Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Capillary Pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Sensitivity of injection costs to input petrophysical parameters in numerical geologic carbon sequestration models

Numerical simulations are widely used in feasibility studies for geologic carbon sequestration. Accurate estimates of petrophysical parameters are needed as inputs for these simulations. However, relatively few experimental values are available for CO2-brine systems. Hence, a sensitivity analysis was performed using the STOMP numerical code for supercritical CO2 injected into a model confined deep saline aquifer. The intrinsic permeability, porosity, pore compressibility, and capillary pressure-saturation/relative permeability parameters (residual liquid saturation, residual gas saturation, and van Genuchten alpha and m values) were varied independently. Their influence on CO2 injection rates and costs were determined and the parameters were ranked based on normalized coefficients of variation. The simulations resulted in differences of up to tens of millions of dollars over the life of the project (i.e., the time taken to inject 10.8 million metric tons of CO2). The two most influential parameters were the intrinsic permeability and the van Genuchten m value. Two other parameters, the residual gas saturation and the residual liquid saturation, ranked above the porosity. These results highlight the need for accurate estimates of capillary pressure-saturation/relative permeability parameters for geologic carbon sequestration simulations in addition to measurements of porosity and intrinsic permeability.

Cost estimate↗

Recent bed rest results and countermeasure development at NASA

Bedrest studies of normal subjects provide opportunities to understand physiologic responses to supine posture and inactivity. Furthermore, head-down tilt has been a valuable procedure to investigate adaptation to microgravity and development of countermeasures to maintain the health and well-being of humans during space-flight. Recent bedrest experiments at NASA have ranged in duration from a few hours to 17 weeks. Acute studies of 6 degrees head-down tilt indicate that elevation of capillary blood pressure from 28 to 34 mm Hg and increased capillary perfusion in tissues of the head cause facial and intracranial edema. Intracranial pressure increases from 2 to 17 mm Hg going from upright posture to 6 degrees head-down tilt. Microvessels of the head have a low capacity to constrict and diminish local perfusion. Elevation of blood and tissue fluid pressures/flow in the head may also explain the higher headward bone density associated with long-term head-down tilt. These mechanistic studies of head-down tilt, along with a better understanding of the relative stresses involved with upright posture and lower body negative pressure, have facilitated development of suitable physiologic countermeasures to maintain astronaut health during microgravity. Presently no exercise hardware is available to provide a blood pressure gradient from head to feet in space. However, recent studies in our laboratory suggest that treadmill exercise using a graded lower-body compression suit and 100 mmHg lower body negative pressure provides equivalent or greater physiologic stress than similar upright exercise on Earth. Therefore, exercise within a lower body negative pressure chamber may provide a cost-effective and simple countermeasure to maintain the cardiovascular and neuro-musculoskeletal systems of astronauts during long-duration flight.

manned↗

Microexplosions initiated by a microwave capillary torch on a metal surface at atmospheric pressure

The interaction of the plasma of a microwave capillary argon torch with a metal surface was studied experimentally. It is shown that the interaction of the plasma jet generated by the capillary plasma torch with the metal in atmospheric-pressure air leads to the initiation of microexplosions (sparks) on the metal surface. As a result, the initially smooth surface acquires a relief in the form of microtips and microcraters. The possibility of practical application of the observed phenomenon is discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements of capillary system degradation

The effects of vibration, flow transients, and warm gas pressurization on capillary acquisition system performance were evaluated. The degradation observed under wide band random and high frequency sinusoidal vibration was of a substantially different nature from that obtained under low frequency sinusoidal vibration. With the former, ingestion of small gas bubbles into the liquid region was correlated by a hydrostatic model, while the capillary stability was destroyed and liquid was lost from the liquid region with the latter. No degradation was observed as a result of flow transients in a flight-type multichannel screen device, but it was observed in a transparent laboratory device. Liquid hydrogen outflow tests were conducted with a multilayer dual-screen-liner system with both helium and hydrogen pressurant gases. The tendency towards dryout of the device with hydrogen pressurant was found to increase with increasing pressurant temperature and length of prepressurization period. Dryout did not occur with helium pressurant.

Warren, R. P.↗

Gas Flow in the Capillary of the Atmosphere-to-Vacuum Interface of Mass Spectrometers

Numerical simulations of a gas flow through a capillary being a part of mass spectrometer atmospheric interface were performed using a detailed laminar flow model. The simulated interface consisted of atmospheric and forevacuum volumes connected via a thin capillary. The pressure in the forevacuum volume where the gas was expanding after passing through the capillary was varied in the wide range from 10 to 900 mbar in order to study the volume flow rate as well as the other flow parameters as functions of the pressure drop between the atmospheric and forevacuum volumes. The capillary wall temperature was varied in the range from 24 to 150 °C. Numerical integration of the complete system of Navier-Stokes equations for a viscous compressible gas taking into account the heat transfer was performed using the standard gas dynamic simulation software package ANSYS CFX. The simulation results were compared with experimental measurements of gas flow parameters both performed using our experimental setup and taken from the literature. The simulated volume flow rates through the capillary differed no more than by 10% from the measured ones over the entire pressure and temperatures ranges. A conclusion was drawn that the detailed digital laminar model is able to quantitatively describe the measured gas flow rates through the capillaries under conditions considered. .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Chronic mitral regurgitation and Doppler estimation of left ventricular filling pressures in patients with heart failure

Previous studies relating Doppler parameters and pulmonary capillary wedge pressures (PCWP) typically exclude patients with severe mitral regurgitation (MR). We evaluated the effects of varying degrees of chronic MR on the Doppler estimation of PCWP. PCWP and mitral Doppler profiles were obtained in 88 patients (mean age 55 +/- 8 years) with severe left ventricular (LV) dysfunction (mean ejection fraction 23% +/- 5%). Patients were classified by severity of MR. Patients with severe MR had greater left atrial areas, LV end-diastolic volumes, and mean PCWPs and lower ejection fractions (each P <.01). In patients with mild MR, multiple echocardiographic parameters correlated with PCWP; however, with worsening MR, only deceleration time strongly related to PCWP. From stepwise multivariate analysis, deceleration time was the best independent predictor of PCWP overall, and it was the only predictor in patients with moderate or severe MR. Doppler-derived early mitral deceleration time reliably predicts PCWP in patients with severe LV dysfunction irrespective of degree of MR.

NASA Discipline Cardiopulmonary↗

Measurement of viscosity of gaseous mixtures at atmospheric pressure

Coefficients of viscosity of various types of gas mixtures, including simulated natural-gas samples, have been measured at atmospheric pressure and room temperature using a modified capillary tube method. Pressure drops across the straight capillary tube section of a thermal mass flowmeter were measured for small, well-defined, volume flow rates for the test gases and for standard air. In this configuration, the flowmeter provides the volumetric flow rates as well as a well-characterized capillary section for differential pressure measurements across it. The coefficients of viscosity of the test gases were calculated using the reported value of 185.6 micro P for the viscosity of air. The coefficients of viscosity for the test mixtures were also calculated using Wilke's approximation of the Chapman-Enskog (C-E) theory. The experimental and calculated values for binary mixtures are in agreement within the reported accuracy of Wilke's approximation of the C-E theory. However, the agreement for multicomponent mixtures is less satisfactory, possible because of the limitations of Wilkes's approximation of the classical dilute-gas state model.

Singh, J. J.↗

Passive Water Assurance Delivery System

This report provides an analysis and evaluation of proposed design improvements to the internal water delivery system of NASA’s passive vegetable growing system. The VEGGIE system is designed to provide fresh vegetables and psychological benefits for astronauts aboard the International Space Station. Preliminary testing conducted by NASA for the VEGGIE system revealed flaws in the water delivery system. In these tests, the interface between the plants and the water reservoir failed to provide passive water delivery through the system both in microgravity experiments and experiments conducted on Earth. Our team’s goal was to fix this interface such that water can be passively delivered from the water reservoir to the plant rooting pillows to grow vegetative crops from seed to harvest. The system requirements outlined by NASA include: minimal total mass, on-demand passive water delivery, same dimensions as existing fixtures, minimal pressure on system to prevent leaking, zero mold growth, minimal swelling or clogging for non-flammable capillary materials, pressure stabilization between the water reservoir and plant pillow bags, even dispersal of water during initial priming, minimal bubble obstruction of capillary interface, maximum gas availability to plant roots, growth in a mixed artificial media (50:50 Arcillite:Fafard #2), and to avoid overwatering and drought conditions for plants. The major proposed design improvements are to use a single-interface capillary cord design to directly connect the water reservoir to the plant-rooting pillows, and to alter the water reservoir to model a propellant management device (PMD) in order to ensure consistent and long term watering for the VEGGIE system. The plant rooting pillow required minimal changes outside of replacing the capillary mat on the bottom of the pillow with O-ring insertion points the single-interface capillary system. - Research was conducted to determine which materials are able to uptake water through capillary action to grow Outredgeous Lettuce plants from seed to harvest. The primary requirements to be met by the team's design and evaluation of the capillary interface were: continuous passive watering for 90 days using non-flammable capillary materials and a peak water delivery rate of 30 mL/hr./0.15 m 2 . The results of the team's experimentation showed that the capillary material Nomex displayed the highest capillary water delivery potential with a maximum flow rate of 3.6 mL/hr. The Nomex capillary systems were the only capillary material to consistently grow Outredgeous Lettuce plants from seed to harvest, and displayed the highest average flow rate for multiple experiment sets. The Nomex material was previously incorporated into the VEGGIE system using a matted version of the capillary material, though the team recommends using a cord configuration in the single-interface capillary system for greater system stability. Nomex has proven to be a promising material, as it has passed both health and fire standards for use aboard the International Space Station. PMDs are made of materials that utilize surface tension and adhesive forces to overcome adverse accelerations to improve stability and ensure fluid delivery. PMDs are typically used in fuel tanks to ensure fuel delivery. The team recommends using a sponge PMD in order to mitigate bubble obstruction, decrease system weight, and ensure reliable water delivery to the capillary interface. The PMD water reservoir requires a rigid water reservoir and a vent tube for pressure stabilization. Since PMD’s cannot be tested in 1-G (Earth conditions), further theoretical modeling and testing is required for the proposed water reservoir design. The intent of this proposed system is to passively water plants in microgravity, though the technology is not limited to microgravity applications. The testing at The Ohio State University has proven that the design is highly effective on Earth, demonstrating that it could serve as a simple water delivery system in home and office applications. This would make vegetative crops more accessible in all indoor applications, thereby improving indoor air quality and occupant comfort. Additionally, this technology has great potential to be utilized in greenhouse plant production, cutting back on more sophisticated watering system energy and time requirements.

Alexandria Jensen↗

Three-Dimensional Free Gas Flow Focuses Basin-Wide Microbial Methane to Concentrated Methane Hydrate Reservoirs in Geological System

Here, we present a systematic model that links the generation, migration, phase partitioning, and accumulation of methane into a closed loop as the sediment is deposited from the seafloor and buried through the base of hydrate stability zone (BHSZ). In our model, methane is generated by biodegradation of organic carbon in muds. Hydrate does not form and methane is not trapped until a coarse-grained layer is deposited, because the small pores prevent hydrate formation in muds. Instead, methane diffuses into sands/silts where methane solidifies into hydrate. As hydrate-bearing sands/silts pass through the BHSZ during sediment burial, methane hydrate dissociates, and releases free gas. The released and the newly generated free gas below the BHSZ concentrates into a vertical/dipping zone with low capillary entry pressure and high permeability and flows upward driven its buoyancy. When free gas reaches the hydrate stability zone (HSZ), capillary forces drive free gas to flow laterally, preferentially enter sands/silts, feed hydrate growth, and elevate hydrate saturation. With three-dimensional focused free gas flow, microbial methane that is generated from a much larger fetch area of the entire basin, both above and below the BHSZ, is concentrated into coarse-grained layers at structural closures for hydrate formation. Our model illustrates how geological evolution, microbial methane generation, and gas flow by buoyancy couple to generate concentrated hydrate deposits in geological system. These insights can be used to explore for high-concentration methane hydrate and are important for understanding the methane budget and carbon cycle under the seafloor.

58 GEOSCIENCES↗

Short-term reversibility of ultrastructural changes in pulmonary capillaries caused by stress failure

We previously showed that when the pulmonary capillaries in anesthetized rabbits are exposed to a transmural pressure (Ptm) of approximately 40 mmHg, stress failure of the walls occurs with disruption of the capillary endothelium, alveolar epithelium, or sometimes all layers. The present study was designed to determine whether some of the ultrastructural changes are rapidly reversible when the capillary pressure is reduced. To test this, the Ptm was raised to 52.5 cmH2O for 1 min of blood perfusion and then reduced to 12.5 cmH2O for 3 min of saline-dextran perfusion, followed by intravascular fixation at the same pressure. In another group of animals, the pressure was elevated for 1 min of blood and 3 min of saline-dextran before being reduced. The results were compared with previous studies in which the capillary pressures were maintained elevated at 52.5 cmH2O during the entire procedure. Control studies were also done at sustained low pressures. The results showed that the number of endothelial and epithelial breaks per millimeter and the total fraction area of the breaks were reduced when the pressure was lowered. For example, the number of endothelial breaks per millimeter decreased from 7.1 +/- 2.1 to 2.4 +/- 0.7, and the number of epithelial breaks per millimeter fell from 11.4 +/- 3.7 to 3.4 +/- 0.7. There was evidence that the breaks that closed were those that were initially small and were associated with an intact basement membrane. The results suggest that cells can move along their underlying matrix by rapid disengagement and reattachment of cell adhesion molecules, causing breaks to open or close within minutes.(ABSTRACT TRUNCATED AT 250 WORDS).

Non-NASA Center↗

Development and characterization of the Capillary DirectINJECT System

The DirectINJECT Project was initiated to create a reliable in-line dosing system for delivering a concentrated silver ion biocide solution into spacecraft potable water. Three dosing systems, including a miniature peristaltic pump, a multi-piston pump, and a differential pressure-driven capillary tube, were quickly prototyped and tested. Although the peristaltic and multi-piston pump systems met the desired flow rate range, the capillary system showed the most promise and was chosen for further development. In FY23, the Capillary DirectINJECT dosing system underwent extensive testing with a nominal injection rate of 1.0 μl/min into varying backpressure conditions. A Primary DirectINJECT System with triplicate testbeds was employed for long-term testing, and auxiliary systems like the Secondary DirectINJECT System and Leak Testbed were developed to characterize specific components and investigate various phenomena related to the dosing system. Parameters such as flow rates, reservoir pressures, and temperature were monitored throughout the testing campaigns.

DirectINJECT↗

Two-Phase Flow in Packed Beds, Filters and Orifices: Summary of Findings of the Packed Bed Reactor Experiment Onboard of the International Space Station

Understanding the hydrodynamics of adiabatic two-phase flows in packed bed reactors enables the optimization of chemical reaction rates and products that crucial in pharmaceuticals and energy production industries. Additionally, this understanding aids in designing more efficient and compact reactors and reducing space and resource requirements. Insights gained from studying and understanding such flows in microgravity contribute to advancements of space technologies and the enhancement of our capabilities for undertaking future long duration safe, and sustainable space exploration missions. The objective of the Packed Bed Reactor Experiment series (PBRE and PBRE-2) was to develop a fundamental understanding of the hydrodynamics of adiabatic two-phase flows through porous media in microgravity. This work provides a description of the PBRE fluid system and presents the highlights of the PBRE and PBRE-2 previously flown with different packings and operated onboard of the International Space Station Microgravity Science Glovebox (ISS-MSG). These highlights include flow patterns and two-phase pressure drop, and the impact of capillary effects on pressure drop at various gas and liquid flow rates. This work also presents preliminary results from the Packed Bed Reactor Experiment-Water Recovery Series (PBRE-WRS) recently flown with filters and orifices, which was also operated on the ISS-MSG. The objective of the experiment is to validate hydrodynamic models at a range of gas and liquid flow rates pertinent to the operation of these test articles. The microgravity environment allows for measurement and observation of aspects of fluid dynamics that are unique when compared to observations made in full or partial gravity environments.

ISS↗

Mechanism of Headward Fluid Shift During Exposure To Microgravity

A prominent feature of early cardiovascular adaptation to the microgravity of space flight is a shift of blood and tissue fluid from the lower body to the upper body. Symptoms of this fluid shift include facial edema, nasal congestion, and headache. Normally on Earth, the human body is exposed to hydrostatic (gravitational) blood pressure gradients during upright posture. In this posture, mean arterial pressures at head, heart, and foot levels are approximately 70, 100, and 200 mm Hg, respectively. Theoretically, all hydrostatic pressures within arteries and veins are lost during exposure to microgravity so that mean arterial pressure in all regions of the body is uniform and approximately equal to that at heart level (100 mm Hg). Acute studies of 60 head-down tilt (simulated microgravity on Earth) indicate that facial edema is caused by: 1) elevation of capillary blood pressure from 28 to 34 mm Hg, 2) reduction of blood colloid osmotic pressure 22 to 18 mm Hg, and 3) 50% increase of blood perfusion in tissues of the head. Furthermore, as compared to microvasculature in the feet, microvessels of the head have a low capacity to constrict and diminish local perfusion. Elevation of blood and tissue fluid pressures/flow in the head may also explain the higher headward bone density associated with long-term head-down tilt. These mechanistic studies of head-down tilt, along with a better understanding of the relative stresses involved with upright posture and lower body negative pressure, have facilitated development of physiologic countermeasures to maintain astronaut health during microgravity. Presently no exercise hardware is available to provide a blood pressure gradient from head to feet in space. However, recent studies in our laboratory suggest that treadmill exercise within lower body negative pressure provides equivalent or greater physiologic stress as compared to similar upright exercise on Earth.

Hargens, Alan R.↗

An Earth-Based Model of Microgravity Pulmonary Physiology

There are currently only two practical methods of achieving micro G for experimentation: parabolic flight in an aircraft or space flight, both of which have limitations. As a result, there are many important aspects of pulmonary physiology that have not been investigated in micro G. We propose to develop an earth-based animal model of micro G by using liquid ventilation, which will allow us to fill the lungs with perfluorocarbon, and submersing the animal in water such that the density of the lungs is the same as the surrounding environment. By so doing, we will eliminate the effects of gravity on respiration. We will first validate the model by comparing measures of pulmonary physiology, including cardiac output, central venous pressures, lung volumes, and pulmonary mechanics, to previous space flight and parabolic flight measurements. After validating the model, we will investigate the impact of micro G on aspects of lung physiology that have not been previously measured. These will include pulmonary blood flow distribution, ventilation distribution, pulmonary capillary wedge pressure, ventilation-perfusion matching, and pleural pressures and flows. We expect that this earth-based model of micro G will enhance our knowledge and understanding of lung physiology in space which will increase in importance as space flights increase in time and distance.

Hirschl, Ronald B.↗

Hydrodynamics of Two-Phase Flows through Porous Media in Microgravity: Packed Bed Reactor Experiment onboard of the International Space Station

The objective of the Packed Bed Reactor Experiment was to develop a fundamental understanding of the hydrodynamics of two-phase flow with no phase transition through porous media in microgravity. This work describes two experimental campaigns flown on the International Space Station (ISS) that were designed to achieve the objective. This work presents the results on flow patterns observed, two-phase flow pressure drop in porous media, and the impact of capillary effects on pressure drop at various gas and liquid flow rates. This work is the first to present predictive correlations of the two-phase friction factor for the different regimes identified based on the superficial liquid and gas velocity in microgravity, the first to hypothesize the different regimes based on the change in slope of the pressure gradient versus flow rate plots, the first to address the effects of the capillarity on the pressure gradient and the first to measure column holdup and assess the effective porosity based on the packing and the trapped gas bubbles. Experimental data on pressure drop in gas (N2) – liquid (water) flow show the presence of four different flow regimes in microgravity. Dispersed bubble flow (DB) and pulse (P) flow regimes are detected at high liquid flow rates, whereas at low liquid flow rates “large bubble” or elongated bubble (LB) and “gas channeling” (GC) regimes are observed. For these different flow regimes, different two-phase flow friction factor and pressure gradient correlations are presented for the first time as a function of the gas and liquid modified Reynolds numbers and Suratman number. Within the viscous-capillary (V-C) regime, it is found that the capillary contribution is the dominant force that contributes to the pressure drop for the wetting case (glass). However, for the non-wetting packing (Teflon), the viscous contribution dominates. It was found that the gas hold-up and pressure drop are functions of bed history at low liquid and gas flow rates with the magnitude of the hysteresis decreasing with increasing flow rates. PBRE-2 results show that the capillary force is a strong function of the superficial liquid velocity but is a much weaker function of the superficial gas velocity and varies inversely with the particle diameter. Within the Viscous-Capillary (V-C) regime, over 90% of the pressure gradient is attributed to the capillary contribution in the gas continuous regime. However, in the large bubble regime, the viscous and capillary contributions were comparable. After the completion of PBRE-2 with glass spherical beads, another bed packed with alumina was installed. Pressure gradient data for the alumina packed bed (PBRE-Water Recovery) were transferred to the PI and were not analyzed by the authors of this work. The Packed Bed Reactor Experiment concluded its on-orbit operation after two successful campaigns of testing in 2017 and in 2021. The flight hardware was brought back from orbit and is being reconditioned for a series of future experiments referred to as PBRE-WRS in support of water recovery (WRS). The WRS series consists of testing different two-phase fluid system components and packed beds to assess their pressure gradient characteristics, which will be used for designing packed bed reactors for various applications relevant to life support. Although there is so much relevance of the experimental results obtained from the two PBRE campaign in microgravity to life support, these findings also apply to other applications that involve two phase flow in porous medium such as fuel cells, transport of nutrient to plants in space and other chemical and materials processing that involve two phase flows. These systems operate differently in microgravity because, due to the lack of buoyancy, the density difference between the phases becomes irrelevant and no longer leads to phase separation.

Packed Bed↗

Experimental analysis of spatial correlation effects on capillary trapping of supercritical CO 2 at the intermediate laboratory scale in heterogeneous porous media

Several numerical studies have demonstrated that the heterogeneous nature of typical sedimentary formations can favorably dampen the accumulation of mobile CO 2 phase underneath the caprock. Core flooding experiments have also shown that contrasts in capillary entry pressure can lead to buildup of nonwetting fluid phase (NWP) at interfaces between facies. Explicit representation of geological heterogeneity at the intermediate (cm-to-m) scale is a powerful approach to identify the key mechanisms that control multiphase flow dynamics in porous media. The ability to carefully control flow regime and permeability contrast at a scale that is relevant to CO 2 plume dynamics in saline formations offers valuable information to understand immiscible displacement processes and provides a benchmark for mathematical models. To provide insight into the impact of capillary heterogeneity on flow dynamics and trapping efficiency of supercritical CO 2 under successive drainage and imbibition conditions, we present an experimental investigation conducted in a synthetic sand reservoir. By mimicking the interplay of governing forces at reservoir conditions via application of surrogate fluids, we performed three immiscible displacement experiments to observe the entrapment of NWP in heterogeneous porous media. Capillary trapping performance is evaluated for each scenario through spatial and temporal variations of NWP saturation; for this reason we adopted X-ray attenuation to precisely measure phase saturation throughout the flow domain and apply spatial moment analysis. Furthermore, the sweeping performance of two different permeability fields with comparable variance but distinct spatial correlation was compared against a homogeneous base case with equivalent mean permeability by means of spatial moment analysis.

58 GEOSCIENCES↗