Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CT SCANNER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Spectral optimization for micro-CT

Purpose: To optimize micro-CT protocols with respect to x-ray spectra and thereby reduce radiation dose at unimpaired image quality. Methods: Simulations were performed to assess image contrast, noise, and radiation dose for different imaging tasks. The figure of merit used to determine the optimal spectrum was the dose-weighted contrast-to-noise ratio (CNRD). Both optimal photon energy and tube voltage were considered. Three different types of filtration were investigated for polychromatic x-ray spectra: 0.5 mm Al, 3.0 mm Al, and 0.2 mm Cu. Phantoms consisted of water cylinders of 20, 32, and 50 mm in diameter with a central insert of 9 mm which was filled with different contrast materials: an iodine-based contrast medium (CM) to mimic contrast-enhanced (CE) imaging, hydroxyapatite to mimic bone structures, and water with reduced density to mimic soft tissue contrast. Validation measurements were conducted on a commercially available micro-CT scanner using phantoms consisting of water-equivalent plastics. Measurements on a mouse cadaver were performed to assess potential artifacts like beam hardening and to further validate simulation results. Results: The optimal photon energy for CE imaging was found at 34 keV. For bone imaging, optimal energies were 17, 20, and 23 keV for the 20, 32, and 50 mm phantom, respectively. For density differences, optimal energies varied between 18 and 50 keV for the 20 and 50 mm phantom, respectively. For the 32 mm phantom and density differences, CNRD was found to be constant within 2.5% for the energy range of 21-60 keV. For polychromatic spectra and CMs, optimal settings were 50 kV with 0.2 mm Cu filtration, allowing for a dose reduction of 58% compared to the optimal setting for 0.5 mm Al filtration. For bone imaging, optimal tube voltages were below 35 kV. For soft tissue imaging, optimal tube settings strongly depended on phantom size. For 20 mm, low voltages were preferred. For 32 mm, CNRD was found to be almost independent of tube voltage. For 50 mm, voltages larger than 50 kV were preferred. For all three phantom sizes stronger filtration led to notable dose reduction for soft tissue imaging. Validation measurements were found to match simulations well, with deviations being less than 10%. Mouse measurements confirmed simulation results. Conclusions: Optimal photon energies and tube settings strongly depend on both phantom size and imaging task at hand. For in vivo CE imaging and density differences, strong filtration and voltages of 50-65 kV showed good overall results. For soft tissue imaging of animals the size of a rat or larger, voltages higher than 65 kV allow to greatly reduce scan times while maintaining dose efficiency. For imaging of bone structures, usage of only minimum filtration and low tube voltages of 40 kV and below allow exploiting the high contrast of bone at very low energies. Therefore, a combination of two filtrations could prove beneficial for micro-CT: a soft filtration allowing for bone imaging at low voltages, and a variable stronger filtration (e.g., 0.2 mm Cu) for soft tissue and contrast-enhanced imaging.

60 APPLIED LIFE SCIENCES↗

SU-E-T-391: Evaluation of Image Parameters Impact On the CT Calibration Curve for Proton Therapy

Purpose: The calibration of the Hounsfield units (HU) to relative proton stopping powers (RSP) is a crucial component in assuring the accurate delivery of proton therapy dose distributions to patients. The purpose of this work is to assess the uncertainty of CT calibration considering the impact of CT slice thickness, position of the plug within the phantom and phantom sizes. Methods: Stoichiometric calibration method was employed to develop the CT calibration curve. Gammex 467 tissue characterization phantom was scanned in Tomotherapy Cheese phantom and Gammex 451 phantom by using a GE CT scanner. Each plug was individually inserted into the same position of inner and outer ring of phantoms at each time, respectively. 1.25 mm and 2.5 mm slice thickness were used. Other parameters were same. Results: HU of selected human tissues were calculated based on fitted coefficient (Kph, Kcoh and KKN), and RSP were calculated according to the Bethe-Bloch equation. The calibration curve was obtained by fitting cheese phantom data with 1.25 mm thickness. There is no significant difference if the slice thickness, phantom size, position of plug changed in soft tissue. For boney structure, RSP increases up to 1% if the phantom size and the position of plug changed but keep the slice thickness the same. However, if the slice thickness varied from the one in the calibration curve, 0.5%–3% deviation would be expected depending on the plug position. The Inner position shows the obvious deviation (averagely about 2.5%). Conclusion: RSP shows a clinical insignificant deviation in soft tissue region. Special attention may be required when using a different slice thickness from the calibration curve for boney structure. It is clinically practical to address 3% deviation due to different thickness in the definition of clinical margins.

60 APPLIED LIFE SCIENCES↗

Measurements of CO 2 ‐brine relative permeability in Berea sandstone using pressure taps and a long core

Abstract We measured CO 2 ‐brine relative permeability by performing five steady‐state primary drainage experiments in a 116 mD Berea sandstone core at 20°C and 10.34 MPa. We used a long (60.8 cm) core and four pressure taps to study and minimize end effects that can plague CO 2 ‐brine relative permeability measurements, and we obtained in situ saturation profiles using a medical X‐ray Computed Tomography (CT) scanner. We found that entrance and exit effects propagated ∼5 cm into the core, but the center sections of the core had uniform saturation. From the saturations and pressure drops, we obtained both CO 2 and brine relative permeability in the center sections. We also obtained CO 2 relative permeability at the entrance section where the brine saturation was lower and not uniform. The 15‐cm long exit section of the core had non‐uniform saturation and a measured pressure drop that was on the order of the capillary pressure and hence was unreliable for calculating relative permeability. We found that the CO 2 and brine relative permeabilities determined in five experiments were consistent with each other and followed two simple Corey‐type models that are similar to those seen in oil‐brine relative permeability measurements. We discuss why end effects are much greater in the CO 2 ‐brine system than in oil‐brine systems, and how this is a possible explanation of the low CO 2 relative permeabilities recently reported for the CO 2 ‐brine systems. © 2016 Society of Chemical Industry and John Wiley & Sons, Ltd.

Chen, Xiongyu↗

Cone-beam Computed Tomography-guided Stereotactic Liver Punctures: A Phantom Study

Purpose: Images from computed tomography (CT), combined with navigation systems, improve the outcomes of local thermal therapies that are dependent on accurate probe placement. Although the usage of CT is desired, its availability for time-consuming radiological interventions is limited. Alternatively, three-dimensional images from C-arm cone-beam CT (CBCT) can be used. The goal of this study was to evaluate the accuracy of navigated CBCT-guided needle punctures, controlled with CT scans. Methods: Five series of five navigated punctures were performed on a nonrigid phantom using a liver specific navigation system and CBCT volumetric dataset for planning and navigation. To mimic targets, five titanium screws were fixed to the phantom. Target positioning accuracy (TPE{sub CBCT}) was computed from control CT scans and divided into lateral and longitudinal components. Additionally, CBCT-CT guidance accuracy was deducted by performing CBCT-to-CT image coregistration and measuring TPE{sub CBCT-CT} from fused datasets. Image coregistration was evaluated using fiducial registration error (FRE{sub CBCT-CT}) and target registration error (TRE{sub CBCT-CT}). Results: Positioning accuracies in lateral directions pertaining to CBCT (TPE{sub CBCT} = 2.1 {+-} 1.0 mm) were found to be better to those achieved from previous study using CT (TPE{sub CT} = 2.3 {+-} 1.3 mm). Image coregistration error was 0.3 {+-} 0.1 mm, resulting in an average TRE of 2.1 {+-} 0.7 mm (N = 5 targets) and average Euclidean TPE{sub CBCT-CT} of 3.1 {+-} 1.3 mm. Conclusions: Stereotactic needle punctures might be planned and performed on volumetric CBCT images and controlled with multidetector CT with positioning accuracy higher or similar to those performed using CT scanners.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rapid determination of supercritical CO 2 and brine relative permeability using an unsteady-state flow method

In this study, relative permeability of supercritical CO 2 (scCO 2 ) and brine was determined in reactive and non-reactive rock cores using a combination of unsteady-state methodology and computed tomography. Experiments were conducted using a medical grade CT scanner to determine saturation using a custom Python script. The saturation and differential pressure across the core were then used to derive four empirical constants to calculate relative permeability. This methodology increases temporal efficiency while reducing experimental complexity. Additionally, we show that the method can be used to determine scCO 2 relative permeability in a wide range of lithologies and flow rates, and with the ability to account for matrix dissolution during scCO 2 flooding.

54 ENVIRONMENTAL SCIENCES↗

Impacts of irregularly-distributed acidified brine flow on geo-chemo-mechanical alteration in an artificial shale fracture under differential stress

The efficacy of geological carbon sequestration is reliant on the integrity of the caprock and its resistance to physical and chemical alteration. Caprocks with high abundance of reactive carbonates like calcite are susceptible to acid-promoted dissolution and can result in structural weakening. This work investigates the effect of acidified brine flow through an artificially fractured, high-carbonate (30 % by XRD) shale under differential compressive stress. Cylindrical samples were cut in half vertically and milled to create an artificial fracture with interlocking asperities and open channels. Samples were sheared with a single applied stress in a custom flow cell housed within an industrial CT scanner. Further, either acidic (pH 4) or reservoir-simulated (pH 9.5) brine was flowed through the artificial fracture for 7–8 days under reservoir pressure and room temperature. Model simulations indicate flow mainly occurred in open channels, with limited flow between overlapping asperities. Analysis of fracture surfaces by optical and scanning electron microscopy show increased surface alteration and roughness after exposure to pH 4 versus pH 9.5 brine indicating mineral dissolution/loss, and this effect is greater in areas that receive the highest brine flows. Similarly, surface analysis by scratch testing shows fracture toughness decreases more after exposure to acidic versus reservoir-simulated brine, with the greatest alteration in areas of highest acidic brine flows. Despite weakening, no shear slip occurred. Overall, the results indicate that acidified brine can result in significant physical and geomechanical alteration of irregular fracture surfaces in shale caprock, with greatest effects in preferential flow regions.

58 GEOSCIENCES↗

Livermore tomography tools: Accurate, fast, and flexible software for tomographic science

Livermore Tomography Tools (LTT) is a customizable scientific software package that enables a broad range of research and development efforts into computed tomography (CT). Here, it was developed to process x-ray and neutron CT data accurately and rapidly from raw detector counts to reconstructed volumes with the flexibility to handle many special cases. LTT fulfills long-term CT software goals to provide quantitatively accurate results reported in physical units (e.g., mm -1 or cm -1 ) while exploiting all available computational advantages to maximize speed. Written in C/C++ with support for multiple CPUs and GPUs, LTT runs on many computing platforms (Linux/Unix, Windows, and Mac; laptops to supercomputers). As a result, LTT can:process data acquired from various custom-built and commercially available CT scanners, model and simulate x-ray and neutron interactions to encourage algorithm prototyping, and allow for rapid insertion of the latest algorithms.We describe LTT’s software architecture, user interfaces, and its 88 algorithms (as of this writing) for pre-processing, reconstruction, post-processing, and simulation that support many scanner geometries (parallel-, fan-, cone-beam, and custom). Several applications are presented that illustrate LTT’s accuracy, speed, and flexibility relative to other solutions.

36 MATERIALS SCIENCE↗

Development of an X-ray Computed Tomography System for Non-Invasive Imaging of Industrial Materials

X-ray computed tomography is a powerful non-invasive imaging technique for viewing an object's inner structures in two-dimensional cross-section images without the need to physically section it. The invention of CT techniques revolutionised the field of medical diagnostic imaging because it provided more detailed and useful information than any previous non-invasive imaging techniques. The method is increasingly being used in industry, aerospace, geosciences and archaeology. This paper describes the development of an X-ray computed tomography system for imaging of industrial materials. The theoretical aspects of CT scanner, the system configurations and the adopted algorithm for image reconstruction are discussed. The penetrating rays from a 160 kV industrial X-ray machine were used to investigate structures that manifest in a manufactured component or product. Some results were presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pilot Study to Confirm that Fat and Liver can be Distinguished by Spectroscopic Tissue Response on a Medipix-All-Resolution System-CT (MARS-CT)

NAFLD, liver component of the 'metabolic' syndrome, has become the most common liver disease in western nations. Non-invasive imaging techniques exist, but have limitations, especially in detection and quantification of mild to moderate fatty liver. In this pilot study, we produced attenuation curves from biomedical-quality projection images of liver and fat using the MARS spectroscopic-CT scanner. Difficulties obtaining attenuation spectra after reconstruction demonstrated that standard reconstruction programs do not preserve spectral information.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Attenuation properties and percentage depth dose of tannin-based Rhizophora spp. particleboard phantoms using computed tomography (CT) and treatment planning system (TPS) at high energy x-ray beams

A set of tannin-based Rhizophora spp. particleboard phantoms with dimension of 30 cm x 30 cm was fabricated at target density of 1.0 g/cm{sup 3}. The mass attenuation coefficient of the phantom was measured using {sup 60}Co gamma source. The phantoms were scanned using Computed Tomography (CT) scanner and the percentage depth dose (PDD) of the phantom was calculated using treatment planning system (TPS) at 6 MV and 10 MV x-ray and compared to that in solid water phantoms. The result showed that the mass attenuation coefficient of tannin-based Rhizohora spp. phantoms was near to the value of water with χ{sup 2} value of 1.2. The measured PDD also showed good agreement with solid water phantom at both 6 MV and 10 MV x-ray with percentage deviation below 8% at depth beyond the maximum dose, Z{sub max}.

07 ISOTOPE AND RADIATION SOURCES↗

In vivo dosimetry for estimation of effective doses in multislice CT coronary angiography

In vivo dosimetry represents a technique that has been widely employed to evaluate the dose to the patient mainly in radiotherapy. Considering the increment in dose to the population due to new high-dose multislice CT examinations, such as coronary angiography, it is becoming important to more accurately know the dose to the patient. The desire to know patient dose extends even to radiological examinations. Thermoluminescent dosimeters are considered the gold standard for in vivo dosimetry, but their use is time consuming. A rapid, less labor-intensive method has been developed to perform in vivo dosimetry using radiochromic film positioned next to the patient's skin. Multislice CT scanners allow the estimation of the effective dose to the patient from the dose length product (DLP) parameter, the value of which is displayed on the acquisition console, simply multiplying the DLP by published conversion factors. The method represents only an approximation based on standard size circular phantoms and neglects the actual size of the patient. More accurate evaluations can be carried out using software-based Monte Carlo simulations. However, these methods do not consider possible dose reduction techniques, such as automatic tube-current modulation. For 22 patients effective doses measured by in vivo dosimetry and calculated by software were compared. The technique of using in vivo dosimetry measured with radiochromic film appears a promising procedure for improving the assessment of the effective dose to the patient.

61 RADIATION PROTECTION AND DOSIMETRY↗

Empirical dual energy calibration (EDEC) for cone-beam computed tomography

Material-selective imaging using dual energy CT (DECT) relies heavily on well-calibrated material decomposition functions. These require the precise knowledge of the detected x-ray spectra, and even if they are exactly known the reliability of DECT will suffer from scattered radiation. We propose an empirical method to determine the proper decomposition function. In contrast to other decomposition algorithms our empirical dual energy calibration (EDEC) technique requires neither knowledge of the spectra nor of the attenuation coefficients. The desired material-selective raw data p{sub 1} and p{sub 2} are obtained as functions of the measured attenuation data q{sub 1} and q{sub 2} (one DECT scan=two raw data sets) by passing them through a polynomial function. The polynomial's coefficients are determined using a general least squares fit based on thresholded images of a calibration phantom. The calibration phantom's dimension should be of the same order of magnitude as the test object, but other than that no assumptions on its exact size or positioning are made. Once the decomposition coefficients are determined DECT raw data can be decomposed by simply passing them through the polynomial. To demonstrate EDEC simulations of an oval CTDI phantom, a lung phantom, a thorax phantom and a mouse phantom were carried out. The method was further verified by measuring a physical mouse phantom, a half-and-half-cylinder phantom and a Yin-Yang phantom with a dedicated in vivo dual source micro-CT scanner. The raw data were decomposed into their components, reconstructed, and the pixel values obtained were compared to the theoretical values. The determination of the calibration coefficients with EDEC is very robust and depends only slightly on the type of calibration phantom used. The images of the test phantoms (simulations and measurements) show a nearly perfect agreement with the theoretical {mu} values and density values. Since EDEC is an empirical technique it inherently compensates for scatter components. The empirical dual energy calibration technique is a pragmatic, simple, and reliable calibration approach that produces highly quantitative DECT images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A comprehensive evaluation of the PRESAGE/optical-CT 3D dosimetry system

This work presents extensive investigations to evaluate the robustness (intradosimeter consistency and temporal stability of response), reproducibility, precision, and accuracy of a relatively new 3D dosimetry system comprising a leuco-dye doped plastic 3D dosimeter (PRESAGE) and a commercial optical-CT scanner (OCTOPUS 5x scanner from MGS Research, Inc). Four identical PRESAGE 3D dosimeters were created such that they were compatible with the Radiologic Physics Center (RPC) head-and-neck (H and N) IMRT credentialing phantom. Each dosimeter was irradiated with a rotationally symmetric arrangement of nine identical small fields (1x3 cm{sup 2}) impinging on the flat circular face of the dosimeter. A repetitious sequence of three dose levels (4, 2.88, and 1.28 Gy) was delivered. The rotationally symmetric treatment resulted in a dose distribution with high spatial variation in axial planes but only gradual variation with depth along the long axis of the dosimeter. The significance of this treatment was that it facilitated accurate film dosimetry in the axial plane, for independent verification. Also, it enabled rigorous evaluation of robustness, reproducibility and accuracy of response, at the three dose levels. The OCTOPUS 5x commercial scanner was used for dose readout from the dosimeters at daily time intervals. The use of improved optics and acquisition technique yielded substantially improved noise characteristics (reduced to {approx}2%) than has been achieved previously. Intradosimeter uniformity of radiochromic response was evaluated by calculating a 3D gamma comparison between each dosimeter and axially rotated copies of the same dosimeter. This convenient technique exploits the rotational symmetry of the distribution. All points in the gamma comparison passed a 2% difference, 1 mm distance-to-agreement criteria indicating excellent intradosimeter uniformity even at low dose levels. Postirradiation, the dosimeters were all found to exhibit a slight increase in opaqueness with time. However, the relative dose distribution was found to be extremely stable up to 90 h postirradiation indicating excellent temporal stability. Excellent interdosimeter reproducibility was also observed between the four dosimeters. Gamma comparison maps between each dosimeter and the average distribution of all four dosimeters showed full agreement at the 2% difference, 2 mm distance-to-agreement level. Dose readout from the 3D dosimetry system was found to agree better with independent film measurement than with treatment planning system calculations in penumbral regions and was generally accurate to within 2% dose difference and 2 mm distance-to-agreement. In conclusion, these studies demonstrate excellent precision, accuracy, robustness, and reproducibility of the PRESAGE/optical-CT system for relative 3D dosimetry and support its potential integration with the RPC H and N credentialing phantom for IMRT verification.

61 RADIATION PROTECTION AND DOSIMETRY↗

Intracranial CT angiography obtained from a cerebral CT perfusion examination

CT perfusion (CTP) examinations of the brain are performed increasingly for the evaluation of cerebral blood flow in patients with stroke and vasospasm after subarachnoid hemorrhage. Of the same patient often also a CT angiography (CTA) examination is performed. This study investigates the possibility to obtain CTA images from the CTP examination, thereby possibly obviating the CTA examination. This would save the patient exposure to radiation, contrast, and time. Each CTP frame is a CTA image with a varying amount of contrast enhancement and with high noise. To improve the contrast-to-noise ratio (CNR) we combined all 3D images into one 3D image after registration to correct for patient motion between time frames. Image combination consists of weighted averaging in which the weighting factor of each frame is proportional to the arterial contrast. It can be shown that the arterial CNR is maximized in this procedure. An additional advantage of the use of the time series of CTP images is that automatic differentiation between arteries and veins is possible. This feature was used to mask veins in the resulting 3D images to enhance visibility of arteries in maximum intensity projection (MIP) images. With a Philips Brilliance 64 CT scanner (64x0.625 mm) CTP examinations of eight patients were performed on 80 mm of brain using the toggling table technique. The CTP examination consisted of a time series of 15 3D images (2x64x0.625 mm; 80 kV; 150 mAs each) with an interval of 4 s. The authors measured the CNR in images obtained with weighted averaging, images obtained with plain averaging, and images with maximal arterial enhancement. The authors also compared CNR and quality of the images with that of regular CTA examinations and examined the effectiveness of automatic vein masking in MIP images. The CNR of the weighted averaged images is, on the average, 1.73 times the CNR of an image at maximal arterial enhancement in the CTP series, where the use of plain averaging increases the CNR only with a factor of 1.49. The quality of the weighted averaged images approaches that of CTA images, although in the present study the image quality of CTA was not quite reached. The automatic masking of veins is effective and only small remnants of veins were sometimes present in the masked images. Weighted averaging makes it possible to create CTA images from a CTP examination with a CNR considerably higher than that of images with maximal arterial enhancement. The quality of the resulting images approaches that of CTA images and offers the additional advantages to automatically differentiate between arteries and veins.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pediatric organ dose measurements in axial and helical multislice CT

An anthropomorphic pediatric phantom (5-yr-old equivalent) was used to determine organ doses at specific surface and internal locations resulting from computed tomography (CT) scans. This phantom contains four different tissue-equivalent materials: Soft tissue, bone, brain, and lung. It was imaged on a 64-channel CT scanner with three head protocols (one contiguous axial scan and two helical scans [pitch=0.516 and 0.984]) and four chest protocols (one contiguous axial scan and three helical scans [pitch=0.516, 0.984, and 1.375]). Effective mA s [=(tube currentxrotation time)/pitch] was kept nearly constant at 200 effective mA s for head and 290 effective mA s for chest protocols. Dose measurements were acquired using thermoluminescent dosimeter powder in capsules placed at locations internal to the phantom and on the phantom surface. The organs of interest were the brain, both eyes, thyroid, sternum, both breasts, and both lungs. The organ dose measurements from helical scans were lower than for contiguous axial scans by 0% to 25% even after adjusting for equivalent effective mA s. There was no significant difference (p>0.05) in organ dose values between the 0.516 and 0.984 pitch values for both head and chest scans. The chest organ dose measurements obtained at a pitch of 1.375 were significantly higher than the dose values obtained at the other helical pitches used for chest scans (p<0.05). This difference was attributed to the automatic selection of the large focal spot due to a higher tube current value. These findings suggest that there may be a previously unsuspected radiation dose benefit associated with the use of helical scan mode during computed tomography scanning.

61 RADIATION PROTECTION AND DOSIMETRY↗

Nonlinear registration of serial coronary CT angiography (CCTA) for assessment of changes in atherosclerotic plaque

Purpose: Coronary CT angiography (CCTA) is a high-resolution three-dimensional imaging technique for the evaluation of coronary arteries in suspected or confirmed coronary artery disease (CAD). Coregistration of serial CCTA scans would allow precise superimposition of images obtained at two different points in time, which could aid in recognition of subtle changes and precise monitoring of coronary plaque progression or regression. To this end, the authors aimed at developing a fully automatic nonlinear volume coregistration for longitudinal CCTA scan pairs. Methods: The algorithm combines global displacement and local deformation using nonlinear volume coregistration with a volume-preserving constraint. Histogram matching of intensities between two serial scans is performed prior to nonlinear coregistration with dense nonparametric local deformation in which sum of squared differences is used as a similarity measure. The approximate segmentation of coronary arteries obtained from commercially available software provides initial anatomical landmarks for the coregistration algorithm that help localize and emphasize the structure of interest. To avoid possible bias caused by incorrect segmentation, the authors convolve the Gaussian kernel with the segmented binary coronary tree mask and define an extended weighted region of interest. A multiresolution approach is employed to represent coarse-to-fine details of both volumes and the energy function is optimized using a gradient descent method. The authors applied the algorithm in ten paired CCTA datasets (20 scans in total) obtained within 10.7{+-}5.7 months from each other on a dual source CT scanner to monitor progression of CAD. Results: Serial CCTA coregistration was successful in 9/10 cases as visually confirmed. The global displacement and local deformation of target registration error obtained from four anatomical landmarks were 2.22{+-}1.15 and 1.56{+-}0.74 mm, respectively, and the inverse consistency error of local deformation was 0.14{+-}0.06 mm. The observer variability between two expert observers was 1.31{+-}0.91 mm. Conclusions: The proposed coregistration algorithm demonstrates potential to accurately register serial CCTA scans, which may allow direct comparison of calcified and noncalcified atherosclerotic plaque changes between the two scans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric evaluation of a novel polymer gel dosimeter for proton therapy

Purpose: The aim of this study is to evaluate the dosimetric performance of a newly developed proton-sensitive polymer gel formulation for proton therapy dosimetry. Methods: Using passive scattered modulated and nonmodulated proton beams, the dose response of the gel was assessed. A next-generation optical CT scanner is used as the readout mechanism of the radiation-induced absorbance in the gel medium. Comparison of relative dose profiles in the gel to ion chamber profiles in water is performed. A simple and easily reproducible calibration protocol is established for routine gel batch calibrations. Relative stopping power ratio measurement of the gel medium was performed to ensure accurate water-equivalent depth dose scaling. Measured dose distributions in the gel were compared to treatment planning system for benchmark irradiations and quality of agreement is assessed using clinically relevant gamma index criteria. Results: The dosimetric response of the gel was mapped up to 600 cGy using an electron-based calibration technique. Excellent dosimetric agreement is observed between ion chamber data and gel. The most notable result of this work is the fact that this gel has no observed dose quenching in the Bragg peak region. Quantitative dose distribution comparisons to treatment planning system calculations show that most (>97%) of the gel dose maps pass the 3%/3 mm gamma criterion. Conclusions: This study shows that the new proton-sensitive gel dosimeter is capable of reproducing ion chamber dose data for modulated and nonmodulated Bragg peak beams with different clinical beam energies. The findings suggest that the gel dosimeter can be used as QA tool for millimeter range verification of proton beam deliveries in the dosimeter medium.

61 RADIATION PROTECTION AND DOSIMETRY↗