At least 325 records · Page 18

Thermal conductivity of gaseous and liquid hydrogen

Normal and para-hydrogen conductivity measurements at temperatures from 200 to 17 deg K, at densities up to 2.6 times critical density, and at pressures to 15 MN/sq m are made. Using new calorimeter, data are analyzed as functions of density at fixed temperatures and of temperature at fixed densities

Diller, D. E.↗

Evaluation of a self-aspirating local total enthalpy probe in a low-density arc-heated hypersonic wind tunnel

A shock-swallowing, self-aspirating, local total enthalpy probe has been evaluated in a low density nonequilibrium, hypervelocity airstream. The probe, which incorporated an air gap to separate the internal and external cooling passages, was tested in an electric archeated wind tunnel at an average Mach number of 11.7 and an average Reynolds number per meter of 57,000. The free stream enthalpy probe data are compared with bulk calorimeter measurements of total enthalpy at the beginning of the gas expansion and with local total enthalpy inferred from a theoretical nonequilibrium gas expansion model by using free stream velocity measurements obtained from a mass flow probe. The three techniques are in relative agreement at the lower enthalpies. However, at the higher enthalpies, the enthalpy probe data lie considerably below the other data. This low data may be caused by the chemical and vibrational energy frozen in the flow not being sensed by the probe. Other problems associated with the shock-swallowing total enthalpy probe are discussed, and recommendations for improving the probe performance are presented.

Guy, R. W.↗

Measurement of apparent thermal conductivity of multilayer insulations at low compressive loads.

A description is presented of the test calorimeter, the experimental technique, and the results obtained in an evaluation of four multilayer insulations selected for application on future multilaunch space vehicles utilizing liquid hydrogen and oxygen for orbital operations. Particular attention is paid to techniques for minimizing error in obtaining thermal conductivity data. The effective conductivity for four high-performance insulations was determined at a minimum of four compressive loads in the range from 0.0001 to 0.1 psi. Results show that the thermal conductivity of multilayer insulations is insensitive to small changes in mechanical loading at 1 torr interstitial gas pressure, but becomes increasingly more sensitive to mechanical loading as the interstitial gas pressure is reduced.

Holmes, V. L.↗

Effects of overlaps, stitches, and patches on multilayer insulation.

The effects of spacecraft installation-type discontinuities on aluminized Mylar multilayer insulation have been measured using an electrically heated cylindrical calorimeter. The experimental results have been reproducible within plus or minus 10% or better for identical blankets and less than plus or minus 5% for the same blanket. Good blanket performance can be obtained using short interleaving for joints, eliminating stitched seams, and using small patches, particularly over the hot side of stitches. The heat loss through stitching is excessive but highly localized. Analytical models matched to thermocouple test results are presented. The manner in which radiation and conduction participate in heat transfer adjacent to discontinuities is indicated. High lateral heat transfer is also established as an important phenomenon in the vicinity of a discontinuity.

Stimpson, L. D.↗

Nuclear light bulb propellant heating simulation using a tungsten/argon aerosol and radiation from a dc arc surrounded by a segmented mirror cavity

Experiments were conducted to simulate radiant heating of the propellant stream of a nuclear light bulb engine to obtain high bulk exit temperatures in the flowing simulated propellant stream by absorption of large fractions of the incident thermal radiation. A high-power, vortex-stabilized dc arc within an uncooled fused silica tube was used as the radiant energy source. It was surrounded by a mirror system to increase the radiation incident on the simulated propellant. The 12.7-cm-long by 2.3-cm-wide, diverging-duct test section had a transparent front wall and a reflecting rear wall. The central stream of seeded gas, a tungsten-particle/argon aerosol, had unseeded argon buffer layers on both sides to prevent coating of the duct walls. Arc operating times were approximately 0.5 sec with power levels up to 780 kW. Bulk exit temperatures were measured using a calorimeter downstream of the duct. The maximum simulated propellant bulk exit temperature obtained was 4515 K, compared with 3860 K in previous tests, 3300 to 3700 K expected in in-reactor tests in the Nuclear Furnace, and 6660 K in the reference nuclear light bulb engine. The maximum temperature in these tests was limited primarily by the amount of radiation incident on the test section (determined by the arc operating characteristics and the effectiveness of the mirror cavity).

Klein, J. F.↗

FLOX/MMH rocket engine assemblies

A 6-month program was conducted to fabricate, acceptance test, and deliver to JPL two FLOX/MMH rocket engine assemblies. Acceptance testing consisted of injector cold flows and 15-second-duration hot firings with the engine assemblies. An additional objective of the program was to determine the feasibility of utilizing FLOX/MMH thrust chamber components with the F2/N2H4 propellant combination. Feasibility studies consisted of analysis, cold flow, and comparative F2/N2H4-FLOX/MMH calorimeter hot fire testing, followed by a 500-second duration F2/N2H4 demonstration test.

Source record↗

Design improvement, qualification testing, purge and vent investigation, fabrication, and documentation of a GAC-9 insulation system

Results of the research and development program to determine the purge and vent characteristics of the GAC-9 insulation system are summarized. The work scope comprised: (1) literature survey; (2) design improvement and insulation effort; (3) testing; and (4) evaluation of test results. Program objectives to be realized are: (1) definition of purge gas flow characteristics of the GAC-9 insulation system through laboratory measurements; and (2) demonstration of insulation effectiveness as a system for prelaunch purging and launch venting of the 76-cm diameter calorimeter, which is a subscale model simulating a realistic type of GAC-9 insulation application.

Shriver, C. B.↗

Afterburner Performance of Circular V-Gutters and a Sector of Parallel V-Gutters for a Range of Inlet Temperatures to 1255 K (1800 F)

Combustion tests of two V-gutter types were conducted in a 19.25-in. diameter duct using vitiated air. Fuel spraybars were mounted in line with the V-gutters. Combustor length was set by flame-quench water sprays which were part of a calorimeter for measuring combustion efficiency. Although the levels of performance of the parallel and circular array afterburners were different, the trends with geometry variations were consistent. Therefore, parallel arrays can be used for evaluating V-gutter geometry effects on combustion performance. For both arrays, the highest inlet temperature produced combustion efficiencies near 100 percent. A 5-in. spraybar - to - V-gutter spacing gave higher efficiency and better lean blowout performance than a spacing twice as large. Gutter durability was good.

Brandstetter, J. Robert↗

RF-source resistance meters

Several embodiments of RF source resistance measuring devices are disclosed. Common to all embodiments in the feature of the inclusion of at least one variable resistor, and a peak readout meter. In one embodiment, two ganged unloaded potentiometers are employed while another embodiment comprises an automaticnulling RF power bridge circuit with a variable rather than a fixed bridge reference resistance. A third embodiment comprises a calorimeter with a varible rather than a fixed resistor, while in another embodiment attenuator pads with variable resistors are employed.

Oakley, E. C.↗

Regeneratively cooled rocket engine for space storable propellants

Analyses and experimental studies were performed with the OF2 (F2/O2)/B2H6 propellant combination over a range in operating conditions to determine suitability for a space storable pressure fed engine configuration for an extended flight space vehicle configuration. The regenerative cooling mode selected for the thrust chamber was explored in detail with the use of both the fuel and oxidizer as coolants in an advanced milled channel construction thrust chamber design operating at 100 psia chamber pressure and a nominal mixture ratio of 3.0 with a 60:1 area ratio nozzle. Benefits of the simultaneous cooling as related to gaseous injection of both fuel and oxidizer propellants were defined. Heat transfer rates, performance and combustor stability were developed for impinging element triplet injectors in uncooled copper calorimeter hardware with flow, pressure and temperature instrumentation. Evaluation of the capabilities of the B2H6 and OF2 during analytical studies and numerous tests with flow through electrically heated blocks provided design criteria for subsequent regenerative chamber design and fabrication.

Wagner, W. R.↗

Method for determining thermo-physical properties of specimens

The square root of the product of thermophysical properties q, c and k, where p is density, c is specific heat and k is thermal conductivity, is determined directly on a test specimen such as a wind tunnel model. The test specimen and a reference specimen of known specific heat are positioned at a given distance from a heat source. The specimens are provided with a coating, such as a phase change coating, to visually indicate that a given temperature was reached. A shutter interposed between the heat source and the specimens is opened and a motion picture camera is actuated to provide a time record of the heating step. The temperature of the reference specimen is recorded as a function of time. The heat rate to which both the test and reference specimens were subjected is determined from the temperature time response of the reference specimen by the conventional thin-skin calorimeter equation.

Jones, R. A.↗

Boiling heat transfer to LN2 and LH2 - Influence of surface orientation and reduced body forces

The quantitative determination of the influence of heater surface orientation and gravity on nucleate pool boiling of liquid nitrogen and liquid hydrogen is described. A transient calorimeter technique, well suited for obtaining pool boiling data under reduced gravity and used earlier by Clark and Merte (1963), was employed after being adapted to flat a surface whose orientation could be varied. The obtained determination results are reviewed.

Merte, H., Jr.↗

Predicting spacecraft multilayer insulation performance from heat transfer measurements

Multilayer insulation (MLI) ideally consists of a series of radiation shields with low-conductivity spacers. When MLI blankets were installed on cryogenic tanks or spacecraft, a large discrepancy between the calorimeter measurements and the performance of the installed blankets was discovered. It was found that discontinuities such as exposed edges coupled with high lateral heat transfer created 'heat leaks' which overshadowed the basic heat transfer of the insulation. Approaches leading to improved performance predictions of MLI units are discussed.

Stimpson, L. D.↗

Measurement of the primary cosmic electron spectrum from 10 to about 250-GeV

The intensity and energy spectrum of primary cosmic electrons from 10 to approximately 250 GeV was studied using balloon-borne detectors. Both of the detectors were large area ionization calorimeters with frequent sampling of showering particles and were capable of energy resolution of approximately 7%. A time-of-flight system and detectors to sample the lateral properties of showers were used to examine and improve background rejection. The results of the balloon flights from Alamogordo, N.M. in 1970 and Cape Girardeau, Missouri in 1972 indicated that the primary cosmic ray electron differential energy spectrum exhibits no change of slope in the energy range measured and is well represented by a power law. These results indicate that the cosmic electron spectrum is steeper than the cosmic ray proton spectrum. It is shown that these data are consistent with the leakage lifetime model for the propagation of cosmic electrons in the Galaxy, although other more complex models cannot be excluded on the basis of these data.

Silverberg, R. F.↗

Absolute radiometry and the solar constant

A series of active cavity radiometers (ACRs) are described which have been developed as standard detectors for the accurate measurement of irradiance in absolute units. It is noted that the ACR is an electrical substitution calorimeter, is designed for automatic remote operation in any environment, and can make irradiance measurements in the range from low-level IR fluxes up to 30 solar constants with small absolute uncertainty. The instrument operates in a differential mode by chopping the radiant flux to be measured at a slow rate, and irradiance is determined from two electrical power measurements together with the instrumental constant. Results are reported for measurements of the solar constant with two types of ACRs. The more accurate measurement yielded a value of 136.6 plus or minus 0.7 mW/sq cm (1.958 plus or minus 0.010 cal/sq cm per min).

Willson, R. C.↗

Thermostructural testing of instrumented ATJ-S graphite nosetip models in the AFFDL 50 MW rent facility

Instrumented ATJ-S graphite shell nosetip models were tested in the AFFDL 50 MW RENT Facility. The inside surface of the models were instrumented with seven thermocouples and three clip-on extensometers. One thermocouple was located at the inside stagnation point and three thermocouples were located at 120 degree intervals on the aft portion of the skirt of the model. In addition, three thermocouples at 120 degree intervals plus three clip-on extensometers at 120 degree intervals offset 60 degrees from the thermocouples were located in the critical region. The outside surface temperature of the models was monitored in two locations by optical pyrometers. Finally, the tests were recorded by three high speed motion picture cameras. Pressure models and calorimeters were also tested in order to help define the flow field condition and heating distribution around the models.

Budde, C. L.↗