Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Criticality Safety”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Cyclomatic Complexity and Basis Path Testing Study

The NASA Chief Engineer requested the NASA Engineering and Safety Center (NESC) to conduct a study to determine the benefits of cyclomatic complexity and basis path testing (BPT) for software and whether they should be required. The principal focus of the assessment was to assess the use of cyclomatic complexity and BPT on safety-critical software. The purpose was to ensure that safety-critical software is not overly complicated to the point of increasing coding errors and that verification is more robust than for non-safety-critical software. This document contains the outcome of the assessment.

Cyclomatic Complexity; NASA Engineering and Safety↗

Formal Methods in the Development of Highly Assured Software for Unmanned Aircraft Systems

In traditional software development methodologies, operational and functional requirements of systems are often specified in structured natural language notations. These restricted notations provide good documentation support, but only provide limited support for semantic analysis. These notations are generally not rich enough to unambiguously specify the requirements of safety-critical systems that, for example, involve complex numerical computations or that interact with the physical environment. Examples of these safety-critical systems are autonomous vehicles such as unmanned aircraft systems. This talk advocates the use of expressive formal logics, such as higher-order logic, to specify the operational and functional requirement of unmanned systems and to prove the correctness of these requirements. Semantic analysis of requirements written in higher-order logic is supported through the use of interactive theorem provers. Formal models serve as ideal reference implementations of functional requirements. Hence, formal logics enable software validation techniques where software implementations can be checked against functional requirements in a mechanical way. The Formal Methods group in the Safety-Critical Avionics Systems Branch at NASA Langley Research Center has conducted research on the development and application of formal verification techniques to safety-critical applications of interest to NASA for more than 30 years. This talk illustrates the use of formal methods in the development of highly-assured autonomous unmanned aircraft systems.

Formal Methods↗

Delayed Critical Enriched Uranium Metal, 7-in.-diam. Cylinder with Thin Stainless Steel Top and Bottom Reflectors

Three 7 in. diameter highly enriched uranium (HEU; 93.17 wt % 235 U) metal cylinders were assembled on the vertical assembly machine of the Oak Ridge Critical Experiments Facility (ORCEF) with thin stainless steel reflectors (0.5, 1, and 2 in. thick) on the top and bottom. These experiments were performed during January 13–25, 1965, and used seven operational days at ORCEF. Before these experiments, unreflected and unmoderated 7 in. diameter HEU metal cylinders had been assembled to delayed criticality at ORCEF, and the results were benchmarked in HEU-MET-FAST-051. In addition to the critical experiments, the prompt neutron decay constant was measured via the Rossi-α technique, and those results are also presented in this report. To achieve near-delayed-critical systems, 5 × 5 × 0.03125 in. rectangular uranium metal parts were used on top of 7 in. diameter cylinders inside the top reflector. The delayed critical configuration from the three experiments described herein are acceptable for use as criticality safety benchmark experiments for the International Criticality Safety Benchmark Evaluation Program (ICSBEP), coordinated by the Nuclear Energy Agency, once the uncertainty analysis is completed. Based on previous ICSBEP benchmarks with this enriched uranium metal at ORCEF, the uncertainty in $k_{eff}$ is expected to be as low as ±0.0002. The prompt neutron time decay data could be the basis of an International Reactor Physics Evaluation Program benchmark.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Capturing Safety Requirements to Enable Effective Task Allocation Between Humans and Automaton in Increasingly Autonomous Systems

There is a current drive towards enabling the deployment of increasingly autonomous systems in the National Airspace System (NAS). However, shifting the traditional roles and responsibilities between humans and automation for safety critical tasks must be managed carefully, otherwise the current emergent safety properties of the NAS may be disrupted. In this paper, a verification activity to assess the emergent safety properties of a clearly defined, safety critical, operational scenario that possesses tasks that can be fluidly allocated between human and automated agents is conducted. Task allocation role sets were proposed for a human-automation team performing a contingency maneuver in a reduced crew context. A safety critical contingency procedure (engine out on takeoff) was modeled in the Soar cognitive architecture, then translated into the Hybrid Input Output formalism. Verification activities were then performed to determine whether or not the safety properties held over the increasingly autonomous system. The verification activities lead to the development of several key insights regarding the implicit assumptions on agent capability. It subsequently illustrated the usefulness of task annotations associated with specialized requirements (e.g., communication, timing etc.), and demonstrated the feasibility of this approach.

Neogi, Natasha A.↗

Health Physics Research Reactor Criticality Accident Alarm System Benchmark Overview

From the countless critical experiments performed in the world during the past century, high-quality integral benchmarks experiments have been collected and gathered into the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook), managed by the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Working Group. This information preservation and dissemination effort is crucial for reactor licensing as well as criticality and radiation transport modeling validation. This summary reports on the status of a tentative benchmark addition to the ICSBEP Handbook. The proposed benchmark arises from legacy operation data of the Oak Ridge National Laboratory (ORNL) Health Physics Research Reactor (HPRR). The HPRR was a small, unmoderated, unshielded fast burst reactor that was used for research in health physics and radiobiology as well as teaching and training. As part of a comprehensive investigation of the available HPRR operation data and characteristics, different possibilities for use of the valuable results were studied. A critical experiment benchmark evaluation was performed, analyzing data coming from sub-critical and critical operation of the HPRR during operator training, steady-state irradiation of samples and before critical bursts. The results of the evaluation do not satisfy for the ICSBEP standards as the benchmark relative standard uncertainty is of about 4% for k eff , and the relative difference between sample calculations and expected k eff results is of about 1.5%. Due to those unsatisfactory results, it was decided not to pursue critical experiments evaluation of the HPRR presently and to focus instead on shielding type data for the creation of a criticality accident alarm system (CAAS) and shielding category benchmark, which is currently very scarce in the ICSBEP handbook—especially concerning critical, pulsed assembly, or reactor operation data. Several dosimetry and shielding experiments from HPRR burst operation were evaluated, with different benchmark metrics as sulfur fluence, Element 57 dose, or neutron fluence at different distances and under different shield materials conditions. An evaluation focusing on the Element 57 neutron dose as a benchmark metric was submitted to the ICSBEP Technical Review Group (TRG) meeting in October 2021, and the inclusion of the evaluation in the ICSBEP Handbook was deferred. The main change proposed by the international experiment evaluation experts is to use the neutron fluence measured by Bonner spheres as a benchmark metric. This represents a quantity closer to that actually measured by the experimentalists of the HPRR compared to the Element 57 dose, which adds another step of data transformation, thus potentially adding uncertainty to the benchmark. The evaluation has been updated and will be submitted to the 2022 ICSBEP TRG meeting for inclusion in the 2023 edition of the ICSBEP Handbook. The evaluation is performed using the KENO and MAVRIC combination from the SCALE 6.2.4 code suite which was previously used in similar CAAS benchmarks to allow for the use of variance reduction techniques.

61 RADIATION PROTECTION AND DOSIMETRY↗

NCS Pipeline UC Berkeley Course Overview [Slides]

The criticality safety divisions at Lawrence Livermore National Laboratory (LLNL) and Los Alamos National Laboratory (LANL), in partnership with Dr. Max Fratoni of UC Berkeley, taught the fourth annual nuclear criticality safety course during the fall 2021 semester at UC Berkeley. This course is part of a larger pipeline project designed to stimulate student interest in the field of criticality safety.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Utilizing Code Generation from Models for Electric Aircraft Motor Controller Flight Software

The processes followed to develop and test safety-critical flight software significantly increase development effort and overhead in comparison to both non-safety-critical and non-flight software. Generating code from models can be used to reduce development effort; however, the processes for using code generation to develop flight software are relatively immature. This work presents an approach for developing safety-critical flight software utilizing code generation from models to reduce development time and effort. The presented use-case is of electric aircraft motor control software developed for NASA's X-57 Maxwell aircraft.

flight software↗

Software Safety Progress in NASA

NASA has developed guidelines for development and analysis of safety-critical software. These guidelines have been documented in a Guidebook for Safety Critical Software Development and Analysis. The guidelines represent a practical 'how to' approach, to assist software developers and safety analysts in cost effective methods for software safety. They provide guidance in the implementation of the recent NASA Software Safety Standard NSS-1740.13 which was released as 'Interim' version in June 1994, scheduled for formal adoption late 1995. This paper is a survey of the methods in general use, resulting in the NASA guidelines for safety critical software development and analysis.

Radley, Charles F.↗

Assessment of Critical Experiment Benchmark Applicability to a Large-Capacity HALEU Transportation Package Concept

This work presents an assessment of the applicability of existing benchmark critical experiments to the criticality safety code validation for a large-capacity high-assay low-enriched uranium (HALEU) transportation package concept. Numerous next-generation nuclear reactor designs require HALEU fuel, which is characterized by an enrichment between 5 and 20 wt% 235 U. The U.S. Department of Energy (DOE) has proposed to recover and downblend highly enriched uranium from DOE-owned used nuclear fuel to accelerate the demonstration of commercially viable microreactor technologies. One element of the infrastructure needed to demonstrate HALEU-fueled reactors is the ability to safely transport enriched product to be used for fuel fabrication. There is uncertainty as to whether existing critical benchmark experiment data are sufficient to support criticality safety code validation for HALEU transportation applications. The anticipated chemical form of the HALEU in the proposed transportation concept is UO 2 with 20 wt% 235 U/U. The concept uses a combination of an existing transportation packaging design and a novel basket design, including borated aluminum flux traps. The basket provides space for 18 reusable, stainless steel canisters that contain the HALEU. In 10 CFR 71, normal conditions of transport (NCTs) and hypothetical accident conditions (HACs) are defined for fissile material transportation packages. NCT and HAC KENO-VI models of the transportation package were developed using the Standardized Computer Analyses for Licensing Evaluation (SCALE) 6.2.3 computer code package, and optimum moderation conditions were determined using the SCALE SAMPLER sequence. The SCALE Tools for Sensitivity and Uncertainty Analysis Methodology Implementation (TSUNAMI) sequences were then used to compare the neutronic characteristics of 1584 International Criticality Safety Benchmark Evaluation Project benchmark critical experiments with the NCT and HAC HALEU transportation models. The TSUNAMI integral correlation coefficient c k was the criterion used to rank neutronic similarity. Thirty-four experiments were identified as similar (c k ≥ 0.9) to the NCT model, and 55 experiments were identified as similar to the HAC model. Hundreds of experiments were also identified as at least marginally similar (c k ≥ 0.8) to both models. The results indicate that additional critical experiments are unlikely to be needed to support HALEU transportation criticality safety analyses for package concepts similar to the concept package analyzed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

HEU Metal Delayed Critical Experiments with 10 to 19 Inch Thick Graphite Reflectors

Approximately 100 graphite-reflected highly enriched uranium (HEU, 93.14 wt % 235 U) metal annular and cylindrical critical experiments were performed in the early 1960s at the Oak Ridge Critical Experiments Facility (ORCEF). This report presents details from experiment logbooks, experimental data sheets and the author's memory for 44 HEU metal (93.14 wt % 235 U) critical assemblies with graphite reflectors varying from 10 to 19 in. thick, outside diameters varying from 7 to 15 in., inside diameters varying from 7 to 13 in. and critical HEU metal masses varying from 20.4 to 69.0 kg. The data from the 44 experiments described in this report are acceptable for use as criticality safety benchmark experiments for the International Criticality Safety Evaluation Program (ICSBEP) once the uncertainty analysis on the measured k eff is completed. Based on previous ICSBEP benchmarks with this HEU metal at ORCEF, the uncertainties in the measured k eff are expected to be as low as ±0.0004. Preparation of this report is part of an effort at Oak Ridge National Laboratory (ORNL) to document more than 15 undocumented series of critical and subcritical experiments enumerated in Critical and Subcritical NEA Benchmark Possibilities for Measurements at ORCEF and Other US DOE Facilities (Mihalzo, ORNL/TM-2019/1188, 2019) and performed by ORNL at ORCEF and other US Department of Energy critical experiments facilities. More than 500 operational days of critical facility time were used, not including setup and dismantlement time. This documentation for a part of one series of graphite reflected highly enriched uranium metal critical experiments, that used 50 operational days of ORCEF time, was performed using funding received from the DOE Office of Nuclear Energy’s Nuclear Energy University Programs at the University of Tennessee Nuclear Engineering Department. This documentation was also supported by the Nuclear Criticality, Radiation Transport, and Safety programs at ORNL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

NCSP Outlook and Interest for Collaboration on HST Experiments [Slides]

The majority of the NCSP budget goes to Integral Experiments. The goal is to produce needed integral data for criticality safety needs in DOE, largely resulting in ICSBEP benchmarks. NCSP has a well defined process for allocating funding through proposals and expert review. NCSP is a fairly small program and funding is prioritized for experiments that would address DOE criticality safety needs. The majority of the currently identified DOE criticality safety needs are HEU and Pu systems. NCSP has a formal mechanism to ensure quality and benefit through the phase gates and approvals within the CED process.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fuel Debris Monitoring Collaboration and Experiences in Criticality Monitoring

Fukushima Daiichi fuel debris removal provides technical challenges and opportunities for the international criticality safety community. The US DOE-NCSP (Nuclear Criticality Safety Program) and France (IRSN) will support 1F fuel debris efforts through collaboration on real-time criticality monitoring. This work will describe a collaboration that is starting soon and will also describe previous efforts associated with criticality experiments and neutron analysis of unknown systems.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

IV and V Issues in Achieving High Reliability and Safety in Critical Control System Software

Risk analysis and integrated verification and validation are two important elements in a plan for ensuring the safety of critical software systems. We describe an approach we are currently developing for integrating risk analysis, and metrics analysis, and propose a fault predictor that would integrate the results of these activities. Practical difficulties associated with our approach are also discussed, as are limitations of the proposed predictor. We conclude with a discussion of what as been learned to date, and with suggestions for future work.

validation software reliability software risk asse↗

Comparison Study of Upper Subcritical Limits Derived Using Sensitivity/Uncertainty Tools Case Studies of Benchmarks and Applications

Neutron transport methods used to establish subcriticality require validation by comparison to critical experiments considered to be benchmarks. Whisper is a sensitivity/uncertainty analysis tool developed to assist with the task of validation in nuclear criticality safety. Details on the Whisper methodology can be found in References 1-3 on the MCNP ® reference collection website at https://mcnp.lanl.gov. Whisper-1.0 was originally developed in 2014 and used to assist with nuclear criticality safety validation at Los Alamos National Laboratory. Whisper was upgraded in 2016 to Whisper-1.1 and prepared for release with MCNP6.2. Whisper contains a library of over 1100 critical experiment benchmarks and quantifies neutronic similarity of an application to benchmarks in the library. Using highest similarity benchmarks, Whisper computes a calculational margin (CM) encompassing of the worst-case bias and bias uncertainty at a 99% confidence level for each application. In addition, portions of the margin of subcriticality (MOS) for nuclear data uncertainty and potential code errors are computed. The baseline upper subcritical limit (USL) computed by Whisper is comprised of the CM, MOS nuclear data , and MOS code errors . The Whisper baseline USL is absent a portion of the MOS due to the area of application, which is applied based upon judgment by the criticality safety analyst. An objective of this paper is to present the baseline USL, CM and portions of the MOS as computed by Whisper for comparison with similar sensitivity/uncertainty tools, such as those used by IRSN and ORNL. The initial comparison involves four critical experiment benchmarks: HEU-MET-FAST-013-001, HEU-SOLTHERM-001-008, PU-MET-FAST-022-001, AND PU-SOL-THERM-001-001, which have been: 1. modeled independently by LANL, IRSN, and ORNL based upon information provided in the ICSBEP Handbook, 2. are common in S/U libraries for LANL, IRSN, and ORNL, 3. span a range of energy spectrum and fissile material, and 4. taken as applications for the purposes of this study and therefore excluded from use as a benchmark for calculating the upper subcritical limit. Results presented in this paper have been computed using covariance data for all isotopes in ENDF/BVII.0 using a 44-group energy structure. Benchmarks in the Whisper library were run in MCNP6.2 using 100,000 neutrons per cycle, skipping 100 cycles for 500 active cycles. Reference 10 also compares the results for baseline USL with an order of magnitude greater neutrons, using the same total number of cycles with 1,000,000 neutrons per cycle. Subsequent to the results presented in Reference 10 changes were made to the benchmark library, as discussed in Reference 11. Newer results using the revised benchmark library are presented herein.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison Study of Upper Subcritical Limits Derived Using Sensitivity/Uncertainty Tools: Case Studies of U233-SOL-THERM-001-001, MIX-COMP-THERM-001-001, IEU-MET-FAST-002-001, LEU-COMP-THERM-001-001, LEU-SOL-THERM-004-001

Neutron transport methods used to establish subcriticality require validation by comparison to critical experiments considered to be benchmarks. Whisper is a sensitivity/uncertainty analysis tool developed to assist with the task of validation in nuclear criticality safety. Details on the Whisper methodology can be found in References 1-3 on the MCNP® reference collection website at https://mcnp.lanl.gov. Whisper-1.0 was originally developed in 2014 and used to assist with nuclear criticality safety validation at Los Alamos National Laboratory. Whisper was upgraded in 2016 to Whisper-1.1 and prepared for release with MCNP6.2 [References 3-5]. Whisper contains a library of over 1100 critical experiment benchmarks and quantifies neutronic similarity of an application to benchmarks in the library. Using highest similarity benchmarks, Whisper computes a calculational margin (CM) encompassing of the worst-case bias and bias uncertainty at a 99% confidence level for each application. In addition, portions of the margin of subcriticality (MOS) for nuclear data uncertainty and potential code errors are computed. The baseline upper subcritical limit (USL) computed by Whisper is comprised of the CM, MOS nuclear data , and MOS code errors . The Whisper baseline USL is absent a portion of the MOS due to the area of application, which is applied based upon judgment by the criticality safety analyst. An objective of this paper is to present the baseline USL, CM and portions of the MOS as computed by Whisper for comparison with similar sensitivity/uncertainty tools, such as those used by IRSN and ORNL. An initial comparison involved four critical experiment benchmarks: HEU-MET-FAST-013-001, HEU-SOLTHERM-001-008, PU-MET-FAST-022-001, AND PU-SOL-THERM-001-001, which have been documented in References 10-13. This study extends the comparison to include cases U233-SOL-THERM-001-001, MIX-COMP-THERM-001-001, IEU-MET-FAST-002-001, LEU-COMP-THERM-001-001, LEU-SOL-THERM- 004-001.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Generalized implementation of software safety policies

As part of a research program in the engineering of software for safety-critical systems, we are performing two case studies. The first case study, which is well underway, is a safety-critical medical application. The second, which is just starting, is a digital control system for a nuclear research reactor. Our goal is to use these case studies to permit us to obtain a better understanding of the issues facing developers of safety-critical systems, and to provide a vehicle for the assessment of research ideas. The case studies are not based on the analysis of existing software development by others. Instead, we are attempting to create software for new and novel systems in a process that ultimately will involve all phases of the software lifecycle. In this abstract, we summarize our results to date in a small part of this project, namely the determination and classification of policies related to software safety that must be enforced to ensure safe operation. We hypothesize that this classification will permit a general approach to the implementation of a policy enforcement mechanism.

Knight, John C.↗

Two Delayed Critical 15-Inch-Diameter Interacting Enriched (93.14) Uranium Metal Cylinders without Moderator and Reflector

This report documents very accurately the configuration and the materials for experiments with two unmoderated, unreflected, interacting, coaxial, highly enriched, 15-in.-diameter, uranium metal cylinders performed at the Oak Ridge Critical Experiments Facility (ORCEF) in May to Aug 1963 and described in logbook E-19 and E -20 associated with experiments in the East cell of ORCEF. Measurements were also performed in April and May of 1965 and described in logbooks E-22 and E-23 The information is sufficiently accurate that it can be used as the basis for preparation of benchmarks for International Criticality Safety Benchmark Program (ICSBEP) at Idaho National laboratory. The thickness of the cylinders was varied and the spacing between them was adjusted to achieve a delayed critical configuration. The average enrichment of the uranium metal was 94.14 wt. % 235 U. The heights of the 15-in.-diameter, equal-height cylinders varied from 1-5/8 to 3.0-inches. All interacting cylinders were assembled coaxially with their flat faces parallel and their combined masses varied between 182 and 325 kilograms of HEU metal. The data from these 12 experiments described would be acceptable for use as criticality safety benchmark experiments for the ICSBEP and EURATOM’s Nuclear Energy Agency nuclear criticality safety benchmark program, once the uncertainty analysis is completed. Based on previous ICSBEP benchmarks with this enriched uranium metal at ORCEF, it is expected that the uncertainties in k eff could be as low as ± 0.0002.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗