At least 325 records · Page 18

Repair and Utilization of the Kratos XSAM 800 X-Ray Photoelectron Spectrometer (XPS)

The objectives for this summer faculty fellowship were first to repair the Kratos XSAM 800 X-ray Photoelectron Spectrometer (XPS) and then to utilize the instrument to participate in ongoing research projects at KSC and in the researcher's own laboratory at UCF. The first 6 weeks were used in repairing the instrument. Working both alone and with the Kratos service engineer, a number of hardware problems, largely associated with the sample stage control system, were corrected. Defective parts were identified and fixed in the computer driver boards, the stage power supply, and the driver interface. The power supply was completely replaced. After four weeks of work, the instrument was functional. This occurred on a Wednesday. The following Friday the instrument had to be completely shut down because the power to the O & C Building was to be turned off. The instrument was properly secured. On Monday, the instrument was powered up and the original problems returned. After another 2 weeks of work, a software problem was identified. This problem caused the computer to use a defective port for the sample stage control. It was circumvented by rewriting the startup routine. The final 3 weeks of the fellowship were spent using the XPS to analyze samples being studied in the Langley materials project (Martha Williams) and a catalyst project (Dr. Orlando Melendez). During this time, several sample analysis requests from other groups at KSC also came in and those samples were run as well. The summer faculty fellowship also allowed many contacts to be made. After meeting with the sensors group, two projects were identified for collaboration and white papers are being prepared. One project aims to develop small, very sensitive hydrogen detectors and the other to develop a broad area, easily monitored, zero power consumption hydrogen detector. In addition to the work mentioned above, the XPS was utilized in a study underway in Dr. Hampton's laboratory at UCF.

Hampton, Michael D.↗

Sample Delivery and Computer Control Systems for Detecting Leaks in the Main Engines of the Space Shuttle

The main engines of the Space Shuttle use hydrogen and oxygen as the fuel and oxidant. The explosive and fire hazards associated with these two components pose a serious danger to personnel and equipment. Therefore prior to use the main engines undergo extensive leak tests. Instead of using hazardous gases there tests utilize helium as the tracer element. This results in a need to monitor helium in the ppm level continuously for hours. The major challenge in developing such a low level gas monitor is the sample delivery system. This paper discuss a system developed to meet the requirements while also being mobile. Also shown is the calibration technique, stability, and accuracy results for the system.

Griffin, Timothy P.↗

Optimal regulation in systems with stochastic time sampling

An optimal control theory that accounts for stochastic variable time sampling in a distributed microprocessor based flight control system is presented. The theory is developed by using a linear process model for the airplane dynamics and the information distribution process is modeled as a variable time increment process where, at the time that information is supplied to the control effectors, the control effectors know the time of the next information update only in a stochastic sense. An optimal control problem is formulated and solved for the control law that minimizes the expected value of a quadratic cost function. The optimal cost obtained with a variable time increment Markov information update process where the control effectors know only the past information update intervals and the Markov transition mechanism is almost identical to that obtained with a known and uniform information update interval.

Montgomery, R. C.↗

Experimental measurement of the plasma conductivity of Z93 and Z93P thermal control paint

Two samples each of Z93 and Z93P thermal control paint were exposed to a simulated space environment in a plasma chamber. The samples were biased through a series of voltages ranging from -200 volts to +300 volts and electron and ion currents measured. By comparing the currents to those of pure metal samples of the same size and shape, the conductivity of the samples was calculated. Measured conductivity was dependent on the bias potential in all cases. For Z93P, conductivity was approximately constant over much of the bias range and we find a value of 0.5 micro-mhos per square meter for both electron and ion current. For Z93, the dependence on bias was much more pronounced but conductivity can be said to be approximately one order of magnitude larger. In addition to presenting these results, this report documents all of the experimental data as well as the statistical analyses performed.

Hillard, G. Barry↗

Multispectral signatures in relation to ground control signatures using nested sampling approach

The author has identified the following signficant results. An experiment was conducted to evaluate the feasibility of using ERTS-1 MSS imagery for spot transmission measurements on selected sites. Using the 15-unit gray scale on the 70 mm positive imagery as the base of comparison, a correlation was made between the transmittance measured at each site on the imagery and the radiance values (counts) recorded on CCT tape by the spacecraft over the same sites. The imagery was enlarged by a 750-watt projector and focused on a white cardboard screen 6 meters from the screen. Observations were made on 30 sub-sites which were pre-selected for their differing image brightness and total area; all are dried pond beds. Observations were also made on average gray backgrounds and a small lake. There was a very good correlation between the density values obtained from projected imagery and radiance values received by the detector on the spacecraft. A shorter experiment time and closer integration of gray scale and site readings would avoid the variation in lamp intensities that occurred.

Lyon, R. J. P.↗

Multispectral signatures in relation to ground control signature using nested sampling approach

The author has identified the following significant results. Principal effort has been on the development of a PDP-10 software package to read the CCT tapes more cheaply and rapidly. This is 90% completed and debugged. A shade print example of Treasure Island is provided. Stanford area was overflown with the U-2 as an add-on photographic mission to help fill in record-gaps in ERTS-1 overpass which was clouded out.

Lyon, R. J. P.↗

Multispectral signatures in relation to ground control signature using nested sampling approach

The author has identified the following significant results. In a cooperative study with USGS personnel, it has been possible to detect a 1.5 by 1 mile anomaly on ERTS CCT data, in the pine-covered mountains of western Nevada. This anomalous area is about 3-5 times larger than that of the known geobotanical anomaly which lies centrally within the area. The site has been studied on the ground and bi-directional reflectances, relative to BaS04 obtained for 40 trees, using both in-vivo techniques (similar to cherry picker operations) and field determinations of cut branches. The anomaly can be seen best by color transparencies made from 5/4, 6/4, 7/4 ratioed digital data, the 3 ratios each being coded by one of 3 colors (blue, green, and red).

Lyon, R. J. P.↗

Some effects of digital sampling on orbiter flight control system operation

An entry dynamic stability ground test of the OV102 Space Shuttle Orbiter revealed some small amplitude oscillatory output of the flight control system which could have constrained flight of the STS-1 mission. These limit-cycle-type outputs were attributed to a combination of rigid body motion of the Orbiter on its landing gear and some interesting effects of its digital flight control system. These effects included frequency aliasing and phenomena associated with digital quantitization of low amplitude sensor signals. The digital effects suggest significant improvements possible in future designs.

Murray, S. V.↗

Direct Adaptive Control Of An Industrial Robot

Decentralized direct adaptive control scheme for six-jointed industrial robot eliminates part of overall computational burden imposed by centralized controller and degrades performance of robot by reducing sampling rate. Control and controller-adaptation laws based on observed performance of manipulator: no need to model dynamics of robot. Adaptive controllers cope with uncertainties and variations in robot and payload.

Seraji, Homayoun↗

Laser-induced fluorescence of space-exposed polyurethane

The object of this work was to utilize laser-induced fluorescence technique to characterize several samples of space-exposed polyurethane. These samples were flown on the Long Duration Exposure Facility (LDEF), which was in a shuttle-like orbit for nearly 6 years. Because of our present work to develop laser-induced-fluorescence inspection techniques for polymers, space-exposed samples and controls were lent to us for evaluation. These samples had been attached to the outer surface of LDEF; therefore, they were subjected to thermal cycling, solar ultraviolet radiation, vacuum, and atomic oxygen. It is well documented that atomic oxygen and ultraviolet exposure have detrimental effects on many polymers. This was a unique opportunity to make measurements on material that had been naturally degraded by an unusual environment. During our past work, data have come from artificially degraded samples and generally have demonstrated a correlation between laser-induced fluorescence and tensile strength or elasticity.

Hill, Ralph H., Jr.↗