Recent Progress with APC Nb 3 Sn Conductors [Slides]
1.Development of APC-PIT multi wires started in 2017. Since then progress has been fast; 2.Tests up to 31 T at 4.2 K show that B irr is 26-27 T, B c2 is 27-28 T, ~1-2 T higher than RRP; 3. R&D in the past two years has led to significant improvement of wire recipe and quality. The non-Cu J c is on similar level with present RRP wires, in spite that the Nb 3 Sn % is still low and grain size is not fully refined due to unoptimized wire recipe and heat treatment; 4.The Nb 3 Sn layer J c at 16 T is ~2.5 times of RRP despite grain size not fully refined; 5.The improvement is still ongoing. The following levels are expected: 1) By improving conductor recipe and quality and heat treatment, the fine-grain Nb 3 Sn fraction can be increased to ~40%, as in standard tube type and PIT wires; 2) By optimizing O content and heat treatment, the grain size can be reduced to 50-65 nm or less, which leads to a Nb 3 Sn layer J c of 5000-6000 A/mm 2 for 4.2 K, 16 T. If so, this means the 4.2 K, 16 T non-Cu Jc can reach 2000-2400 A/mm 2 . This will surpass the FCC spec and also provide >30% margin. Above 16 T, the APC conductors should give extra Jc gain due to higher B irr and shift in F p -B curve peak to higher fields.