Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COUNTING RATES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Field Test Report Neutron Scintillator Array Dry Storage Cask Scanner FY2024

During two weeks of Field Testing at the Idaho National Laboratory INTEC Cask Farm in July and August 2024, the LLNL Dry Storage Cask Scanner Array was lifted on top of an MC-10 dry storage fuel cask and operated to acquire neutron and gamma-ray data from the 24 fuel bundle positions. Neutron and gamma-ray data acquisition scans across the top of the cask of varying dwell times were performed July 15-18, 2024 and August 19-22, 2024 to evaluate the ability of the scanner data to reveal asymmetries in the fuel positions that reflect asymmetries in the MC-10 cask fuel bundle loading. The MC-10 cask 24 position fuel bundle loading at the INTEC Cask Farm is well documented, including the locations of six empty fuel bundle positions. This loading presents an opportunity to test the ability of the scanner system to detect diversion of spent fuel bundles as well as to validate the MC-10 cask MCNP modeling. The cask scanner array consists of six Stilbene crystal scintillator detectors and a linear actuator frame that moves the six detectors across the MC-10 dry storage cask to obtain data above each of the 24 fuel bundle positions. The detectors are connected to a pulse-shape discrimination data acquisition system capable of generating separate neutron and gamma-ray spectra for each detector and for each scan position. From the prior single detector Field Test in 2021 and iteration with MCNP modeling, the neutron and gamma-ray data were analyzed in multiple energy regions to identify an analysis method that would provide the strongest and most consistent signature of the asymmetric MC-10 cask fuel loading1 . From both the 2021 Field Test and the current Field Test results, the neutron capture gamma-ray count rate around 2.2 MeV provides the strongest signature of the asymmetric MC-10 cask fuel loading and has qualitative agreement with MCNP calculations. Counting all gamma-rays produces a similar signature. Neutrons emerging from the cask top are moderated and captured by the hydrogen in the polyethylene moderator and scintillator detector, producing a 2.2 MeV gamma ray which is seen in the scintillator gamma-ray spectrum. The count rate in the 2.2 MeV gamma-ray region is ~50 c/s, which is ~1000x higher than the ~0.05 n/s rate in the > 4MeV neutron region, and ~50x greater than the ~1 n/s rate in the neutrons > 500 keV region. Analysis of the 2.2 MeV neutron-capture Compton-scattered gamma-rays produces a statistically significant signature of the INTEC Cask Farm MC-10 asymmetric fuel loading. MCNP simulations indicate that the average neutron energy spectrum offers the potential to detect a large asymmetry from several missing bundles as well as individual missing fuel bundles. Testing this feature will require measurements on a cask with single missing elements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

THE PUZZLING HARMONIC BEHAVIOR OF THE CATHEDRAL QPO IN XTE J1859+226

We present a spectral and temporal analysis of the Cathedral quasi-periodic oscillation (QPO) detected in the power density spectra of the black hole binary and microquasar XTE J1859+226, obtained using Rossi X-Ray Timing Explorer. This type of QPO has been seen on two occasions (MJDs 51574.43 and 51575.43) during the 1998 outburst of this source. It manifests as two peaks with similar amplitudes ({approx}3% and {approx}5% rms) and harmonically related centroid frequencies ({approx}3 and {approx}6 Hz). The temporal properties of these two peaks are different: the amplitude of the {approx}3-Hz feature varies, in anticorrelation with the count rate, by {approx}50%. The {approx}6-Hz feature, on the other hand, shows a slight increase ({approx}7%) in its amplitude with the count rate. The rms spectra of the two peaks are also quite different. The {approx}3-Hz feature is softer than the other one, and, although its rms amplitude increases with energy, it shows a cutoff at an energy of {approx}6 keV. The rms of the {approx}6-Hz feature increases with energies up to at least 20 keV. We also study the bicoherence b{sup 2}({mu}, {nu}) of both observations. At the diagonal position of the peaks, the values b{sup 2}({approx} 3, {approx} 3) and b{sup 2}({approx} 6, {approx} 6) are rather high and similar to those reported for type C QPOs of GRS 1915+105. In comparison with the latter source, the bicoherence of the {approx}3-Hz feature is higher than that of the other peak, which may indicate that the {approx}3-Hz feature is the fundamental QPO and the other is its first harmonic. The value of b{sup 2}({approx} 3, {approx} 6) is, however, very low and therefore indicates a behavior different from that seen in the type C QPO of GRS 1915+105. We discuss the implications of these differences in the context of a harmonic relationship between the peaks, and suggest that, rather than pure harmonics, we may see different modes of the same underlying phenomenon competing to produce QPOs at different frequencies.

79 ASTRONOMY AND ASTROPHYSICS↗

Strategies and limitations for fluorescence detection of XAFS at high flux beamlines

The issue of detecting the XAFS signal from dilute samples is discussed in detail with the aim of making best use of high flux beamlines that provide up to 10 13 photons -1 . Various detection methods are compared, including filters with slits, solid state detectors, crystal analyzers and combinations of these. These comparisons rely on simulations that use experimentally determined parameters. It is found that inelastic scattering places a fundamental limit on detection, and that it is important to take proper account of the polarization dependence of the signals. The combination of a filter–slit system with a solid state detector is a promising approach. With an optimized system good performance can be obtained even if the total count rate is limited to 10 7 Hz. Detection schemes with better energy resolution can help at the largest dilutions if their collection efficiency and count rate limits can be improved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Self-scanned anode array with a microchannel plate electron multiplier - The SSANACON

A photoelectron counting detector utilizing a 128-element linear self-scanned anode array to collect the output of a dual microchannel plate electron multiplier is described. The operation of the detector, its spatial resolution and detection efficiency, and radiation behavior are discussed. The low-noise detector was developed for the Mariner Jupiter/Saturn mission UV spectrometer, and offers a large dynamic range and count rate of 0.003 per anode-sec. It can measure simultaneously two spatially separated signals differing by more than six orders of magnitude in count rate.

Broadfoot, A. L.↗

Neutron detection in a high-gamma field using solution-grown stilbene

We present that a solution-based technique for growing large-volume stilbene scintillators was developed in 2013; crystals up to diameters of 10 cm, or larger, have been grown while preserving excellent pulse shape discrimination (PSD) properties. The goal of this study is to evaluate the PSD capabilities of 5.08 by 5.08-cm stilbene crystals grown by Lawrence Livermore National Laboratory and Inrad Optics when exposed to a 1000 to 1 gamma ray-neutron ratio and operating at a 100-kHz count rate. Results were compared to an equivalent EJ-309 liquid scintillation detector. 252 Cf neutron pulses were recorded in two experiments where 60 Co and 137 Cs sources created the high-gamma field. The high count rate created numerous double pulses that were cleaned using fractional and template approaches designed to remove double pulses while preserving neutron counts. PSD was performed at a threshold of 42 keVee (440-keV proton) for stilbene and 60 keVee (610-keV proton) for EJ-309 liquid. The lower threshold in stilbene resulted in a neutron intrinsic efficiency of approximately 14.5%, 10% higher than EJ-309 liquid, for bare 252 Cf and 13% for 252 Cf in the high-gamma field. Despite the lower threshold, the gamma misclassification rate in stilbene was approximately 3×10 $-$6 , nearly a factor-of-five lower than what we found with the EJ-309 liquid.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Fast Decay-Energy Spectroscopy With Magnetic Microcalorimeters

Decay energy spectroscopy (DES) is an increasingly important radiometric technique arising from the unique thermal detection physics and the precision of low-temperature microcalorimetry. DES can enable high-precision analysis of very small amounts of radioactive material with simple and rapid sample preparation, making it a key new tool for nuclear safeguards, nuclear forensics, the improvement of nuclear data, measurements of absolute activity, and other applications. For problems in nuclear safeguards and nuclear forensics it is highly desirable to increase the count rates achievable in DES, while maintaining simple and rapid sample preparation. Here, in this report, we describe progress in a new project to achieve high count rates in DES by taking advantage of the physics of magnetic microcalorimetry. We describe the results of initial modeling and experiment to validate the idea, a sample fabrication technique suitable for nuclear materials laboratories, the preparation and initial tests of paramagnetic Au-Er alloy in thin foil form, and the development of a sensing coil geometry that will perform well with the increased-thickness sensor used in the new technique.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Developing Laser-Induced Re-Collision Electron Self-Diffraction (Brief summary of accomplishments)

Our principal goal was the experimental demonstration of Laser-Induced Electron Diffraction (LIED). Key steps along the development of this experimental technique have been accomplished and reported in the publications listed in this brief report. We started with measuring 3D electron momenta spectra in aligned nitrogen and oxygen molecules. Chakra Maharjan (Ph.D. student of Lew Cocke) was a lead researcher on this project. Although Chakra succeeded in obtaining those spectra, we were scooped by the publication of identical results in Science by the NRC Ottawa group. Our results were never published as a refereed article, but became a part of Chakra's Ph.D. dissertation. That Science paper was the first experimental demonstration of Laser-Induced Electron Diffraction (LIED). Chakra also worked on wavelength dependence of 3D ATI spectra of atoms and molecules using tunable OPA pulses. Another Ph.D. student, Maia Magrakvelidze (her GRA was funded by the grant), started working on COLTRIMS experiments using OPA pulses (1800 nm wavelength). After some initial experiments it became apparent that COLTRIMS did not yield sufficient count rates of electrons in the high-energy part of the spectrum to see diffraction signatures with acceptable statistics (unfavorable scaling of the electron yield with laser wavelength was partly to blame). Nevertheless, Maia managed to use COLTRIMS and OPA to measure the angular dependence of the tunneling ionization rate in D 2 molecules. Following the initial trial experiments, the decision was made to switch from COLTRIMS to VMI in order to increase the count rates by a factor of ~100, which may have given us a chance to see LIED. Research Associate Dr. Sankar De (his salary was funded by the grant), in collaboration with Matthias Kling's group (then at MPQ Garching), proceeded to design a special multi-electrode VMI spectrometer for capturing high-energy ATI electrons and to install it in place of COLTRIMS inside our experimental chamber. That apparatus was later used for the first demonstration of field-free orientation in CO using two-color laser pulses as well as for a series of other experiments, such as pump-probe studies of molecular dynamics with few-cycle laser pulses, control of electron localization in dissociating hydrogen molecules using two-color laser pulses, and ATI spectra of Xe ionized by two-color laser pulses. In parallel, Dipanwita Ray (Ph.D. student of Lew Cocke) worked on measuring angle-resolved ATI spectra of noble gases using a stereo-ATI phasemeter as a TOF electron spectrometer. She observed the angular diffraction structures in 3D ATI spectra of Ar, Kr and Xe, which were interpreted in terms of the Quantitative Rescattering theory newly developed by C.D. Lin. We also attempted to use a much more powerful OPA (five times more energy per pulse than the one we had at JRML) available at the Advanced Laser Light Source (ALLS) in Montreal to observe LIED. Two visits to ALLS by the PI, Igor Litvinyuk, and one visit by the PI's Ph.D. student (Irina Bocharova) were funded by the grant. Though we failed to observe LIED (the repetition rate of the ALLS OPA was too low at only 100 Hz), this international collaboration resulted in several publications on other related subjects, such as the wavelength dependence of laser Coulomb explosion of hydrogen, the wavelength dependence of non-sequential double ionization of neon and argon, the demonstration of charge-resonance enhanced ionization in CO 2 , and the study of non-elastic scattering processes in H 2 }. Theoretical efforts to account for the hydrogen Coulomb explosion experiment resulted in another paper by Maia Magrakvelidze as lead author. Although for various reasons we failed to achieve our main goal of observing LIED, we salute the recent success in this endeavor by Lou DiMauro's group (with theoretical support from our KSU colleague C.D. Lin) published in Nature, which validates our approach.

08 HYDROGEN↗

Phase space distribution of halo particles and detection of WIMPS

We calculate the velocity distribution of halo particles using realistic models for the density profiles of the Galactic disk, spheroid, and halo components. We get the resulting velocity distribution, which is different from the Maxwellian distribution of isothermal halo. We investigate the consequences concerning the time averaged count rate and the amplitude of the annual modulation in WIMPS detection experiments. Compared to the previous estimate based on the Maxwellian distribution, the time averaged count rate is up to 40 percent larger. On the other hand, the amplitude of the annual modulation is up to a factor of two larger.

Ryu, Dongsu↗

Dead-time effects in microchannel-plate imaging detectors

The observed counting rates of microchannel plate (MCP) based detectors for high resolution observations of celestial EUV and X-ray sources vary over many orders of magnitude; the counting capability of an individual channel, however, is not high, and is associated with dead-times ranging from 0.1 msec to 1 sec. The dead-time increases with the area illuminated; attention is presently given to laboratory determinations of the count rate characteristics of a MCP detector as a function of illuminated area, and a model is developed for these results' use in the interpretation of space observations.

Zombeck, Martin V.↗

POSSIBLE EVIDENCE FOR A FISK-TYPE HELIOSPHERIC MAGNETIC FIELD. I. ANALYZING ULYSSES/KET ELECTRON OBSERVATIONS

The propagation of energetic charged particles in the heliospheric magnetic field is one of the fundamental problems in heliophysics. In particular, the structure of the heliospheric magnetic field remains an unsolved problem and is discussed as a controversial topic. The first successful analytic approach to the structure of the heliospheric magnetic field was the Parker field. However, the measurements of the Ulysses spacecraft at high latitudes revealed the possible need for refinements of the existing magnetic field model during solar minimum. Among other reasons, this led to the development of the Fisk field. This approach is highly debated and could not be ruled out with magnetic field measurements so far. A promising method to trace this magnetic field structure is to model the propagation of electrons in the energy range of a few MeV. Employing three-dimensional and time-dependent simulations of the propagation of energetic electrons, this work shows that the influence of a Fisk-type field on the particle transport in the heliosphere leads to characteristic variations of the electron intensities on the timescale of a solar rotation. For the first time it is shown that the Ulysses count rates of 2.5-7 MeV electrons contain the imprint of a Fisk-type heliospheric magnetic field structure. From a comparison of simulation results and the Ulysses count rates, realistic parameters for the Fisk theory are derived. Furthermore, these parameters are used to investigate the modeled relative amplitudes of protons and electrons, including the effects of drifts.

79 ASTRONOMY AND ASTROPHYSICS↗

Skin contamination dosimeter

A technique and device provides absolute skin dosimetry in real time at multiple tissue depths simultaneously. The device uses a phoswich detector which has multiple scintillators embedded at different depths within a non-scintillating material. A digital pulse processor connected to the phoswich detector measures a differential distribution (dN/dH) of count rate N as function of pulse height H for signals from each of the multiple scintillators. A digital processor computes in real time from the differential count-rate distribution for each of multiple scintillators an estimate of an ionizing radiation dose delivered to each of multiple depths of skin tissue corresponding to the multiple scintillators embedded at multiple corresponding depths within the non-scintillating material.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Einstein X-ray Observatory Catalog of O-type stars

A catalog of X-ray count rates for all O-type stars surveyed by the Einstein Observatory is presented. The procedures by which the IPC and High Resolution Imager rates are converted to emitted X-ray luminosities are discussed in detail. The catalog contains 289 stars with 89 detections and 176 upper bounds for the observed count rates. Precise positions for 43 O-type stars are given whose previously known locations were unknown or erroneous. It is argued that most O-type stars are X-ray point sources, but some are possibly embedded in extended nebulae and/or bubbles. The X-ray spectra of O-type stars are discussed briefly, and it is argued that their mean spectrum can reasonably be taken as an 0.5 keV thermal bremsstrahlung model. It is argued that at least 30 percent of all O-type stars are variable in X-rays.

Chlebowski, T.↗

The scattered solar X-ray background of the ROSAT PSPC

A model for accurately reproducing the light curves and spectra of the scattered solar X-ray background (SB) affecting ROSAT XRT/PSPC pointed observations is presented and demonstrated. This procedure, the modeling and subtraction of the SB, is vital for analysis of all observations of extended X-ray objects and the soft X-ray diffuse background where noncosmic background constituents must be precisely known. At the orbital altitude of ROSAT, about 550 km, and the zenith angles at which the XRT/PSPC observers, 97 deg or less, the scattering is dominated by atomic oxygen with Thomson-scattered X-rays in the 1/4 keV band and oxygen K-alpha fluorescently scattered X-rays at 0.54 keV. This produces field-of-view-integrated minimum count rates in the 0.1-1.0 keV band of about 0.25 counts/s during dayside observations with excursions to about 40 counts/s or more in particularly bad geometries. Typical cosmic background count rates in the same band range from 3 to 12 counts/s, demonstrating the need for the procedure described here.

Snowden, S. L.↗

Preliminary Iron Distribution on Vesta

The distribution of iron on the surface of the asteroid Vesta was investigated using Dawn's Gamma Ray and Neutron Detector (GRaND) [1,2]. Iron varies predictably with rock type for the howardite, eucrite, and diogenite (HED) meteorites, thought to be representative of Vesta. The abundance of Fe in howardites ranges from about 12 to 15 wt.%. Basaltic eucrites have the highest abundance, whereas, lower crustal and upper mantle materials (cumulate eucrites and diogenites) have the lowest, and howardites are intermediate [3]. We have completed a mapping study of 7.6 MeV gamma rays produced by neutron capture by Fe as measured by the bismuth germanate (BGO) detector of GRaND [1]. The procedures to determine Fe counting rates are presented in detail here, along with a preliminary distribution map, constituting the necessary initial step to quantification of Fe abundances. We find that the global distribution of Fe counting rates is generally consistent with independent mineralogical and compositional inferences obtained by other instruments on Dawn such as measurements of pyroxene absorption bands by the Visual and Infrared Spectrometer (VIR) [4] and Framing Camera (FC) [5] and neutron absorption measurements by GRaND [6].

Mittlefehldt, David W.↗

Measurement of Photoneutrons from Depleted Uranium and Comparison Study Using MCNPX-PoliMi

High-energy photon interrogation is a nondestructive technique that is used to detect special nuclear materials and characterize nuclear waste. The development of such systems is complex and requires Monte Carlo simulations to optimize system performance. Monte Carlo simulations rely on various scattering, absorption, and photonuclear cross-section data. While the scattering and absorption cross-section data have been extensively studied and validated with experiments, the results obtained from photonuclear simulations are often found to underpredict measured results, indicating uncertainties in the photonuclear cross sections themselves. Thus, there is a need for new measured results that can be used to quantify underpredictions in simulations using photonuclear cross-section data. In the present work, we interrogated depleted uranium with a 9-MV electron linac and detected photoneutrons with trans-stilbene organic scintillators. The measurement of photoneutrons with organic scintillators is challenging due to the presence of the intense photon flux, which causes issues such as pulse pile-up, detector saturation, and poor signal-to-background ratio. To mitigate these challenges, we used iron and polyethylene shielding of varying thicknesses around the depleted uranium target and a neural network–based digital pulse processing algorithm to recover neutron and photon information from piled-up events. Our goal was to compare the measured photoneutron count rate with the simulated rate obtained using the MCNPX-PoliMi transport code. For a light output window of 0.28 to 2.67 MeVee (1.66- to 6.85-MeV proton recoil energy), we found that the simulated count rate obtained using the ENDF/B-VII photonuclear cross-section library underpredicts the measured rate by 32.8% 3.2%. Additionally, we compared the simulated and measured photoneutron light output distributions. For the least thicknesses of shielding, the simulation was found to underpredict measurements in the 0.70- to 2.67-MeVee light output window. For the greatest thicknesses of shielding, the simulation was found to underpredict the measurement across the entire light output window of 0.28 to 2.67 MeVee.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Tailoring spectral properties for entangled photon generation

The linear intensity scaling of entangled two-photon absorption (ETPA) offers a fundamental mechanism to enable nonlinear optical spectroscopy and microscopy under a substantially lower excitation power than is currently feasible. However, the long data acquisition time and low signal-to-noise ratio in reported ETPA-based spectroscopic and microscopic studies prevent its widespread application. To gain the full potential of this novel quantum light approach, it is essential to optimize entangled photon generation for significantly enhanced ETPA responses. Here, we report a new quantum light source by combining entangled photon generation with free-space femtosecond pump-pulse shaping. Here, through measurements of singles and coincidence counts by varying the patterns applied to a spatial light modulator to control the spectral widths of the pump pulses, we reveal strong dependence of the singles and coincidence count rates as well as their ratios on the spectral widths of pump pulses. An optimal spectral width for the highest ratios between the coincidence photon and the signal or idler photon count rates is also determined. Identification of such optimal spectral widths for entangled photon generation in the presence of postgeneration spectral selection makes this quantum light source a promising choice for ETPA-based spectroscopy and imaging.

Photon pairs & parametric down-conversion↗

Electron-deuteron deep-inelastic scattering with spectator tagging at EIC

We summarize the phenomenological description of electron-deuteron deep-inelastic scattering (DIS) with detection of a nucleon in the nuclear fragmentation region, eD → e' + N + X ("spectator tagging"), at collision energies accessible with an Electron-Ion Collider (EIC), √s eD ~ several 10 GeV. This includes (a) the kinematic variables, differential cross section, conditional structure functions, and phase space elements; (b) a cross section model based on the light-front impulse approximation and an analytic parametrization of the deuteron wave function; (c) counting rate estimates for simulations of cross section measurements and on-shell extrapolation in the recoil nucleon momentum; (d) a FORTRAN 77 code package for computing the cross section and performing counting rate estimates. The document summarizes the definitions and results without derivation and is intended as a reference for programming and simulations.

43 PARTICLE ACCELERATORS↗

Probable detection of solar neutrons by ground-level neutron monitors during STIP interval 16

The third solar neutron event detected by Earth-orbiting spacecraft was observed during STIP Interval XVI. The solar flare beginning at 2356 UT on 24 April l984 produced a variety of emissions including gamma rays and solar neutrons. The neutrons were observed by the SMM satellite and the neutron-decay protons were observed on the ISEE-3 spacecraft. Between 0000 and 0010 UT on 25 April an increase of 0.7 and 1.7 percent was recorded by neutron monitors at Tokyo (Itabashi) and Morioka, Japan. These stations were located about 42 degrees from the sub-solar point, and consequently, these is approximately 1400 grams of atmosphere between the incident neutrons at the top of the atmosphere and their detection on the Earth's surface. Nevertheless, the time coincidence of a small increase in the total counting rate of two independent neutron monitors indicates the presence of solar neutrons with energies greater than 400 MeV at the top of the Earth's atmosphere. The small increases in the counting rate emphasize the difficulty in identifying similar events using historical neutron monitor data.

Shea, M. A.↗