Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CFD simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Performance evaluation of radiant cooling system integrated with air system under different operational strategies

The paper describes a parametric study developed to estimate the energy savings potential of a radiant cooling system installed in a commercial building in India. The study is based on numerical modeling of a radiant cooling system installed in an Information Technology (IT) office building sited in the composite climate of Hyderabad. To evaluate thermal performance and energy consumption, simulations were carried out using the ANSYS FLUENT and EnergyPlus softwares, respectively. The building model was calibrated using the measured data for the installed radiant system. Then this calibrated model was used to simulate the energy consumption of a building using a conventional all-air system to determine the proportional energy savings. For proper handling of the latent load, a dedicated outside air system (DOAS) was used as an alternative to Fan Coil Unit (FCU). A comparison of energy consumption calculated that the radiant system was 17.5 % more efficient than a conventional all-air system and that a 30% savings was achieved by using a DOAS system compared with a conventional system. Computational Fluid Dynamics (CFD) simulation was performed to evaluate indoor air quality and thermal comfort. It was found that a radiant system offers more uniform temperatures, as well as a better mean air temperature range, than a conventional system. To further enhance the energy savings in the radiant system, different operational strategies were analyzed based on thermal analysis using EnergyPlus. Lastly, the energy savings achieved in this parametric run were more than 10% compared with a conventional all-air system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Alternative Frictional Boundary Condition for Computational Fluid Dynamics Simulation of Friction Stir Welding

For better application of numerical simulation in optimization and design of friction stir welding (FSW), this paper presents a new frictional boundary condition at the tool/workpiece interface for computational fluid dynamics (CFD) modeling of FSW. The proposed boundary condition is based on an implementation of the Coulomb friction model. Using the new boundary condition, the CFD simulation yields non-uniform distribution of contact state over the tool/workpiece interface, as validated by the experimental weld macrostructure. It is found that interfacial sticking state is present over large area at the tool-workpiece interface, while significant interfacial sliding occurs at the shoulder periphery, the lower part of pin side, and the periphery of pin bottom. Due to the interfacial sticking, a rotating flow zone is found under the shoulder, in which fast circular motion occurs. The diameter of the rotating flow zone is smaller than the shoulder diameter, which is attributed to the presence of the interfacial sliding at the shoulder periphery. For the simulated welding condition, the heat generation due to friction and plastic deformation makes up 54.4 and 45.6% of the total heat generation rate, respectively. In conclusion, the simulated temperature field is validated by the good agreement to the experimental measurements.

36 MATERIALS SCIENCE↗

Enhancement of Unsteady and 3D Aerodynamics Models using Machine Learning

Unsteady aerodynamics will be an important part of the floating wind turbines of the future operating under high shear across the rotor disk coupled with platform motion and atmospheric turbulence. We develop an unsteady aerodynamics and dynamic stall model using a long short-term memory variant of recurrent neural networks. The neural network model is trained using the oscillating airfoil data set from Ohio State University. The predictions from our machine learning (ML)-based model show good agreement with the experimental data and other state-of-the-art dynamic stall models for a wide range of airfoils, Reynolds numbers and reduced frequencies. In some cases the predictions are better than the Beddoes-Leishman model implementation in OpenFAST, when using the default coefficients. The ML-based model is also able to capture the key physics associated with dynamic stall, such as the precedence of moment stall before lift stall and cycle-to-cycle variations in the aerodynamic response. The new unsteady aerodynamics model is expected to improve prediction of fatigue loads for yaw-based wake-steering control scenarios in actuator-line and actuator-disc simulations of wind farms. Our methodology for training the ML-model provides a pathway for improving design level tools using high-fidelity computational fluid dynamics (CFD) simulations in the future.

17 WIND ENERGY↗

CFD Evaluation of Pressure Change Along Coolant Passages in Sodium-Cooled Fast Reactor with Nek5000

To support the design efforts of advanced sodium-cooled fast reactors (SFRs), a series of computational fluid dynamics (CFD) simulations are performed to investigate the pressure change along various flow passages in the proposed SFR system. The simulations are carried out with the state-of-the-art spectral element flow solver, Nek5000. Two specific case studies are presented in this paper: the flow exiting the axial neutron reflector channels and the flow entering the fuel pin bundle. Due to the high Reynolds numbers expected, a Reynolds-averaged Navier-Stokes (RANS) approach is necessary to model the turbulence. A newly developed regularized k-omega RANS model is adopted in the related CFD calculations. The first case study explores the effect of Reynolds number on the pressure change when flow exits the reflector channels. The pressure change in this case has two major contributors: the change due to wall friction and the Bernoulli effect. It is noted that the nondimensional pressure loss follows a log-linear trend up to Re = 10 5 , and then the trend is flattened. In the second case study, the advanced NekNek coupling capability is tested where an integral domain can be divided into multiple subdomains with coupling interfaces, which would greatly ease the meshing process of complex engineering geometries and potentially save computational resources. The preliminary results obtained so far confirm the consistency between the NekNek results and those produced by regular Nek5000 simulation. The presented work demonstrates the readiness and flexibility of the related CFD techniques, which is part of the broader effort to leverage cutting-edge CFD to inform the advanced nuclear reactor designs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal-hydraulic performance of printed circuit heat exchangers: CFD analysis with experimental validation - 18434

Results of a computational fluid dynamic (CFD) study of flow and heat transfer in a printed circuit heat exchanger (PCHE) geometry are presented. CFD results obtained from a two-plate model are compared to corresponding experimental results for the validation. This process provides the basis for further application of the CFD code to PCHE design and performance analysis in a variety of internal flow geometries. As a part of the code verification and validation (V and V) process, CFD simulation of a single semicircular straight channel under laminar isothermal conditions was also performed and compared to theoretical results. This comparison yielded good agreement with the theoretical values. The two-plate CFD model based on the experimental PCHE design overestimated the effectiveness and underestimated the pressure drop. However, it is found that the discrepancy between the CFD result and experimental data was a result of the uncertainty in the geometry of heat exchanger during the fabrication. The CFD results obtained using a slightly smaller channel diameter yielded good agreement with the experimental data. A separate investigation revealed that the average channel diameter of the OSU PCHE after the diffusion-bonding was 1.93 mm on the cold fluid side and 1.90 mm on the hot fluid side which are both smaller than the nominal design value. Consequently, the CFD code was shown to have sufficient capability to evaluate the heat exchanger thermal-hydraulic performance. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

REBOUND: Reverse Engineering Bidirectional Outflow Under Non-Equilibrium Diffusion

Rare-earth elements (REEs) are essential for electronics, renewable energy, and defense technologies. However, the current supply of REEs relies on mining concentrated in a few countries and energy-intensive separations. DOE’s Basic Energy Sciences (BES) program has launched a grand challenge which aims to ensure a sustainable supply of critical REEs by developing innovative and environmentally friendly separation methods. As an alternative to costly and harmful traditional methods, the Non-Equilibrium Transport Driven Separations (NETS) initiative has created a microfluidic Y-channel co-flow method that applies external fields to exploit magneto- and electrohydrodynamic effects for separating dilute REE ions from complex feedstocks. Computational fluid dynamics (CFD) studies have identified a few operating conditions with promising ion selectivity and separation efficiency. However, challenges remain regarding Y-channel versatility across feedstocks and accurate incorporation of physical phenomena into CFD models. In this work, we develop a multi-fidelity modelling approach which integrates experimental results with CFD simulation to build a surrogate model for the dependence of separation efficiency to variation of design parameters. The surrogate model enables a reinforcement learning (RL) method to adaptively launch CFD and experimental runs, improving model fidelity around optimal Y-channel parameters.

36 MATERIALS SCIENCE↗

Effects of Different Types of Entrances on Natural Ventilation in a Subway Station

In this study, the natural ventilation of a horizontal entrance of a typical subway station is investigated based on numerical simulations and experiments. In addition, a renormalization group k-e model (RNG k-e model) is applied to compute both the internal and external airflow patterns. Computational fluid dynamics (CFD) simulations are validated based on the experimental results. Furthermore, a multiple variable regression model is employed to study how the different parameters affect the internal airflow rates of the subway station statistically, according to the experimental results. For this typical model, the parameter importance can be ranked as follows: (1) outdoor wind speed; (2) flow resistance of the subway station; (3) height of the wind catcher; and (4) length of the wind catcher. To understand the detailed pressure distribution of the horizontal entrance of the subway station with and without the wind catcher, 3D numerical simulations are conducted for different scenarios. We attempt to alter the size of the wind catcher (including the length and height) to study the characteristics of the pressure on the horizontal entrance of the subway station under outdoor wind-driven conditions. The pressure distributions for the entrance for different scenarios are compared and analyzed. Finally, the interactions between the internal and external flows are investigated by changing the resistance of the subway station. When the internal flow resistance is changed, the pressure coefficient (Cp) of the entrance is different as well. Hence, the Cp is not only affected by the outdoor environment, but is also influenced by the internal airflows.

CFD↗

A New 1D Model for Thermal Mixing and Stratification in Advanced Reactor Transients

Thermal mixing and stratification in large pools and enclosures play a critical role in the safety and performance of pool-type nuclear reactors, particularly during transient scenarios involving significant temperature differences between incoming and bulk coolant. Accurate modeling of these phenomena is essential for predicting system behavior and supporting passive safety features such as natural circulation. Here, this paper presents a new 1D model for thermal mixing and stratification, developed and implemented in the SAM code. The model represents a large pool as 1D coolant jet channels and zero-dimensional bulk pool volumes, enabling the simulation of a wide range of flow configurations, including hot and cold jet interactions, stratified layers, and the influence of complex geometries such as ceilings, free surfaces, and internal obstacles. Heat exchange between jet and pool regions is governed by closure relations calibrated against 3D computational fluid dynamics (CFD) simulations. The model improves upon earlier approaches by incorporating time-dependent jet characteristics and capturing the associated delay effects more accurately. Code-to-code comparisons and validation against experimental data from the Thermal Stratification Test Facility demonstrate the model’s accuracy and flexibility. This work offers two key contributions: (1) an efficient and robust method for simulating thermal mixing and stratification at the system level, eliminating the need for external coupling between system analysis codes and CFD, and (2) a significant enhancement of SAM’s capabilities to analyze thermal stratification phenomena in advanced reactor systems.

SAM↗

Measurement of a radial flow profile with eddy current flow meters and deep neural networks

Eddy current flow meters (ECFMs) measure flows of conductive fluids. Recent interest in ECFMs has increased due to applications in advanced nuclear reactors. ECFMs are well suited for such applications, as they can provide non-invasive measurements of flow in fluids that are often difficult to measure. Traditionally, ECFMs are operated using an alternating current at a single frequency, limiting ECFMs to measure average fluid velocities, blockages, or voids. Here, we expand the capabilities of ECFMs by measuring the fluid radial velocity profile of liquid mercury. To accomplish this, we made several ECFM sensitivity measurements at a range of frequencies. Different frequencies vary the electromagnetic skin depth of the device. By adjusting frequencies, we probed the fluid velocity at various radial locations and constructed a flow-velocity profile. The relationship between the ECFM measurements and velocity profile is nonlinear and requires solving an inverse problem. Using electromagnetic finite-element simulations to train a deep neural network (DNN), we created a model that provides a stable general relationship between the sensitivity measurements of an ECFM and the fluid velocity profile. Using ECFM measurements of liquid mercury, our DNN model calculates a flow profile that agrees well with computational fluid dynamics (CFD) simulations. This technique has potential to improve flow monitoring for optimization, safe operation of conductive fluid loops, and/or validating complex CFD models.

47 OTHER INSTRUMENTATION↗

Computer simulation as a NOx reduction design tool

Nalco Mobotec engineers were charged with reducing emissions on a utility boiler converted from burning oil to eastern bituminous coal using the company's Rotamix selective noncatalytic reduction (SNCR) system which injects urea into the furnace. A CFD simulation of the existing boiler was first conducted and then the furnace was simulated with the SNCR system added and the design was optimised. Operating and capital costs were minimised by optimal placement of 50 injector ports. 6 figs., 2 tabs.

01 COAL, LIGNITE, AND PEAT↗

Computing the ankle-brachial index with parallel computational fluid dynamics

The ankle-brachial index (ABI), a ratio of arterial blood pressure in the ankles and upper arms, is used to diagnose and monitor circulatory conditions such as coarctation of the aorta and peripheral artery disease. Computational simulations of the ABI can potentially determine the parameters that produce an ABI indicative of ischemia or other abnormalities in blood flow. However, 0- and 1-D computational methods are limited in describing a 3-D patient-derived geometry. Thus, we present a massively parallel framework for computational fluid dynamics (CFD) simulations in the full arterial system. Additionally, using the lattice Boltzmann method to solve the Navier–Stokes equations, we employ highly parallelized and scalable methods to generate the simulation domain and efficiently distribute the computational load among processors. For the first time, we compute an ABI with 3-D CFD. In this proof-of-concept study, we investigate the dependence of ABI on the presence of stenoses, or narrowed regions of the arteries, by directly modifying the arterial geometry. As a result, our framework enables the computation a hemodynamic factor characterizing flow at the scale of the full arterial system, in a manner that is extensible to patient-specific imaging data and holds potential for treatment planning.

59 BASIC BIOLOGICAL SCIENCES↗

Development of Switchable Polarity Solvent Draw Solutes

Results of a computational fluid dynamic (CFD) study of flow and heat transfer in a printed circuit heat exchanger (PCHE) geometry are presented. CFD results obtained from a two-plate model are compared to corresponding experimental results for the validation. This process provides the basis for further application of the CFD code to PCHE design and performance analysis in a variety of internal flow geometries. As a part of the code verification and validation (V&V) process, CFD simulation of a single semicircular straight channel under laminar isothermal conditions was also performed and compared to theoretical results. This comparison yielded excellent agreement with the theoretical values. The two-plate CFD model based on the experimental PCHE design overestimated the effectiveness and underestimated the pressure drop. However, it is found that the discrepancy between the CFD result and experimental data was mainly caused by the uncertainty in the geometry of heat exchanger during the fabrication. The CFD results obtained using a slightly smaller channel diameter yielded good agreement with the experimental data. A separate investigation revealed that the average channel diameter of the OSU PCHE after the diffusion-bonding was 1.93 mm on the cold fluid side and 1.90 mm on the hot fluid side which are both smaller than the nominal design value. Consequently, the CFD code was shown to have sufficient capability to evaluate the heat exchanger thermal-hydraulic performance.

42 ENGINEERING↗

The MAX facility for CFD code validation

ANL has recently completed construction of a fluid dynamics test facility devised to provide validation data for CFD simulation tools used to evaluate various aspects of nuclear power plant design and safety. Experiments with the facility involve mixing air jets within a 1x1x1.7m long glass tank at atmospheric pressure. A particle image velocimetry system measures flow velocity and turbulence quantities within the tank while a high-speed infrared camera records temperatures across the tank lid. The tandem of high fidelity thermal and turbulence data is particularly useful for benchmarking transient heat transfer phenomena such as thermal striping. This paper describes the MAX facility, preliminary data obtained during shakedown tests, and the results of companion CFD calculations employing RANS-based Star-CCM+ and large eddy simulations with Nek 5000. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Recovering missing CFD data for high-order discretizations using deep neural networks and dynamics learning

Data I/O poses a significant bottleneck in large-scale CFD simulations; thus, practitioners would like to significantly reduce the number of times the solution is saved to disk, yet retain the ability to recover any field quantity (at any time instance) a posteriori . The objective of this work is therefore to accurately recover missing CFD data a posteriori at any time instance, given that the solution has been written to disk at only a relatively small number of time instances. We consider in particular high-order discretizations (e.g., discontinuous Galerkin), as such techniques are becoming increasingly popular for the simulation of highly separated flows. To satisfy this objective, this work proposes a methodology consisting of two stages: 1) dimensionality reduction and 2) dynamics learning. For dimensionality reduction, we propose a novel hierarchical approach. First, the method reduces the number of degrees of freedom within each element of the high-order discretization by applying autoencoders from deep learning. Second, the methodology applies principal component analysis to compress the global vector of encodings. This leads to a low-dimensional state, which associates with a nonlinear embedding of the original CFD data. For dynamics learning, we propose to apply regression techniques (e.g., kernel methods) to learn the discrete-time velocity characterizing the time evolution of this low-dimensional state. In conclusion, a numerical example on a large-scale CFD example characterized by nearly 13 million degrees of freedom illustrates the suitability of the proposed method in an industrial setting.

97 MATHEMATICS AND COMPUTING↗

Micro-environmental control for efficient local cooling

Micro-environment is hereby defined as the air space and environment around a person that directly impacts his/her thermal sensation. Most existing HVAC systems condition the air of the entire room including the unoccupied space, which leaves a big potential to save energy. This study aims at evaluating the performance of three existing air terminal devices (ATDs) to locally remove enough heat from the micro-environment to manage the thermal balance so as not to sacrifice thermal comfort when the ambient unoccupied space temperature is increased by 2.2 °C from 23.9 °C to 26.1 °C in the summer to reduce the external cooling load. A computational fluid dynamics (CFD) model was developed, validated by full-scale chamber tests and applied to evaluate different configurations of the ATDs for local cooling. Results show that the predicted performance agreed well with the measurements, and the selected ATD, with only 50 W cooling power, was always able to remove a sufficient amount of heat from the microenvironment in a room of raised temperature, when the manikin was moved inside a semicircle movement range. The cooling performance of the jet was increased more by increasing the supply air flow rate than reducing the supply temperature and was highly dependent on the shooting angle. Finally, the heat flux from the manikin surface is very sensitive to the surface temperature and furniture placement, and proper specification of the surface temperature is crucial for the CFD simulation to match the measured results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Spray–Wall Interactions in a Small-Bore, Multicylinder Engine Operating With Reactivity-Controlled Compression Ignition

Experimental work on reactivity-controlled compression ignition (RCCI) in a small-bore, multicylinder engine operating on premixed iso-octane, and direct-injected n-heptane has shown an unexpected combustion phasing advance at early injection timings, which has not been observed in large-bore engines operating under RCCI at similar conditions. In this study, computational fluid dynamics (CFD) simulations were performed to investigate whether spray–wall interactions could be responsible for this result. Comparison of the spray penetration, fuel film mass, and in-cylinder visualization of the spray from the CFD results to the experimentally measured combustion phasing and emissions provided compelling evidence of strong fuel impingement at injection timings earlier than -90 crank angle degrees (deg CA) after top dead center (aTDC), and transition from partial to full impingement between -65 and -90 deg CA aTDC. Finally, based on this evidence, explanations for the combustion phasing advance at early injection timings are proposed along with potential verification experiments.

42 ENGINEERING↗

Effect of excess air on the optimization of heating appliances for biomass combustion

The performance of a domestic appliance for wood logs combustion is a function of several variables, such as the geometric design of the appliance and its operating parameters. Among them, air feeding conditions are really decisive if the objective function is the maximization of the heat recovered from flue gases. Therefore, even if pollutant emissions have to be ever considered, the amount of excess air can be seen as a fundamental parameter in the definition of thermal efficiency of the appliance. In this paper the role of this parameter is analysed. The analysis is conducted by linking the results obtained from experimental data, detailed CFD simulations and a simplified mathematical model based on a network of CSTR. The derivation of an idealized schematization of the appliance was essential to realize the role of excess air variations, with more generality than with respect to a specific appliance configuration. Conversely, while the experimental data and CFD results were necessary to derive the simplified model, the indications given by this simplified model were useful to analyze results coming from both experiments and detailed numerical simulations. It has been evidenced the need to distinguish between the role of excess air in the chemical combustion and in the heat recovery in the appliance as well as to quantify the feedback between these two processes. (author)

09 BIOMASS FUELS↗

BWR Full Fuel Assembly Testing and Validation

This report describes the Consortium for Advanced Simulation of Light Water Reactors (CASL) work conducted for completion of the Thermal Hydraulics Methods (THM) Level 3 milestone THM.CLS.P15.10: BWR Full Fuel Assembly Testing and Validation. The extension of existing boiling closure designed for Pressurized Water Reactors (PWRs) to the high void fraction condition of Boiling Water Reactors (BWRs) is one of the challenges for Multiphase Computational Fluid Dynamics (M-CFD) applications. In the efforts aimed at developing the advanced boiling closure for BWRs, the baseline closure model, so-called ‘Zero’ closure, has been developed based on the GEN-I closure for PWRs which was used as a starting point. Since this simplest closure model is robust but does not contain any explicit description of the complex high void fraction mechanisms, the applicability of M-CFD needs to be evaluated before developing advanced closures for BWRs. To support this need, the high fidelity M-CFD simulation with Zero closure has been conducted for the BWR full fuel assembly. The capabilities of M-CFD with Zero closure were evaluated against the international OECD/NRC BFBT benchmark data. The scalability of the M-CFD application to the nuclear fuel assembly was demonstrated with the INL High Performance Computing (HPC) system. This report presents the recent view of the best practices on M-CFD for BWRs to provide a useful reference to identify and overcome common challenges in the M-CFD applications.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗