Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Commercialization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

U.S. Commercial Building Stock Analysis of COVID-19 Mitigation Strategies: Preprint

The COVID-19 pandemic highlights the importance of improving building indoor air quality to reduce occupants’ chances of contracting airborne illness. The ASHRAE Epidemic Task Force (ASHRAE-ETF) released several COVID-19 mitigation strategies at the onset of the pandemic. This study explores four of those recommendations for reducing transmission of COVID-19 inside buildings: (1) 100% outdoor air ventilation, (2) MERV-13 or better filters, (3) demand control ventilation removal, and (4) HVAC flushing mode. These recommendations were simulated and assessed using ComStock, a model of the U.S. commercial building stock. The study showed the 100% outdoor air ventilation recommendation had the largest impact on energy consumption, noncoincident peak demand, and thermostat violations. Removing demand control ventilation had the smallest national aggregate impact, installing MERV-13 filters led to slight increases in energy use and peak demand, and HVAC outdoor air flushing led to modest energy use and peak demand increases.

building energy modelling↗

Connecting Electric Vehicle Charging Infrastructure to Commercial Buildings

This factsheet from the National Renewable Energy Laboratory aims to describe how EV chargers can be connected to commercial buildings, including considerations for facility managers, and the effects that charging will have on the buildings electrical distribution system.

Better Buildings, electric vehicle charging, comme↗

Long-Term Assessment of Commercial Building Energy and Carbon Emissions in the Northwestern Region Under Future Weather Trend

The future climate significantly impacts building performance and increases uncertainties in energy simulations. A rising temperature trend is expected to heighten cooling loads during summer and result in more carbon emissions. Understanding the impact of future climate on building performance is significant for policymakers to make informed decisions. Building retrofit measures can improve building energy efficiency and reduce operational carbon emissions, yet their effects under future climate conditions have not been fully investigated so far. Thus, we proposed an assessment methodology for evaluating long-term energy consumption and operational carbon reduction potential using a building stock dataset. For this study, commercial buildings in the northwestern (NW) region were utilized to assess the impacts of future climate and building retrofit. In addition, we selected Montana with a cold and dry climate as an example to analyze and discuss the carbon emission reduction potential in buildings. The main findings are: (1) Under future climate trends, changes in energy use intensity (EUI) will fluctuate due to variations in heating and cooling degree-days (HDDs and CDDs) and increasing HDDs will lead to increasing EUI. (2) After applying annual building retrofitting, the long-term EUI reduction potential of buildings in the NW region will decrease with the increasing retrofitting degree, and the short-term EUI reduction potential will be impacted by the change of heating and cooling degree days. (3) In Montana, the long-term carbon intensity reduction potential of retrofitted buildings will decrease under future climate trends with the increasing renewable energy penetration.

building energy modeling↗

Energy Saving Estimation of ASHRAE Guideline 36 Supervisory Setpoint Reset Controls in a Commercial Large Office Building

Designing, commissioning, and retrofitting HVAC control systems for energy efficiency is crucial, but the use of ad-hoc control sequences by designers and contractors, based on scattered information, results in diverse and sub-optimal sequences. ASHRAE Guideline 36 (G36) addresses the challenge by providing standardized, rule-based HVAC control sequences that prioritize energy efficiency. However, there is limited evaluation of their energy performance at the building level, with only a few studies primarily focused on HVAC airside systems in small-to-medium-sized commercial buildings. In this study, the energy performance of ASHRAE Guideline 36 control sequences was assessed using a large office building emulator in Chicago. The emulator features a central plant system with multiple chillers and boilers as well as multiple variable air volume (VAV) systems with terminal reheat. To achieve a high-fidelity representation, we developed a Spawn-of-EnergyPlus-based model for the large office building, maintaining the DOE prototype large office building setup but substituting the HVAC system with its Modelica counterpart. This substitution ensures that the building thermal load, HVAC system's dynamics, and detailed control sequences are all accurately represented. The study involved evaluating and implementing control strategies outlined in ASHRAE Guideline 36-2021 to replace conventional controls. These strategies include the demand-based supply air temperature and duct static pressure setpoint reset and the request logic for demand-based reset of chilled/hot water supply temperature setpoints and pipe static pressure setpoints. Energy performance was evaluated under various load conditions, including cooling, heating, and transitional seasons, both for individual control strategies and in combination. The results indicate that the collective control strategies retrofit yield greater energy savings than the sum of individual strategies, highlighting the synergistic benefits of incorporating both airside and plant-side control retrofits. Additionally, energy savings of up to 41% in the heating season, 18% in the shoulder season, and 20 % in the cooling season were observed compared to baseline control while maintaining the thermal comfort level.

ASHRAE Guideline 36, Commercial buildings, Control↗

Supporting New Advanced Nuclear Technologies for Commercial-Maritime Applications

The ANS summary doesn't require an abstract, but I will produce one for the purpose of LRS: The large demand for maritime nuclear power underscores the need for experimental campaigns and modeling and simulation of new advanced reactors, which offer numerous advantages in terms of safety, efficiency, and compactness. INL, through the work conducted by NRIC and ABS, has addressed some of the technical, regulatory, and economic aspects of potential nuclear commercial maritime applications. However, on the technical side, there remain important physical phenomena, particularly for advanced reactors, that are not yet fully understood. Addressing these knowledge gaps requires a combination of experiments and advanced modeling and simulation techniques. INL possesses significant expertise in Multiphysics modeling and simulation. By collaborating with INL, the maritime nuclear sector can leverage this expertise to advance the development and deployment of innovative nuclear technologies.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Deep-Learning-Enabled Crack Detection and Analysis in Commercial Lithium-Ion Battery Cathodes

We report in Li-ion batteries, the mechanical degradation initiated by micro cracks is one of the bottlenecks for enhancing the performance. Quantifying the crack formation and evolution in complex composite electrodes can provide important insights into electrochemical behaviors under prolonged and/or aggressive cycling. However, observation and interpretation of the complicated crack patterns in battery electrodes through imaging experiments are often time-consuming, labor intensive, and subjective. Herein, a deep learning-based approach is developed to extract the crack patterns from nanoscale hard X-ray holo-tomography data of a commercial 18650-type battery cathode. Efficient and effective quantification of the damage heterogeneity with automation and statistical significance is demonstrated. The crack characteristics are further associated with the active particles’ packing densities and a potentially viable architectural design is discussed for suppressing the structural degradation in an industry-relevant battery configuration.

25 ENERGY STORAGE↗

A Perspective on Pathways Toward Commercial Sodium‐Ion Batteries

Lithium-ion batteries (LIBs) have been widely adopted in the automotive industry, with an annual global production exceeding 1000 GWh. Despite their success, the escalating demand for LIBs has created concerns on supply chain issues related to key elements, such as lithium, cobalt, and nickel. Sodium-ion batteries (SIBs) are emerging as a promising alternative due to the high abundance and low cost of sodium and other raw materials. Nevertheless, the commercialization of SIBs, particularly for grid storage and automotive applications, faces significant hurdles. This perspective article aims to identify the critical challenges in making SIBs viable from both chemical and techno-economic perspectives. First, a brief comparison of the materials chemistry, working mechanisms, and cost between mainstream LIB systems and prospective SIB systems is provided. The intrinsic challenges of SIBs regarding storage stability, capacity utilization, cycle stability, calendar life, and safe operation of cathode, electrolyte, and anode materials are discussed. Furthermore, issues related to the scalability of material production, materials engineering feasibility, and energy-dense electrode design and fabrication are illustrated. Finally, promising pathways are listed and discussed toward achieving high-energy-density, stable, cost-effective SIBs.

25 ENERGY STORAGE↗

Susceptibility to polarization type potential induced degradation in commercial bifacial p-PERC PV modules

Potential induced degradation (PID) is a reliability issue affecting photovoltaic (PV) modules, mainly when PV strings operate under high voltages in hot/humid conditions. Polarization-type PID (PID-p) has been known to decrease module performance quickly. PID-p can be reduced or recovered under the light in some cases, but this effect, as expected, would be less pronounced on the rear side of bifacial PV modules receiving lower irradiance. As bifacial PV modules are projected to dominate the PV market within the next 10 years, it is crucial to understand the PID-p issue in bifacial modules better. In this study, we performed indoor PID testing to induce PID-p on 14 commercial bifacial p-PERC modules with three different module constructions from three manufacturers. Here, four rounds (+ve and –ve polarities for front and rear sides) of PID testing are done at 25°C, 54% relative humidity (RH) for 168 h using the aluminum foil method. Each module side (front cell side and back cell side) is tested individually under both negative and positive voltage bias. The results show that the highest degradation of 32% in maximum power (Pmax) at standard test conditions (1000 W/m 2 ) and 51% at low irradiance (200 W/m 2 ) has been observed in some cases. Recovery under sunlight is also done, and outcomes show a near-complete recovery in Pmax. This study presents an extensive experimental methodology and a detailed analysis to systematically and simultaneously/sequentially evaluate multiple construction types of bifacial modules to the PID-p susceptibility and recovery.

14 SOLAR ENERGY↗

Commercialization of microcavity plasma devices and arrays: Systems for VUV photolithography and nanopatterning, disinfection of drinking water and air, and biofilm deactivation for medical therapeutics

Abstract A little more than two decades after the introduction of the first microcavity plasma devices, a growing body of commercial products based on the remarkable properties of these low‐temperature, atmospheric plasmas is now available. Following a brief review of early microplasma lamp development, this article describes microplasma‐based devices and systems currently being manufactured for applications in photolithography, photopatterning, and other nanofabrication processes, such as atomic layer deposition, spectroscopic identification and analysis of materials (including wide bandgap crystals), the disinfection of drinking water in off‐grid communities, deactivating COVID‐19 and other pathogens in air and on surfaces in public spaces, and vacuum ultraviolet lamps for driving atomic clocks. The microplasma‐based treatment of otitis media in the human ear will also be discussed.

42 ENGINEERING↗

Moisture ingress in commercial steel drums: Water content determination, diffusion modelling and predicted permeation rates

Commercial steel drums underpin the global economy, playing a pivotal role in the storage and transportation of critical materials. Transported and stored materials, such as food, chemical and nuclear waste, can be sensitive to ambient conditions, particularly moisture that can enhance negative effects such as corrosion and material degradation. Although international standards and regulations are in place for the qualification of steel drums, there are no current testing requirements, established limits or boundaries for the permeation of moisture into the drums during transportation or storage. This work aims to provide insights into the moisture ingress over time into properly sealed steel drums and provides estimated moisture ingress rates over time through extrapolation. Water vapour transmission rate (WVTR) measurements through the gasket material at 10–40°C were 0.11–2.1 g/m 2 /day resulting in a permeation activation energy of 30.2 kJ/mol. Water sorption measurements and Karl Fischer titration (KFT) on ethylene propylene diene monomer (EPDM) gasket material revealed a decrease in equilibrium moisture saturation with increasing temperature. KFT measurements also revealed the presence of moisture within the adhesive and drum wall after exposure to ambient conditions. KFT and Fourier transform infrared spectroscopy (FTIR) show that moisture will desorb from the EPDM and drum wall after exposure to desiccating conditions, although a minimal amount of moisture will remain present. When sealed to the manufacturer's recommendations, the steel drums are effective in minimizing moisture ingress. In conclusion, in sealed empty drums, moisture ingress rates for 19-L drums were 0.4–1.5 mg/day at 25°C 15% relative humidity (RH) and increased to 7.1–8.8 mg/day at 40°C 90% RH, and moisture ingress rates for 210-L drums were 2.5 and 3.5 mg/day at field deployment conditions of 15.5°C 51.5% RH and 23°C 40% RH, respectively.

42 ENGINEERING↗

Recent Developments of Commercially Fabricated Horn Antenna-Coupled Transition-Edge Sensor Bolometer Detectors for Next-Generation Cosmic Microwave Background Polarimetry Experiments

Here we report on the successful fabrication of orthomode transducer-coupled transition-edge sensor (TES) bolometer arrays for cosmic microwave background (CMB) polarimetry experiments with the superconductor electronics fabrication facility at SEEQC Inc. Commercial microfabrication foundry could provide increase in detector fabrication throughput for a next-generation CMB experiment, CMB-S4, that would deploy approximately one order of magnitude more detectors than current CMB experiments. We also developed TES bolometers with two TESs in series that have two different superconducting temperatures (Tc) using a superconducting proximity effect between niobium (Nb) and aluminum-manganese (AlMn) alloy. We will discuss the motivation, design considerations, fabrication processes, test results, and how industrial detector fabrication could be a path to fabricate hundreds of detector wafers for future CMB polarimetry experiments and other experiments that require TESs and superconducting RF circuits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In-Situ Synchrotron X-Ray Diffraction of Ultrasonic Microstructural Refinement During Solidification in a Commercial Al–Si–Mg Alloy

This study reports the first use of in-situ synchrotron X-ray diffraction (SXRD) to study the effects of ultrasonic melt processing (USMP) on phase and grain size evolution during solidification in a commercial Al–Si–Mg casting alloy. USMP is a technique that, when applied to aluminum as it solidifies, can be used to refine the local microstructure of large-scale castings. Analysis of the in-situ SXRD data to estimate the average grain size of primary α-Al grains during USMP demonstrates that USMP slows the growth rate of α-Al grains and reduces grain size by 36 pct. Furthermore, there is also evidence that USMP causes the primary α-Al grains to move relative to the X-ray beam; such motion increases the probability of primary α-Al grains colliding and fragmenting. This movement becomes constrained at the onset of the Al–Si binary eutectic, suggesting that USMP ceases to effectively refine the microstructure once the Al–Si binary eutectic begins to form. Complementary laboratory-scale X-ray diffraction (XRD) data were used to correlate the lattice parameters of the α-Al and Si (D-A4) phases with temperature to estimate cooling rate during solidification. Thus, this study can guide the design of novel castings with spatially distributed fine-grained regions produced using local ultrasonic processing.

Aluminum Alloys↗

Comparative performance and technoeconomic analyses of two microalgae harvesting systems evaluated at a commercially relevant scale

Using a commercially scalable system designed for processing thousands of liters a day, here we evaluated the factors that affected the performance, energy consumption and capital/operating costs of both flocculation-based and filtration-based algal harvesting systems over a 16 month period. Coagulation efficiency was the primary driver of harvest efficiency in the flocculation-based method, while cell lysis was important for the filtration-based method. Culture (algae) age differentially influenced harvest efficiency through changes in cell fragility and stickiness. The average energy consumption of the flocculation-based method was 0.389 kWh/m 3 , while that for the filtration-based method was 4.343 kWh/m 3 . The average harvesting cost of the filtration-based method was 5.35 $\$$/m 3 , while for flocculation-based method it was 4.52 $\$$/m 3 . The concentration factor of filtration-based and flocculation-based method were 770–1086 and 407–448, respectively. For both harvesting methods, labor costs dominated and ranged from 55.84%–67.94% of total cost. Further system automation is a potential method to lower the harvesting cost. The filtration-based harvesting method could produce a better quality of algal biomass with higher concentration factors and less ash content, but needed more energy input, as compared with a flocculation-based method. This study highlights the importance of algal culture status to successful harvesting, and it also provides insight into developing more efficient harvesting technology with lower energy and capital cost.

59 BASIC BIOLOGICAL SCIENCES↗

Development of integrated screening, cultivar optimization, and verification research (DISCOVR): A coordinated research-driven approach to improve microalgal productivity, composition, and culture stability for commercially viable biofuels production

To address major knowledge gaps and barriers to the commercial development of algal biomass for biofuels and co-products, a collaborative consortium, Development of Integrated Screening, Cultivar Optimization, and Verification Research (DISCOVR), was established in 2016. Funded by the U.S. Department of Energy (DOE) Bioenergy Technologies Office (BETO), this consortium constitutes a partnership between four DOE national laboratories - Pacific Northwest National Laboratory (PNNL), Los Alamos National Laboratory (LANL), the National Renewable Energy Laboratory (NREL), and Sandia National Laboratories (SNL) - and the Arizona Center for Algae Technology and Innovation (AzCATI) at Arizona State University. To address the barriers of strain selection for achieving high seasonal productivities with a suitable composition and culture resilience, a tiered strain down-selection pipeline is implemented. At Tier I, the temperature and salinity tolerance of strains is determined in flask cultures; at Tier II, the areal biomass productivity and composition is determined in climate-simulation photobioreactors; at Tier III, the productivity and culture stability are determined in outdoor raceways. The top performing strains move forward to long-term testing at the algae testbed site at AzCATI to generate annual biomass productivity data. Concurrent to the strain down-selection in the DISCOVR pipeline, hypotheses for increasing biomass productivity, shifting biomass composition to enhance intrinsic value, and improving culture stability and resistance to pests are also tested. Techno-economic analyses are carried out to determine whether promising findings from laboratory studies or proposed modifications in outdoor pond cultivation conditions translate into reductions in the minimum biomass selling price (MBSP). Notably, in the three years following the launch of DISCOVR, annual biomass productivity has increased from 11.7 to 17.6 g m -2 day -1 , resulting in an MBSP decrease from 824 to 611 $ ton -1 .

09 BIOMASS FUELS↗

Adopting occupancy-based HVAC controls in commercial building energy codes: Analysis of cost-effectiveness and decarbonization potential

Recent research has shown the energy-saving potential of occupancy-based HVAC controls (OBCs) in commercial buildings. However, building energy codes have not fully adopted this technology. This study aims to evaluate the cost-effectiveness and decarbonization benefits of OBCs and provide guidance for integrating occupancy sensors into building energy code development. To this end, a parametric simulation using EnergyPlus and a nationwide cost-effectiveness analysis are carried out considering three building types and 40 representative cities in the U.S. Here, the findings reveal that the current cost-effectiveness performance of OBCs is limited due to the high cost of occupancy sensors. However, incorporating the societal cost of carbon factor in future energy and environmental policy could greatly enhance the actual cost-effectiveness performance. Besides, a reduction in the cost of occupancy sensors to approximately 60% of the current price level could also greatly shorten the discounted payback period of OBCs. Additionally, OBCs demonstrate significant potential in building decarbonization, with potential CO 2 emissions savings of more than 5.56 million metric tons across the three building types and 40 selected cities. Finally, policy implications are provided to guide the incorporation of occupancy-based HVAC controls in future energy codes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Decarbonization of heat pump dual fuel systems using a practical model predictive control: Field demonstration in a small commercial building

In the transition from fossil fuel to electrified heating, a concerning trend is emerging in certain regions of the US. Owners of buildings with gas-based systems leave them in place after adding heat pumps (HPs). Existing control solutions for these hybrid (dual fuel) systems are rudimentary and fall short of realizing the full carbon reduction potential of these systems. Model predictive control (MPC) is often regarded as the benchmark for achieving optimal control in integrated systems. However, in the case of small-medium commercial buildings (SMCBs), the control and communication infrastructure required to facilitate the implementation of such advanced controls is often lacking. This paper presents a field implementation of easy-to-deploy MPC for a dual fuel heating system consisting of HPs and a gas-fired furnace (GF) for SMCBs. The control system is deployed on an open-source middleware platform and utilizes low-cost sensor devices to be used for real SMCBs without major retrofits. Here, we demonstrated this MPC in a real office building with 5 HPs and 1 GF for 2 months. The test results showed that MPC reduced 27% of cost while completely eliminating GF usage by shifting 23% of the thermal load from occupied-peak time to non-occupied-non-peak times.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Regional difference and related cooling electricity savings of air pollutant affected natural ventilation in commercial buildings across the US

Maintaining indoor air pollutants under acceptable levels is significant to protect occupants from exposure to excessive air pollutants in natural ventilation. In this paper, using the representative air pollutant concentration data, we present the natural ventilation usability with associated cooling energy saving potentials in different location settings (urban and city center, suburban and rural) of the US under the influence of local weather conditions and major outdoor air pollutants, i.e. PM2.5, PM10 and ozone. It is found that the impacts of air pollutants on natural ventilation are usually higher in urban/suburban areas than rural areas (up to 25% difference) with the PM2.5 being the most significant outdoor air pollutant affecting natural ventilation usage. Furthermore, ozone could become increasingly influential on natural ventilation as moving from urban to suburban/rural areas. As to the cooling energy saving considering the impacts of outdoor air pollutants, natural ventilation is estimated to save approximately 10%–40% cooling energy (800–2600 kWh per small commercial building) annually in different location settings of investigated areas across the US. The following economic analysis demonstrates that these electricity savings lead to approximately 80–540 dollars annual savings of building operation cost per building. If the time of use rate is adopted, these cost savings could further increase by approximately 20% (Los Angeles) to more than 50% (Albuquerque) depending on different rate structures, which further demonstrates the potential of adopting natural ventilation as a sustainability measurement with benefits for building owners without compromising occupants health.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗