Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Mock light-cones and theory friendly catalogues for the CANDELS survey

Here we present mock catalogues created to support the interpretation of the Cosmic Assembly Near-IR Deep Extragalactic Legacy Survey (CANDELS). We extract haloes along past light-cones from the Bolshoi Planck dissipationless N-body simulations and populate these haloes with galaxies using two different independently developed semi-analytic models of galaxy formation and the empirical model UNIVERSEMACHINE. Our mock catalogues have geometries that encompass the footprints of observations associated with the five CANDELS fields. In order to allow field-to-field variance to be explored, we have created eight realizations of each field. In this paper, we present comparisons with observable global galaxy properties, including counts in observed frame bands, luminosity functions, colour–magnitude distributions and colour–colour distributions. We additionally present comparisons with physical galaxy parameters derived from SED fitting for the CANDELS observations, such as stellar masses and star formation rates. We find relatively good agreement between the model predictions and CANDELS observations for luminosity and stellar mass functions. We find poorer agreement for colours and star formation rate distributions. All of the mock light-cones as well as curated ‘theory friendly’ versions of the observational CANDELS catalogues are made available through a web-based data hub.

79 ASTRONOMY AND ASTROPHYSICS↗

Discovery of an edge-on galaxy with X-shaped bi-cone – SDSS J171359.00+333625.5

ABSTRACT Using the integral field unit (IFU) data from Mapping Nearby Galaxies at Apache Point Observatory (MaNGA) survey, we study the kinematics of gas and stellar components in an edge-on Seyfert 2 galaxy, SDSS J171359.00+333625.5, with X-shaped bi-conical outflows. The gas and stars therein are found to be counter-rotating, indicating that the collision between the inner and external gas might be an effective way to dissipate the angular momentum, which leads to remarkable gas accretion into the galaxy centre. Large [O iii]λ5007 equivalent width and AGN-like line ratio in the large bi-conical region suggest that the gas is ionized by the central AGN. The gas velocity in the bi-cone region shows that ionized gas is receding relative to the galaxy centre, which could be the joint effect of inflows, outflows, and disc rotation. We are probably witnessing the case where a great amount of gas in the disc is being efficiently accreted into the central black hole, and the AGN-driven galactic winds are blown out along the bi-cone. The kinematics of oxygen, including rotation velocity and velocity dispersion, is different from other elements, like hydrogen, nitrogen, and sulphur. The rotation velocity estimated from oxygen is slower than from other elements. The velocity dispersion of other elements follows galactic gravitational potential, while the velocity dispersion of oxygen stays roughly constant along the galactic major-axis. The further advanced observations, e.g. of cold gas or with an IFU of higher spatial resolution, are required to better understand this object.

Bao, Min↗

Tensor-polarized parton density in the 𝑁 → Δ transition from the large-𝑁 𝑐 light-cone wave function

The tensor-polarized parton density is defined by the forward matrix element of a partonic operator in the 𝑁 → Δ transition. In this work, we investigate it by employing the large-𝑁 𝑐 light-cone wave function derived from the mean-field approach. The mean-field picture is based on low-energy effective dynamics in the large-𝑁 𝑐 limit, where the baryon wave function is formulated in the rest frame. By exploiting the covariance of the mean-field solution, we derive the corresponding large-𝑁 𝑐 light-cone wave function—decomposed unambiguously into 3⁢𝑄 , 5⁢𝑄 , 7⁢𝑄 , and higher Fock components—in the infinite momentum frame. Evaluating the overlap of these wave functions, we derive an overlap representation of the tensor-polarized parton density in the 𝑁 → Δ transition and find that the leading contribution arises from the 5⁢𝑄 Fock sector. This indicates that the tensor-polarized parton density directly probes the genuine 5⁢𝑄 component and is governed by chiral dynamics. Our numerical analysis shows that the 𝑁 → Δ tensor-polarized parton density is suppressed, consistent with standard large-𝑁 𝑐 expectations. Finally, we establish connections among the tensor-polarized parton density, the generalized parton distribution 𝐻 𝑋 , and the energy-momentum tensor form factor 𝐹 4 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Thermalization and light cones in a model with weak integrability breaking

Here, we employ equation-of-motion techniques to study the nonequilibrium dynamics in a lattice model of weakly interacting spinless fermions. Our model provides a simple setting for analyzing the effects of weak integrability-breaking perturbations on the time evolution after a quantum quench. We establish the accuracy of the method by comparing results at short and intermediate times to time-dependent density matrix renormalization group computations. For sufficiently weak integrability-breaking interactions we always observe prethermalization plateaus , where local observables relax to nonthermal values at intermediate time scales. At later times a crossover towards thermal behavior sets in. We determine the associated time scale, which depends on the initial state, the band structure of the noninteracting theory, and the strength of the integrability-breaking perturbation. Our method allows us to analyze in some detail the spreading of correlations and in particular the structure of the associated light cones in our model. We find that the interior and exterior of the light cone are separated by an intermediate region, the temporal width of which appears to scale with a universal power law t 1/3 .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Gap between holographic and quantum mechanical extreme rays of the subadditivity cone

We show via explicit construction that for six or more parties, there exist extreme rays of the subadditivity cone that can be realized by quantum states, but not by holographic states. This is a counterexample to a conjecture first formulated in Hernández-Cuenca et al. [The holographic entropy cone from marginal independence, J. High Energy Phys. 09 (2022) 190.], and implies the existence of deep holographic constraints that restrict the allowed patterns of independence among various subsystems beyond the universal quantum mechanical restrictions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Holographic entropy cone beyond AdS/CFT

We extend all known area inequalities obeyed by Ryu-Takayanagi surfaces of anti–de Sitter boundary regions—the holographic entropy cone—to static generalized entanglement wedges of bulk regions in arbitrary spacetimes. The generalized holographic entropy cone is subject to a mutual independence condition on the bulk regions: each bulk input region must be outside the entanglement wedge of the union of all others. The condition captures when gravitating regions involve fundamentally distinct degrees of freedom despite the nonlocality inherent in the holographic principle.

Quantum gravity↗

Orbital structure of quarks inside the nucleon in the light-cone diquark model

We study the orbital angular momentum structure of the quarks inside the proton. By employing the light-cone diquark model and the overlap representation formalism, we calculate the chiral-even generalized parton distribution functions H{sub q}(x,{xi},{Delta}{sup 2}), H-tilde{sub q}(x,{xi},{Delta}{sup 2}), and E{sub q}(x,{xi},{Delta}{sup 2}) at zero skewedness for q=u and d quarks. In our model, E{sub u} and E{sub d} have opposite sign with similar size. Those generalized parton distribution functions are applied to calculate the orbital angular momentum distributions, showing that L{sub u}(x) is positive, while L{sub d}(x) is consistent with zero compared with L{sub u}(x). We introduce the impact parameter dependence of the quark orbital angular momentum distribution. It describes the position space distribution of the quark orbital angular momentum at given x. We found that the impact parameter dependence of the quark orbital angular momentum distribution is axially symmetric in the light-cone diquark model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Limitation on Prepulse Level for Cone-Guided Fast-Ignition Inertial Confinement Fusion

The viability of fast-ignition (FI) inertial confinement fusion hinges on the efficient transfer of laser energy to the compressed fuel via multi-MeV electrons. Preformed plasma due to the laser prepulse strongly influences ultraintense laser plasma interactions and hot electron generation in the hollow cone of an FI target. We induced a prepulse and consequent preplasma in copper cone targets and measured the energy deposition zone of the main pulse by imaging the emitted K{sub {alpha}} radiation. Simulation of the radiation hydrodynamics of the preplasma and particle in cell modeling of the main pulse interaction agree well with the measured deposition zones and provide an insight into the energy deposition mechanism and electron distribution. It was demonstrated that a under these conditions a 100 mJ prepulse eliminates the forward going component of {approx}2-4 MeV electrons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Operator Lévy Flight: Light Cones in Chaotic Long-Range Interacting Systems

We argue that chaotic power-law interacting systems have emergent limits on information propagation, analogous to relativistic light cones, which depend on the spatial dimension d and the exponent α governing the decay of interactions. Using the dephasing nature of quantum chaos, we map the problem to a stochastic model with a known phase diagram. A linear light cone results for α ≥ $\textit{d}$ + 1/2. We also provide a Lévy flight (long-range random walk) interpretation of the results and show consistent numerical data for 1D long-range spin models with 200 sites.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Calibration of megavoltage cone-beam CT for radiotherapy dose calculations: Correction of cupping artifacts and conversion of CT numbers to electron density

Megavoltage cone-beam CT (MV CBCT) is used for three-dimensional imaging of the patient anatomy on the treatment table prior to or just after radiotherapy treatment. To use MV CBCT images for radiotherapy dose calculation purposes, reliable electron density (ED) distributions are needed. Patient scatter, beam hardening and softening effects result in cupping artifacts in MV CBCT images and distort the CT number to ED conversion. A method based on transmission images is presented to correct for these effects without using prior knowledge of the object's geometry. The scatter distribution originating from the patient is calculated with pencil beam scatter kernels that are fitted based on transmission measurements. The radiological thickness is extracted from the scatter subtracted transmission images and is then converted to the primary transmission used in the cone-beam reconstruction. These corrections are performed in an iterative manner, without using prior knowledge regarding the geometry and composition of the object. The method was tested using various homogeneous and inhomogeneous phantoms with varying shapes and compositions, including a phantom with different electron density inserts, phantoms with large density variations, and an anthropomorphic head phantom. For all phantoms, the cupping artifact was substantially removed from the images and a linear relation between the CT number and electron density was found. After correction the deviations in reconstructed ED from the true values were reduced from up to 0.30 ED units to 0.03 for the majority of the phantoms; the residual difference is equal to the amount of noise in the images. The ED distributions were evaluated in terms of absolute dose calculation accuracy for homogeneous cylinders of different size; errors decreased from 7% to below 1% in the center of the objects for the uncorrected and corrected images, respectively, and maximum differences were reduced from 17% to 2%, respectively. The presented method corrects the MV CBCT images for cupping artifacts and extracts reliable ED information of objects with varying geometries and composition, making these corrected MV CBCT images suitable for accurate dose calculation purposes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of radiation dose delivered by cone beam CT and tomosynthesis employed for setup of external breast irradiation

A systematic set of measurements is reported for evaluation of doses to critical organs resulting from cone-beam CT (CB-CT) and cone-beam tomosynthesis (CB-TS) as applied to breast setup for external beam irradiation. The specific focus of this study was on evaluation of doses from these modalities in a setting of volumetric breast imaging for target localization in radiotherapy treatments with the goal of minimizing radiation to healthy organs. Ion chamber measurements were performed in an anthropomorphic female thorax phantom at the center of each breast and lung and on the phantom surface at one anterior and two lateral locations (seven points total). The measurements were performed for three different isocenters located at the center of the phantom and at offset locations of the right and left breast. The dependence of the dose on angle selection for the CB-TS arc was also studied. For the most typical situation of centrally located CB-CT isocenter the measured doses ranged between 3 and 7 cGy, in good agreement with previous reports. Dose measurements were performed for a range of start/stop angles commonly used for CB-TS and the impact of direct and scatter dose on organs at risk was analyzed. All measured CB-TS doses were considerably lower than CB-CT doses, with greater decrease in dose for the organs outside of the beam (up to 98% decrease in dose). Remarkably, offsetting the isocenter towards the ipsilateral breast resulted on average to additional 46% dose reduction to organs at risk. The lowest doses to the contralateral breast and lung were less than 0.1 cGy when they were measured for the offset isocenter. The biggest reduction in dose was obtained by using CB-TS beams that completely avoid the critical organ. For points inside the CB-TS beam, the dose was reduced in a linear relation with distance from the center of the imaging arc. The data indicate that it is possible to reduce substantially radiation doses to the contralateral organs by proper selection of CB-TS angles and imaging field sizes. Our results provide the first systematic study on CB-TS doses from setup imaging for external breast irradiation and can be a useful resource for estimating anticipated radiation doses as a function of the conditions chosen for imaging breast setup.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dual resolution cone beam breast CT: A feasibility study

Purpose: In this study, the authors investigated the feasibility of a dual resolution volume-of-interest (VOI) cone beam breast CT technique and compared two implementation approaches in terms of dose saving and scatter reduction. Methods: With this technique, a lead VOI mask with an opening is inserted between the x-ray source and the breast to deliver x-ray exposure to the VOI while blocking x rays outside the VOI. A CCD detector is used to collect the high resolution projection data of the VOI. Low resolution cone beam CT (CBCT) images of the entire breast, acquired with a flat panel (FP) detector, were used to calculate the projection data outside the VOI with the ray-tracing reprojection method. The Feldkamp-Davis-Kress filtered backprojection algorithm was used to reconstruct the dual resolution 3D images. Breast phantoms with 180 {mu}m and smaller microcalcifications (MCs) were imaged with both FP and FP-CCD dual resolution CBCT systems, respectively. Two approaches of implementing the dual resolution technique, breast-centered approach and VOI-centered approach, were investigated and evaluated for dose saving and scatter reduction with Monte Carlo simulation using a GEANT4 package. Results: The results showed that the breast-centered approach saved more breast absorbed dose than did VOI-centered approach with similar scatter reduction. The MCs in fatty breast phantom, which were invisible with FP CBCT scan, became visible with the FP-CCD dual resolution CBCT scan. Conclusions: These results indicate potential improvement of the image quality inside the VOI with reduced breast dose both inside and outside the VOI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adaptive two-pass cone-beam artifact correction using a FOV-preserving two-source geometry: A simulation study

The evolution to ever wider detector arrays that are able to cover whole organs with a single circular gantry sweep has revitalized the research efforts toward finding improved axial scanning algorithms and protocols. The authors propose a computed tomography scan and reconstruction concept using two sources, a single detector and a two-pass cone-beam correction method, as an integral part of the reconstruction. Compared with standard circular acquisition and reconstruction methods, the new concept excels with improved coverage and very low cone-beam artifact level also for short scan acquisitions, which makes it especially attractive for cardiac applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of arc-modulated cone beam therapy and helical tomotherapy for three different types of cancer

Purpose: Arc-modulated cone beam therapy (AMCBT) is a fast treatment technique deliverable in a single rotation with a conventional C-arm shaped linac. In this planning study, the authors assess the dosimetric properties of single-arc therapy in comparison to helical tomotherapy for three different tumor types. Methods: Treatment plans for three patients with prostate carcinoma, three patients with anal cancer, and three patients with head and neck cancer were optimized for helical tomotherapy and AMCBT. The dosimetric comparison of the two techniques is based on physical quantities derived from dose-volume histograms. Results: For prostate cancer, the quality of dose distributions calculated for AMCBT was of equal quality as that generated for tomotherapy with the additional benefits of a faster delivery and a lower integral dose. For highly complex geometries, the plan quality achievable with helical tomotherapy could not be achieved with arc-modulated cone beam therapy. Conclusions: Rotation therapy with a conventional linac in a single arc is capable to deliver a high and homogeneous dose to the target and spare organs at risk. Advantages of this technique are a fast treatment time and a lower integral dose in comparison to helical tomotherapy. For highly complex cases, e.g., with several target regions, the dose shaping capabilities of AMCBT are inferior to those of tomotherapy. However, treatment plans for AMCBT were also clinically acceptable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Estimation of organ doses from kilovoltage cone-beam CT imaging used during radiotherapy patient position verification

Purpose: The purpose of this study was to develop a practical method for estimating organ doses from kilovoltage cone-beam CT (CBCT) that can be performed with readily available phantoms and dosimeters. The accuracy of organ dose estimates made using the ImPACT patient dose calculator was also evaluated. Methods: A 100 mm pencil chamber and standard CT dose index (CTDI) phantoms were used to measure the cone-beam dose index (CBDI). A weighted CBDI (CBDI{sup w}) was then calculated from these measurements to represent the average volumetric dose in the CTDI phantom. By comparing CBDI{sup w} to the previously published organ doses, organ dose conversion coefficients were developed. The measured CBDI values were also used as inputs for the ImPACT calculator to estimate organ doses. All CBDI dose measurements were performed on both the Elekta XVI and Varian OBI at three clinically relevant locations: Head, chest, and pelvis. Results: The head, chest, and pelvis protocols yielded CBDI{sup w} values of 0.98, 16.62, and 24.13 mGy for the XVI system and 5.17, 6.14, and 21.57 mGy for the OBI system, respectively. Organ doses estimated with the ImPACT CT dose calculator showed a large range of variation from the previously measured organ doses, demonstrating its limitations for use with CBCT. Conclusions: The organ dose conversion coefficients developed in this work relate CBDI{sup w} values to organ doses previously measured using the same clinical protocols. Ultimately, these coefficients will allow for the quick estimation of organ doses from routine measurements performed using standard CTDI phantoms and pencil chambers.

60 APPLIED LIFE SCIENCES↗

Radiation doses in cone-beam breast computed tomography: A Monte Carlo simulation study

Purpose: In this article, we describe a method to estimate the spatial dose variation, average dose and mean glandular dose (MGD) for a real breast using Monte Carlo simulation based on cone beam breast computed tomography (CBBCT) images. We present and discuss the dose estimation results for 19 mastectomy breast specimens, 4 homogeneous breast models, 6 ellipsoidal phantoms, and 6 cylindrical phantoms. Methods: To validate the Monte Carlo method for dose estimation in CBBCT, we compared the Monte Carlo dose estimates with the thermoluminescent dosimeter measurements at various radial positions in two polycarbonate cylinders (11- and 15-cm in diameter). Cone-beam computed tomography (CBCT) images of 19 mastectomy breast specimens, obtained with a bench-top experimental scanner, were segmented and used to construct 19 structured breast models. Monte Carlo simulation of CBBCT with these models was performed and used to estimate the point doses, average doses, and mean glandular doses for unit open air exposure at the iso-center. Mass based glandularity values were computed and used to investigate their effects on the average doses as well as the mean glandular doses. Average doses for 4 homogeneous breast models were estimated and compared to those of the corresponding structured breast models to investigate the effect of tissue structures. Average doses for ellipsoidal and cylindrical digital phantoms of identical diameter and height were also estimated for various glandularity values and compared with those for the structured breast models. Results: The absorbed dose maps for structured breast models show that doses in the glandular tissue were higher than those in the nearby adipose tissue. Estimated average doses for the homogeneous breast models were almost identical to those for the structured breast models (p=1). Normalized average doses estimated for the ellipsoidal phantoms were similar to those for the structured breast models (root mean square (rms) percentage difference=1.7%; p=0.01), whereas those for the cylindrical phantoms were significantly lower (rms percentage difference=7.7%; p<0.01). Normalized MGDs were found to decrease with increasing glandularity. Conclusions: Our results indicate that it is sufficient to use homogeneous breast models derived from CBCT generated structured breast models to estimate the average dose. This investigation also shows that ellipsoidal digital phantoms of similar dimensions (diameter and height) and glandularity to actual breasts may be used to represent a real breast to estimate the average breast dose with Monte Carlo simulation. We have also successfully demonstrated the use of structured breast models to estimate the true MGDs and shown that the normalized MGDs decreased with the glandularity as previously reported by other researchers for CBBCT or mammography.

60 APPLIED LIFE SCIENCES↗

A general framework and review of scatter correction methods in x-ray cone-beam computerized tomography. Part 1: Scatter compensation approaches

Since scattered radiation in cone-beam volume CT implies severe degradation of CT images by quantification errors, artifacts, and noise increase, scatter suppression is one of the main issues related to image quality in CBCT imaging. The aim of this review is to structurize the variety of scatter suppression methods, to analyze the common structure, and to develop a general framework for scatter correction procedures. In general, scatter suppression combines hardware techniques of scatter rejection and software methods of scatter correction. The authors emphasize that scatter correction procedures consist of the main components scatter estimation (by measurement or mathematical modeling) and scatter compensation (deterministic or statistical methods). The framework comprises most scatter correction approaches and its validity also goes beyond transmission CT. Before the advent of cone-beam CT, a lot of papers on scatter correction approaches in x-ray radiography, mammography, emission tomography, and in Megavolt CT had been published. The opportunity to avail from research in those other fields of medical imaging has not yet been sufficiently exploited. Therefore additional references are included when ever it seems pertinent. Scatter estimation and scatter compensation are typically intertwined in iterative procedures. It makes sense to recognize iterative approaches in the light of the concept of self-consistency. The importance of incorporating scatter compensation approaches into a statistical framework for noise minimization has to be underscored. Signal and noise propagation analysis is presented. A main result is the preservation of differential-signal-to-noise-ratio (dSNR) in CT projection data by ideal scatter correction. The objective of scatter compensation methods is the restoration of quantitative accuracy and a balance between low-contrast restoration and noise reduction. In a synopsis section, the different deterministic and statistical methods are discussed with respect to their properties and applications. The current paper is focused on scatter compensation algorithms. The multitude of scatter estimation models will be dealt with in a separate paper.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Task-based modeling and optimization of a cone-beam CT scanner for musculoskeletal imaging

Purpose: This work applies a cascaded systems model for cone-beam CT imaging performance to the design and optimization of a system for musculoskeletal extremity imaging. The model provides a quantitative guide to the selection of system geometry, source and detector components, acquisition techniques, and reconstruction parameters. Methods: The model is based on cascaded systems analysis of the 3D noise-power spectrum (NPS) and noise-equivalent quanta (NEQ) combined with factors of system geometry (magnification, focal spot size, and scatter-to-primary ratio) and anatomical background clutter. The model was extended to task-based analysis of detectability index (d') for tasks ranging in contrast and frequency content, and d' was computed as a function of system magnification, detector pixel size, focal spot size, kVp, dose, electronic noise, voxel size, and reconstruction filter to examine trade-offs and optima among such factors in multivariate analysis. The model was tested quantitatively versus the measured NPS and qualitatively in cadaver images as a function of kVp, dose, pixel size, and reconstruction filter under conditions corresponding to the proposed scanner. Results: The analysis quantified trade-offs among factors of spatial resolution, noise, and dose. System magnification (M) was a critical design parameter with strong effect on spatial resolution, dose, and x-ray scatter, and a fairly robust optimum was identified at M {approx} 1.3 for the imaging tasks considered. The results suggested kVp selection in the range of {approx}65-90 kVp, the lower end (65 kVp) maximizing subject contrast and the upper end maximizing NEQ (90 kVp). The analysis quantified fairly intuitive results--e.g., {approx}0.1-0.2 mm pixel size (and a sharp reconstruction filter) optimal for high-frequency tasks (bone detail) compared to {approx}0.4 mm pixel size (and a smooth reconstruction filter) for low-frequency (soft-tissue) tasks. This result suggests a specific protocol for 1 x 1 (full-resolution) projection data acquisition followed by full-resolution reconstruction with a sharp filter for high-frequency tasks along with 2 x 2 binning reconstruction with a smooth filter for low-frequency tasks. The analysis guided selection of specific source and detector components implemented on the proposed scanner. The analysis also quantified the potential benefits and points of diminishing return in focal spot size, reduced electronic noise, finer detector pixels, and low-dose limits of detectability. Theoretical results agreed quantitatively with the measured NPS and qualitatively with evaluation of cadaver images by a musculoskeletal radiologist. Conclusions: A fairly comprehensive model for 3D imaging performance in cone-beam CT combines factors of quantum noise, system geometry, anatomical background, and imaging task. The analysis provided a valuable, quantitative guide to design, optimization, and technique selection for a musculoskeletal extremities imaging system under development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗