Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CESIUM ION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Crystalline Silicotitanate (CST) Ion Exchange Media Performance Evaluations to Support TSCR DSA IX Media Equilibrium Contacts

The primary objective of this work is to calculate the maximum loading expected on the Hanford Tank Side Cesium Removal (TSCR) ion exchange columns. A key consideration in the design of the columns is the amount of 137 Cs that loads onto the Crystalline Silicotitanate (CST) and the heat generated by the loaded column during storage. Per request of Washington River Protection Solutions (WRPS), Savannah River National Laboratory (SRNL) has utilized ZAM, a computer program developed by the research group of Professor Rayford G. Anthony of Texas A&M University, to predict the cesium loading on the CST for a variety of waste compositions expected to be processed by TSCR. The study evaluated cesium loadings for the following waste compositions: 1. Seventeen DFLAW campaign batches to cover projected supernate composition ranges within which TSCR may be expected to operate within the first ten years, 2. Hanford tank AP-105 and AP-107 waste solutions that will be processed by the TSCR system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Two halide-containing cesium manganese vanadates: synthesis, characterization, and magnetic properties

In this study, two new halide-containing cesium manganese vanadates have been synthesized by a high-temperature (580 °C) hydrothermal synthetic method from aqueous brine solutions. One compound, Cs 3 Mn(VO 3 ) 4 Cl, (1) was prepared using a mixed cesium hydroxide/chloride mineralizer, and crystallizes in the polar noncentrosymmetric space group Cmm2, with a = 16.7820(8) Å, b = 8.4765(4) Å, c = 5.7867(3) Å. This structure is built from sinusoidal zig-zag (VO 3 ) n chains that run along the b-axis and are coordinated to Mn 2+ containing (MnO 4 Cl) square-pyramidal units that are linked together to form layers. The cesium cations reside between the layers, but also coordinate to the chloride ion, forming a cesium chloride chain that also propagates along the b-axis. The other compound, Cs 2 Mn(VO 3 ) 3 F, (2) crystallizes in space group Pbca with a = 7.4286(2) Å, b = 15.0175(5) Å, c = 19.6957(7) Å, and was prepared using a cesium fluoride mineralizer. The structure is comprised of corner sharing octahedral Mn 2+ chains, with trans fluoride ligands acting as bridging units, whose ends are capped by (VO 3 ) n vanadate chains to form slabs. The cesium atoms reside between the manganese vanadate layers, and also play an integral part in the structure, forming a cesium fluoride chain that runs along the b-axis. Both compounds were characterized by single-crystal X-ray diffraction, powder X-ray diffraction, and single-crystal Raman spectroscopy. Additionally, the magnetic properties of 2 were investigated. Lastly, above 50 K, it displays behavior typical of a low dimensional system with antiferromagnetic interactions, as to be expected for linear chains of manganese(II) within the crystal structure.

36 MATERIALS SCIENCE↗

EVALUATION OF POTENTIAL ELUANTS FOR NON-ACID ELUTION OF CESIUM FROM SPHERICAL RESORCINOL-FORMALDEHYDE RESIN

Ion Exchange column loading and elution of cesium from spherical resorcinol-formaldehyde resin have been conducted for two potential non-acid eluants -(NH{sub 4}){sub 2}CO{sub 3} and CH{sub 3}COONH{sub 4}. The results revealed encouraging cesium elution performance. 100% elution was achieved in at most 22 hours ({approx}28 bed volumes) of elution. Elution performance was fairly high at 6 hours ({approx}8 bed volumes) of elution for some of the eluants and also practically comparable to the benchmark acid eluant (HNO{sub 3}). Hence, it is quite possible 100% percent elution will be closer to the 6th hour than the 22nd hour. Elution is generally enhanced by increasing the concentration and pH of the eluants, and combining the eluants.

36 MATERIALS SCIENCE↗

SELECTIVE REMOVAL OF STRONTIUM AND CESIUM FROM SIMULATED WASTE SOLUTION WITH TITANATE ION-EXCHANGERS IN A FILTER CARTRIDGE CONFIGURATIONS-12092

Experimental results for the selective removal of strontium and cesium from simulated waste solutions with monosodium titanate (MST) and crystalline silicotitanate (CST) laden filter cartridges are presented. In these proof-of-principle tests, effective uptake of both Sr-85 and Cs-137 were observed using ion-exchangers in this filter cartridge configuration. At low salt simulant conditions, the instantaneous decontamination factor (D{sub F}) for Sr-85 with MST impregnated filter membrane cartridges measured 26, representing 96% Sr-85 removal efficiency. On the other hand, the Sr-85 instantaneous D{sub F} with co-sintered active MST cartridges measured 40 or 98% Sr-85 removal efficiency. Strontium-85 removal with the MST impregnated membrane cartridges and CST impregnated membrane cartridges, placed in series arrangement, produced an instantaneous decontamination factor of 41 compared to an instantaneous decontamination factor of 368 for strontium-85 with co-sintered active MST cartridges and co-sintered active CST cartridges placed in series. Overall, polyethylene co-sintered active titanates cartridges performed as well as titanate impregnated filter membrane cartridges in the uptake of strontium. At low ionic strength conditions, there was a significant uptake of Cs-137 with co-sintered CST cartridges. Tests results with CST impregnated membrane cartridges for Cs-137 decontamination are currently being re-evaluated. Based on these preliminary findings we conclude that incorporating MST and CST sorbents into membranes represent a promising method for the semi-continuous removal of radioisotopes of strontium and cesium from nuclear waste solutions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Gas Generation Testing of Crystalline Silicotitanate Ion Exchange Media

The Direct Feed Low-Activity Waste (DFLAW) process has been proposed to support early production of immobilized low-activity waste (LAW) at the Hanford site. As planned, Hanford tank waste would be sent to the Tank Side Cesium Removal (TSCR) system for solids removal (by filtration) and cesium removal (by ion exchange) during the initial phase of the DFLAW process. The resultant treated waste would be delivered to the LAW Vitrification Facility at the Hanford Tank Waste Treatment and Immobilization Plant (WTP) for immobilization. The ongoing technology maturation of TSCR system components is being conducted by Washington River Protection Solutions, LLC (WRPS). The ion exchange process in the TSCR system will use columns of crystalline silicotitanate (CST) to remove cesium from the LAW. This report describes gas generation testing of the crystalline silicotitanate ion exchange media that was conducted to strengthen the technical basis of the media for use in the TSCR system. Specifically, the described study will inform the safety basis of both the operation of the TSCR system and the interim storage condition of the TSCR ion exchange columns after loading. Previous data on gas generation of CST are limited to a handful of studies using CST or similar media under unrepresentative conditions and durations. The safety basis underlying operation and storage of the CST columns needs to consider the rate and extent of radiolytic flammable gas generation. No existing studies provide a comprehensive set of gas generation data for column operating and storage conditions representative of those expected for TSCR. To address the data gap, this study was conducted under the following conditions (each in duplicate): (1) CST in water at 25°C tested to 300 Mrad total dose, (2) wet CST (soaked in water, then free-drained) at 25°C tested to both 300 Mrad and 900 Mrad total dose, (3) dry CST (air-dried, free-flowing material equilibrated to laboratory conditions) at 25°C tested to both 300 Mrad and 900 Mrad total dose, (4) CST in 5.6M Na simulant at 25°C tested to 300 Mrad total dose, and (5) CST in 5.6M Na simulant with 1% (w/w) total organic carbon as Na 3 -HEDTA at 25°C and 70°C tested to 300 Mrad total dose. For each of the listed conditions, the generation of the following gas species was measured: hydrogen, oxygen, nitrous oxide, and methane. The test data was used to determine the amount of gas generated (total and on a per-component basis), gas generation rates normalized to the CST bed volume tested, and G-values for each gas species. The reported results illustrate that the CST-in-water condition bounds the gas generation rate (at 25°C) of all other conditions, but there is some variability in the hydrogen G-value, depending on the lot of CST tested and the amount of residual moisture present at the start of the test.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Gas Generation Testing of Crystalline Silicotitanate Ion Exchange Media

The Direct Feed Low-Activity Waste (DFLAW) process has been proposed to support early production of immobilized low-activity waste (LAW) at the Hanford site. As planned, Hanford tank waste would be sent to the Tank Side Cesium Removal (TSCR) system for solids removal (by filtration) and cesium removal (by ion exchange) during the initial phase of the DFLAW process. The resultant treated waste would be delivered to the LAW Vitrification Facility at the Hanford Tank Waste Treatment and Immobilization Plant (WTP) for immobilization. The ongoing technology maturation of TSCR system components is being conducted by Washington River Protection Solutions, LLC (WRPS). The ion exchange process in the TSCR system will use columns of crystalline silicotitanate (CST) to remove cesium from the LAW. This report describes gas generation testing of the crystalline silicotitanate ion exchange media that was conducted to strengthen the technical basis of the media for use in the TSCR system. Specifically, the described study will inform the safety basis of both the operation of the TSCR system and the interim storage condition of the TSCR ion exchange columns after loading. Previous data on gas generation of CST are limited to a handful of studies using CST or similar media under unrepresentative conditions and durations. The safety basis underlying operation and storage of the CST columns needs to consider the rate and extent of radiolytic flammable gas generation. No existing studies provide a comprehensive set of gas generation data for column operating and storage conditions representative of those expected for TSCR. To address the data gap, this study was conducted under the following conditions (each in duplicate): (1) CST in water at 25°C tested to 300 Mrad total dose, (2) wet CST (soaked in water, then free-drained) at 25°C tested to both 300 Mrad and 900 Mrad total dose, (3) dry CST (air-dried, free-flowing material equilibrated to laboratory conditions) at 25°C tested to both 300 Mrad and 900 Mrad total dose, (4) CST in 5.6M Na simulant at 25°C tested to 300 Mrad total dose, and (5) CST in 5.6M Na simulant with 1%(w/w) total organic carbon as Na3-HEDTA at 25°C and 70°C tested to 300 Mrad total dose. For each of the listed conditions, the generation of the following gas species was measured: hydrogen, oxygen, nitrous oxide, and methane. The test data was used to determine the amount of gas generated (total and on a per component basis), gas generation rates normalized to the CST bed volume tested, and G-values for each gas species. The reported results illustrate that the CST in water condition bounds the gas generation rate (at 25°C) of all other conditions, but there is some variability in the hydrogen G-value, depending on the lot of CST tested and the amount of residual moisture present at the start of the test.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Efficient cesiation in RF driven surface plasma negative ion source

Experiments on hydrogen negative ions production in the large radio-frequency negative ion source with cesium seed are described. The system of directed cesium deposition to the plasma grid periphery was used. The small cesium seed (∼0.5 G) provides an enhanced H{sup −} production during a 2 month long experimental cycle. The gradual increase of negative ion yield during the long-term source runs was observed after cesium addition to the source. The degraded H{sup −} production was recorded after air filling to the source or after the cesium washing away from the driver and plasma chamber walls. The following source conditioning by beam shots produces the gradual recovery of H{sup −} yield to the high value. The effect of H{sup −} yield recovery after cesium coverage passivation by air fill was studied. The concept of cesium coverage replenishment and of H{sup −} yield recovery due to sputtering of cesium from the deteriorated layers is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Emittance improvement efforts on the 15-20 mA dc H{sup -} multicusp source

A 15 mA beam from the 15-20 mA dc H{sup -} multicusp source has been obtained at China Institute of Atomic Energy. In order to improve the emittance of extracted beam from this new multicusp source, some measures have been taken, i.e., increasing the length of the ion source body, improving the vacuum in the extraction area, injecting cesium vapor into the ion source, etc. The hardware, including the lengthened source body, the improved back cover and cesium heating system, and the extraction vacuum box, will be described. Initial results for these efforts aimed at emittance improvement will also be given in the paper.

43 PARTICLE ACCELERATORS↗

Exploring cesium properties internal to the LANSCE H - ion source using resonant absorption spectroscopy

The Los Alamos Neutron Science Center (LANSCE) H - ion source has provided stable output for decades of LANL mission needs, but its maximum beam output has remained the same at ~15 mA. A roadblock to improving beam output has been a lack of thorough understanding of the internal mechanisms of LANSCE H - ion source. The LANSCE H - Ion Source Laser Diagnostic Stand (HLDS) was recently built and commissioned to explore these internal mechanisms using laser absorption techniques, to measure and diagnose dynamic H - and cesium densities. The cesium density probe is based on resonant absorption of a continuous wave diode laser tuned though the D 2 line of cesium (~852 nm). The diagnostic capabilities of HLDS will be reviewed, and measurements using the cesium laser diagnostic will be presented.

43 PARTICLE ACCELERATORS↗

Effect of ion excape velocity and conversion surface material on H- production

According to generally accepted models surface production of negative ions depends on ion escape velocity and work function of the surface. We have conducted an experimental study addressing the role of the ion escape velocity on H{sup -} production. A converter-type ion source at Los Alamos Neutron Science Center was employed for the experiment. The ion escape velocity was changed by varying the bias voltage of the converter electrode. It was observed that due to enhanced stripping of H{sup -} no direct gain of extracted beam current can be achieved by increasing the converter voltage. At the same time the conversion efficiency of H{sup -} was observed to vary with converter voltage and follow the existing theories in qualitative manner. We discuss the role of surface material on H{sup -} formation probability and present calculations predicting relative H{sup -} yields from different cesiated surfaces. These calculations are compared with experimental observations from different types of H{sup -} ion sources. The effects caused by varying cesium coverage are also discussed. Finally, we present a novel idea of utilizing materials exhibiting so-called negative electron affinity in H{sup -}/D{sup -} production under UV-light exposure.

43 PARTICLE ACCELERATORS↗

Correction factors for saturation effects in white light and laser absorption spectroscopy for application to low pressure plasmas

In white light absorption spectroscopy, the broadening of the absorption signal due to the apparatus profile of the spectrometer may lead to an underestimation of the determined density as one measures an apparent optical depth. This is in particular true for high optical depth where saturation effects of the transmitted intensity occur. Provided that the line profile of the absorption line is known, the apparent optical depth effect can be accounted for by introducing a correction factor. The impact of the saturation and the approach of considering the effect are demonstrated for argon and indium lines in low pressure plasmas where correction factors of one order of magnitude or even higher are reached very easily. For the indium line, the hyperfine splitting has been taken into account. In laser absorption, the line profile is resolved. However, the weak but rather broad background emission of the laser diode can cause a saturation signal at the photo diode resulting also in an underestimation of the density obtained from the analysis. It is shown that this can be taken into account by fitting the theoretical line profile to the measured absorption signal which yields also a correction factor. The method is introduced and demonstrated at the example of the cesium resonance line including the hyperfine splitting. Typical correction factors around two are obtained for the cesium ground state density at conditions of a low pressure negative hydrogen ion source in which cesium is evaporated to enhance the negative ion production.

74 ATOMIC AND MOLECULAR PHYSICS↗

Tank Side Cesium Removal for Hanford Tank Waste - Actual Waste Demonstrations - 20467

The US DOE and its contractors are evaluating several options for treating Hanford tank supernate streams to provide feed for the Low-Activity Waste Facility at the Hanford Waste Treatment and Immobilization Plant. At this time, the intent is to deploy a Tank-Side Cesium Removal system. The key unit operations for this process are filtration and cesium removal by ion exchange. To assess the anticipated performance of the system, tests with actual waste were performed with samples from Hanford tanks AW-102 and AP-107 to provide basis data regarding the performance of the system in treating these materials. The decanted supernate waste samples from tanks AW-102 and AP-107 were received directly by the Radiochemical Processing Laboratory at Pacific Northwest National Laboratory. These samples were then filtered to provide data on dead-end filtration with a Mott{sup TM} filter media grade 5. Subsequently, the samples were run through 10-milliliter ion exchange columns containing crystalline silicotitanate to assess the dynamic ion exchange performance of these feeds. Test results demonstrated that the planned TSCR operations should meet process performance expectations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Developing Waste-Driven Design Requirements for Filtration and Ion-Exchange at the Hanford LAWPS Facility - 16394

The United States Department of Energy is building the Low Activity Waste Pretreatment System (LAWPS) at the Hanford site near Richland, Washington to treat liquid tank waste. The primary unit operations are filtration for solids removal and ion-exchange for cesium-137 removal. The properties of the stored waste are diverse, therefore the design requirements need to allow for a variety of feeds from the Hanford tank farms. However, it is not cost effective to allow a few rare feeds to define the requirements when there are other options for treating the rare wastes. The waste-derived design requirements were based on trends from this data. The primary feed requirements that will drive filtration and ion-exchange performance are solids content of the feed, cesium to sodium ratio, and potassium concentration. Additionally, aluminum and total organic carbon (TOC) concentrations are considered for flammable gas generation. For the cesium and potassium concentrations, the available experimental data was collected, sorted, and compared against the historic requirements. The design basis for cesium and potassium feed parameters developed here enveloped all but a couple outlier tanks. A review of available grab sample data indicates that occasionally the samples would have up to 0.8 wt% solids concentration. One single sample had 3.3 wt% solids concentration. These solids concentrations were assigned as the nominal and upper bounding solids concentrations. Flammable gas generation does not directly impact the ion exchange process throughput but does impact the design safety requirements, thus TOC and aluminum concentrations (which are inputs to the flammable gas calculations) were examined in a similar way, but were paired together through a simplified correlation to reach an upper bounding value of 0.6 wt% TOC*Al{sup 0.4}. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗