Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Collimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

How to Turn Jets into Cylinders near Supermassive Black Holes in 3D General Relativistic Magnetohydrodynamic Simulations

Abstract Accreting supermassive black holes (SMBHs) produce highly magnetized relativistic jets that tend to collimate gradually as they propagate outward. However, recent radio interferometric observations of the 3C 84 galaxy reveal a stunning, cylindrical jet already at several hundred SMBH gravitational radii,r≳ 350r g . We explore how such extreme collimation emerges via a suite of 3D general relativistic magnetohydrodynamic simulations. We consider an SMBH surrounded by a magnetized torus immersed in a constant-density ambient medium that starts at the edge of the SMBH sphere of influence, chosen to be much larger than the SMBH gravitational radius,r B = 10 3 r g . We find that radiatively inefficient accretion flows (e.g., M87) produce winds that collimate the jets into parabolas near the black hole. After the disk winds stop collimating the jets atr≲r B , they turn conical. Once outsider B , the jets run into the ambient medium and form backflows that collimate the jets into cylinders some distance beyondr B . Interestingly, for radiatively efficient accretion, as in 3C 84, the radiative cooling saps the energy out of the disk winds; at early times, they cannot efficiently collimate the jets, which skip the initial parabolic collimation stage, start out conical near the SMBH, and turn into cylinders already atr≃ 300r g , as observed in 3C 84. Over time, the jet power remains approximately constant, whereas the mass accretion rate increases; the winds grow in strength and start to collimate the jets, which become quasi-parabolic near the base, and the transition point to a nearly cylindrical jet profile moves outward while remaining insider B .

Astronomy & Astrophysics↗

Radiography by selective detection of scatter field velocity components

A reconfigurable collimated radiation detector, system and related method includes at least one collimated radiation detector. The detector has an adjustable collimator assembly including at least one feature, such as a fin, optically coupled thereto. Adjustments to the adjustable collimator selects particular directions of travel of scattered radiation emitted from an irradiated object which reach the detector. The collimated detector is preferably a collimated detector array, where the collimators are independently adjustable. The independent motion capability provides the capability to focus the image by selection of the desired scatter field components. When an array of reconfigurable collimated detectors is provided, separate image data can be obtained from each of the detectors and the respective images cross-correlated and combined to form an enhanced image.

Jacobs, Alan M.↗

Bayesian optimization to design a novel x-ray shaping device

In radiation therapy, x-ray dose must be precisely sculpted to the tumor, while simultaneously avoiding surrounding organs at risk. This requires modulation of x-ray intensity in space and/or time. Typically, this is achieved using a multi leaf collimator (MLC) - a complex mechatronic device comprising over one hundred individually powered tungsten ‘leaves’ that move in or out of the radiation field as required. Here, an all-electronic x-ray collimation concept with no moving parts is presented, termed “SPHINX”: Scanning Pencil-beam High-speed Intensity-modulated X-ray source. SPHINX utilizes a spatially distributed bremsstrahlung target and collimator array in conjunction with magnetic scanning of a high energy electron beam to generate a plurality of small x-ray “beamlets.” A simulation framework was developed in Topas Monte Carlo incorporating a phase space electron source, transport through user defined magnetic fields, bremsstrahlung x-ray production, transport through a SPHINX collimator, and dose in water. This framework was completely parametric, meaning a simulation could be built and run for any supplied geometric parameters. This functionality was coupled with Bayesian optimization to find the best parameter set based on an objective function which included terms to maximize dose rate for a user defined beamlet width while constraining inter-channel cross talk and electron contamination. Designs for beamlet widths of 5, 7, and 10 mm 2 were generated. Each optimization was run for 300 iterations and took approximately 40 h on a 24-core computer. For the optimized 7-mm model, a simulation of all beamlets in water was carried out including a linear scanning magnet calibration simulation. Finally, a back-of-envelope dose rate formalism was developed and used to estimate dose rate under various conditions. The optimized 5–, 7–, and 10-mm models had beamlet widths of 5.1 , 7.2 , and 10.1 mm 2 and dose rates of 3574, 6351, and 10 015 Gy/C, respectively. The reduction in dose rate for smaller beamlet widths is a result of both increased collimation and source occlusion. For the simulation of all beamlets in water, the scanning magnet calibration reduced the offset between the collimator channels and beam centroids from 2.9 ±1.9 mm to 0.01 ±0.03 mm. A slight reduction in dose rate of approximately 2% per degree of scanning angle was observed. Based on a back-of-envelope dose rate formalism, SPHINX in conjunction with next-generation linear accelerators has the potential to achieve substantially higher dose rates than conventional MLC-based delivery, with delivery of an intensity modulated 100 x 100 mm 2 field achievable in 0.9 to 10.6 s depending on the beamlet widths used. Bayesian optimization was coupled with Monte Carlo modeling to generate SPHINX geometries for various beamlet widths. A complete Monte Carlo simulation for one of these designs was developed, including electron beam transport of all beamlets through scanning magnets, x-ray production and collimation, and dose in water. These results demonstrate that SPHINX is a promising candidate for sculpting radiation dose with no moving parts, and has the potential to vastly improve both the speed and robustness of radiotherapy delivery. A multi-beam SPHINX system may be a candidate for delivering magavoltage FLASH RT in humans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Parametric study and optimization trends for the Von-Kármán-sodium dynamo experiment

In this paper, we present magneto-hydrodynamic simulations of liquid sodium flow performed with the PLUTO compressible MHD code. We investigated the influence of the remanent magnetic field orientation and intensity, the impinging velocity field due to Ekman pumping as well as the impeller dimensions on the magnetic field collimation by helical flows in-between the impeller blades. For a simplified Cartesian geometry, we model the flow dynamics of a multi-blade impeller inspired by the Von-Kármán-Sodium experiment. This study shows that a remanent magnetic field oriented in the toroidal direction is the less efficient configuration to collimate the magnetic field, although if the radial or vertical components are not negligible, the collimation is significantly improved. As the intensity of the remanent magnetic field increases, the system magnetic energy becomes larger, but the magnetic field collimation efficiency remains the same, so the gain of magnetic energy is smaller as the remanent magnetic field intensity increases. The magnetic field collimation is modified if the impinging velocity field changes: the collimation is weaker if the impinging velocity increases from Γ = 0.8 to 0.9 and slightly larger if the impinging velocity decreases from Γ = 0.8 to 0.7. The analysis of the impeller dimensions points out that the most efficient configuration to collimate the magnetic field requires a ratio between the impeller blade height and the base longitude between 0.375 and 0.5. The largest enhancement of the hypothetical α 2 dynamo loop, compared to the hypothetical Ω-α dynamo loop, is observed for the model that mimics the TM 73 impeller configuration rotating in the unscooping direction with a remanent magnetic field of 10 –3 T orientated in the radial or vertical direction. Finally, the optimization trends obtained in the parametric analysis are also confirmed by simulations with a higher resolution and turbulence degree.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gamma Spectrometry Code Rodeo for Uranium Enrichment—FY 2021 Report

In FY22, the participating Department of Energy (DOE) laboratories continued the work on the project “Gamma Spectrometry Code Rodeo for Uranium Enrichment”. Oak Ridge National Laboratory (ORNL) and Lawrence Livermore National Laboratory (LLNL) continued their efforts to acquire spectra using uranium sources. A collimator (with side and back shields) was custom designed and constructed at ORNL. Spectra were acquired at ORNL using the uranium enrichment standards supplied by New Brunswick Laboratory (NBL) and the collimated M400 detector. Spectra were also acquired using steel absorbers of different thickness placed between the source and the collimated M400 detector. The plan was to ship the collimator to LLNL so that spectra could be acquired using the LLNL detector in collimated geometries. This activity was suspended since problems were noticed with the performance of the LLNL M400 detector. Also, it was brought to light to the project team that some of the aspects of the M400 detector had been updated by the vendor H3D in response to requests by the IAEA. In February 2021, the ORNL and LLNL M400 detectors were returned to the H3D factory in order to resolve the problems with the LLNL detector and to update ORNL and LLNL detectors to the same configuration as the M400 supplied to the IAEA. H3D repaired the LLNL M400 and performed the IAEA updates on both the ORNL and LLNL detectors. ORNL and LLNL received the detectors in April 2021. Data acquisition was continued using the upgraded detectors. ORNL re-collected the spectra using point sources and the NBL standards in uncollimated and collimated geometries. The collimator was shipped from ORNL to LLNL. Spectra were acquired at LLNL through Q4 of FY22. When the ORNL spectra were examined closely, it became apparent that there were spurious artifacts present in some of the spectra. This rendered suspect the ORNL spectra collected in June/July 2021 time frame. ORNL contacted H3D and per H3D’s advice, the M400 detector was returned to H3D for repairs in mid-August 2021. H3D diagnosed the problem and established that the root cause was the extra tight packaging that created a strain on the CZT crystals, causing one of them to break down. The repaired M400 was returned to ORNL in early September 2021. ORNL re-started data acquisition for the third time. Data was continued to be acquired at ORNL and LLNL through September 2021. The ORNL and LLNL data will be shared with the principal investigators from the analyzing laboratories. The GADRAS code and FRAM have been developed to have the capability to analyze the M400 spectra. Good quality spectra from FY21 have been analyzed using modified versions of GADRAS and FRAM. The spectra have also been analyzed using the GEM code. The analysis results from GADRAS, FRAM and GEM codes are presented and discussed in this report. Some preliminary results from FRAM and GEM analysis were presented in February 2021 at the U-Pu Isotopics Workshop sponsored by the IAEA. CZTU code is being modified to analyze M400 spectra. Data collection, code development and analysis will be continued in FY22 as per the FY22 Project Work Plan (PWP).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Motion-Base Simulator Evaluation of an Aircraft Using an External Vision System

Twelve air transport-rated pilots participated as subjects in a motion-base simulation experiment to evaluate the use of eXternal Vision Systems (XVS) as enabling technologies for future supersonic aircraft without forward facing windows. Three head-up flight display concepts were evaluated -a monochromatic, collimated Head-up Display (HUD) and a color, non-collimated XVS display with a field-of-view (FOV) equal to and also, one significantly larger than the collimated HUD. Approach, landing, departure, and surface operations were conducted. Additionally, the apparent angle-of-attack (AOA) was varied (high/low) to investigate the vertical field-of-view display requirements and peripheral, side window visibility was experimentally varied. The data showed that lateral approach tracking performance and lateral landing position were excellent regardless of AOA, display FOV, display collimation or whether peripheral cues were present. However, the data showed glide slope approach tracking appears to be affected by display size (i.e., FOV) and collimation. The monochrome, collimated HUD and color, uncollimated XVS with Full FOV display had (statistically equivalent) glide path performance improvements over the XVS with HUD FOV display. Approach path performance results indicated that collimation may not be a requirement for an XVS display if the XVS display is large enough and employs color. Subjective assessments of mental workload and situation awareness also indicated that an uncollimated XVS display may be feasible. Motion cueing appears to have improved localizer tracking and touchdown sink rate across all displays.

Kramer, Lynda J.↗

Pixelated gamma detector

A pixelated gamma detector includes a scintillator column assembly having scintillator crystals and optical transparent elements alternating along a longitudinal axis, a collimator assembly having longitudinal walls separated by collimator septum, the collimator septum spaced apart to form collimator channels, the scintillator column assembly positioned adjacent to the collimator assembly so that the respective ones of the scintillator crystal are positioned adjacent to respective ones of the collimator channels, the respective ones of the optical transparent element are positioned adjacent to respective ones of the collimator septum, and a first photosensor and a second photosensor, the first and the second photosensor each connected to an opposing end of the scintillator column assembly. A system and a method for inspecting and/or detecting defects in an interior of an object are also disclosed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Machine Protection Studies of Fast Instability-Driven Beam Losses in the EIC Electron Storage Ring

Fast transverse beam instabilities represent one of the most challenging protection scenarios for the Electron-Ion Collider (EIC) electron storage ring (ESR). Coherent betatron oscillations driven by collective effects can grow rapidly and lead to substantial beam losses within only a few tens of turns, posing a threat to collimators, superconducting (SC) magnets, cryogenic systems, and detector components. A dedicated simulation framework based on distributed transverse excitations was developed to evaluate instability-driven beam losses in the ESR. A conservative instability rise time on the order of 10 turns was used to define a bounding protection scenario. Simulations show that the original two-collimator configuration is insufficient to localize losses under all operating conditions, whereas an optimized four-collimator configuration reduces loss leakage into protected regions by more than two orders of magnitude. Nevertheless, the most severe instability scenarios produce catastrophic beam impacts, with nearly half of the stored beam being intercepted by the collimators within a single turn, exceeding the preliminary estimated survivability limits of the baseline collimator design. The results demonstrate that collimation alone is insufficient to guarantee safe ESR operation and must be complemented by a fast machine-protection system. Dedicated turn-by-turn beam-position monitors and fast beam-loss monitors provide sufficient advance warning to detect instability growth and initiate a beam abort before equipment-damaging loss levels are reached. These findings establish quantitative requirements for the ESR machine-protection architecture and support the implementation of a multilayer protection strategy for both accelerator and detector systems.

43 PARTICLE ACCELERATORS↗

Detection of Fuel Pin Diversion via Fast Neutron Emission Tomography

Oak Ridge National Laboratory is developing a new capability to perform passive fast neutron emission tomography of spent nuclear fuel. The goal of this capability is to detect vacancies or substitutions of individual fuel pins in spent nuclear fuel assemblies for international safeguards applications, such as verifying the integrity of an assembly prior to transfer to “difficult to access” storage. Emission tomography uses collimation to isolate activity along “lines of response” through an object. By combining many collimated views through an object, the neutron emission from each fuel pin can be mathematically extracted and an image of the fuel assembly can be constructed. However, performing fast-neutron imaging is challenging for the very reason that it is desirable, namely, that fast neutrons penetrate a good deal of shielding and are consequently difficult to collimate and measure with high resolution. For spent fuel, additional challenges include the modest neutron source strength and the overwhelming gamma-ray emissions. While the International Atomic Energy Agency (IAEA) is presently investigating the use of passive gamma emission tomography for the same application, it is useful to investigate neutron emission tomography because fast neutrons better penetrate larger fuel assemblies and because fast neutrons (originating primarily from curium-244 which is mainly produced at the end of the exposure cycle) may be sensitive to replacement fuel pins that are subsequently irradiated. In the present work, we present a novel collimator concept that will enable rapid transaxial tomographic imaging of spent nuclear fuel using the spontaneous fast neutron emissions from the fuel. Initial design simulations of an imager based on this collimator indicate sufficient resolution to identify individual fuel pins. Employing such a collimator, the resulting imager can be sufficiently compact, efficient, and radiation resistant to make fast neutron emission imaging practical.

Iyengar, Anagha↗

Phase Trombone Design in the Beam Transfer line for the Project PIP-II at Fermilab

PIP-II beam transfer line (BTL) to transport the beam from PIP-II Linac to the Booster ring at Fermilab. One crucial aspect of the BTL design involved the implementation of collimators. These collimators play a vital role in removing large amplitude particles from the beamline that might otherwise miss the horizontal and vertical edge of the foil at the point of the Booster injection. To ensure the effectiveness of these collimators, simulation was conducted to determine their optical placement within the BTL. The simulation revealed that the precise control of accumulated phase advances between the collimators and the foil was crucial. To achieve this control, a phase trombone is needed within the BTL. The phase trombone serves as an adjustment mechanism, allowing for the fine-tuning of the phase advance between the collimators and the foil, thus optimizing the performance of the collimation process. This paper discusses and presents the details of the design and implementation of the phase trombone within the PIP-II BTL.

43 PARTICLE ACCELERATORS↗

Optical design for the single crystal neutron diffractometer Pioneer

Pioneer is a single-crystal neutron diffractometer optimized for small-volume samples and weak signals at the Second Target Station at Oak Ridge National Laboratory. This paper presents the preliminary optical design progress, focusing on the rationale behind key design choices. It covers the T 0 and bandwidth disk choppers, guide and beam control system, incident-beam polarizer, scattering beam collimators, and additional strategies. The chopper locations are selected to maximize neutron transport while taking advantage of standardized shielding structures. To accommodate the maintenance shield, operational shutter, and polarizing V-cavity, the guide design includes significant gaps. When these optical components are moved out of the beam path, oversized collimators, rather than guides, will be translated in. Pioneer will utilize slit packages to control beam size and divergence and a translatable polarizing V-cavity. Absorbing panels are strategically placed near the end station to minimize background. An oscillating radial collimator, operating in a shift mode, will be used with the vertical cylindrical detector, while a fixed multi-cone collimator will be used with the bottom flat detector. In conclusion, these collimators will enable the detection of weak signals when complex sample environments are used.

47 OTHER INSTRUMENTATION↗

Effects of diffraction in multiple-grid telescopes for X-ray astronomy

Diffraction effects in modern designs for grid collimator telescopes (assumed to have roughly a 100-micron grid period) are apparent at wavelengths longer than 1 A and are dominant at wavelengths longer than 10 A. In collimators with many grids spaced far apart the effects of diffracation are to reduce strongly the peak transmission of the collimator at longer wavelengths and to broaden it by about the amount expected from Fraunhofer diffraction through a slit the size of the grid openings. Comparisons between two-collimator measurements and the present calculations show reasonable agreement; it is therefore concluded that the present single-collimator calculation gives a good representation of their diffraction-limited angular response.

Lindsey, C. A.↗

A compact density condensation around L1551-IRS 5: 2.7mm continuum observations with 4" resolution

The dark cloud L1551 contains the best known examples of bipolar molecular outflow. Such outflows are assumed to be driven by winds from young stars embedded in a cloud but the mechanism for collimation of the outflows is still in doubt, though it has been much debated. Among the possibilities put forth to date are intrinsically anisotropic stellar winds, isotropic stellar winds collimated by interstellar toroidal shaped clouds on the order of 10(17) cm in size, or circumstellar disks of order 10(15) cm in size. Because the outflow in L1551 as revealed by the Very Large Array (VLA) cm continuum observations is collimated even at the arc second level it seems as though the stellar wind powering the outflow must either be initially anisotropic or be collimated by something very close to the star, such as a circumstellar disk. We have observed L1551 in the continuum at 2.7 mm with the OVRO millimeter-wave interferometer in the winter of 1983-4 and again, more extensively, in 1985-6. The resulting map shows for the first time direct evidence for a density condensation capable of collimating an initially isotropic flow from IRS 5. This map made from data taken in 1985-6 with projected baselines up to 100 m in length (37k lambda). It has been cleaned and reconstructed with a 4'' gaussian beam. It shows a nearly unresolved source with a suggestion of extension at the 3'' level (assuming a gaussian source shape). The integrated flux density in this map is 170 mJy. A composite spectrum of L1551 is presented which shows that the flux at 2.7 mm is due to the thermal radiation from dust that is also seen at shorter wavelengths. Very little of it can be due to the continuation of the nearly flat cm wavelength spectrum which is assumed to be from thermal bremsstrahlung radiation. The map and spectrum provide strong constraints on the size, temperature, and optical depth of the density condensation surrounding IRS 5.

Keene, J.↗

Method and apparatus for a multibeam beacon laser assembly for optical communications

An optical beacon is comprised of a telescope having a primary focal plane or Coud? focal plane, a plurality of fiber coupled laser sources for generating a plurality of beams, a collimator for collimating the plurality of beams, and optics for combining and focusing the plurality of collimated beams onto the primary or Coud? focal plane of the telescope. The telescope propagates the optical beacon, which is arranged into a ring of incoherent plurality of collimated beams. The apparatus further comprises fiber splitters coupled to each laser source to provide at least eight beams from at least four laser sources. The optics comprises a prism assembly, a combiner lens, a focusing lens and a field lens for focusing the plurality of collimated beams onto the primary focal plane or Coud? focal plane of the telescope.

Biswas, Abhijit↗

Microfocus/Polycapillary-Optic Crystallographic X-Ray System

A system that generates an intense, nearly collimated, nearly monochromatic, small-diameter x-ray beam has been developed for use in macromolecular crystallography. A conventional x-ray system for macromolecular crystallography includes a rotating-anode x-ray source, which is massive (.500 kg), large (approximately 2 by 2 by 1 m), and power-hungry (between 2 and 18 kW). In contrast, the present system generates a beam of the required brightness from a microfocus source, which is small and light enough to be mounted on a laboratory bench, and operates at a power level of only tens of watts. The figure schematically depicts the system as configured for observing x-ray diffraction from a macromolecular crystal. In addition to the microfocus x-ray source, the system includes a polycapillary optic . a monolithic block (typically a bundle of fused glass tubes) that contains thousands of straight or gently curved capillary channels, along which x-rays propagate with multiple reflections. This particular polycapillary optic is configured to act as a collimator; the x-ray beam that emerges from its output face consists of quasi-parallel subbeams with a small angular divergence and a diameter comparable to the size of a crystal to be studied. The gap between the microfocus x-ray source and the input face of the polycapillary optic is chosen consistently with the focal length of the polycapillary optic and the need to maximize the solid angle subtended by the optic in order to maximize the collimated x-ray flux. The spectrum from the source contains a significant component of Cu K (photon energy is 8.08 keV) radiation. The beam is monochromatized (for Cu K ) by a nickel filter 10 m thick. In a test, this system was operated at a power of 40 W (current of 897 A at an accelerating potential of 45 kV), with an anode x-ray spot size of 41+/-2 microns. Also tested, in order to provide a standard for comparison, was a commercial rotating-anode x-ray crystallographic system with a pyrolytic graphite monochromator and a 250-micron pinhole collimator, operating at a power of 3.15 kW (current of 70 mA at an accelerating potential of 45 kV). The flux of collimated Cu K radiation in this system was found to be approximately 16 times that in the rotatinganode system. Data on x-ray diffraction from crystals of tetragonal form of lysozyme (protein) in this system were found to be of high quality and to be reducible by use of standard crystallographic software.

Joy, Marshall↗

Background and Lunar Neutron Populations Detected by LEND and Average Concentration of Near-Surface Hydrogen near the Moon's Poles

Neutron flux measurements by the Lunar Exploration Neutron Detector (LEND) on the Lunar Reconnaissance Orbiter (LRO) enable quantifying hydrogen-bearing volatiles in the lunar surface from orbit. Accurately determining hydrogen abundance requires discriminating between the instrument background detection rate and the population of lunar-sourced neutrons that are sensitive to surficial hydrogen. We have investigated the detection rate for lunar and non-lunar (spacecraft-sourced) neutrons in LEND by modeling maps of measured count rate in three LEND detector systems using linear combinations of maps compiled from LEND detectors and from the Lunar Prospector Neutron Spectrometer. We find that 30% of the global-average 24.926 +/- 0.020 neutron counts per second (cps) detected by the LEND STN3 thermal-energy neutron sensor are lunar-sourced neutrons in the thermal energy range (E < 0.4 eV), 65% are lunar-sourced neutrons in the epithermal and fast energy range (E > 0.4 eV), and 5% are from spacecraft-sourced background signal. In the SETN epithermal neutron detector, 90% of the 10.622 +/- 0.002 neutron detections per second are consistent with a lunar source of epithermal and fast neutrons combined (E > 0.4 eV), with 3% due to lunar-sourced thermal neutron leakage into the detector (E < 0.4 eV), and background signal accounting for 7% of total detections. Background signal due to spacecraft-derived neutrons is substantial in the CSETN collimated detector system, accounting for 57% of the global average detection rate of 5.082 +/- 0.001 cps, greater than the 48% estimated from cruise-phase data. Lunar-sourced epithermal and fast neutrons account for 43% of detected neutrons, including neutrons in collimation as well as neutrons that penetrate the collimator wall to reach the detector. We estimate a lower limit of 17% of lunar-sourced neutrons detected by CSETN are epithermal neutrons in collimation (0.37 cps), with an upper limit estimate of 54 +/- 11% of lunar-sourced neutrons received in collimation, or 1.2 +/- 0.2 cps global average. The pole-to-equator contrast ratio in epithermal and high-energy epithermal neutron flux indicates that the average concentration of hydrogen in the polar regolith above 80deg north or south latitude is ∼105 ppmw (parts per million by weight), or 0.095 +/- 0.01 wt% water-equivalent hydrogen. Above 88deg north or south, the concentration increases to ∼140 ppmw, or 0.13 +/- 0.02 wt% water-equivalent hydrogen. The similar pattern of neutron flux suppression at both poles suggests that hydrogen concentration generally increases nearer the pole and is not closely associated with a specific feature such as Shackleton Crater at the lunar south pole that has no northern counterpart. Epithermal neutron flux decreases with increasing latitude outside the polar regions, consistent with surface hydration that increases with latitude if that hydration extends to ∼13-40 cm into the surface.

T A Livengood↗

Background and Lunar Neutron Populations Detected by LEND and Average Concentration of Near-Surface Hydrogen near the Moon's Poles

Neutron flux measurements by the Lunar Exploration Neutron Detector (LEND) on the Lunar Reconnaissance Orbiter (LRO) enable quantifying hydrogen-bearing volatiles in the lunar surface from orbit. Accurately determining hydrogen abundance requires discriminating between the instrument background detection rate and the population of lunar-sourced neutrons that are sensitive to surficial hydrogen. We have investigated the detection rate for lunar and non-lunar (spacecraft-sourced) neutrons in LEND by modeling maps of measured count rate in three LEND detector systems using linear combinations of maps compiled from LEND detectors and from the Lunar Prospector Neutron Spectrometer. We find that 30% of the global-average 24.926 0.020 neutron counts per second (cps) detected by the LEND STN3 thermal-energy neutron sensor are lunar-sourced neutrons in the thermal energy range (E < 0.4 eV), 65% are lunar-sourced neutrons in the epithermal and fast energy range (E > 0.4 eV), and 5% are from spacecraft-sourced background signal. In the SETN epithermal neutron detector, 90% of the 10.622 0.002 neutron detections per second are consistent with a lunar source of epithermal and fast neutrons combined (E > 0.4 eV), with 3% due to lunar-sourced thermal neutron leakage into the detector (E < 0.4 eV), and background signal accounting for 7% of total detections. Background signal due to spacecraft-derived neutrons is substantial in the CSETN collimated detector system, accounting for 57% of the global average detection rate of 5.082 0.001 cps, greater than the 48% estimated from cruise-phase data. Lunar-sourced epithermal and fast neutrons account for 43% of detected neutrons, including neutrons in collimation as well as neutrons that penetrate the collimator wall to reach the detector. We estimate a lower limit of 17% of lunar-sourced neutrons detected by CSETN are epithermal neutrons in collimation (0.37 cps), with an upper limit estimate of 54 11% of lunar-sourced neutrons received in collimation, or 1.2 0.2 cps global average. The pole-to-equator contrast ratio inepithermal and high-energy epithermal neutron flux indicates that the average concentration of hydrogen in the polar regolith above 80 north or south latitude is ~105 ppmw (parts per million by weight), or 0.095 0.01 wt% water-equivalent hydrogen. Above 88 north or south, the concentration increases to ~140 ppmw, or 0.13 0.02 wt% water-equivalent hydrogen. The similar pattern of neutron flux suppression at both poles suggests that hydrogen concentration generally increases nearer the pole and is not closely associated with a specific feature such as Shackleton Crater at the lunar south pole that has no northern counterpart. Epithermal neutron flux decreases with increasing latitude outside the polar regions, consistent with surface hydration that increases with latitude if that hydration extends to ~13-40 cm into the surface.

Livengood, Timothy A.↗

Commissioning of small field size radiosurgery cones in a 6-MV flattening filter-free beam

This study aimed to describe the commissioning of small field size radiosurgery cones in a 6-MV flattening filter free (FFF) beam and report our measured values. Four radiosurgery cones of diameters 5, 10, 12.5, and 15 mm supplied by Elekta Medical were commissioned in a 6-MV FFF beam from an Elekta Versa linear accelerator. The extraction of a reference signal for measuring small fields in scanning mode is challenging. A transmission chamber was attached to the lower part of the collimators and used for percentage depth dose (PDD) and profile measurements in scanning mode with a stereotactic diode. Tissue-maximum ratios (TMR) and output factors (OF) for all collimators were measured with a stereotactic diode (IBA). TMR and the OF for the largest collimator were also acquired on a polystyrene phantom with a microionization chamber of 0.016 cm{sup 3} volume (PTW Freiburg PinPoint 3D). Measured TMR with diode and PinPoint microionization chamber agreed very well with differences smaller than 1% for depths below 20 cm, except for the smaller collimator, for which differences were always smaller than 2%. Calculated TMR were significantly different (up to 7%) from measured TMR. OF measured with diode and chamber showed a difference of 3.5%. The use of a transmission chamber allowed the measurement of the small-field dosimetric properties with a simple setup. The commissioning of radiosurgery cones in FFF beams has been performed with essentially the same procedures and recommended detectors used with flattened beams. Good agreement was found between TMR measurements acquired with the IBA stereotactic diode and the PinPoint 3D microionization chamber. The transmission chamber overcomes the problem of extracting a reference signal and is of great help for small-field commissioning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗