At least 325 records · Page 18

Development of thin wraparound junction silicon solar cells

The state of the art technologies was applied to fabricate 50 micro thick 2x4 cm, coplanar back contact (CBC) solar cells with AMO efficiency above 12%. A requirement was that the cells have low solar absorptance. A wraparound junction (WAJ) with wraparound metallization was chosen. This WAJ approach avoided the need for very complex fixturing, especially during rotation of the cells for providing adequate contacts over dielectric edge layers. The contact adhesion to silicon was considered better than to an insulator. It is indicated that shunt resistance caused by poor WAJ diode quality, and series resistance from the WAJ contact, give good cell performance. The cells developed reached 14 percent AMO efficiency (at 25 C), with solar absorptance values of 0.73. Space/cell environmental tests were performed on these cells and the thin CSC cells performed well. The optimized design configuration and process sequence were used to make 50 deliverable CBC cells. These cells were all above 12 percent efficiency and had an average efficiency of -13 percent. Results of environmental tests (humidity-temperature, thermal shock, and contact adherence) are also given.

Ho, F.↗

A reliable all-silver front contact for silicon solar cells

The feasibility of making an adherent and moisture degradation resistant silver-only front contact to silicon solar cells was demonstrated. Optimum fabrication processes and process sequences were determined for making such contacts. These contacts were found to also have good electrical characteristics. A back contact of aluminum-silver was also developed. This proved very satisfactory for low-temperature applications.

Lamneck, J. H., Jr.↗

Melt Infiltration Studies of 2D Tyranno SA3(R) Ceramic Matrix Composite Preforms with CrSi2 Intermetallic Alloy

The present paper reports the results of melt infiltrating 2D Tyranno SA3@ fiber woven preforms with molten CrSi2 between 1768 and 1896 K under a vacuum of 1.3 x 10-4 Pa (10-6 torr). The infiltration times varied between 1800 and 7200 s, which did not have any significant effect on the volume fraction of voids filled with the metal. Optical and scanning electron microscopy, back scattered electron imaging, energy dispersion spectroscopy and Raman spectroscopy were used to characterize the infiltrated preforms. A plot of the volume fraction of open voids infiltrated against the absolute melt infiltration temperature showed a sharp peak at 1773 K with almost complete infiltration of the voids at this temperature. The extent of silicide infiltration of the preforms dropped steeply above 1773 K with increasing melt infiltration temperature irrespective of the amount of infiltration time. Above 1805 K, the volume fraction of voids infiltrated with the melt was nearly 0%. It is demonstrated that CrSi2 did not show evidence of a reaction with the SiC fibers. The possibility that a resisting force due to contact angle hysteresis (CAH) may have influenced the diminishing amount of voids filled with increasing temperature above 1773 K was examined. The resistance force was estimated to be extremely small to be consequential. Another possibility that the CrSi2 may have decomposed into Cr(g) and Si(g) in the vacuum melt infiltration furnace appeared to be more plausible based on thermodynamic analyses. An empirical equation is proposed to calculate the amount of remaining charge left to infiltrate the preforms at the infiltration temperature. It is shown that an initial charge of 10 g would rationalize the present observations. While the decomposition of the CrSi2 appeared to mostly explain the present results, some discrepancies were observed, which were inconsistent with the decomposition model.

CrSi2, chromium silicide, ceramic matrix composite↗

Friction behavior of glass and metals in contact with glass in various environments

Sliding friction experiments have been conducted for heat-resistant glass and metals in contact with glass. These experiments were conducted in various environments including vacuum, moist air, dry air, octane, and stearic acid in hexadecane. Glass exhibited a higher friction force in moist air than it did in vacuum when in sliding contact with itself. The metals, aluminum, iron, and gold, all exhibited the same friction coefficient when sliding on glass in vacuum as glass sliding on glass. Gold-to-glass contacts were extremely sensitive to the environment despite the relative chemical inertness of gold.

Buckley, D. H.↗

Optimization of tapered busses for solar cell contacts

Some fraction of the power produced by a solar cell is necessarily lost by series resistance associated with the metallized contact grid and by shadowing of cell active area by the grid. There are several approaches to reducing these losses, such as choosing a more efficient pattern, optimizing line spacing, and using tapered buses. The present paper analyzes tapered lines and derives from this analysis a theoretical lower bound to metallization power loss, independent of pattern chosen.

Landis, G. A.↗

Ion Implantatiion Improves Bearing-Surface Properties

Selected ions fired into rolling elements to increase resistance to rolling-contact fatique. Mask strips confine implantation to 105 degree arcs on cylindrical surfaces. Specimens kept cool by copper block through which refrigerant is circulated. Implanting nitrogen or titanium ions in metals improves resistance to fatigue, corrosion, and wear without altering bulk properties. Unlike such surface treatments as conventional nitriding, conventional carburizing, and coating, ion implantation is low-temperature process, requires no finishing operations, and produces highly-alloyed surface layer. Implantation process also helps conserve such strategic materials as chromium and cobalt by using them only where needed.

Misra, M. S.↗

Conduit for high temperature transfer of molten semiconductor crystalline material

A conduit for high temperature transfer of molten semiconductor crystalline material consists of a composite structure incorporating a quartz transfer tube as the innermost member, with an outer thermally insulating layer designed to serve the dual purposes of minimizing heat losses from the quartz tube and maintaining mechanical strength and rigidity of the conduit at the elevated temperatures encountered. The composite structure ensures that the molten semiconductor material only comes in contact with a material (quartz) with which it is compatible, while the outer layer structure reinforces the quartz tube, which becomes somewhat soft at molten semiconductor temperatures. To further aid in preventing cooling of the molten semiconductor, a distributed, electric resistance heater is in contact with the surface of the quartz tube over most of its length. The quartz tube has short end portions which extend through the surface of the semiconductor melt and which are lef bare of the thermal insulation. The heater is designed to provide an increased heat input per unit area in the region adjacent these end portions.

Fiegl, George↗

The Development of a Thermally Enhanced Emergency Fire Shelter

Since its founding in 1905, the U.S. Forest Service has been responsible for maintaining public lands. The Forest Service and other public lands agencies respond to an average of 73,000 wildfires per year, and responding firefighters are required to carry a number of safety gear items, including the M2002 emergency fire shelter. The emergency fire shelter is intended to serve as a last resort means of protection in case a firefighter's escape route has been compromised in the face of an approaching flame front. No fire shelter deployment tragedy has been more costly than the 2013 Yarnell Hill fire in Arizona, where 19 members of the Granite Mountain Hotshots perished. After the tragedy at Yarnell Hill, the Forest Service decided to expedite the next redesign cycle of the fire shelter in order to improve its ability to withstand direct contact with flames. Engineers at NASA Langley Research Center have spent the better part of a decade developing flexible thermal materials for use in inflatable aerodynamic decelerators and have demonstrated their performance in the IRVE-2 and IRVE-3 flight programs (Inflatable Reentry Vehicle Experiment). NASA engineers recognized an opportunity to leverage their experience and knowledge with flexible thermal protection systems to potentially improve the fire shelter's resistance to direct flame contact, and have been working directly with the U.S. Forest Service to achieve this goal. They launched the CHIEFS project (Convective Heating Improvement for Emergency Fire Shelters) in 2014. Over the past three years, CHIEFS has screened over 270 unique material layups, and tested over 30 unique full scale shelter concepts in an effort to achieve a game changing improvement to the thermal protection of the fire shelter, while maintaining minimal mass and volume. This paper will discuss CHIEFS' 1st and 2nd generation fire shelter development efforts and test results.

Fody, Joshua M.↗

Upper limit for magnetoresistance in silicon bronze and phosphor bronze wire

The electrical resistivity of silicon bronze and phosphor bronze was measured in magnetic fields from 0 to 14 T and at temperatures between 2 and 300 K. At any fixed temperature, the change in resistivity to 14 T was less than a few parts in 100,000. Thus, these bronzes are excellent for use in high magnetic fields where constant resistance is required. Welding leads to the sample was found to be superior to soldering. The soldered contacts were subject to spurious resistivity changes that resulted from superconducting transitions in the solder.

Feldman, R.↗

U-Pb ages for sphene in a contact metamorphic zone.

U-Pb ages have been determined on sphene concentrates from the 2700 my old Giants Range Granite at varying distances from the contact with the 1100 my old Duluth gabbro. As the contact is approached the sphene ages become more discordant and plot along a chord between 1100 and 2700 my on a concordia diagram. The U-Pb ages for sphene in the contact aureole are more resistant to thermal metamorphism than are K-Ar ages for hornblende and biotite. The resistance relative to U-Pb ages for zircon is more difficult to interpret because the zircon U-Pb ages may have become discordant prior to or after 1100 my ago, whereas the U-Pb ages for sphene appear to have had episodic discordance only at 1100 my ago.

Hanson, G. N.↗

High-Performance SiC/SiC Ceramic Composite Systems Developed for 1315 C (2400 F) Engine Components

As structural materials for hot-section components in advanced aerospace and land-based gas turbine engines, silicon carbide (SiC) ceramic matrix composites reinforced by high performance SiC fibers offer a variety of performance advantages over current bill-of-materials, such as nickel-based superalloys. These advantages are based on the SiC/SiC composites displaying higher temperature capability for a given structural load, lower density (approximately 30- to 50-percent metal density), and lower thermal expansion. These properties should, in turn, result in many important engine benefits, such as reduced component cooling air requirements, simpler component design, reduced support structure weight, improved fuel efficiency, reduced emissions, higher blade frequencies, reduced blade clearances, and higher thrust. Under the NASA Ultra-Efficient Engine Technology (UEET) Project, much progress has been made at the NASA Glenn Research Center in identifying and optimizing two highperformance SiC/SiC composite systems. The table compares typical properties of oxide/oxide panels and SiC/SiC panels formed by the random stacking of balanced 0 degrees/90 degrees fabric pieces reinforced by the indicated fiber types. The Glenn SiC/SiC systems A and B (shaded area of the table) were reinforced by the Sylramic-iBN SiC fiber, which was produced at Glenn by thermal treatment of the commercial Sylramic SiC fiber (Dow Corning, Midland, MI; ref. 2). The treatment process (1) removes boron from the Sylramic fiber, thereby improving fiber creep, rupture, and oxidation resistance and (2) allows the boron to react with nitrogen to form a thin in situ grown BN coating on the fiber surface, thereby providing an oxidation-resistant buffer layer between contacting fibers in the fabric and the final composite. The fabric stacks for all SiC/SiC panels were provided to GE Power Systems Composites for chemical vapor infiltration of Glenn designed BN fiber coatings and conventional SiC matrices. Composite panels with system B were heat treated at Glenn, and the pores that remained open were filled by silicon melt infiltration (MI). Panels with system A and the other SiC/SiC systems were not heat treated, and remaining open pores in these systems were filled with SiC slurry and silicon MI.

DiCarlo, James A.↗

Ohmic contact for P type indium phosphide

A body including P type indium phosphide has an ohmic contact thereon of an alloy of by weight 81% to 86% gold (Au), 11% to 14% germanium (Ge) and 2% to 5% zinc (Zn). This contact has a low resistance and good adhesion to the indium phosphide body.

Hawrylo, Frank Z.↗

A Study on the Effects of Ball Defects on the Fatigue Life in Hybrid Bearings

Hybrid ball bearings using silicon nitride ceramic balls with steel rings are increasingly being used in space mechanism applications due to their high wear resistance and long rolling contact fatigue life. However, qualitative and quantitative reports of the effects of ball defects that cause early fatigue failure are rare. We report on our approach to study these effects. Our strategy includes characterization of defects encountered in use, generation of similar defects in a laboratory setting, execution of full-scale bearing tests to obtain lifetimes, post-test characterization, and related finite-element modeling to understand the stress concentration of these defects. We have confirmed that at least one type of defect of appropriate size can significantly reduce fatigue life. Our method can be used to evaluate other defects as they occur or are encountered.

Tang, Ching-Yao↗

Understanding Thermal Transport in Polymer –Silver Nanowire Composites

Understanding thermal transport across filler-polymer interfaces and filler-filler contacts within polymer composites is of great importance for better thermal design of the composites that are widely used in high-performance heat exchangers, energy storage devices, and flexible electronics. Over the past several decades, considerable progress has been made in improving the thermal conductivity of polymer composites, but several key questions concerning the influence of interfacial thermal resistance, or Kapitza resistance, still remain. Firstly, the thermal properties of these composites are highly dependent on thermal transport through the filler network and its contacts. For metallic nanofillers, the thermal conductivity is often estimated using the Wiedemann-Franz law based on electrical conductivity; however, it remains a question whether the Wiedemann-Franz law still holds at nanoscale contacts. Through investigation of silver nanowires of varying sizes, we were able to demonstrate that the Lorenz number for silver nanowire increases with decreasing nanowire diameter. Examination of the corresponding electrical and thermal conductivities indicate that these changes are due to that the relative contribution of phonons becomes more significant as a result of elastic stiffening. Furthermore, we show that for silver nanowires, the contact thermal resistance is ~8 times lower than that of multi-walled carbon nanotube (MWCNT) of similar diameters. Additionally, through systematic studies of electrospun polymer-silver nanowire composite nanofibers, we investigated the impact of interface morphology on the thermal conductivity enhancement of the composite system and probed the value of the Kapitza resistance for individual polymer-filler interfaces. For polymer nanofibers containing continuous, single silver nanowires, the thermal conductivity increases linearly with increasing volume fraction of silver, which is consistent with the prediction of percolation theory for samples above the percolation limit. By comparing this linear trend to the measured thermal conductivities of composite nanofibers with more complex structures, we were able to determine the resistance associated with any additional polymer-filler boundaries. In doing so we find that the thermal boundary resistance for polyvinylpyrrolidone (PVP)–silver interfaces is significantly lower than that of comparable polymer-MWCNT composite systems.Together our studies provide new insights into thermal transport in polymer nanocomposites and should help facilitate the design of high performance polymeric thermal interface material.

Thermal transport↗

Silicon switching transistor with high power and low saturation voltage

Assembly of two individually encapsulated silicon-chip transistors produces silicon power-transistor that has low electrical resistance and low thermal impedance. Electrical resistance and thermal impedance are low because of short lead lengths, and external contact surfaces are plated to reduce resistance at interfaces.

Stonebraker, E.↗

Design and fabrication of wraparound contact silicon solar cells

Both dielectric insulation and etched junction contact techniques were evaluated for use in wraparound contact cell fabrication. Since a suitable process for depositing the dielectrics was not achieved, the latter approach was taken. The relationship between loss of back contact and power degradation due to increased series resistance was established and used to design a simple contact configuration for 10 ohm-cm etched wraparound junction contact N/P cells. A slightly deeper junction significantly improved cell curve shape and the associated loss of current was regained by using thinner contact grid fingers. One thousand cells with efficiencies greater than 10.5% were fabricated to demonstrate the process.

Scott-Monck, J. A.↗