Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMPARTMENTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Compositional breast imaging using a dual-energy mammography protocol

Purpose: Mammography has a low sensitivity in dense breasts due to low contrast between malignant and normal tissue confounded by the predominant water density of the breast. Water is found in both adipose and fibroglandular tissue and constitutes most of the mass of a breast. However, significant protein mass is mainly found in the fibroglandular tissue where most cancers originate. If the protein compartment in a mammogram could be imaged without the influence of water, the sensitivity and specificity of the mammogram may be improved. This article describes a novel approach to dual-energy mammography, full-field digital compositional mammography (FFDCM), which can independently image the three compositional components of breast tissue: water, lipid, and protein. Methods: Dual-energy attenuation and breast shape measures are used together to solve for the three compositional thicknesses. Dual-energy measurements were performed on breast-mimicking phantoms using a full-field digital mammography unit. The phantoms were made of materials shown to have similar x-ray attenuation properties of the compositional compartments. They were made of two main stacks of thicknesses around 2 and 4 cm. Twenty-six thickness and composition combinations were used to derive the compositional calibration using a least-squares fitting approach. Results: Very high accuracy was achieved with a simple cubic fitting function with root mean square errors of 0.023, 0.011, and 0.012 cm for the water, lipid, and protein thicknesses, respectively. The repeatability (percent coefficient of variation) of these measures was tested using sequential images and was found to be 0.5%, 0.5%, and 3.3% for water, lipid, and protein, respectively. However, swapping the location of the two stacks of the phantom on the imaging plate introduced further errors showing the need for more complete system uniformity corrections. Finally, a preliminary breast image is presented of each of the compositional compartments separately. Conclusions: FFDCM has been derived and exhibited good compositional thickness accuracy on phantoms. Preliminary breast images demonstrated the feasibility of creating individual compositional diagnostic images in a clinical environment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Physics strategies for sparing neural stem cells during whole-brain radiation treatments

Purpose: Currently, there are no successful long-term treatments or preventive strategies for radiation-induced cognitive impairments, and only a few possibilities have been suggested. One such approach involves reducing the dose to neural stem cell compartments (within and outside of the hippocampus) during whole-brain radiation treatments for brain metastases. This study investigates the fundamental physics issues associated with the sparing of neural stem cells during photon radiotherapy for brain metastases. Methods: Several factors influence the stem cell dose: intracranial scattering, collimator leakage, beam energy, and total number of beams. The relative importance of these factors is investigated through a set of radiation therapy plans, which are all variations of an initial 6 MV intensity-modulated radiation therapy (IMRT) plan designed to simultaneously deliver a whole-brain dose of 30 Gy and maximally reduce stem cell compartment dose. Additionally, an in-house leaf segmentation algorithm was developed that utilizes jaw motion to minimize the collimator leakage. Results: The plans are all normalized such that 50% of the PTV receives 30 Gy. For the initial 6 MV IMRT plan, 50% of the stem cells receive a dose greater than 6.3 Gy. Calculations indicate that 3.6 Gy of this dose originates from intracranial scattering. The jaw-tracking segmentation algorithm, used in conjunction with direct machine parameter optimization, reduces the 50% stem cell dose to 4.3 and 3.7 Gy for 6 and 10 MV treatment beams, respectively. Conclusions: Intracranial scattering alone is responsible for a large dose contribution to the stem cell compartment. It is, therefore, important to minimize other contributing factors, particularly the collimator leakage, to maximally reduce dose to these critical structures. The use of collimator jaw tracking in conjunction with modern collimators can minimize this leakage.

61 RADIATION PROTECTION AND DOSIMETRY↗

Impact of extraneous mispositioned events on motion-corrected brain SPECT images of freely moving animals

Purpose: Single photon emission computed tomography (SPECT) brain imaging of freely moving small animals would allow a wide range of important neurological processes and behaviors to be studied, which are normally inhibited by anesthetic drugs or precluded due to the animal being restrained. While rigid body motion of the head can be tracked and accounted for in the reconstruction, activity in the torso may confound brain measurements, especially since motion of the torso is more complex (i.e., nonrigid) and not well correlated with that of the head. The authors investigated the impact of mispositioned events and attenuation due to the torso on the accuracy of motion corrected brain images of freely moving mice. Methods: Monte Carlo simulations of a realistic voxelized mouse phantom and a dual compartment phantom were performed. Each phantom comprised a target and an extraneous compartment which were able to move independently of each other. Motion correction was performed based on the known motion of the target compartment only. Two SPECT camera geometries were investigated: a rotating single head detector and a stationary full ring detector. The effects of motion, detector geometry, and energy of the emitted photons (hence, attenuation) on bias and noise in reconstructed brain regions were evaluated. Results: The authors observed two main sources of bias: (a) motion-related inconsistencies in the projection data and (b) the mismatch between attenuation and emission. Both effects are caused by the assumption that the orientation of the torso is difficult to track and model, and therefore cannot be conveniently corrected for. The motion induced bias in some regions was up to 12% when no attenuation effects were considered, while it reached 40% when also combined with attenuation related inconsistencies. The detector geometry (i.e., rotating vs full ring) has a big impact on the accuracy of the reconstructed images, with the full ring detector being more advantageous. Conclusions: Motion-induced inconsistencies in the projection data and attenuation/emission mismatch are the two main causes of bias in reconstructed brain images when there is complex motion. It appears that these two factors have a synergistic effect on the qualitative and quantitative accuracy of the reconstructed images.

60 APPLIED LIFE SCIENCES↗

SU-E-T-70: A Radiobiological Model of Reoxygenation and Fractionation Effects

Purpose: To develop a simple reoxygenation model that fulfills the following goals:1-Quantify the reoxygenation effect in biologically effective dose (BED) and compare it to the repopulation effect.2-Model the hypoxic fraction in tumors as a function of the number of fractions.3-Develop a simple analytical expression for a reoxygenation term in BED calculations. Methods: The model considers tumor cells in two compartments: one normoxic population of cells and one hypoxic compartment including cells under a range of reduced oxygen concentrations. The surviving fraction is predicted using the linear-quadratic (LQ) model. A hypoxia reduction factor (HRF) is used to quantify reductions in radiosensitivity parameters α-A and β-A as cellular oxygen concentration decreases. The HRF is defined as the ratio of the dose at a specific level of hypoxia to the dose under fully aerobic conditions to achieve equal cell killing. The model assumes that a fraction of the hypoxic cells ( ) moves from the hypoxic to the aerobic compartment after each daily fraction. As an example, we consider standard fractionation for NSCLC (d=2Gy,n=33) versus a SBRT (n=5, d=10Gy) fractionation and compare the loss in reoxygenation biological effect with the gain in repopulation biological effect. Results: An analytic expression for the surviving fraction after n daily treatments is derived and the reoxygenation term in the biological effect is calculated. Reoxygenation and repopulation effects are the same order of magnitude for potential doubling time Td values of 2 to 5 days. The hypoxic fraction increases or decreases with n depending on the reoxygenation rate Δ. For certain combinations of parameters, the biological effect of reoxygenation goes as -(n-1)*ln(1-Δ) providing a simple expression that can be introduced in BED calculations. Conclusion: A novel radiobiological model was developed that can be used to evaluate the effect of reoxygenation in fractionated radiotherapy.

60 APPLIED LIFE SCIENCES↗

TestDose: A nuclear medicine software based on Monte Carlo modeling for generating gamma camera acquisitions and dosimetry

Purpose: The TestDose platform was developed to generate scintigraphic imaging protocols and associated dosimetry by Monte Carlo modeling. TestDose is part of a broader project (www.dositest.com) whose aim is to identify the biases induced by different clinical dosimetry protocols. Methods: The TestDose software allows handling the whole pipeline from virtual patient generation to resulting planar and SPECT images and dosimetry calculations. The originality of their approach relies on the implementation of functional segmentation for the anthropomorphic model representing a virtual patient. Two anthropomorphic models are currently available: 4D XCAT and ICRP 110. A pharmacokinetic model describes the biodistribution of a given radiopharmaceutical in each defined compartment at various time-points. The Monte Carlo simulation toolkit GATE offers the possibility to accurately simulate scintigraphic images and absorbed doses in volumes of interest. The TestDose platform relies on GATE to reproduce precisely any imaging protocol and to provide reference dosimetry. For image generation, TestDose stores user’s imaging requirements and generates automatically command files used as input for GATE. Each compartment is simulated only once and the resulting output is weighted using pharmacokinetic data. Resulting compartment projections are aggregated to obtain the final image. For dosimetry computation, emission data are stored in the platform database and relevant GATE input files are generated for the virtual patient model and associated pharmacokinetics. Results: Two samples of software runs are given to demonstrate the potential of TestDose. A clinical imaging protocol for the Octreoscan™ therapeutical treatment was implemented using the 4D XCAT model. Whole-body “step and shoot” acquisitions at different times postinjection and one SPECT acquisition were generated within reasonable computation times. Based on the same Octreoscan™ kinetics, a dosimetry computation performed on the ICRP 110 model is also presented. Conclusions: The proposed platform offers a generic framework to implement any scintigraphic imaging protocols and voxel/organ-based dosimetry computation. Thanks to the modular nature of TestDose, other imaging modalities could be supported in the future such as positron emission tomography.

60 APPLIED LIFE SCIENCES↗

Quantitatively accurate activity measurements with a dedicated cardiac SPECT camera: Physical phantom experiments

Purpose: Recently, there has been increased interest in dedicated cardiac single photon emission computed tomography (SPECT) scanners with pinhole collimation and improved detector technology due to their improved count sensitivity and resolution over traditional parallel-hole cameras. With traditional cameras, energy-based approaches are often used in the clinic for scatter compensation because they are fast and easily implemented. Some of the cardiac cameras use cadmium-zinc-telluride (CZT) detectors which can complicate the use of energy-based scatter correction (SC) due to the low-energy tail—an increased number of unscattered photons detected with reduced energy. Modified energy-based scatter correction methods can be implemented, but their level of accuracy is unclear. In this study, the authors validated by physical phantom experiments the quantitative accuracy and reproducibility of easily implemented correction techniques applied to {sup 99m}Tc myocardial imaging with a CZT-detector-based gamma camera with multiple heads, each with a single-pinhole collimator. Methods: Activity in the cardiac compartment of an Anthropomorphic Torso phantom (Data Spectrum Corporation) was measured through 15 {sup 99m}Tc-SPECT acquisitions. The ratio of activity concentrations in organ compartments resembled a clinical {sup 99m}Tc-sestamibi scan and was kept consistent across all experiments (1.2:1 heart to liver and 1.5:1 heart to lung). Two background activity levels were considered: no activity (cold) and an activity concentration 1/10th of the heart (hot). A plastic “lesion” was placed inside of the septal wall of the myocardial insert to simulate the presence of a region without tracer uptake and contrast in this lesion was calculated for all images. The true net activity in each compartment was measured with a dose calibrator (CRC-25R, Capintec, Inc.). A 10 min SPECT image was acquired using a dedicated cardiac camera with CZT detectors (Discovery NM530c, GE Healthcare), followed by a CT scan for attenuation correction (AC). For each experiment, separate images were created including reconstruction with no corrections (NC), with AC, with attenuation and dual-energy window (DEW) scatter correction (ACSC), with attenuation and partial volume correction (PVC) applied (ACPVC), and with attenuation, scatter, and PVC applied (ACSCPVC). The DEW SC method used was modified to account for the presence of the low-energy tail. Results: T-tests showed that the mean error in absolute activity measurement was reduced significantly for AC and ACSC compared to NC for both (hot and cold) datasets (p < 0.001) and that ACSC, ACPVC, and ACSCPVC show significant reductions in mean differences compared to AC (p ≤ 0.001) without increasing the uncertainty (p > 0.4). The effect of SC and PVC was significant in reducing errors over AC in both datasets (p < 0.001 and p < 0.01, respectively), resulting in a mean error of 5% ± 4%. Conclusions: Quantitative measurements of cardiac {sup 99m}Tc activity are achievable using attenuation and scatter corrections, with the authors’ dedicated cardiac SPECT camera. Partial volume corrections offer improvements in measurement accuracy in AC images and ACSC images with elevated background activity; however, these improvements are not significant in ACSC images with low background activity.

61 RADIATION PROTECTION AND DOSIMETRY↗

Reconstruction and modeling protein translocation and compartmentalization in Escherichia coli at the genome-scale

Background: Membranes play a crucial role in cellular functions. Membranes provide a physical barrier, control the trafficking of substances entering and leaving the cell, and are a major determinant of cellular ultra-structure. In addition, components embedded within the membrane participate in cell signaling, energy transduction, and other critical cellular functions. All these processes must share the limited space in the membrane; thus it represents a notable constraint on cellular functions. Membrane- and location-based processes have not yet been reconstructed and explicitly integrated into genome-scale models. Results: The recent genome-scale model of metabolism and protein expression in Escherichia coli (called a ME-model) computes the complete composition of the proteome required to perform whole cell functions. Here we expand the ME-model to include (1) a reconstruction of protein translocation pathways, (2) assignment of all cellular proteins to one of four compartments (cytoplasm, inner membrane, periplasm, and outer membrane) and a translocation pathway, (3) experimentally determined translocase catalytic and porin diffusion rates, and (4) a novel membrane constraint that reflects cell morphology. Comparison of computations performed with this expanded ME-model, named iJL1678-ME, against available experimental data reveals that the model accurately describes translocation pathway expression and the functional proteome by compartmentalized mass. Conclusion: iJL1678-ME enables the computation of cellular phenotypes through an integrated computation of proteome composition, abundance, and activity in four cellular compartments (cytoplasm, periplasm, inner and outer membrane). Reconstruction and validation of the model has demonstrated that the iJL1678-ME is capable of capturing the functional content of membranes, cellular compartment-specific composition, and that it can be utilized to examine the effect of perturbing an expanded set of network components. iJL1678-ME takes a notable step towards the inclusion of cellular ultra-structure in genome-scale models.

59 BASIC BIOLOGICAL SCIENCES↗

Sodium Pool Fire Phenomena, Sodium Pool Fire Modeling in SOFIRE II, and SOFIRE II Calculations for the AFR-100

The SOFIRE II computer code for the calculation of sodium pool fires has been obtained from the Reactor Safety Information Computational Center and the SOFIRE II ONE CELL version has been implemented at Argonne National Laboratory (ANL). A critical review of literature relevant to sodium pool fires has been carried out with the objectives of understanding sodium pool fire phenomena and how well specific phenomena are modeled or neglected in SOFIRE II. Significant predictions about sodium pool fires can be made on the basis of first principles analyses alone making use of the existing experiment database and knowledge base. In implementing SOFIRE II ONE CELL, minor modifications were necessary to compile and execute the code on a personal computer (PC) and to verify the results of the test case problem. The code was applied to the AFR-100 Sodium-Cooled Fast Reactor (SFR) design to calculate a sodium pool fire following a postulated failure of the sodium storage vessel of one of the four intermediate sodium heat transport circuits and the subsequent release of sodium onto the floor of the steel-lined compartment in which the sodium storage vessel is located. SOFIRE II calculates that only a small fraction of the released sodium burns due to the rapid consumption of the available oxygen inside of the closed compartment. The preliminary results demonstrate the effects of the heat sinks provided by the compartment floor, walls, and ceiling in reducing the temperature of the sodium pool with time.

Sienicki, James J.↗

Annual Status Report (FY 2018): Performance Assessment for the Disposal of Low-Level Waste in the 200 East Area Burial Grounds (Rev. 0)

This annual review provides the projected dose estimates of radionuclide inventories disposed in the active 200 East Area Low-Level Waste Burial Grounds (LLBGs) since September 26, 1988. These estimates are calculated using the original dose methodology developed in the performance assessment (PA) analysis. The estimates are compared with performance objectives defined in U.S. Department of Energy (DOE) requirements (DOE O 435.1 Chg 1 and companion documents DOE M 435.1-1 Chg 1 and DOE G 435.1-1). All performance objectives are currently satisfied, and operational waste acceptance criteria and waste acceptance practices continue to be sufficient to maintain compliance with performance objectives. Inventory estimates and associated dose estimates from future waste disposal actions are unchanged from previous years' evaluations that indicate potential impacts well below performance objectives; therefore, future compliance with DOE O 435.1 Chg 1 is expected. Within the active burial grounds, low-level waste and mixed low-level waste currently may be disposed only in the dedicated U.S. Navy reactor compartment trench in the 218-E-12B Burial Ground (Trench 94). Naval reactor compartment disposal at Trench 94 will continue. During this reporting period (fiscal year 2018, from October 1, 2017, through September 30, 2018), two reactor compartments were disposed in Trench 94. Results from multi-year diffusion experiments are summarized for this reporting period to quantify the efficacy of concrete waste forms in retaining key radionuclides (e.g., uranium-238, technetium-99, and iodine-129). The results of sorption experiments initiated in FY 2017 to evaluate sorption coefficients for iodine and technetium are also summarized. The test durations ranged from 1 to 6 months. Continued groundwater monitoring of the 200 East Area LLBGs indicates no groundwater contamination due to LLBG waste. Current assumptions about future land use at the Hanford Site are consistent with PA analysis assumptions of a post-closure facility that will not be degraded by human activity. The LLBGs are located in an area identified for waste management and containment of residual contamination. This area will remain after final environmental remediation and the proposed shrinkage of Hanford Site boundaries to small sections within the 200 East Area and 200 West Area in the Central Plateau. Overall, there are no substantive changes to primary PA assumptions and no changes to the PA analysis conclusion; therefore, compliance with DOE O 435.1 Chg 1 is being maintained.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Cacti Microbiome: Interplay between Habitat-Filtering and Host-Specificity

Cactaceae represents one of the most species-rich families of succulent plants native to arid and semi-arid ecosystems, yet the associations Cacti establish with microorganisms and the rules governing microbial community assembly remain poorly understood. We analyzed the composition, diversity, and factors influencing above- and below-ground bacterial, archaeal, and fungal communities associated with two native and sympatric Cacti species: Myrtillocactus geometrizans and Opuntia robusta. Phylogenetic profiling showed that the composition and assembly of microbial communities associated with Cacti were primarily influenced by the plant compartment; plant species, site, and season played only a minor role. Remarkably, bacterial, and archaeal diversity was higher in the phyllosphere than in the rhizosphere of Cacti, while the opposite was true for fungi. Semi-arid soils exhibited the highest levels of microbial diversity whereas the stem endosphere the lowest. Despite their taxonomic distance, M. geometrizans and O. robusta shared most microbial taxa in all analyzed compartments. Influence of the plant host did only play a larger role in the fungal communities of the stem endosphere. These results suggest that fungi establish specific interactions with their host plant inside the stem, whereas microbial communities in the other plant compartments may play similar functional roles in these two species. Biochemical and molecular characterization of seed-borne bacteria of Cacti supports the idea that these microbial symbionts may be vertically inherited and could promote plant growth and drought tolerance for the fitness of the Cacti holobiont. We envision this knowledge will help improve and sustain agriculture in arid and semi-arid regions of the world.

59 BASIC BIOLOGICAL SCIENCES↗

Ecosystem carbon transit versus turnover times in response to climate warming and rising atmospheric CO 2 concentration

Ecosystem carbon (C) transit time is a critical diagnostic parameter to characterize land C sequestration. This parameter has different variants in the literature, including a commonly used turnover time. However, we know little about how different transit time and turnover time are in representing carbon cycling through multiple compartments under a non-steady state. In this study, we estimate both C turnover time as defined by the conventional stock over flux and mean C transit time as defined by the mean age of C mass leaving the system. We incorporate them into the Community Atmosphere Biosphere Land Exchange (CABLE) model to estimate C turnover time and transit time in response to climate warming and rising atmospheric [CO 2 ]. Modelling analysis shows that both C turnover time and transit time increase with climate warming but decrease with rising atmospheric [CO 2 ]. Warming increases C turnover time by 2.4 years and transit time by 11.8 years in 2100 relative to that at steady state in 1901. During the same period, rising atmospheric [CO 2 ] decreases C turnover time by 3.8 years and transit time by 5.5 years. Our analysis shows that 65&thinsp;% of the increase in global mean C transit time with climate warming results from the depletion of fast-turnover C pool. The remaining 35&thinsp;% increase results from accompanied changes in compartment C age structures. Similarly, the decrease in mean C transit time with rising atmospheric [CO 2 ] results approximately equally from replenishment of C into fast-turnover C pool and subsequent decrease in compartment C age structure. Greatly different from the transit time, the turnover time, which does not account for changes in either C age structure or composition of respired C, underestimated impacts of warming and rising atmospheric [CO 2 ] on C diagnostic time and potentially led to deviations in estimating land C sequestration in multi-compartmental ecosystems.

54 ENVIRONMENTAL SCIENCES↗

Orifice In-flow Efficiency Tests. Volume 1: Test Results. Volume 2: Application to Shuttle Venting During Entry

An investigation was made of the capability for computing internal pressures throughout flight for compartments located within space shuttle vehicles. A test program was conducted at a 6 x 6 foot supersonic wind tunnel to determine orifice efficiencies for the flow of air into a compartment from a flowing external stream. Measurements were made over a Mach number range of 0.7 to 1.9 for varying orifice geometry, vent orientation, vent plate thickness, flat plate boundary layer thickness, and pressure ratio across the vent plate. A computer program developed for outflow venting was modified for use in computing compartment pressures for inflow conditions. Results from both the outflow and inflow computer programs are included. A user's manual and program listing of the inflow venting program are also included.

Haukohl, J.↗

Docking structure for spacecraft

A docking structure for a pair of spacecraft is described comprising a conical receptacle on the docking end of a first spacecraft that receives a mating conical projection on the docking end of the second spacecraft. The conical receptacle of the first spacecraft constitutes an exterior portion of a sealed gas-tight compartment. Pressurization of the sealed compartment causes the conical receptacle to extend toward the incoming conical projection of the second spacecraft. When the mating conical portions are latched together, the docking energy is absorbed by the compressed gas in the sealed compartment. Rebound forces are countered by a plurality of actuator cylinders supporting the conical receptacle.

Belew, R. R.↗

Gamma time-dependency in Blaxter's compartmental model.

A new two-compartment model for the passage of particles through the gastro-intestinal tract of ruminants is proposed. In this model, a gamma distribution of lifetimes is introduced in the first compartment; thereby, passage from that compartment becomes time-dependent. This modification is strongly suggested by the physical alteration which certain substances, e.g. hay particles, undergo in the digestive process. The proposed model is applied to experimental data.

Matis, J. H.↗

Shuttle Kit Freezer Refrigeration Unit Conceptual Design

The refrigerated food/medical sample storage compartment as a kit to the space shuttle orbiter is examined. To maintain the -10 F in the freezer kit, an active refrigeration unit is required, and an air cooled Stirling Cycle refrigerator was selected. The freezer kit contains two subsystems, the refrigeration unit, and the storage volume. The freezer must provide two basic capabilities in one unit. One requirement is to store 215 lbs of food which is consumed in a 30-day period by 7 people. The other requirement is to store 128.3 lbs of medical samples consisting of both urine and feces. The unit can be mounted on the lower deck of the shuttle cabin, and will occupy four standard payload module compartments on the forward bulkhead. The freezer contains four storage compartments.

Copeland, R. J.↗

Passive propellant system

A passive propellant acquisition and feed system is disclosed which acquires and feeds gas-free propellant in low or zero-g environments during orbital maneuvers and retains this propellant under high axially directed acceleration such as may be experienced during launch of a space vehicle and orbit-to-orbit transfer is described. The propellant system includes a dual compartment propellant tank with independent surface tension acquisition channels in each compartment to provide gas-free flow of pressurized liquid propellant from one compartment to the other in one direction only.

Hess, D. A.↗

Release mechanism for releasing and reattaching experiments on the Space Shuttle

The release mechanism (REM) unlatches an experiment so that it can be moved about inside and outside the shuttle bay by the remote manipulator system (RMS), and then reattaches it to the REM base. Operated from the crew compartment after the RMS has been attached to the experiment, the REM releases the experiment by an electric motor driving a gear train and linkage which extracts four pins from holes in four plates. Electrical connectors on the REM are disengaged by the mechanical action of the structural pins retracting from the plates. When the REM releases the experiment, an unlatched indicator is actuated in the crew compartment, and then the experiment can be moved by using the RMS. To reattach the experiment to the REM, the RMS places the experiment with REM attachment angles against the flat, smooth surface of the REM; then the RMS moves the experiment into position for latchup. Actuation of an electric motor drives the four pins into the four holes in the plates. When fully latched, a switch actuated by the motion of the linkage, shuts the electric motor off and gives an indication to the crew compartment that the REM is latched.

Clark, A. V.↗

An investigation of drag reduction for a standard truck with various modifications

A wind tunnel investigation was conducted to determine the influence of several physical variables on the aerodynamic drag of a standard truck model. The physical variables included: a cab mounted air deflector; a boattail on the rear of the cargo compartment; flow-vanes on the front of the cargo compartment; and a forebody fairing over the cab. Tests were conducted at yaw angles (relative wind angle) of 0, 5, 10, 20, and 30 degrees and Reynolds numbers of 3.4 x 100,000 to 6.1 x 100,000 based upon the equivalent diameter of the vehicles. The forebody fairing and the flow-vane with the closed bottom were very effective in improving the flow over the forward part of the cargo compartment. The forebody fairing provided a calculated fuel saving of 5.6 liters per hour (1.5 gallons per hour) over the baseline configuration for a ground speed of 88.6 km/hr (55 mph) in national average winds.

Muirhead, V. U.↗