Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CAT SCANNING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Region-of-interest image reconstruction with intensity weighting in circular cone-beam CT for image-guided radiation therapy

Imaging plays a vital role in radiation therapy and with recent advances in technology considerable emphasis has been placed on cone-beam CT (CBCT). Attaching a kV x-ray source and a flat panel detector directly to the linear accelerator gantry has enabled progress in target localization techniques, which can include daily CBCT setup scans for some treatments. However, with an increasing number of CT scans there is also an increasing concern for patient exposure. An intensity-weighted region-of-interest (IWROI) technique, which has the potential to greatly reduce CBCT dose, in conjunction with the chord-based backprojection-filtration (BPF) reconstruction algorithm, has been developed and its feasibility in clinical use is demonstrated in this article. A nonuniform filter is placed in the x-ray beam to create regions of two different beam intensities. In this manner, regions outside the target area can be given a reduced dose but still visualized with a lower contrast to noise ratio. Image artifacts due to transverse data truncation, which would have occurred in conventional reconstruction algorithms, are avoided and image noise levels of the low- and high-intensity regions are well controlled by use of the chord-based BPF reconstruction algorithm. The proposed IWROI technique can play an important role in image-guided radiation therapy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computer-aided measurement of liver volumes in CT by means of geodesic active contour segmentation coupled with level-set algorithms

Purpose: Computerized liver extraction from hepatic CT images is challenging because the liver often abuts other organs of a similar density. The purpose of this study was to develop a computer-aided measurement of liver volumes in hepatic CT. Methods: The authors developed a computerized liver extraction scheme based on geodesic active contour segmentation coupled with level-set contour evolution. First, an anisotropic diffusion filter was applied to portal-venous-phase CT images for noise reduction while preserving the liver structure, followed by a scale-specific gradient magnitude filter to enhance the liver boundaries. Then, a nonlinear grayscale converter enhanced the contrast of the liver parenchyma. By using the liver-parenchyma-enhanced image as a speed function, a fast-marching level-set algorithm generated an initial contour that roughly estimated the liver shape. A geodesic active contour segmentation algorithm coupled with level-set contour evolution refined the initial contour to define the liver boundaries more precisely. The liver volume was then calculated using these refined boundaries. Hepatic CT scans of 15 prospective liver donors were obtained under a liver transplant protocol with a multidetector CT system. The liver volumes extracted by the computerized scheme were compared to those traced manually by a radiologist, used as ''gold standard.''Results: The mean liver volume obtained with our scheme was 1504 cc, whereas the mean gold standard manual volume was 1457 cc, resulting in a mean absolute difference of 105 cc (7.2%). The computer-estimated liver volumetrics agreed excellently with the gold-standard manual volumetrics (intraclass correlation coefficient was 0.95) with no statistically significant difference (F=0.77; p(F{<=}f)=0.32). The average accuracy, sensitivity, specificity, and percent volume error were 98.4%, 91.1%, 99.1%, and 7.2%, respectively. Computerized CT liver volumetry would require substantially less completion time (compared to an average of 39 min per case by manual segmentation). Conclusions: The computerized liver extraction scheme provides an efficient and accurate way of measuring liver volumes in CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-E-17A-04: Geometric Validation of K-Space Self-Gated 4D-MRI Vs. 4D-CT Using A Respiratory Motion Phantom

Purpose: 4D-CT is often limited by motion artifacts, low temporal resolution, and poor phase-based target definition. We recently developed a novel k-space self-gated 4D-MRI technique with high spatial and temporal resolution. The goal here is to geometrically validate 4D-MRI using a MRI-CT compatible respiratory motion phantom and comparison to 4D-CT. Methods: 4D-MRI was acquired using 3T spoiled gradient echo-based 3D projection sequences. Respiratory phases were resolved using self-gated k-space lines as the motion surrogate. Images were reconstructed into 10 temporal bins with 1.56×1.56×1.56mm3. A MRI-CT compatible phantom was designed with a 23mm diameter ball target filled with highconcentration gadolinium(Gd) gel embedded in a 35×40×63mm3 plastic box stabilized with low-concentration Gd gel. The whole phantom was driven by an air pump. Human respiratory motion was mimicked using the controller from a commercial dynamic phantom (RSD). Four breathing settings (rates/depths: 10s/20mm, 6s/15mm, 4s/10mm, 3s/7mm) were scanned with 4D-MRI and 4D-CT (slice thickness 1.25mm). Motion ground-truth was obtained from input signals and real-time video recordings. Reconstructed images were imported into Eclipse(Varian) for target contouring. Volumes and target positions were compared with ground-truth. Initial human study was investigated on a liver patient. Results: 4D-MRI and 4D-CT scans for the different breathing cycles were reconstructed with 10 phases. Target volume in each phase was measured for both 4D-CT and 4D-MRI. Volume percentage difference for the 6.37ml target ranged from 6.67±5.33 to 11.63±5.57 for 4D-CT and from 1.47±0.52 to 2.12±1.60 for 4D-MRI. The Mann-Whitney U-test shows the 4D-MRI is significantly superior to 4D-CT (p=0.021) for phase-based target definition. Centroid motion error ranges were 1.35–1.25mm (4D-CT), and 0.31–0.12mm (4D-MRI). Conclusion: The k-space self-gated 4D-MRI we recently developed can accurately determine phase-based target volume while avoiding typical motion artifacts found in 4D-CT, and is being further studied for use in GI targeting and motion management. This work supported in part by grant 1R03CA173273-01.

60 APPLIED LIFE SCIENCES↗

Four-Dimensional Measurement of the Displacement of Internal Fiducial and Skin Markers During 320-Multislice Computed Tomography Scanning of Breast Cancer

Purpose: To study the three-dimensional movement of internal tumor bed fiducial and breast skin markers, using 320-multislice computed tomography (CT); and to analyze intrafractional errors for breast cancer patients undergoing breast irradiation. Methods and Materials: This study examined 280 markers on the skin of the breast (200 markers) and on the primary tumor bed (80 markers) of 20 patients treated by external-beam photon radiotherapy. Motion assessment was analyzed in 41 respiratory phases during 20 s of cine CT in the radiotherapy position. To assess intrafractional errors resulting from respiratory motion, four-dimensional CT scans were acquired for 20 patients. Results: Motion in the anterior-posterior (A/P) and superior-inferior (S/I) directions showed a strong correlation (|r| > 0.7) with the respiratory curve for most markers (79% and 70%, respectively). The average marker displacements between maximum and minimum value during 20 s for the 200 breast skin metal markers were 1.1 {+-} 0.3 mm, 2.1 {+-} 0.6 mm, and 1.6 {+-} 0.4 mm in the left-right, A/P, and S/I directions, respectively. For the 80 tumor bed clips, displacements were 0.9 {+-} 0.2 mm in left-right, 1.7 {+-} 0.5 mm in A/P, and 1.1 {+-} 0.3 mm in S/I. There was no significant difference in the motion between breast quadrant regions or between the primary site and the other regions. Conclusions: Motion in primary breast tumors was evaluated with 320-multislice CT. Very little change was detected during individual radiation treatment fractions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-225: It Is Necessary to Contouring the Brainstem On MRI Images in Radiotherapy of Head and Neck Cancer

Purpose: To analyze the error in contouring the brainstem for patients with head and neck cancer who underwent radiotherapy based on computed tomography (CT) and magnetic resonance (MR) images. Methods: 20 brain tumor and 17 nasopharyngeal cancer patients were randomly selected. Each patient underwent MR and CT scanning. For each patient, one observer contoured the brainstem on CT and MR images for 10 times, and 10 observers from five centers delineated the brainstem on CT and MR images only one time. The inter- and intra-observers volume and outline variations were compared. Results: The volumes of brainstem contoured by inter- and intra-observers on CT and MR images were similar (p>0.05). The reproducibility of contouring brainstem on MR images was better than that on CT images (p<0.05) for both inter- and intra-observer variability. The inter- and intra-observer for contouring on CT images reached mean values of 0.81±0.05 (p>0.05) and of 0.85±0.05 (p>0.05), respectively, while on MR images these respective values were 0.90±0.05 (p>0.05) and 0.92±0.04 (p>0.05). Conclusion: Contouring the brainstem on MR images was more accurate and reproducible than that on CT images. Precise information might be more helpful for protecting the brainstem radiation injury the patients whose lesion were closed to brainstem.

60 APPLIED LIFE SCIENCES↗

Regional Lung Density Changes After Radiation Therapy for Tumors in and Around Thorax

Purpose: To study the temporal nature of regional lung density changes and to assess whether the dose-dependent nature of these changes is associated with patient- and treatment-associated factors. Methods and Materials: Between 1991 and 2004, 118 patients with interpretable pre- and post-radiation therapy (RT) chest computed tomography (CT) scans were evaluated. Changes in regional lung density were related to regional dose to define a dose-response curve (DRC) for RT-induced lung injury using three-dimensional planning tools and image fusion. Multiple post-RT follow-up CT scans were evaluated by fitting linear-quadratic models of density changes on dose with time as the covariate. Various patient- and treatment-related factors were examined as well. Results: There was a dose-dependent increase in regional lung density at nearly all post-RT follow-up intervals. The population volume-weighted changes evolved over the initial 6-month period after RT and reached a plateau thereafter (p < 0.001). On univariate analysis, patient age greater than 65 years (p = 0.003) and/or the use of pre-RT surgery (p < 0.001) were associated with significantly greater changes in CT density at both 6 and 12 months after RT, but the magnitude of this effect was modest. Conclusions: There appears to be a temporal nature for the dose-dependent increases in lung density. Nondosimetric clinical factors tend to have no, or a modest, impact on these changes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric aspects of inverse-planned modulated-arc total-body irradiation

Purpose: To develop optimal beam parameters and to verify the dosimetric aspects of the recently developed modulated-arc total-body irradiation (MATBI) technique, which delivers an inverse-planned dose to the entire body using gantry rotation. Methods: The patient is positioned prone and supine underneath the gantry at about 2 m source-to-surface distance (SSD). Then, up to 28 beams irradiate the patient from different gantry angles. Based on full-body computed-tomography (CT) images of the patient, the weight of each beam is optimized, using inverse planning, to create a uniform body dose. This study investigates how to best simulate patients and the ideal beam setup parameters, such as field size, number of beams, and beam geometry, for treatment time and dose homogeneity. In addition, three anthropomorphic water phantoms were constructed and utilized to verify the accuracy of dose delivery, with both diode array and ion chamber measurements. Furthermore, to improve the accuracy of the new technique, a beam model is created specifically for the extended-SSD positioning for MATBI. Results: Low dose CT scans can be utilized for dose calculations without affecting the accuracy. The largest field size of 40 Multiplication-Sign 40 cm{sup 2} was found to deliver the most uniform dose in the least amount of time. Moreover, a higher number of beams improves dose homogeneity. The average dose discrepancy between ion chamber measurements and extended-SSD beam model calculations was 1.2%, with the largest discrepancy being 3.2%. This average dose discrepancy was 1.4% with the standard beam model for delivery at isocenter. Conclusions: The optimum beam setup parameters, regarding dose uniformity and treatment duration, are laid out for modulated-arc TBI. In addition, the presented dose measurements show that these treatments can be delivered accurately. These measurements also indicated that a new beam model did not significantly improve the accuracy of dose calculations. The optimum beam setup parameters along with the measurements performed to ensure accurate dose delivery serve as a useful guide for the clinical implementation of MATBI.

60 APPLIED LIFE SCIENCES↗

Clinical Factors Associated With Seroma Volume Reduction in Breast-Conserving Therapy for Early-Stage Breast Cancer: A Multi-Institutional Analysis

Purpose: To correlate clinical factors with seroma volume and reduction; and to determine whether cone-beam CT (CBCT) could be used clinically to monitor seroma reduction. Patients and Methods: This investigation included 102 women from five institutions with stage T1-2 breast cancer treated with breast-conserving therapy. Two CT scans were acquired: the planning CT (CT1) and a second CT (CT2) during radiotherapy (RT). Seroma was contoured on all scans, and correlations between seroma characteristics and clinical factors were investigated by univariate and multivariate analyses. In a substudy, 10 of the 102 patients received multiple CBCT scans during RT. Seroma were contoured by two observers in the substudy. Fifteen time points at which CT and CBCT were performed within 2 days were identified. The levels of correlation in seroma contours between CBCT and CT and between the two observers were examined. Results: The mean relative seroma reduction from CT1 to CT2 was 54% (p < 0.001). A significant inverse relationship was found between relative seroma reduction per week and number of RT fractions given by univariate and multivariate analyses (p = 0.01, 0.03). The mean difference in contoured seroma volumes between CT and CBCT was 12% (3.3 cm{sup 3}). When assessing the relative difference in seroma contours between Observer 1 and Observer 2, an interobserver difference of 12% was demonstrated. Neither discrepancy was clinically significant. Conclusions: Radiotherapy seems to hinder seroma reduction. Volume discrepancies between CBCT and CT were minor, with low interobserver variation, indicating that CBCT might be useful in monitoring seroma reduction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Study of dose calculation on breast brachytherapy using prism TPS

PRISM is one of non-commercial Treatment Planning System (TPS) and is developed at the University of Washington. In Indonesia, many cancer hospitals use expensive commercial TPS. This study aims to investigate Prism TPS which been applied to the dose distribution of brachytherapy by taking into account the effect of source position and inhomogeneities. The results will be applicable for clinical Treatment Planning System. Dose calculation has been implemented for water phantom and CT scan images of breast cancer using point source and line source. This study used point source and line source and divided into two cases. On the first case, Ir-192 seed source is located at the center of treatment volume. On the second case, the source position is gradually changed. The dose calculation of every case performed on a homogeneous and inhomogeneous phantom with dimension 20 × 20 × 20 cm{sup 3}. The inhomogeneous phantom has inhomogeneities volume 2 × 2 × 2 cm{sup 3}. The results of dose calculations using PRISM TPS were compared to literature data. From the calculation of PRISM TPS, dose rates show good agreement with Plato TPS and other study as published by Ramdhani. No deviations greater than ±4% for all case. Dose calculation in inhomogeneous and homogenous cases show similar result. This results indicate that Prism TPS is good in dose calculation of brachytherapy but not sensitive for inhomogeneities. Thus, the dose calculation parameters developed in this study were found to be applicable for clinical treatment planning of brachytherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-G-BRD-07: Investigation of Distal Lung Atelectasis Following Stereotactic Body Radiation Therapy Using Regional Lung Volume Changes Between Pre- and Post- Treatment CT Scans

Purpose: To propose a quantitative method using lung deformations to differentiate between radiation-induced fibrosis and potential airway stenosis with distal atelectasis in patients treated with stereotactic body radiation therapy (SBRT) for lung tumors. Methods: Twenty-four lung patients with large radiation-induced density increases outside the high dose region had their pre- and post-treatment CT scans manually registered. They received SBRT treatments at our institution between 2002 and 2009 in 3 or 5 fractions, to a median total dose of 54Gy (range, 30–60). At least 50 anatomical landmarks inside the lung (airway branches) were paired for the pre- and post-treatment scans to guide the deformable registration of the lung structure, which was then interpolated to the whole lung using splines. Local volume changes between the planning and follow-up scans were calculated using the deformation field Jacobian. Hyperdense regions were classified as atelectatic or fibrotic based on correlations between regional density increases and significant volume contractions compared to the surrounding tissues. Results: Out of 24 patients, only 7 demonstrated a volume contraction that was at least one σ larger than the remaining lung average. Because they did not receive high doses, these shrunk hyperdense regions were likely showing distal atelectasis resulting from radiation-induced airway stenosis rather than conventional fibrosis. On average, the hyperdense regions extended 9.2 cm farther than the GTV contours but not significantly more than 8.6 cm for the other patients (p>0.05), indicating that a large offset between the radiation and hyperdense region centers is not a good surrogate for atelectasis. Conclusion: A method based on the relative comparison of volume changes between different dates was developed to identify potential lung regions experiencing distal atelectasis. Such a tool is essential to study which lung structures need to be avoided to prevent atelectasis and limit lung function loss.

60 APPLIED LIFE SCIENCES↗

Three-Dimensional Imaging in Gynecologic Brachytherapy: A Survey of the American Brachytherapy Society

Purpose: To determine current practice patterns with regard to three-dimensional (3D) imaging for gynecologic brachytherapy among American Brachytherapy Society (ABS) members. Methods and Materials: Registered physician members of the ABS received a 19-item survey by e-mail in August 2007. This report excludes physicians not performing brachytherapy for cervical cancer. Results: Of the 256 surveys sent, we report results for 133 respondents who perform one or more implantations per year for locally advanced cervical cancer. Ultrasound aids 56% of physicians with applicator insertion. After insertion, 70% of physicians routinely obtain a computed tomography (CT) scan. The majority (55%) use CT rather than X-ray films (43%) or magnetic resonance imaging (MRI; 2%) for dose specification to the cervix. However, 76% prescribe to Point A alone instead of using a 3D-derived tumor volume (14%), both Point A and tumor volume (7%), or mg/h (3%). Those using 3D imaging routinely contour the bladder and rectum (94%), sigmoid (45%), small bowel (38%), and/or urethra (8%) and calculate normal tissue dose-volume histogram (DVH) analysis parameters including the D2cc (49%), D1cc (36%), D0.1cc (19%), and/or D5cc (19%). Respondents most commonly modify the treatment plan based on International Commission on Radiation Units bladder and/or rectal point dose values (53%) compared with DVH values (45%) or both (2%). Conclusions: More ABS physician members use CT postimplantation imaging than plain films for visualizing the gynecologic brachytherapy apparatus. However, the majority prescribe to Point A rather than using 3D image based dosimetry. Use of 3D image-based treatment planning for gynecologic brachytherapy has the potential for significant growth in the United States.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Artifacts in Conventional Computed Tomography (CT) and Free Breathing Four-Dimensional CT Induce Uncertainty in Gross Tumor Volume Determination

Purpose: Artifacts impacting the imaged tumor volume can be seen in conventional three-dimensional CT (3DCT) scans for planning of lung cancer radiotherapy but can be reduced with the use of respiration-correlated imaging, i.e., 4DCT or breathhold CT (BHCT) scans. The aim of this study was to compare delineated gross tumor volume (GTV) sizes in 3DCT, 4DCT, and BHCT scans of patients with lung tumors. Methods and Materials: A total of 36 patients with 46 tumors referred for stereotactic radiotherapy of lung tumors were included. All patients underwent positron emission tomography (PET)/CT, 4DCT, and BHCT scans. GTVs in all CT scans of individual patients were delineated during one session by a single physician to minimize systematic delineation uncertainty. The GTV size from the BHCT was considered the closest to true tumor volume and was chosen as the reference. The reference GTV size was compared to GTV sizes in 3DCT, at midventilation (MidV), at end-inspiration (Insp), and at end-expiration (Exp) bins from the 4DCT scan. Results: The median BHCT GTV size was 4.9 cm{sup 3} (0.1-53.3 cm{sup 3}). Median deviation between 3DCT and BHCT GTV size was 0.3 cm{sup 3} (-3.3 to 30.0 cm{sup 3}), between MidV and BHCT size was 0.2 cm{sup 3} (-5.7 to 19.7 cm{sup 3}), between Insp and BHCT size was 0.3 cm{sup 3} (-4.7 to 24.8 cm{sup 3}), and between Exp and BHCT size was 0.3 cm{sup 3} (-4.8 to 25.5 cm{sup 3}). The 3DCT, MidV, Insp, and Exp median GTV sizes were all significantly larger than the BHCT median GTV size. Conclusions: In the present study, the choice of CT method significantly influenced the delineated GTV size, on average, leading to an increase in GTV size compared to the reference BHCT. The uncertainty caused by artifacts is estimated to be in the same magnitude as delineation uncertainty and should be considered in the design of margins for radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accuracy Evaluation of a 3-Dimensional Surface Imaging System for Guidance in Deep-Inspiration Breath-Hold Radiation Therapy

Purpose: To investigate the applicability of 3-dimensional (3D) surface imaging for image guidance in deep-inspiration breath-hold radiation therapy (DIBH-RT) for patients with left-sided breast cancer. For this purpose, setup data based on captured 3D surfaces was compared with setup data based on cone beam computed tomography (CBCT). Methods and Materials: Twenty patients treated with DIBH-RT after breast-conserving surgery (BCS) were included. Before the start of treatment, each patient underwent a breath-hold CT scan for planning purposes. During treatment, dose delivery was preceded by setup verification using CBCT of the left breast. 3D surfaces were captured by a surface imaging system concurrently with the CBCT scan. Retrospectively, surface registrations were performed for CBCT to CT and for a captured 3D surface to CT. The resulting setup errors were compared with linear regression analysis. For the differences between setup errors, group mean, systematic error, random error, and 95% limits of agreement were calculated. Furthermore, receiver operating characteristic (ROC) analysis was performed. Results: Good correlation between setup errors was found: R{sup 2}=0.70, 0.90, 0.82 in left-right, craniocaudal, and anterior-posterior directions, respectively. Systematic errors were {<=}0.17 cm in all directions. Random errors were {<=}0.15 cm. The limits of agreement were -0.34-0.48, -0.42-0.39, and -0.52-0.23 cm in left-right, craniocaudal, and anterior-posterior directions, respectively. ROC analysis showed that a threshold between 0.4 and 0.8 cm corresponds to promising true positive rates (0.78-0.95) and false positive rates (0.12-0.28). Conclusions: The results support the application of 3D surface imaging for image guidance in DIBH-RT after BCS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Dosimetric Parameters and Disease Response After {sup 125}Iodine Transperineal Brachytherapy for Low- and Intermediate-Risk Prostate Cancer

Purpose: To analyze dosimetric outcomes after permanent brachytherapy for men with low-risk and 'low-tier' intermediate-risk prostate cancer and explore the relationship between the traditional dosimetric values, V100 (volume of prostate receiving 100% of the prescribed dose) and D90 (minimum dose to 90% of the prostate), and risk of biochemical failure. Methods and Materials: A total of 1,006 consecutive patients underwent implantation between July 20, 1998, and Oct 23, 2003. Most (58%) had low-risk disease; the remaining 42% comprised a selected low-tier subgroup of intermediate-risk patients. The prescribed minimum peripheral dose (MPD) was 144 Gy. All implants used 0.33 mCi {sup 125}I sources using a preplan technique featuring right-left symmetry and a strong posterior-peripheral dose bias. Sixty-five percent of patients had 6 months of androgen deprivation therapy. Postimplantation dosimetry was calculated using day-28 CT scans. Results: With a median follow-up of 54 months, the actuarial 5-year rate of freedom from biochemical recurrence (bNED) was 95.6% {+-} 1.6%. Median D90 was 105% of MPD, median V100 was 92%, median V150 was 58%, and median V200 was 9%. Dosimetric values were not predictive of biochemical recurrence on univariate or multivariate analysis. Analysis of dosimetric values by implantation number showed statistically significant increases in all values with time (D90, V100, V150, and V200; p < 0.001), but this did not translate into improved bNED. Conclusions: In contrast to some previous studies, dosimetric outcomes did not correlate with biochemical recurrence in the first 1,006 patients treated with {sup 125}I prostate brachytherapy at the British Columbia Cancer Agency. Despite a median D90 of only 105% of MPD, our bNED rates are indistinguishable from series that reported higher D90 values.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterizing Interfraction Variations and Their Dosimetric Effects in Prostate Cancer Radiotherapy

Purpose: To quantitatively characterize the interfraction variations and their dosimetric effects in radiotherapy for prostate cancer. Methods and Materials: A total of 486 daily computed tomography (CT) sets acquired for 20 prostate cancer patients treated with daily CT-guided repositioning using a linear accelerator and CT-on-rail combination were analyzed. The prostate, rectum, and bladder, delineated on each daily CT data set, were compared with those from the planning CT scan. Several quantities, including Dice's coefficient and the maximal overlapping rate, were used to characterize the interfraction variations. The delivered dose was reconstructed by applying the original plan to the daily CT scan with consideration of proper repositioning. Results: The mean prostate Dice's coefficient and maximal overlapping rate after bony registration was 69.7% {+-} 13.8% (standard deviation) and 85.6% {+-} 7.8% (standard deviation), respectively. The daily delivered dose distributions were generally inferior to the planned dose distribution for target coverage and/or normal structure sparing. For example, for approximately 5% of the treatment fractions, the prostate volume receiving 100% of the prescription dose decreased dramatically (15-20%) compared with its planned value. The magnitudes of the interfraction variations and their dosimetric effects indicated that, statistically, current standard repositioning using prostate alignment might be adequate for two-thirds of the fractions, but for the rest of the fractions, better on-line correction strategies, such as on-line replanning, are needed. Conclusion: Different adaptive correction schemes for prostatic interfraction changes can be used according to the anatomic changes, as quantified by the organ displacement and deformation parameters. On-line replanning is needed for approximately one-third of the treatment fractions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-E-17A-10: Markerless Lung Tumor Tracking Based On Beams Eye View EPID Images

Purpose: Dynamic tumor tracking or motion compensation techniques have proposed to modify beam delivery following lung tumor motion on the flight. Conventional treatment plan QA could be performed in advance since every delivery may be different. Markerless lung tumor tracking using beams eye view EPID images provides a best treatment evaluation mechanism. The purpose of this study is to improve the accuracy of the online markerless lung tumor motion tracking method. Methods: The lung tumor could be located on every frame of MV images during radiation therapy treatment by comparing with corresponding digitally reconstructed radiograph (DRR). A kV-MV CT corresponding curve is applied on planning kV CT to generate MV CT images for patients in order to enhance the similarity between DRRs and MV treatment images. This kV-MV CT corresponding curve was obtained by scanning a same CT electron density phantom by a kV CT scanner and MV scanner (Tomotherapy) or MV CBCT. Two sets of MV DRRs were then generated for tumor and anatomy without tumor as the references to tracking the tumor on beams eye view EPID images. Results: Phantom studies were performed on a Varian TrueBeam linac. MV treatment images were acquired continuously during each treatment beam delivery at 12 gantry angles by iTools. Markerless tumor tracking was applied with DRRs generated from simulated MVCT. Tumors were tracked on every frame of images and compared with expected positions based on programed phantom motion. It was found that the average tracking error were 2.3 mm. Conclusion: This algorithm is capable of detecting lung tumors at complicated environment without implanting markers. It should be noted that the CT data has a slice thickness of 3 mm. This shows the statistical accuracy is better than the spatial accuracy. This project has been supported by a Varian Research Grant.

60 APPLIED LIFE SCIENCES↗

SU-E-T-560: Commissioning An HDR Freiburg Flap Applicator for Skin Lesion Treatment

Purpose: Flexible Freiburg flap used with high dose rate afterloaders is easy to cut into any size for any body site and to dwell with a precise source position, conforms to curved skin surface and then to the planned target. However, unlike intracavity or interstitial situations, incomplete scatter environment due to flap applicators exposed to air might lead to dose difference between the delivered and planned. This research is focused on the dose deviation of incomplete scatter versus full scatter. Methods: A 12x12 cm of Freiburg flap applicator was used for the validation. A Nucletron Oncentra Brachy Ver. 4.3 treatment planning system (TPS) was used for treatment planning. However, no heterogeneity correction incorporated into the brachytherap TPS needs to be considered. A Philips Brilliance CT Big Bore was employed for CT scan. Radiation was delivered using a Nucletron HDR remote afterloader system. A 10cm bolus was used to cover the flap for obtaining a full scatter. An OSL, ion chamber, and Gafchromic EBT2 film were used for commissioning the flap applicator. Results: The applicator calibration at 5mm depth was performed using an OSL dosimeter. Applicator source dwelling positions with 1D and 2D array exposed to and recorded by Gafchromic EBT2 film showed an agreement within 1mm. 1D array of Freiburg flap exhibited 4.2% cooler in dose with incomplete scatter than full scatter. 2D array showed 7.1% lower in dose for incomplete scatter than full scatter. The deviation was found more than 10% beyond 8cm in depth. Conclusion: Significant dose deviation caused by the incomplete scatter environment was found to be 7.1% at 1cm depth. This deviation was increased with increasing depth. The inaccuracy resulted from the incomplete scatter can be fixed by either placing a bolus on the top of the flap or making the plan at least 7% hotter.

07 ISOTOPE AND RADIATION SOURCES↗

Value of Combined PET/CT for Radiation Planning in CT-Guided Percutaneous Interstitial High-Dose-Rate Single-Fraction Brachytherapy for Colorectal Liver Metastases

Purpose: To determine the additional value of fluorodeoxyglucose-positron emission tomography (PET) for clinical target volume definition in the planning of computed tomography (CT)-guided interstitial brachytherapy for liver metastases. Patients and Methods: A total of 19 patients with liver metastases from colorectal cancer treated in 25 sessions were included in the present study. All patients had undergone fluorodeoxyglucose-PET for patient evaluation before interstitial CT-guided brachytherapy. A contrast-enhanced CT scan of the upper abdomen was obtained for radiation planning. The clinical target volume (CTV) was defined by a radiation oncologist and radiologist. After registration of the CT scan with the PET data set, the target volume was defined again using the fusion images. Results: PET revealed one additional liver lesion that was not visible on CT. The median CT-CTV (defined using CT and magnetic resonance imaging) was 68 cm{sup 3} (range 4-260). The PET/CT-CTV (median, 78 cm{sup 3}; range, 4-273) was significantly larger, with a median gain of 24.5% (interquartile range, 2.1-71.5%; p = .022). An increased CTV was observed in 15 cases and a decrease in 6; in 4 cases, the CT-CTV and PET/CT-CTV were equal. Incomplete dose coverage of PET/CT-CTVs was indicative of early local progression (p = .004); however, CT-based radiation plans did not show significant differences in the local control rates when stratified by dose coverage. Conclusion: Retrospective implementation of fluorodeoxyglucose-PET for CTV specification for CT-guided brachytherapy for colorectal liver metastases revealed a significant change in the CTVs. Additional PET-positive tumor regions with incomplete dose coverage could explain unexpected early local progression.

62 RADIOLOGY AND NUCLEAR MEDICINE↗