Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Compton”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

TU-CD-304-10: Development and Optimization of “Compton Lens” Collimator Design for Increased Dose Rate in SRS

Purpose: To provide a proof of concept for a new collimator design to increase the dose rate at isocenter for stereotactic radiosurgery (SRS) treatments by taking advantage of off axis Compton scattered photons which are attenuated in current collimators. Methods: A fundamentally new collimator design was developed and optimized by introducing a series of slits to a standard block collimator. The introduction of slits allowed for initially off axis radiation that was scattered in the direction of the target to contribute to the target dose. For optimization, the design was broken into two parts: an upper interaction plate where primary scattering occurs, and a lower “Compton slit” region which allows for scattered photons traveling toward the target to reach isocenter. To optimize the design, a series of simulations were performed using MCNP6 in which several key parameters were adjusted and the output was compared to a standard collimator. Key parameters modified included the collimator material, cone size, and interaction plate thickness. The effects of using energies different than the traditional 6 MV beam were also explored. Results: An optimized collimator design utilizing a solid interaction plate with a Cesium-137 beam and a 4 mm cone size resulted in a dose rate increase on the order of 5% relative to standard collimators in use. Currently, designs incorporating a Cesium-137 source are the most feasible due to necessary size and weight concerns for 6 MV beams. Conclusion: Preliminary designs provide a proof of concept and indicate a potential to improve upon the dose rate of current collimators while not largely compromising the sharp dose falloff inherent to SRS. Further optimization into the geometry and positioning of the interaction plate, as well as slit optimization, will likely lead to further dose rate increases than were observed in this study. Funding for this work was provided by the Wisconsin Alumni Research Foundation (WARF). Authors have a conflict of interest as the technology discussed is patent pending, and thus there is a financial interest in the work.

60 APPLIED LIFE SCIENCES↗

SU-F-J-200: An Improved Method for Event Selection in Compton Camera Imaging for Particle Therapy

Purpose: The uncertainty in the beam range in particle therapy limits the conformality of the dose distributions. Compton scatter cameras (CC), which measure the prompt gamma rays produced by nuclear interactions in the patient tissue, can reduce this uncertainty by producing 3D images confirming the particle beam range and dose delivery. However, the high intensity and short time windows of the particle beams limit the number of gammas detected. We attempt to address this problem by developing a method for filtering gamma ray scattering events from the background by applying the known gamma ray spectrum. Methods: We used a 4 stage Compton camera to record in list mode the energy deposition and scatter positions of gammas from a Co-60 source. Each CC stage contained a 4×4 array of CdZnTe crystal. To produce images, we used a back-projection algorithm and four filtering Methods: basic, energy windowing, delta energy (ΔE), or delta scattering angle (Δθ). Basic filtering requires events to be physically consistent. Energy windowing requires event energy to fall within a defined range. ΔE filtering selects events with the minimum difference between the measured and a known gamma energy (1.17 and 1.33 MeV for Co-60). Δθ filtering selects events with the minimum difference between the measured scattering angle and the angle corresponding to a known gamma energy. Results: Energy window filtering reduced the FWHM from 197.8 mm for basic filtering to 78.3 mm. ΔE and Δθ filtering achieved the best results, FWHMs of 64.3 and 55.6 mm, respectively. In general, Δθ filtering selected events with scattering angles < 40°, while ΔE filtering selected events with angles > 60°. Conclusion: Filtering CC events improved the quality and resolution of the corresponding images. ΔE and Δθ filtering produced similar results but each favored different events.

60 APPLIED LIFE SCIENCES↗

Experiments with compton back scattered gamma beams (on GRAAL collaboration results)

Experimental study of photonuclear reactions using Compton back scattered gamma beams at intermediate energies (from pion photoproduction threshold up to a few GeV) is reviewed. The last review of this subject was published about 10 years ago. Since then, new fundamental data on nucleon spin structure and photonuclear excitation mechanisms have appeared in the literature. Principal attention in the present review is paid to the GRAAL (Grenoble Accelerateur Anneau Laser) experiment conducted at ESRF (European Synchrotron Radiation Facility). It is shown that, in addition to the principal polarization experimental program based on high degree of gamma beam polarization, new results on different applications have been obtained. For example, total photoabsorption and partial meson photoproduction cross sections were measured with high accuracy, and a new method for studying an interaction of unstable short-lived mesons with nuclear media (tagged mesons) was proposed. New results on anisotropy of the speed of light with respect to the dipole of cosmic microwave background radiation were evaluated. It is noted that new opportunities arise due to unique conditions appearing while conducting the experiments with the Compton back scattering technique, which provides the hard photon spectrum, high degree of beam polarization, and low backgrounds.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Determination of the scalar polarizabilities of the proton using beam asymmetry $\Sigma_{3}$ in Compton scattering

The scalar dipole polarizabilities, α E1 and β M1 , are fundamental properties related to the internal dynamics of the nucleon. The currently accepted values of the proton polarizabilities were determined by fitting to unpolarized proton Compton scattering cross section data. The measurement of the beam asymmetry Σ 3 in a certain kinematical range provides an alternative approach to the extraction of the scalar polarizabilities. At the Mainz Microtron (MAMI) the beam asymmetry was measured for Compton scattering below pion photoproduction threshold for the first time. Finally, the results are compared with model calculations and the influence of the experimental data on the extraction of the scalar polarizabilities is determined.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Double deeply virtual Compton scattering with positron beams at SoLID

Double Deeply Virtual Compton Scattering (DDVCS) is the only experimental channel for the determination of the dependence of the Generalized Parton Distributions (GPDs) on both the average and the transferred momentum independently. The physics observables of the electron induced di-muon production reaction $\vv{e}^{\pm}p \to e^{\pm}p\mu^+\mu^-$ off unpolarized hydrogen are discussed. Their measurement with the high luminosity and large acceptance SoLID spectrometer at the Thomas Jefferson National Accelerator Facility, using polarized and unpolarized positron and electron beams at 11 GeV is investigated. This experimental configuration is shown to provide unprecedented access to the GPDs with the determination of the real and imaginary parts of the Compton Form Factor H in an unexplored phase space, and to enable an exploratory investigation of higher twist effects.

Zhao, S.↗

Improving performance of inverse Compton sources through laser chirping

We present a new method for computation of radiation spectra in the non-linear regime of operation of inverse Compton sources characterized by high laser intensities. The resulting simulations agree well with the experiments. Increasing the laser intensity changes the longitudinal velocity of the electrons during their collision, leading to considerable non-linear broadening in the scattered radiation spectra. The effects of such ponderomotive broadening are so deleterious that most inverse Compton sources either remain at low laser intensities or pay a steep price to operate at a small fraction of the physically possible peak spectral output. This ponderomotive broadening can be reduced by a suitable frequency modulation (also referred to as "chirping", which is not necessarily linear) of the incident laser pulse, thereby drastically increasing the peak spectral density. This frequency modulation, included in the new code as an optional functionality, is used in simulations to motivate the experimental implementation of this transformative technique.

Terzić, B.↗

Development of an Advanced Scintillator Compton Telescope (Project Final Report)

We propose to investigate the latest scintillator detector technology as a means to design a next generation Compton telescope, one which will greatly improve on the energy resolution, background rejection, and sensitivity of the COMPTEL instrument on the Compton Gamma Ray Observatory. Our goal is to demonstrate that a scintillator-based instrument is the best way to significantly advance the field of medium-energy gamma-ray astronomy in a timely and cost effective manner. Specifically, we propose to 1) demonstrate, with a laboratory bench model, the performance that underpins a full instrument with much improved sensitivity; 2) study the performance achievable using nanocomposite scintillator materials, which promise to dramatically reduce the cost of high-performance modern scintillators; 3) use detailed Monte Carlo simulations to predict the performance of an Explorer-class mission; and 4) demonstrate, on a piggyback balloon flight making use of NASA's new shared, small-experiment balloon platform, the requisite background-reduction techniques necessary for an order-of-magnitude sensitivity improvement.

Astronomy & Astrophysics(79)↗

Measurement of Compton scattering cross section at a few GeV electron energy

Electron Compton scattering is the best known fundamental QED process, however, a precision measurement of its cross section for a beam energy above 1 GeV has been lacking up to now. An updated high precision measurement of the neutral pion lifetime via the Primakoff effect (PrimEx-II) experiment was performed in Hall B of Jefferson Lab in 2010. The experiment used small angle coherent photoproduction of π 0 ’s in the Coulomb field of a nucleus, i:e: the Primakoff effect, to determine the lifetime with a precision of less than 1:5% . It therefore requires thorough understanding of the underlying systematic uncertainties. To facilitate that data for well known electromagnetic processes were taken concurrently with the photoproduction data. This analysis pertains to measuring the Compton scattering cross section, which occurs with similar kinematics to the primary process. The combination of the well established theory for this process with large collected statistics allowed to extract this cross section with high precision in an energy region of 4-5 GeV for 12 C and 28 Si targets. The results of this analysis will be presented.

Ye, Li↗

The low Q 2 chicane and Compton polarimeter at JLEIC

The JLAB EIC (JLEIC) design includes a chicane after the interaction point to detect electron associated with production of quasi-real photon at the interaction. This chicane layout can also be used for Compton polarimetry to measure the electron beam polarization. This proceeding will present the layout of the low Q^ 2 chicane and the implementation and current R&D of a Compton polarimeter which would be located in the middle of this chicane.

Camsonne, Alexandre↗

Double Deeply Virtual Compton Scattering Opportunities At Jefferson Laboratory

Jefferson Laboratory with the current 12 GeV upgrade and a major program focused on the Generalized Parton Distributions has the opportunity to explore the Doubly Virtual Compton Scattering (DDVCS) process which would allow to probe GPDs surface for skewness di erent from the generalized bjorken variable. Such an experiment requires high luminosity because of a cross section about 100 times smaller than regular Deeply Virtual Compton Scattering. Two letter of intent were submitted to the PAC to carry out this kind of measurement. One in a modified CLAS12 setup in Hall B with a luminosity of 10^37 cm^-2.s^?1. and another one using the Solenoidal Large Intensity Device (SoLID) is a solenoidal detector equipped with Gas Elec- tron Multiplier trackers, calorimetry and Cerenkov detectors design to run with luminosity as high as a couple of 10^38 cm^-2.s^?1.

Camsonne, Alexandre↗

X-RAY AFTERGLOW OF SWIFT J1644+57: A COMPTON ECHO?

Swift, Chandra, and XMM have found a weak but nearly constant X-ray component from Swift J1644+57 that appeared at ∼500 days and was visible at least until ∼1400 days after the stellar capture, which cannot be explained by standard tidal disruption theories. We suggest that this X-ray afterglow component may result from the Thomson scattering between the primary X-rays and its surrounding plasma, i.e., a Compton echo effect. Similar phenomena have also been observed from molecular clouds in our Galactic Center, which were caused by the past activity of Srg A*. If this interpretation of Swift J1644+57 afterglow is correct, this is the first Compton Echo effect observed in the cosmological distances.

79 ASTRONOMY AND ASTROPHYSICS↗

High Optical-to-X-Ray Polarization Ratio Reveals Compton Scattering in BL Lacertae’s Jet

Blazars, supermassive black hole systems with highly relativistic jets aligned with the line of sight, are the most powerful long-lived emitters of electromagnetic emission in the Universe. We report here on a radio-to-gamma-ray multiwavelength campaign on the blazar BL Lacertae with unprecedented polarimetric coverage from radio to X-ray wavelengths. The observations caught an extraordinary event on 2023 November 10–18, when the degree of linear polarization of optical synchrotron radiation reached a record value of 47.5%. In stark contrast, the Imaging X-ray Polarimetry Explorer found that the X-ray (Compton scattering or hadron-induced) emission was polarized at less than 7.4% (3 σ confidence level). We argue here that this observational result rules out a hadronic origin of the high-energy emission and strongly favors a leptonic (Compton scattering) origin, thereby breaking the degeneracy between hadronic and leptonic emission models for BL Lacertae and demonstrating the power of multiwavelength polarimetry to address this question. Furthermore, the multiwavelength flux and polarization variability, featuring an extremely prominent rise and decay of the optical polarization degree, is interpreted for the first time by the relaxation of a magnetic “spring” embedded in the newly injected plasma. This suggests that the plasma jet can maintain a predominant toroidal magnetic field component parsecs away from the central engine.

79 ASTRONOMY AND ASTROPHYSICS↗

A Compton scatter attenuation gamma ray spectrometer

Compton attenuation technique, utilizing semiconductor sum-Compton detectors, has been proposed for gamma ray spectrometer capable of gamma spectral measurements in radition fields of 100 R/hr to one million R/hr. Spectrometer consists of two or more separate detectors, with only primary detector exposed to primary incident photon flux.

Austin, W. E.↗

Compton scatter attenuation gamma ray spectrometer

A gamma ray spectrometer is described for use in intense radiation fields such as those in the vicinity of a rocket engine exhaust. A collimated radiation beam is Compton scattered toward shielded spectrometers to reduce the energy and intensity of the radiation and is energy selective among the spectrometers. The scattering targets are changeable to control the percentage of the radiation scattered. Sum-Compton coincidence techniques are employed for data selection.

Austin, W. E.↗

On Compton models of the isotropic X-ray background.

Investigation of the compatibility of recent X-ray background energy flux observations with Compton models of the isotropic X-ray background. It is shown that the spectral shape of the X-ray flux arising from Compton scattering of fast electrons on the microwave background radiation, contrary to a recent assertion, is not inconsistent with recent observations of the isotropic X-ray background.

Brecher, K.↗

Spatial distribution of Compton-produced X-ray flux from rich and regular clusters of galaxies

The spatial distribution of radio and X-ray fluxes from rich and regular clusters of galaxies is discussed. A diffusion model is investigated in which high-energy electrons are ejected from a point source at the center of the cluster. While diffusing out, the electrons lose energy by Compton scattering with the universal blackbody photons, thus producing the X-ray emission. Traversing intracluster magnetic fields, the electrons emit synchrotron radio emission. For the Coma cluster of galaxies good agreement is found between the observed and predicted X-ray counting-rate distribution for the Compton model. From the observed radio data a value of about 3 by 10 to the -8th power gauss is deduced for the average magnetic-field strength in the central region of Coma.

Rephaeli, Y.↗

Compton scattering of microwave background radiation by gas in galaxy clusters

Based on data on the X-ray spectrum of the Coma cluster, interpreted as thermal bremsstrahlung, the expected brightness depletion from Compton scattering of the microwave background in the direction of the cluster is computed. The calculated depletion is about one-third that recently observed by Gull and Northover, and the discrepancy is discussed. In comparing the observed microwave depletion in the direction of other clusters which are X-ray sources it is found that there is no correlation with the cluster X-ray luminosity. Consequently, the microwave depletion observations cannot yet be taken as good evidence for a thermal bremsstrahlung origin for the X-ray emission. The perturbation from Compton scattering of photons on the high-frequency (Wien) tail of the blackbody distribution is computed and found to be much larger than predicted in previous calculations. In the Wien tail the effect is a relative increase in the blackbody intensity that is appreciably greater in magnitude than the depletion in the Rayleigh-Jeans domain.

Gould, R. J.↗

Compton and synchrotron processes in spherically-symmetric non-thermal sources

A framework is developed for the accurate calculation of Compton and synchrotron processes in a special class of spherically-symmetric sources. The models considered take a distribution in magnetic field values and high-energy electron density that varies smoothly from central values to values at the outer boundary of the source. Further, the assumption is made that the magnetic field has local disorder (isotropy) and the high-energy electron distribution has local isotropy. Then, in terms of parameters of the source, the synchrotron brightness distribution, total synchrotron flux, Compton-synchrotron flux, and synchrotron self-absorption turnover are all computed accurately. Results are given with a view toward application to the analysis of compact non-thermal sources.

Gould, R. J.↗