Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Charge coupled devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Unraveling Fano noise and the partial-charge-collection effect in x-ray spectra below 1 keV

Fano noise, readout noise, and the partial-charge-collection (PCC) effect collectively contribute to the degradation of energy spectra in charge-coupled device (CCD) measurements, especially at low energies. Here, in this work, the x rays produced by the fluorescence of fluorine (677 eV) and aluminum (1486 eV) were recorded using a Skipper-CCD, which enabled the readout noise to be reduced to 0.2 e - . Based on an analytical description of photopeak shapes resulting from the convolution of the PCC effect and Fano noise, we achieved a precise characterization of the energy spectra. This description enabled us to disentangle and quantify the contributions from both Fano noise and the PCC effect. As a result, we determined the Fano factor and the electron-hole pair creation energy. Additionally, we estimated the PCC region of the sensor and, for the first time, experimentally observed the expected skewness of photopeaks at low energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Confirmation of the spectral excess in DAMIC at SNOLAB with skipper CCDs

Here, we present results from a 3.25 kg–day target exposure of two silicon charge-coupled devices (CCDs), each with 24 megapixels and skipper readout, deployed in the DAMIC setup at SNOLAB. With a reduction in pixel readout noise of a factor of 10 relative to the previous detector, we investigate the excess population of low-energy events in the CCD bulk previously observed above expected backgrounds. We address the dominant systematic uncertainty of the previous analysis through a depth fiducialization designed to reject surface backgrounds on the CCDs. The measured bulk ionization spectrum confirms the presence of an excess population of low-energy events in the CCD target with characteristic rate of ~7 events per kg-day and electron-equivalent energies of ~80 eV, whose origin remains unknown.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Smart Readout of Nondestructive Image Sensors with Single Photon-Electron Sensitivity

Image sensors with nondestructive charge readout provide single-photon or single-electron sensitivity, but at the cost of long readout times. We present a smart readout technique to allow the use of these sensors in visible light and other applications that require faster readout times. The method optimizes the readout noise and time by changing the number of times pixels are read out either statically, by defining an arbitrary number of regions of interest in the array, or dynamically, depending on the charge or energy of interest in the pixel. This technique is tested in a Skipper CCD showing that it is possible to obtain deep subelectron noise, and therefore, high resolution of quantized charge, while dynamically changing the readout noise of the sensor. These faster, low noise readout techniques show that the skipper CCD is a competitive technology even where other technologies such as electron multiplier charge coupled devices, silicon photo multipliers, etc. are currently used. This technique could allow skipper CCDs to benefit new astronomical instruments, quantum imaging, exoplanet search and study, and quantum metrology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computational Power of Random Quantum Circuits in Arbitrary Geometries

Empirical evidence for a gap between the computational powers of classical and quantum computers has been provided by experiments that sample the output distributions of two-dimensional quantum circuits. Many attempts to close this gap have utilized classical simulations based on tensor network techniques, and their limitations shed light on the improvements to quantum hardware required to frustrate classical simulability. In particular, quantum computers having in excess of approximately 50 qubits are primarily vulnerable to classical simulation due to restrictions on their gate fidelity and their connectivity, the latter determining how many gates are required (and, therefore, how much infidelity is suffered) in generating highly entangled states. Here, we describe recent hardware upgrades to Quantinuum’s H2 quantum computer, enabling it to operate on up to 56 qubits with arbitrary connectivity and 99.843(5)% two-qubit gate fidelity. We define a class of circuits with random geometries that become hard to classically simulate in very low depth and implement them utilizing the flexible connectivity of H2. A careful analysis demonstrating the fast saturation of classical simulation complexity with depth indicates that H2 can yield data well beyond the reach of state-of-the art classical simulation methods at unprecedented fidelities. We find that the considerable difficulty of classically simulating H2 is likely limited only by qubit number, demonstrating the promise and scalability of the quantum charge-coupled device architecture as continued progress is made toward building larger machines. Published by the American Physical Society 2025

DeCross, M.↗

Electron image contrast analysis of mosaicity in rutile nanocrystals using direct electron detection

Direct electron detection provides high detective quantum efficiency, significantly improved point spread function and fast read-out which have revolutionized the field of cryogenic electron microscopy. However, these benefits for high-resolution electron microscopy (HREM) are much less exploited, especially for in situ study where major impacts on crystallographic structural studies could be made. By using direct detection in electron counting mode, rutile nanocrystals have been imaged at high temperature inside an environmental transmission electron microscope. The improvements in image contrast are quantified by comparison with a charge-coupled device (CCD) camera and by image matching with simulations using an automated approach based on template matching. Together, these approaches enable a direct measurement of 3D shape and mosaicity (~1°) of a vacuum-reduced TiO 2 nanocrystal about 50 nm in size. Thus, this work demonstrates the possibility of quantitative HREM image analysis based on direct electron detection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Multichannel Silicon Package for Large-Scale Skipper-CCD Experiments

The next generation of experiments for light-dark-matter and neutrino searches based on skipper charge-coupled devices (skipper-CCDs) introduces new challenges for the sensor packaging and readout architecture. Scaling the active mass while simultaneously reducing the experimental backgrounds in orders of magnitude requires a novel high-density silicon-based package that must be massively produced and tested. In this work, we present a silicon multichip module design capable of hosting up to 16 skipper-CCDs, along with the fabrication process for the first prototypes. We thoroughly tested and characterized the assembled prototypes to build an empirical model for the video output signal of skipper-CCDs integrated into the silicon package. We then used this model in simulations to optimize the fabrication process and achieve the robust performance required for the full-scale array, which we validated through a new round of prototype fabrication. We outline the specifications selected for the ongoing production of 1500 silicon wafers that will ultimately add up to a 10-kg skipper-CCD array with 24000 readout channels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of Photons Emitted by High-Energy Charged Particles as Background in Single-Photon Resolving Image Sensors

This work introduces an advanced technique optimized for detecting photons generated by charged particles, leveraging Skipper charge coupled device (Skipper-CCD) image sensors. By analyzing background sources and detection efficiencies, the technique achieves strong agreement between experimental results and Cherenkov-based simulations. It also provides a robust framework for investigating secondary photon production in environments with high fluxes of ionizing particles, such as those anticipated in space-based astronomical instruments. These secondary photons present a critical challenge as background noise for next-generation single-photon resolving imagers used to study faint celestial objects. Furthermore, the method exhibits significant potential for broader applications, including exploring photon generation in various substrate materials and examining their transport through multiple interfaces.

Fernandez Moroni, Guillermo [Fermilab; Chicago U.,↗

Effect of Approach Speed and Electrode Geometry on Electrostatic Discharges Off Floating Dielectrics

With the damaging effects of electrostatic discharges (ESDs), it is important to study them within various parameter regimes relevant to real-world scenarios. One such scenario studied here is a floating dielectric with no nearby ground plane with a grounded object approaching at a high rate of speed. One may encounter this scenario when moving objects by hand. Discharge current and radiated fields are captured for discharges drawn from polytetrafluoroethylene (PTFE) and poly methyl methacrylate (PMMA) with approach speeds ranging from 20 to 100 mm/s. Previous studies have shown that at lower speeds in metal-to-metal or metal-to-ground backed dielectric geometries, the peak current and discharge distance decrease with increasing speed. However, in the speed range studied here, an increase in distance and current are observed for increasing speed. Namely, the highest speeds coincide with the highest peak currents and discharge distances of approximately 800 mA and up to 24 mm. Further, with no grounded backing, as opposed to setups in other ESD studies, the electric field between the dielectric and an approaching electrode has a more uniform distribution with highest fields at the electrode, which is elucidated to be the driving factor in the differences revealed in this study. Two spheres of differing diameters and a conical electrode are used to draw discharges off the dielectric surfaces. Captured radiated fields via B-dot sensor, plasma imagery via intesified charge-coupled device (ICCD), and mapping of surface potential reveal that a majority of the energy lost during a discharge goes to gas losses and radiated fields.

36 MATERIALS SCIENCE↗

Advanced Shuttle Strategies for Parallel QCCD Architectures

Trapped ions (TIs) are at the forefront of quantum computing implementation, offering unparalleled coherence, fidelity, and connectivity. However, the scalability of TI systems is hampered by the limited capacity of individual ion traps, necessitating intricate ion shuttling for advanced computational tasks. The quantum charge-coupled device (QCCD) framework has emerged as a promising solution, facilitating ion mobility for universal quantum computation. Current QCCD architectures predominantly feature a linear topology, which is increasingly recognized as inefficient for complex quantum operations. Anticipating the shift toward more efficacious designs, this article introduces an innovative quantum scheduling strategy optimized for parallel QCCD topologies. Our strategy proposes a probabilistic formula for ion movement, alongside ingenious methods for local layer generation and layer compression, yielding a significant reduction in ion shuttle times. Through simulations, we demonstrate that our strategy not only substantially outstrips the linear model but also exhibits better performance over other parallel strategies that employ greedy algorithms. This is achieved through our nuanced resolution of complexities, such as traffic blocks and trap capacity limitations. The consequent reduction in shuttle operations leads to lower energy consumption and an enhancement in the quantum computer's fidelity, ultimately accelerating program execution times.

43 PARTICLE ACCELERATORS↗

Soft X-ray quantum efficiency of a commercial CMOS imaging sensor

The demonstrated performance and cost-effectiveness of complementary metal-oxide-semiconductor (CMOS) sensors make them a potentially attractive option for low-cost space-based X-ray observatories. We have previously reported on the performance of a commercially available backside-illuminated Sony IMX290LLR-C CMOS sensor and found it to offer X-ray spectral resolutions comparable to the charged coupled devices (CCDs) aboard Suzaku and Chandra and to have a sufficient radiation hardness for use in low Earth orbit. Here, in this work, we report on the quantum efficiency (QE) of this sensor, an essential metric for modeling the sensitivity of an instrument as an X-ray detector. Using the Advanced Photon Source at Argonne National Laboratory, we measure the soft X-ray QE of this CMOS sensor to be 0.28 ± 0.02 at a photon energy of 490.5 eV. This energy was chosen for its proximity to the astrophysically important O VII triplet emission lines (~574 eV) studied by the HaloSat mission. Although not surpassing that of the back-illuminated CCDs aboard Suzaku and Chandra, this QE compares favorably to that of the front-illuminated CCDs aboard the same observatories and is competitive with that of the silicon drift detectors used aboard HaloSat, making it a strong candidate for use on future X-ray small satellite (SmallSat) missions.

47 OTHER INSTRUMENTATION↗

In vitro and in vivo NIR fluorescence lifetime imaging with a time-gated SPAD camera

Near-infrared (NIR) fluorescence lifetime imaging (FLI) provides a unique contrast mechanism to monitor biological parameters and molecular events in vivo . Single-photon avalanche diode (SPAD) cameras have been recently demonstrated in FLI microscopy (FLIM) applications, but their suitability for in vivo macroscopic FLI (MFLI) in deep tissues remains to be demonstrated. Herein, we report in vivo NIR MFLI measurement with SwissSPAD2, a large time-gated SPAD camera. We first benchmark its performance in well-controlled in vitro experiments, ranging from monitoring environmental effects on fluorescence lifetime, to quantifying Förster resonant energy transfer (FRET) between dyes. Next, we use it for in vivo studies of target-drug engagement in live and intact tumor xenografts using FRET. Information obtained with SwissSPAD2 was successfully compared to that obtained with a gated intensified charge-coupled device (ICCD) camera, using two different approaches. Our results demonstrate that SPAD cameras offer a powerful technology for in vivo preclinical applications in the NIR window.

47 OTHER INSTRUMENTATION↗

Design and Analysis of a Halo-Measurement Diagnostics

A large dynamical-range diagnostics (LDRD) design at Jefferson Lab will be used at the FAST-IOTA injector to measure the transverse distribution of halo associated with a high-charge electron beam. One important aspect of this work is to explore the halo distribution when the beam has significant angular momentum (i.e. is magnetized). The beam distribution is measured by recording radiation produced as the beam impinges a YAG:Ce screen. The optical radiation is split with a fraction directed to a charged-couple device (CCD) camera. The other part of the radiation is reflected by a digital micromirror device (DMD) that masks the core of the beam distribution. Combining the images recorded by the two cameras provides a measurement of the transverse distribution with over a large dynamical range. The design and analysis of the optical system will be discussed including optical simulation using SRW and the result of a mockup experiment to test the performances of the system will be presented.

43 PARTICLE ACCELERATORS↗

Even lighter particle dark matter

We report on recent progress in the search for dark matter particles with masses from 1 Mev c ^{-2} − 2 to 1 Gev c ^{-2} − 2 . Several dark matter candidates in this mass range are expected to generate measurable electronic-recoil signals in direct-detection experiments. We focus on dark matter particles scattering with electrons in semiconductor detectors since they have fundamentally the highest sensitivity due to their low ionization threshold. Charge-coupled device (CCD) silicon detectors are the leading technology, with significant progress expected in the coming years. We present the status of the CCD program and briefly report on other efforts.

Chavarria, Alvaro E.↗

Li Isotope Signatures using Optical Spectroscopies

The primary goal of this work is to investigate the detection capabilities of laser ablation molecular isotopic spectrometry (LAMIS) and Raman spectroscopy for lithium isotopic determination as related to Li enrichment activities. LAMIS is an emerging spectroscopic technique that takes advantage of the fact that molecules exhibit much larger isotopic wavelength shifts in molecular emission spectra than their atomic counterparts. Raman spectroscopy has been shown to exhibit isotopic shifts if a given molecular vibration involves the isotope of interest. Both techniques are comprised of the same basic hardware: a spectrometer, a laser system (pulsed for LAMIS, pulsed or CW for Raman), and an intensified charge-coupled device (ICCD). Shifts in Raman spectra due to lithium isotopes in Li 2 C0 3 and LiOH*H 2 0 were observed. LAMIS measurements of the same compounds have not been successful yet, as no lithium containing molecular emissions have been identified to this point. However, an isotopic shift of the self-reversal of an atomic lithium emission was observed, which is another optical technique used to measure isotopes.

07 ISOTOPE AND RADIATION SOURCES↗

NIF-TAS Miniature Calibration Station

“On Aug. 8, 2021, an experiment at Lawrence Livermore National Laboratory’s (LLNL’s) National Ignition Facility (NIF) made a significant step toward ignition, achieving a yield of more than 1.3 megajoules (MJ). This advancement puts researchers at the threshold of fusion ignition, an important goal of the NIF, and opens access to a new experimental regime.” NIF experiments are conducted by symmetrically focusing 192 laser beams from NIF (three football fields in length) into the Target Chamber (10-meter diameter sphere) onto a target 2mm in size. The reaction produces a hot spot the diameter of a human hair, generating more than 10 quadrillion watts of fusion power for 100 trillionths of a second. These high pressures and temperatures created by the NIF have only been seen on the surface of the sun. To achieve fusion ignition, the target must be compressed to high pressures and temperatures, which requires symmetric compression. This symmetry requires precise alignment of the laser beams to the target. To achieve this precise symmetry a Target Alignment System (TAS) was developed to aid in aligning the beams to the target. The accomplishment on Aug 8 th could not have been accomplished without the TAS. TAS has proven to be a critical contributor to the success of NIF experiments. Each TAS is composed of several Charge Couple Device (CCD) sensors and various support electronics. Unfortunately, these CCDs are no longer available in industry as they have become outdated and obsolete. There is a limited amount of spare CCDs in the facility. As the NIF continues to increase its energy output of its fusion ignition shot experiments (heigh yield shots), more neutrons are being emitted from the Target Chamber. These neutrons are very damaging to the TAS electronics and its sensors, thus degrading and reducing its life expectancy dramatically. The increase of neutrons exceeds the damage threshold of the CCDs. This would increase the demand for more frequent TAS refurbishments and calibrations. The increase in resources to perform these refurbishments and calibrations would not be sustainable. In efforts to prolong the life of each TAS system it was determined that the TAS should be removed for every High Yield Shot and then reinstalled. The high precision fully calibrated TAS can easily be knocked out of alignment during these installs and reinstall exchanges and being transported in and out of the NIF. The Miniature Calibration Station System was developed to verify that the critical calibration parameters have been preserved during every TAS exchange. The Miniature Calibration Station System (Mini-Cal) would need to be a scaled down (in size and scope), portable version of the offline TAS calibration station to verify the critical TAS parameters are still within tolerances.

42 ENGINEERING↗

DarkNESS Project Testing

This internship involved the design and assembly of a mechanical system for testing skipper-Charge Couple Devices (CCDs) for the DarkNESS project. Skipper-CCDs are highly-sensitive sensors with ultra-low readout noise that are deployed for direct detection of dark matter. DarkNESS is a CubeSat that aims to use skipper CCDs to search for dark matter decaying into X-rays. Currently, in the testing phase, the design process involved creating 3D models of mechanical adapters to operate a prototype space Multi Chip Module (sMCM) package in existing testing chambers in the CCD lab at Fermilab's IERC. The drawings were sent out to be machined, and while waiting to receive the finished adapters, we assembled a vacuum chamber for skipper-CCD testing and performed initial testing of a single CCD controlled by the space Low Threshold Acquisition (sLTA) board that will be employed on the CubeSat. The results showed that the testing conditions are optimal for data to start being taken and analyzed.

Akouedjinoude, Kodjo↗

Computational Tool for Cosmic Ray Flux and Cosmogenic Activation Production Rates

Silicon charge couple devices (CCDs) are used in direct detection dark matter searches. Silicon can be obtained with very high purity and negligible amounts of radioactive contaminants. However, silicon exposed to cosmic rays can be activated, leading to the buildup of radioactive isotopes such as tritium. The decay of tritium can produce signals that cannot be distinguished from the expected signals of dark matter interactions and tritium produced by cosmic rays is expected as one of the leading sources of background for next-generation experiments. The cosmic ray flux depends on variables such as geomagnetic latitude and longitude, atmospheric depth/altitude, solar activity, and surrounding environment for example. The goal of this work is to create a tool that will evaluate the total cosmic ray exposure and related tritium production rate for any given exposure history of a silicon detector. EXcel-based Program for calculation Atmospheric Cosmic-ray Spectrum (EXPACS) was used to obtain the cosmic ray fluxes. We have worked on creating a 3-dimensional gird that spans latitude, longitude, and altitude, and can be used to interpolate the cosmic ray flux at any given location. This computation tool additionally has use for work requiring knowledge of the cosmic ray flux at multiple locations.

79 ASTRONOMY AND ASTROPHYSICS↗

Demonstration of Non-linear Optical Spectroscopy Enhancement utilizing Entangled Photons

Laser-based nonlinear optical spectroscopy approaches have enabled the direct sensing of important chemistry in nearly every fundamental or applied field of science. Yet in many applications, increased detectivity is needed to unravel fundamental mechanisms. One possibility is the use of quantum entanglement to increase detection cross-sections, but it is unproven that enhancement from quantum light extends to practical intensities for chemical sensing. In this report, we investigated the creation and use of entangled photons in nonlinear optical mixing for second harmonic generation and infrared imaging. We observe that the linear scaling of nonlinear mixing from entangled photon sources extends to the mW laser power regime, and enhances direct infrared imaging on Si-based charge coupled device cameras. These results motivate future experimentation on practical uses of entangled photons for nonlinear optical sensing applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗