bulk superfluid helium in near-zero gravity in order to determine its effects on sensors and attitude control systems for far infrared telescopes; and (3) determine the temperature distributions in the liquid and their correlation with bulk motion. The experiment system includes a helium cryostat with a sensor head and a microcomputer to provide electrical excitation and gather and transmit resultant responses to the experiment teams on the ground. Astronaut intervention is possible.

Mason, P. V.↗

An adiabatic demagnetization refrigerator for infrared bolometers

Adiabatic demagnetization refrigerators have been built and installed in small portable liquid helium cryostats to test the feasibility of this method of cooling infrared bolometric detectors to temperatures below 0.3 K. Performance has been achieved which suggests that bolometer temperatures of 0.2 K can be maintained for periods of approximately 60 hours. Applications to sensitive infrared detection from ground-based telescopes and space satellites are discussed. Design data are given which permit the evaluation of refrigerator performance for a variety of design parameters.

Britt, R. D.↗

Sample Holder for Cryogenic Adhesive Shear Test

Five samples tested in one cooldown. Holder mounted in testing machine. Submerged in cryogenic liquid held in cryostat. Movable crosshead of testing machine moves gradually downward. Samples placed under tension, one after another, starting with top one; each sample fails in turn before next is stressed.

Ledbetter, F. E.↗

Passive Module for Cryogenic Refrigeration

Refrigeration module with no moving parts attaches to cold plate of cryostat to reduce temperature. Module includes evaporation chamber, condenser and absorption pump.

Brooks, W.↗

Motorized Cyrogenic Valve

Remotely-controlled cryogenic valve operates over temperature range from room temperature to 2 K. Valve used in helium dilution refrigerators, cryostats and adiabatic-demagnetization refrigerators.

Salerno, L.↗

Experiments with phase transitions at very high pressure

Diamond cells were constructed for use to 1 Mbar. A refrigerator for cooling diamond cells was adapted for studies between 15 and 300 K. A cryostat for superconductivity studies between 1.5 to 300 K was constructed. Optical equipment was constructed for fluorescence, transmission, and reflectance studies. X-ray equipment was adapted for use with diamond cells. Experimental techniques were developed for X-ray diffraction studies using synchrotron radiation. AC susceptibility techniques were developed for detecting superconducting transitions. The following materials were studied: compressed solidified gases (Xe, Ar), semiconductors (Ge, Si, GaAs), superconductors (Nb3Ge, Nb3Si, Nb3As, CuCl), molecular crystals (I).

Spain, I. L.↗

Fused silica mirror development for SIRTF

An advanced design, lightweight, fuse-quartz mirror of sandwich construction was evaluated for optical figure performance at cryogenic temperatures. A low temperature shroud was constructed with an integral mirror mount and interface to a cryostat for use in a vacuum chamber. The mirror was tested to 13 K. Cryogenic distortion of the mirror was measured interferometrically. Separate interferometry of the chamber window during the test permitted subtraction of the small window distortions from the data. Results indicate that the imaging performance of helium cooled, infrared telescopes will be improved using this type of mirror without correction of cryogenic distortion of the primary mirror.

Barnes, W. P., Jr.↗

A cryocooler for applications requiring low magnetic and mechanical interference

A very low-power, low-interference Stirling cryocooler is being developed based on principles and techniques described in several previous publications over the last four years. It differs in several important details from those built previously. It uses a tapered displacer based upon an analytical optimization procedure. The displacer is driven by an auxiliary piston and cylinder (rather than by mechanical linkage) using some of the working fluid itself to provide the driving force. This provides smooth, vibration-free motion, and, more importantly, allows complete mechanical and spatial separation of the cryostat from the pressure-wave generator. Either of two different pressure-wave generators can be used. One is a non-contaminating, unlubricated ceramic piston and cylinder. The other is a compressed-air-operated rubber diaphragm with motor-driven valves to cycle the pressure between appropriate limits.

Zimmerman, J. E.↗

A helium-3 refrigerator employing capillary confinement of liquid cryogen

A condensation refrigerator suitable for operation in a zero gravity space environment was constructed. The condensed liquid refrigerant is confined by surface tension inside a porous metal matrix. Helium-4 and helium-3 gases were condensed and held in a copper matrix. Evaporative cooling of confined liquid helium-4 resulted in a temperature of 1.4K. Using a zeolite adsorption pump external to the cryostat, a temperature of 0.6 K was achieved through evaporative cooling of liquid helium-3. The amount of time required for complete evaporation of a controlled mass of liquid helium-4 contained in the copper matrix was measured as a function of the applied background power. For heating powers below 18 mW the measured times are consistent with the normal boiling of the confined volume of liquid refrigerant. At background powers above 18 mW the rapid rise in the temperature of the copper matrix the signature of the absence of confined liquid occurs in a time a factor of two shorter than that expected on the basis of an extrapolation of the low power data.

Ennis, D. J.↗

On 3He bolometer systems

A 3He cryostat which was constructed to cool a germanium bolometer for use as an infrared detector at submillimeter wavelength is discussed. The system had better sensitivity than any other existing system for these wavelengths; the system could be improved if better optical coupling could be achieved between the bolometer and the incoming photon stream. Considerable effort was expended to improve this coupling. Even the best results however, fell short of an ideal system by a factor of nearly 5 in coupling efficiency.

Houck, J. R.↗

Neutron-transmutation-doped germanium bolometers

Six slices of ultra-pure germanium were irradiated with thermal neutron fluences between 7.5 x 10 to the 16th and 1.88 x 10 to the 18th per sq cm. After thermal annealing the resistivity was measured down to low temperatures (less than 4.2 K) and found to follow the relationship rho = rho sub 0 exp(Delta/T) in the hopping conduction regime. Also, several junction FETs were tested for noise performance at room temperature and in an insulating housing in a 4.2 K cryostat. These FETs will be used as first stage amplifiers for neutron-transmutation-doped germanium bolometers.

Palaio, N. P.↗

Bench cooling the Thematic Mapper

The present investigation is concerned with the bench cooling system which was developed in conjunction with the Thematic Mapper (TM), a second-generation earth resources sensor. A small, permanently evacuated dewar, which is carried into space with the instrument, is employed to provide thermal isolation for bench cooling IR detectors of many space-borne instruments. This approach has, however, a number of disadvantages. The system designed for cooling the TM makes, therefore, use of a new approach, involving a temporarily evacuated, take-apart dewar in combination with a temperature-controlled Joule-Thomson cryostat.

Kuyper, D. J.↗

The Infrared Astronomical Satellite (IRAS) mission

The Infrared Astronomical Satellite (IRAS) consists of a spacecraft and a liquid helium cryostat that contains a cooled IR telescope. The telescope's focal plane assembly is cooled to less than 3 K, and contains 62 IR detectors in the survey array which are arranged so that every source crossing the field of view can be seen by at least two detectors in each of four wavelength bands. The satellite was launched into a 900 km-altitude near-polar orbit, and its cryogenic helium supply was exhausted on November 22, 1983. By mission's end, 72 percent of the sky had been observed with three or more hours-confirming scans, and 95 percent with two or more hours-confirming scans. About 2000 stars detected at 12 and 25 microns early in the mission, and identified in the SAO (1966) catalog, have a positional uncertainty ellipse whose axes are 45 x 9 arcsec for an hours-confirmed source.

Neugebauer, G.↗

High pressure cosmochemistry applied to major planetary interiors: Experimental studies

Progress is reported on a project to determine the properties and boundaries of high pressure phases of the H2-He-H2O-NH3-CH4 system that are needed to constrain theoretical models of the interiors of the major planets. This project is one of the first attempts to measure phase equilibria in binary fluid-solid systems in diamond anvil cells. Vibrational spectroscopy, direct visual observations, and X-ray diffraction crystallography of materials confined in externally heated cells are the primary experimental probes. Adiabats of these materials are also measured in order to constrain models of heat flow in these bodies and to detect phase transitions by thermal anomalies. Initial efforts involve the NH3-H2O binary. This system is especially relevant to models for surface reconstruction of the icy satellites of Jupiter and Saturn. Thermal analysis experiments were completed for the P-X space, p4GPa:0 or = 0.50, near room temperature. The cryostat, sample handling equipment, and optics needed to extend the optical P-T-X work below room temperature was completed.

Nicol, M. F.↗

Germanium resistance thermometer calibration at superfluid helium temperatures

The rapid increase in resistance of high purity semi-conducting germanium with decreasing temperature in the superfluid helium range of temperatures makes this material highly adaptable as a very sensitive thermometer. Also, a germanium thermometer exhibits a highly reproducible resistance versus temperature characteristic curve upon cycling between liquid helium temperatures and room temperature. These two factors combine to make germanium thermometers ideally suited for measuring temperatures in many cryogenic studies at superfluid helium temperatures. One disadvantage, however, is the relatively high cost of calibrated germanium thermometers. In space helium cryogenic systems, many such thermometers are often required, leading to a high cost for calibrated thermometers. The construction of a thermometer calibration cryostat and probe which will allow for calibrating six germanium thermometers at one time, thus effecting substantial savings in the purchase of thermometers is considered.

Mason, F. C.↗

Infrared telescope

The development of the Infrared Telescope for Spacelab 2 is discussed. The design, development, and testing required to interface a stationary superfluid helium dewar with a scanning cryostate capable of operating in the zero-g environment in the space shuttle bay is described.

Karr, G. R.↗

Superconducting electromagnets for large wind tunnel magnetic suspension and balance systems

A superconducting electromagnetic suspension and balance system for an 8 x 8-ft, Mach 0.9 wind tunnel is presented. The system uses a superconducting solenoid as a model core 70 cm long and with a 11.5 cm OD, and a combination of permanent magnet material in the model wings to produce the required roll torque. The design, which uses an integral cold structure rather than separate cryostats for mounting all control magnets, has 14 external magnets, including 4 racetrack-shaped roll coils. Helium capacity of the system is 3.0 to 3.5 l with idling boiloff rate predicted at 0.147 to 0.2 l/h. The improvements yielded a 50-percent reduction in the system size, weight, and cost.

Boom, R. W.↗

Nuclear Science Symposium, 31st and Symposium on Nuclear Power Systems, 16th, Orlando, FL, October 31-November 2, 1984, Proceedings

Topics related to physics instrumentation are discussed, taking into account cryostat and electronic development associated with multidetector spectrometer systems, the influence of materials and counting-rate effects on He-3 neutron spectrometry, a data acquisition system for time-resolved muscle experiments, and a sensitive null detector for precise measurements of integral linearity. Other subjects explored are concerned with space instrumentation, computer applications, detectors, instrumentation for high energy physics, instrumentation for nuclear medicine, environmental monitoring and health physics instrumentation, nuclear safeguards and reactor instrumentation, and a 1984 symposium on nuclear power systems. Attention is given to the application of multiprocessors to scientific problems, a large-scale computer facility for computational aerodynamics, a single-board 32-bit computer for the Fastbus, the integration of detector arrays and readout electronics on a single chip, and three-dimensional Monte Carlo simulation of the electron avalanche in a proportional counter.

Biggerstaff, J. A.↗