Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONNECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Hermetic edge-connect headers and corresponding connectors

A hermetically-sealed edge-connect header that can withstand high temperatures, high pressures (or high vacuum levels), and high vibration environments, along with two corresponding connectors are disclosed. After brazing the edge-connect header components, the assembly is machined to form a slot with a portion of each of a plurality of electrical conductors removed in the machining process, resulting in a header with a high pin density. During the process of mating the first connector design to the edge-connect header, a plurality of wipers in the connector deflect, thereby causing the wipers to extend from the connector and contact the corresponding electrical conductors in the header. During the process of mating the second connector design to the edge-connect header, each of a plurality of wipers formed of low-mass, compliant metal wool, forms multiple contact points with a corresponding electrical conductor in the header.

Kellogg, Rick A.↗

Connecting Electric Vehicle Charging Infrastructure to Commercial Buildings

Electric vehicles (EVs) are growing in popularity and gaining meaningful market share with record sales year over year in the last decade. EV charging equipment, also known as EV chargers (EVC) or EV supply equipment (EVSE), must proportionally match the growing number of new EVs on the road for a comparable experience to gas-powered vehicles. The majority of EV charging currently happens at residential buildings. However, demand for EV charging at commercial buildings will significantly increase with wider mainstream EV adoption and as businesses return to more normal operation following COVID-19 pandemic disruptions. Charging equipment can include various sub-systems like power conditioning module, control software, safety devices, metering, communication, cooling, connectors, and its wiring. EV charging at commercial buildings could be used for public, workplace, and commercial fleet charging. This document aims to describe how EVC can be connected to commercial buildings, including considerations for facility managers, and the effects that charging will have on the buildings electrical distribution system. More specifically, this resource provides an overview of: understanding EV charging basics: how charging equipment connects to the building and to EVs; required infrastructure updates needed at the building site to connect EVC to existing distribution systems; network strategies for cost-effective operation; metering and utility considerations for billing and incentives; charging equipment ownership options; future trends in EVC connection to buildings.

ADVANCED PROPULSION SYSTEMS,ENERGY CONSERVATION, C↗

Hermetic edge-connect headers and corresponding connectors

A hermetically-sealed edge-connect header that can withstand high temperatures, high pressures (or high vacuum levels), and high vibration environments, along with two corresponding connectors are disclosed. After brazing the edge-connect header components, the assembly is machined to form a slot with a portion of each of a plurality of electrical conductors removed in the machining process, resulting in a header with a high pin density. During the process of mating the first connector design to the edge-connect header, a plurality of wipers in the connector deflect, thereby causing the wipers to extend from the connector and contact the corresponding electrical conductors in the header. During the process of mating the second connector design to the edge-connect header, each of a plurality of wipers formed of low-mass, compliant metal wool, forms multiple contact points with a corresponding electrical conductor in the header.

Kellogg, Rick A.↗

A series of pure inorganic eight-connected self-catenated network based on Silverton-type polyoxometalate

In this paper, three pure inorganic eight-connected self-catenated networks based on the Silverton-type polyoxometalate [CeMo{sub 12}O{sub 42}]{sup 8-} with lanthanide, transition metal and alkali metal cations as linkers: [Li(H{sub 2}O){sub 4}]{sub 2}Co(H{sub 2}O){sub 4}Ce(H{sub 2}O){sub 3}[CeMo{sub 12}O{sub 42}].3H{sub 2}O (1), H{sub 0.5}[Li(H{sub 2}O){sub 4}]{sub 2.5}[Ni(H{sub 2}O){sub 4}]{sub 0.5}Ce(H{sub 2}O){sub 3}[CeMo{sub 12}O{sub 42}].3H{sub 2}O (2) and H[Li(H{sub 2}O){sub 4}]{sub 3}Ce(H{sub 2}O){sub 3}[CeMo{sub 12}O{sub 42}].3H{sub 2}O (3) have been successfully synthesized and characterized by elemental analysis, IR spectroscopy, thermal gravimetric analysis, X-ray photoelectron spectroscopy, electrochemical analyses and single crystal X-ray diffraction. The single crystal X-ray diffraction analyses reveal that compounds 1-3 are isostructural. The [Ce{sup IV}Mo{sub 12}O{sub 42}]{sup 8-} polyoxoanions are connected by Ce{sup 4+} to form the infinite 1D chains. And then the parallel stacking chains linked by transition metal cations and lithium ions construct to an eight-connected self-catenated 4{sup 24}56{sup 3} topology framework. - Graphical Abstract: Three extended frameworks based on Silverton-type polyoxometalate have been successfully synthesized. In these compounds, [Ce{sup IV}Mo{sub 12}O{sub 42}]{sup 8-} clusters are connected by lanthanide, transition metal and Li{sup +} to form a 4{sup 24}56{sup 3} network.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dispatching Grid-Forming Inverters in Grid-Connected and Islanded Mode: Preprint

This paper explores the dispatch-ability of grid-forming (GFM) inverters in grid-connected and islanded mode. Grid-forming (GFM) inverters usually use droop control to automatically share power with other GFM sources (inverters and synchronous generator (SG)) and follow the change of the load demand. However, they can be dispatched like their grid-following (GFL) counterparts to output the target active and reactive power. This will help the grid operator better manage their inverter-based resources (IBRs) for improved operation efficiency and reliability. Therefore, this paper proposes an innovative concept of dispatching GFM sources (inverters and SG) to output the target power for both grid-connected and islanded mode by adjusting their droop intercepts. The fundamental principle of doing so is that the GFM inverter's active and reactive power is dictated by its frequency and voltage, thus, dispatching active and reactve power of a GFM inverter can be achieved through dispatching its frequency and voltage. Moreover, the concept distinguishes the dispatch rules for grid-connected and islanded mode. Finally, the concept is validated with an example microgrid system with two GFM inverters, one diesel generator, one grid-following inverter and loads in both grid-connected and islanded mode. This pioneering work results in a practical guidance for power system energy management system (EMS) development to control a future grid with GFM and GFL inverters.

droop control↗

Connecting Galaxies, Halos, and Star Formation Rates Across Cosmic Time

A simple, observationally-motivated model is presented for understanding how halo masses, galaxy stellar masses, and star formation rates are related, and how these relations evolve with time. The relation between halo mass and galaxy stellar mass is determined by matching the observed spatial abundance of galaxies to the expected spatial abundance of halos at multiple epochs--i.e. more massive galaxies are assigned to more massive halos at each epoch. This 'abundance matching' technique has been shown previously to reproduce the observed luminosity- and scale-dependence of galaxy clustering over a range of epochs. Halos at different epochs are connected by halo mass accretion histories estimated from N-body simulations. The halo-galaxy connection at fixed epochs in conjunction with the connection between halos across time provides a connection between observed galaxies across time. With approximations for the impact of merging and accretion on the growth of galaxies, one can then directly infer the star formation histories of galaxies as a function of stellar and halo mass. This model is tuned to match both the observed evolution of the stellar mass function and the normalization of the observed star formation rate--stellar mass relation to z {approx} 1. The data demands, for example, that the star formation rate density is dominated by galaxies with M{sub star} {approx} 10{sup 10.0-10.5} M{sub {circle_dot}} from 0 < z < 1, and that such galaxies over these epochs reside in halos with M{sub vir} {approx} 10{sup 11.5-12.5} M{sub {circle_dot}}. The star formation rate--halo mass relation is approximately Gaussian over the range 0 < z < 1 with a mildly evolving mean and normalization. This model is then used to shed light on a number of issues, including (1) a clarification of 'downsizing', (2) the lack of a sharp characteristic halo mass at which star formation is truncated, and (3) the dominance of star formation over merging to the stellar build-up of galaxies with M{sub star} {approx}< 10{sup 11}M{sub {circle_dot}} at z < 1.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design and dispatch optimization of packaged ice storage systems within a connected community

The traditional implementation of cool thermal energy storage (CTES) must be reimagined within the context of a dynamic grid and smart buildings operating as connected communities. As most buildings do not operate central chillers or connect to district cooling loops, this necessitates a broader use of packaged CTES. Our objective is to begin answering the question of how such packaged CTES should be implemented within a connected community. We do so by presenting a simulation–optimization workflow employing building energy modeling software and a mixed-integer linear program to design and dispatch a packaged CTES technology to achieve minimum total annual cost. We demonstrate this methodology on a seven-building case study using current utility rates and find that total annual cooling energy costs can be reduced by 17.8% compared to baseline, after accounting for the cost of storage. We perform three parametric sensitivity studies to evaluate modeling assumptions and obtain the prioritization of storage procurement as a function of annualized life-cycle cost of storage. We find that a community optimization approach provides significantly different results than individual building optimizations and provides greater savings compared to baseline.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The cross-aisle seismic performance of storage rack base connections

Steel storage racks used in retail stores and warehouses are seismically designed as moment resisting frames in the down-aisle direction, and braced frames in the cross-aisle direction. While their down-aisle response is relatively well understood, there is little understanding of their cross-aisle response, especially as it pertains to the desired mode of inelastic deformation and associated design methods. In this paper, results are presented from six full scale tests on braced frames representing storage racks in the cross-aisle direction. These tests investigate the base plate thickness and dimensions, and the upright (column) cross section. The experiments indicate that inelastic deformation in the base plate provides stable hysteretic response with significant ductility and energy dissipation. Ductile tearing is also observed in welds connecting the base plate to the upright. However, it does not appear to negatively influence the hysteretic response. The tests are complemented by Finite Element (FE) simulations of the base connections. These simulations provide insights into internal force distributions within the connections. Based on these insights, analytical equations are proposed for characterizing the backbone curve of the hysteretic response, for use in displacement based design methods. It is determined that the current approach for characterizing design forces in the anchors is unconservative, since it does not incorporate the effects of strain hardening or the membrane action as the base plate undergoes large deformations. A new approach which incorporates these phenomena is presented, and determined to be significantly more accurate. Finally, limitations of the study are outlined and directions for future work are identified.

36 MATERIALS SCIENCE↗

At the interfaces of the hydrologic sciences: Connecting water, elements, ecosystems, and people through the major contributions of Dr. Emily Bernhardt

Here, in this paper, we describe the major contributions of Professor Emily Bernhardt to the hydrologic sciences. Dr. Bernhardt’s work addresses how carbon, nutrient, and contaminant dynamics respond to a wide range of environmental perturbations that alter hydrologic dynamics within and connectivity among ecosystems. Her research leverages intensive and extensive field sampling, experimental manipulations, macroscale data harmonization and exploration, and continental to global-scale synthesis activities to uncover key drivers and patterns of the impacts human perturbations have on water and elemental cycles. Dr. Bernhardt’s research program is defined by her ability to ask questions and use approaches that explicitly consider connectivity and interfaces in a variety of ways. Here, we highlight significant contributions from Dr. Bernhardt’s work, organized by connectivity, interfaces, and interactions among and across (1) elemental cycles, (2) ecosystems, (3) watersheds, (4) scales, and (5) disciplines. We conclude with a section on Dr. Bernhardt’s impact on the hydrologic sciences and beyond through her exceptional dedication to mentorship, engagement, and service.

58 GEOSCIENCES↗

Parallel algorithms for finding connected components using linear algebra

Finding connected components is one of the most widely used operations on a graph. Optimal serial algorithms for the problem have been known for half a century, and many competing parallel algorithms have been proposed over the last several decades under various different models of parallel computation. This paper presents a class of parallel connected-component algorithms designed using linear-algebraic primitives. These algorithms are based on a PRAM algorithm by Shiloach and Vishkin and can be designed using standard GraphBLAS operations. Here, we demonstrate two algorithms of this class, one named LACC for Linear Algebraic Connected Components, and the other named FastSV which can be regarded as LACC’s simplification. With the support of the highly-scalable Combinatorial BLAS library, LACC and FastSV outperform the previous state-of-the-art algorithm by a factor of up to 12x for small to medium scale graphs. For large graphs with more than 50B edges, LACC and FastSV scale to 4K nodes (262K cores) of a Cray XC40 supercomputer and outperform previous algorithms by a significant margin. This remarkable performance is accomplished by (1) exploiting sparsity that was not present in the original PRAM algorithm formulation, (2) using high-performance primitives of Combinatorial BLAS, and (3) identifying hot spots and optimizing them away by exploiting algorithmic insights.

97 MATHEMATICS AND COMPUTING↗

Tau covariance patterns in Alzheimer's disease patients match intrinsic connectivity networks in the healthy brain

According to the network model of neurodegeneration, the spread of pathogenic proteins occurs selectively along connected brain regions. We tested in vivo whether the distribution of filamentous tau (measured with [ 18 F]flortaucipir-PET), fibrillar amyloid-β ([ 11 C]PIB-PET) and glucose hypometabolism ([ 18 F]FDG-PET) follows the intrinsic functional organization of the healthy brain. We included 63 patients with Alzheimer's disease (AD; 30 male, 63 ± 8 years) who underwent [ 18 F]flortaucipir, [ 11 C]PIB and [ 18 F]FDG PET, and 1000 young adults (427 male, 21 ± 3 years) who underwent task-free fMRI. We selected six predefined disease epicenters as seeds for whole-brain voxelwise covariance analyses to compare correlated patterns of tracer uptake across AD patients against fMRI intrinsic connectivity patterns in young adults. We found a striking convergence between [18F]flortaucipir covariance patterns and intrinsic connectivity maps (range Spearman rho's: 0.32-0.78, p < .001), which corresponded with expected functional networks (range goodness-of-fit: 3.8-8.2). The topography of amyloid-β covariance patterns was more diffuse and less network-specific, while glucose hypometabolic patterns were more spatially restricted than tau but overlapped with functional networks. These findings suggest that the spatial patterns of tau and glucose hypometabolism observed in AD resemble the functional organization of the healthy brain, supporting the notion that tau pathology spreads through circumscribed brain networks and drives neurodegeneration.

60 APPLIED LIFE SCIENCES↗

Effect of heat treatments on superconducting properties and connectivity in K-doped BaFe2As2

Abstract Fe-based superconductors and in particular K-doped BaFe 2 As 2 (K-Ba122) are materials of interest for possible future high-field applications. However the critical current density ( J c ) in polycrystalline Ba122 is still quite low and connectivity issues are suspected to be responsible. In this work we investigated the properties of high-purity, carefully processed, K-Ba122 samples synthesized with two separate heat treatments at various temperatures between 600 and 825 °C. We performed specific heat characterization and T c -distribution analysis up to 16 T and we compared them with magnetic T c and J c characterizations, and transmission-electron-microscopy (TEM) microstructures. We found no direct correlation between the magnetic T c and J c , whereas the specific heat T c -distributions did provide valuable insights. In fact the best J c -performing sample, heat treated first at 750 °C and then at 600 °C, has the peak of the T c -distributions at the highest temperatures and the least field sensitivity, thus maximizing H c2 . We also observed that the magnetic T c onset was always significantly lower than the specific heat T c : although we partially ascribe the lower magnetization T c to the small grain size (< λ , the penetration depth) of the K-Ba122 phase, this behaviour also implies the presence of some grain-boundary barriers to current flow. Comparing the T c -distribution with J c , our systematic synthesis study reveals that increasing the first heat treatment above 750 °C or the second one above 600 °C significantly compromises the connectivity and suppresses the vortex pinning properties. We conclude that high-purity precursors and clean processing are not yet enough to overcome all J c limitations. However, our study suggests that a higher temperature T c -distribution, a larger H c2 and a better connectivity could be achieved by lowering the second heat treatment temperature below 600 °C thus enhancing, as a consequence, J c .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Control system design and stability analysis for a three phase SiC-based Filter-less grid-connected PV inverter

In this paper, a control system of a filter-less grid-connected SiC inverter is designed. Stability analysis has been researched with a focus on grid disturbance rejection. The analysis shows that the conventional control method with instantaneous grid voltage feedforward (IGVF) will significantly limit the bandwidth or stability margin of a filter-less grid-connected inverter, thus make the inverter sensitive to grid disturbance. Two proposed grid voltage feedforward control methods, which require little additional computation resources, are presented to suppress the grid voltage disturbance. The design methods of control parameters are derived. The effects of the proposed feedforward methods are also compared with that of conventional IGVF. Lastly, the grid-connected experimental results of a three phase SiC based filter-less PV inverter are provided to verify and compare the proposed control methods.

30 DIRECT ENERGY CONVERSION↗

Distribution-Connected PV's Response to Voltage Sags at Transmission-Scale

The ever increasing amount of residential- and commercial-scale distribution-connected PV generation being installed and operated on the U.S.'s electric power system necessitates the use of increased fidelity representative distribution system models for transmission stability studies in order to ensure the continued safe and reliable operation of the grid. This paper describes a distribution model-based analysis that determines the amount of distribution-connected PV that trips off-line for a given voltage sag seen at the distribution circuit's substation. Such sags are what could potentially be experienced over a wide area of an interconnection during a transmission-level line fault. The results of this analysis show that the voltage diversity of the distribution system does cause different amounts of PV generation to be lost for differing severity of voltage sags. The variation of the response is most directly a function of the loading of the distribution system. At low load levels the inversion of the circuit's voltage profile results in considerable differences in the aggregated response of distribution-connected PV Less variation is seen in the response to specific PV deployment scenarios, unless pushed to extremes, and in the total amount of PV penetration attained. A simplified version of the combined CMPLDW and PVD1 models is compared to the results from the model-based analysis. Furthermore, the parameters of the simplified model are tuned to better match the determined response. The resulting tuning parameters do not match the expected physical model of the distribution system and PV systems and thus may indicate that another modeling approach would be warranted.

14 SOLAR ENERGY↗

Exactness of OPF Relaxation on Three-phase Radial Networks with Delta Connections

Simulations have shown that while semi-definite relaxations of AC optimal power flow (AC-OPF) on three-phase radial networks with only wye connections tend to be exact, the presence of delta connections seem to render them inexact. This paper shows that such inexactness originates from the non-uniqueness of relaxation solutions and numerical errors amplified by the non-uniqueness. This finding motivates two algorithms to recover the exact solution of AC-OPF in unbalanced distribution networks featuring both wye and delta connections. In simulations using IEEE 13, 37 and 123-bus systems, the proposed algorithms provide exact optimal solutions up to numerical precision.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SMART Mobility. Connected and Automated Vehicles Capstone Report

The U.S. Department of Energy’s Systems and Modeling for Accelerated Research in Transportation (SMART) Mobility Consortium is a multiyear, multi-laboratory collaborative, managed by the Energy Efficient Mobility Systems Program of the Office of Energy Efficiency and Renewable Energy, Vehicle Technologies Office, dedicated to further understanding the energy implications and opportunities of advanced mobility technologies and services. The first three-year research phase of SMART Mobility occurred from 2017 through 2019 and included five research pillars: Connected and Automated Vehicles, Mobility Decision Science, Multi-Modal Freight, Urban Science, and Advanced Fueling Infrastructure. A sixth research thrust integrated aspects of all five pillars to develop a SMART Mobility Modeling Workflow to evaluate new transportation technologies and services at scale. This report summarizes the work of the Connected and Automated Vehicles (CAVs) Pillar. This Pillar investigated the energy, technology, and usage implications of vehicle connectivity and automation and identified efficient CAV solutions. For information about the other Pillars and about the SMART Mobility Modeling Workflow, please refer to the relevant Pillar’s Capstone Report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Distributed Wind Turbine Controls Series: Part 3-Wind Energy in Grid-Connected Deployments – Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL)

In recent years the technical ability and requirement for distributed wind turbines to provide grid support services beyond maximum energy production has increased. Ancillary services leveraged through advance controls of a wind turbine support grid reliability and resilience. One ancillary service that is significant to a grid-connected wind turbine deployment is fault ride through (FRT) in response to the voltage and frequency events in the power system. As part of the Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL) this paper demonstrates, through desktop simulations, the wind turbine's FRT capabilities to support stable grid operation. We establish that the wind turbine models exceed FRT performance requirements stipulated in IEEE 1547-2018, regarding interconnection and interoperability of distributed energy resources. Utilizing a standalone CART2 (600 kW) wind turbine connected to the NREL's Flatirons Campus grid, we study voltage and frequency FRT utilizing various test cases. One of the test cases under study is a Category III voltage fault defined in IEEE 1547-2018 and derived from CA Rule 21. Some distributed wind turbines were unable to connect to the grid following the Rule 21 enforcement in California. Even if this is not a general requirement elsewhere, the grid codes might evolve in this direction. This study illustrates how a distributed wind turbine can provide some of these FRT services and enable a pathway toward a higher contribution of renewable energy in a distribution grid.

17 WIND ENERGY↗

Energy-Efficient Maneuvering of Connected and Automated Vehicles (CAVs) with Situational Awareness at Intersections (Final Progress Report)

The increased development of Connected and Automated Vehicle (CAV) systems, currently used for safety and driver convenience, presents new opportunities to improve the energy efficiency of vehicles. Southwest Research Institute (SwRI) achieved a 20% energy consumption reduction in a 2017 Toyota Prius Prime plug-in hybrid by using connectivity (V2V, V2I, V2X) as part of the Next Generation Energy Technologies for Connected and Automated on-Road Vehicles (NEXTCAR) program. The energy consumption gains were achieved by a combination of vehicle dynamics and powertrain control algorithms with a focus on SAE L1 and L2 automated vehicles where a human is still responsible for safe operation. SwRI is now involved in NEXTCAR-II, focusing on energy-efficient control tech for SAE Level 4/5 automated vehicles, aiming for a 30% energy reduction compared to stock hybrids. The rise of Mobility as a Service (MaaS) is driving investments in L4 and L5 automated vehicles. A study by the University of Michigan shows these vehicles might increase energy use and emissions by 3-20%. Technology similar to NEXTCAR can enhance energy efficiency in highly automated vehicles, leveraging improved sensing and actuation capabilities. While the NEXTCAR programs targeted energy efficiency improvements for a single vehicle, this program adopts a more expansive approach. It places its focus on understanding and testing the cumulative effects within a region or corridor, aiming to assess how a subset of vehicles equipped with NEXTCAR-style technologies influence the overall energy consumption of all vehicles traveling within that area. Additionally, the program explores infrastructure-based mobility solutions to optimize efficiency, and seeks to understand and quantify public perception and likelihood of technology adoption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗