Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Buildings”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Building thermal model development of typical house in U.S. for virtual storage control of aggregated building loads based on limited available information

A building thermal model is an essential component for achieving optimal control of a building’s heating, ventilation, and air conditioning (HVAC). A self-learning grey-box model has been developed by implementing data-driven techniques and utilizing limited available information about the building. In previous research, detailed foreknown knowledge/information, e.g. physical and thermal properties of building materials, as well as sufficient number of observation points, e.g. indoor temperature sensors in different zones, are available for making the decision of model structure and parameters searching range easier. The availability of measured data and a narrowed searching range of model parameters, e.g. resistance and capacity for each wall, made the adopted algorithms quickly achieve near optimal values, which closely approximate the actual heat transfer of a building. Meanwhile, the details of pre-processing of the key inputs were seldom explained. Compared to the previous research, in this study, the available information is assumed to be limited which can fill the requirement for large scale virtual storage control of real residential community in near future, where it may be impractically or over time-consuming to acquire the detailed information for each single house. The developed model is validated by comparing the results to measured data in a recently-built home typical of the southeastern United States.

Cui, Borui↗

Nationwide Energy Saving Potential Evaluation for Office Buildings with Occupant-Based Building Controls

The heating ventilation and air-conditioning (HVAC) system is a major contributor to building energy consumption. This paper aims to quantify the nationwide energy savings potential of implementing the occupancy-based control (OBC) for the HVAC system in typical medium-sized office buildings using a whole building simulation program (i.e., EnergyPlus). First, the medium-sized office from the DOE Commercial Prototype Building Models was modified to have detailed layout and space functions. Then, a statistic-algorithm-based tool was used to generate the dynamic occupancy schedules for various rooms. Next, both a baseline case and two OBC cases were created for the comparison based on the updated ASHRAE Standard 90.1 and ASHRAE Guideline 36. The HVAC operation in the baseline case follows a static occupancy schedule and fixed setpoint schedules for both room air temperatures and minimal system outside air flowrates, while the proposed OBC cases use the room temperature reset, system minimum outdoor airflow reset, and zone minimal supply airflow rate reset. These cases were extended to five climate zones in the United States to further quantify the energy savings potential associated with the OBC on a nationwide scale. The preliminary result of this case study shows that there could be significant energy savings potential from the proposed OBC strategies in medium-sized office buildings in the United States.

Pang, Zhihong↗

VENTSAR V3.0: A Python GUI for Estimating Contaminant Concentrations on or Near Buildings Due to Building Effects and Plume Rise and For Calculating Inhalation and Plume Shine Doses

VENTSAR: Originated as VENTAX (Smith and Weber 1983) on the IBM Mainframe at the Savannah River Site (SRS) as a Fortran program. Updated to VENTSAR XL V1.0 (Simpkins 1997) as a spreadsheet version using macros created in Microsoft Excel. Later updated to VENTSAR XL V2.0 (Dixon 2018) as a spreadsheet executing a modified version of the original VENTAX Fortran code. Estimates contaminant concentrations on or near a building from a release at a nearby location. Calculates concentrations for a given meteorological exceedance probability or for a given stability and wind speed combination. Can model a single building with or without a penthouse on top or a ground location from either a stack or ground release. Plume rise can be considered. Contaminant releases can be chemical or radioactive with downwind concentrations determined at user-specified distances. Wind passing over and around buildings creates a complicated dispersion pattern. Air-intake vents may be located on building roofs or near the ground downwind of a release source. An estimation of pollutant concentrations on or near a structure is important in determining expected pollutant levels. Meteorological data are selected based on a specific area of the site. Fortran-based VENTAX able to make fast, complex mathematical calculations. Not user-friendly VENTSAR XL V1.0 no longer supported due to obsolete Excel macros. VENTSAR XL V2.0 an interim solution using an Excel spreadsheet to interface with the modified VENTAX Fortran code. Requires user to have Microsoft Excel. Not an intuitive interface for someone unfamiliar with VENTSAR. Does not perform dose calculations. VENTSAR V3.0 goal to combine the strengths of previous versions of VENTSAR into a single, powerful yet user-friendly program with a Graphical User Interface (GUI). Not dependent upon a specific program or plug-ins. Self-contained package to be used on any computer running Microsoft Windows. User-friendly, intuitive GUI created in Python for parameter input. Executes same modified VENTAX Fortran code as VENTSAR XL V2.0. Outputs formatted text file of completed calculations for easy review and dissemination. Performs inhalation and plume shine dose calculations for up to 11 user-selected nuclides from a nuclide dose factor library of almost 500 nuclides. 12 test cases were created for verification of V1.0 and V2.0. Same test cases run in V3.0 to verify correct performance. V3.0 produced similar results to V1.0. Confirmed GUI did not alter calculations in any way. Comparisons of the test case results confirm the V3.0 GUI does not influence the VENTSAR calculations. Simply passes same input parameters to VENTAX Fortran code for execution. Provides end user an easy-to-use, intuitive tool to quickly make building effect and plume rise calculations, as well as, inhalation and plume shine dose calculations. No experience with or working knowledge of Fortran, Excel, command line, or macros required. Self-contained package allows VENTSAR be deployed to any Windows computer without the need for specific programs or plug-ins.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Surrogate model evaluation and building energy benchmarking for commercial buildings

Building energy consumption benchmarking involves challenges associated with various energy patterns for different building types; heating, ventilating, and air-conditioning (HVAC) system types; and climates. Given significant variation in energy use patterns, accurate prediction of long-term energy use using surrogate models remains challenging. Multiple linear regression (MLR) is commonly used for building energy benchmarking because of its simple structure; however, it lacks accuracy compared to other black-box models. Although many studies have compared surrogate models and offer guidance on model selection based on metrics, they do not provide detailed analysis on improving the surrogate model accuracy. In this paper, we implement a surrogate model using polynomial ridge regression (i.e., MLR with interaction terms combined with ridge regularization) for small office and retail strip mall buildings across six HVAC system types and all climate zones, for electricity and natural gas in baseline and proposed scenarios. A simulation workflow is developed using OpenStudio TM /EnergyPlus TM to generate simulation data using measures over a wide range of efficiency inputs. Enhancements based on statistical insights are used for improving the model accuracy using filters, input transformations, and change points. Surrogate models achieved average coefficient of variation of the root mean squared error (CVRMSE) values of 2.17, 1.06, 2.05, and 3.26 for proposed electricity, proposed natural gas, baseline electricity, and baseline natural gas, respectively, with enhancements reducing CVRMSE by an average of 14.9% across all combinations. We provide model interpretation via Shapley additive explanations to determine which input variables most influence energy consumption and provide supportive arguments for enhancements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model-based predictive control of multi-zone commercial building with a lumped building modelling approach

Here this study investigates the applicability of a lumped building modeling approach to model-based predictive control (MPC) to alleviate the complex modeling process of the grey-box multi-zone building model. Based on experimental data, two building models were estimated in this study. The detailed model as a reference case and a lumped model were estimated with decentralized and conventional approaches, respectively. Then, simulations were performed with two boundary conditions, including the comfort bound and electricity cost structure. The performances of the MPC with the detailed and lumped models were analyzed compared to the feedback control. More savings was achieved with a larger comfort bound and more aggressive electricity cost structure. The savings potential of the proposed lumped model approach was not as high as that of the detailed model. However, the proposed method yields good control performance, whose savings was approximately 8.6% over that of feedback control. These results suggest that the proposed method can be used to facilitate MPC implementation in multi-zone building applications.

42 ENGINEERING↗

Reducing Transaction Costs for Energy Efficiency Investments and Analysis of Economic Risk Associated With Building Performance Uncertainties: Small Buildings and Small Portfolios Program

The small buildings and small portfolios (SBSP) sector face a number of barriers that inhibit SBSP owners from adopting energy efficiency solutions. This pilot project focused on overcoming two of the largest barriers to financing energy efficiency in small buildings: disproportionately high transaction costs and unknown or unacceptable risk. Solutions to these barriers can often be at odds, because inexpensive turnkey solutions are often not sufficiently tailored to the unique circumstances of each building, reducing confidence that the expected energy savings will be achieved. To address these barriers, NREL worked with two innovative, forward-thinking lead partners, Michigan Saves and Energi, to develop technical solutions that provide a quick and easy process to encourage energy efficiency investments while managing risk. The pilot project was broken into two stages: the first stage focused on reducing transaction costs, and the second stage focused on reducing performance risk. In the first stage, NREL worked with the non-profit organization, Michigan Saves, to analyze the effects of 8 energy efficiency measures (EEMs) on 81 different baseline small office building models in Holland, Michigan (climate zone 5A). The results of this analysis (totaling over 30,000 cases) are summarized in a simple spreadsheet tool that enables users to easily sort through the results and find appropriate small office EEM packages that meet a particular energy savings threshold and are likely to be cost-effective.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

User-Preference-Driven Model Predictive Control of Residential Building Loads and Battery Storage for Demand Response: Preprint

This paper presents a user-preference-driven home energy management system (HEMS) for demand response (DR) with residential building loads and battery storage. The HEMS is based on a multi-objective model predictive control algorithm, where the objectives include energy cost, thermal comfort, and carbon emission. A multi-criterion decision making method originating from social science is used to quickly determine user preferences based on a brief survey and derive the weights of different objectives used in the optimization process. Besides the residential appliances used in the traditional DR programs, a home battery system is integrated into the HEMS to improve the flexibility and reliability of the DR resources. Simulation studies have been performed on field data from a residential building stock data set. Appliance models and usage patterns were learned from the data to predict the DR resource availability. Results indicate the HEMS was able to provide a significant amount of load reduction with less than 20% prediction error in both heating and cooling cases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Regional Carbon Emission Reduction Prediction via Retrofits of Commercial Buildings with a Case Study of US School Buildings in Hot Climates

Retrofitting commercial buildings has great potential to reduce carbon emissions as demonstrated by previous studies in some specific cities, but their regional carbon emission reduction potential is still unknown. Thus, we develop a method to predict the long-term regional carbon emission reduction potential by retrofitting commercial buildings. School buildings in hot climate zones in the continental U.S. are selected as an example. The results show that the aggregated carbon emission reduction potential of school buildings in that region reduces from 3.33 to 2.01 megatons from 2024 to 2050 due to the increased penetration of renewable energy.

building energy simulation↗

Building America Case Study: Boiler Control Replacement for Hydronically Heated Multifamily Buildings, Cambridge, Massachusetts (Fact Sheet)

The ARIES Collaborative, a U.S. Department of Energy Building America research team, partnered with NeighborWorks America affiliate Homeowners' Rehab Inc. (HRI) of Cambridge, Massachusetts, to study improvements to the central hydronic heating system in one of the nonprofit's housing developments. The heating controls in the three-building, 42-unit Columbia Cambridge Alliance for Spanish Tenants housing development were upgraded. Fuel use in the development was excessive compared to similar properties. A poorly insulated thermal envelope contributed to high energy bills, but adding wall insulation was not cost-effective or practical. The more cost-effective option was improving heating system efficiency. Efficient operation of the heating system faced several obstacles, including inflexible boiler controls and failed thermostatic radiator valves. Boiler controls were replaced with systems that offer temperature setbacks and one that controls heat based on apartment temperature in addition to outdoor temperature. Utility bill analysis shows that post-retrofit weather-normalized heating energy use was reduced by 10%-31% (average of 19%). Indoor temperature cutoff reduced boiler runtime (and therefore heating fuel consumption) by 28% in the one building in which it was implemented. Nearly all savings were obtained during night which had a lower indoor temperature cut off (68 degrees F) than day (73 degrees F). This implies that the outdoor reset curve was appropriately adjusted for this building for daytime operation. Nighttime setback of heating system supply water temperature had no discernable impact on boiler runtime or gas bills.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building Energy Asset Score for Building Owners

The Building Energy Asset Score is a national standardized tool for evaluating the physical and structural energy efficiency of commercial and multifamily residential buildings. The Asset Score generates a simple energy efficiency rating that enables comparison among buildings, and identifies opportunities for users to invest in energy efficiency upgrades. It is web-based and free to use. This fact sheet discusses the value of the score for building owners.

Building energy simulation, building envelope, hot↗

Building Energy Asset Score for Energy Services Companies, Engineers and Green Building Consultants

The Building Energy Asset Score is a national standardized tool for evaluating the physical and structural energy efficiency of commercial and multifamily residential buildings. The Asset Score generates a simple energy efficiency rating that enables comparison among buildings, and identifies opportunities for users to invest in energy efficiency upgrades. It is web-based and free to use. This fact sheet discusses the value of the score for energy services companies, engineers and green building consultants.

Building energy simulation, building envelope, hot↗

Effects of long-term climate change on global building energy expenditures

This paper explores potential future implications of climate change on building energy expenditures around the globe. Increasing expenditures result from increased electricity use for cooling, and are offset to varying degrees, depending on the region, by decreased energy consumption for heating. The analysis is conducted using a model of the global buildings sector within the GCAM integrated assessment model. The integrated assessment framework is valuable because it represents socioeconomic and energy system changes that will be important for understanding building energy expenditures in the future. Results indicate that changes in net expenditures are not uniform across the globe. Net expenditures decrease in some regions, such as Canada and Russia, where heating demands currently dominate, and increase the most in areas with less demand for space heating and greater demand for space cooling. We explain these results in terms of the basic drivers that link building energy expenditures to regional climate.

Climate change impacts↗

A conceptual model for how to design for building envelope characteristics. Impact of thermal comfort intervals and thermal mass on commercial buildings in U.S. climates

The paper presents a simplified conceptual model for energy demand calculations based on building envelope characteristics, thermal mass and local climate. It is based on a network model and lumped analysis of the dynamic process. Characteristic parameters for the buildings are suggested; Driving temperature (DT), Driving temperature difference, (DTD), External Load Temperature (ELT), and Thermal Load Resistance (TLR). The Building Envelope Performance ( BEP 0 ), based on a controlled constant indoor temperature is introduced. Solution techniques using stable explicit forward differences based on analytical solutions are derived. The conceptual model has been used for mapping the Driving temperature difference and introduced two performance factors and . The first factor represents the effect of thermal comfort interval and thermal mass on the energy demand. The latter represents the ratio between cooling and heating energy demand. These three parameters and factors have been visualized on U.S. maps and enable a possibility to communicate the demand of energy, and cooling and the coupling to building characteristics, in a concise way.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Assessment of a Photonic Radiative Cooling System for Office Buildings

Spectrally selective materials show high technical potential for use as radiative cooling heat exchangers for buildings. Recent work by Stanford University has applied a photonic approach to tailor the optical properties of a coating material. In a prototype test, a radiative cooler based on that photonic material has demonstrated the ability to maintain radiator surfaces at below-ambient temperatures in the presence of intense, direct sunlight. This paper presents the simulation and parametric analysis of photonic radiative cooling system that integrates the use of the photonic radiative cooler and radiant floor cooling via the whole energy simulation program EnergyPlus. The simulation was made for a medium office building with three floors and a total floor area of 5,000 m2. Three key design parameters including the storage tank size, the radiator area, and the number of floors are expected to have a large impact on system performance were investigated in this paper. The results show that the percentage of cooling electricity savings from the photonic radiative cooling system relative to a reference variable-air-volume system has a linear relationship with the radiator area, and a quadratic correlation with both tank size and the number of floors. The findings from this parametric analysis are valuable to understand how component sizing affects system performance.

Wang, Weimin↗

Streamlining the Design-to-Build Transition with Build-Optimization Software Tools

Scaling-up capabilities for the design, build, and test of synthetic biology constructs holds great promise for the development of new applications in fuels, chemical production, or cellular-behavior engineering. Construct design is an essential component in this process; however, not every designed DNA sequence can be readily manufactured, even using state-of-the-art DNA synthesis methods. Current biological computer-aided design and manufacture tools (bioCAD/CAM) do not adequately consider the limitations of DNA synthesis technologies when generating their outputs. Designed sequences that violate DNA synthesis constraints may require substantial sequence redesign or lead to price-premiums and temporal delays, which adversely impact the efficiency of the DNA manufacturing process. In this paper, we have developed a suite of build-optimization software tools (BOOST) to streamline the design-build transition in synthetic biology engineering workflows. BOOST incorporates knowledge of DNA synthesis success determinants into the design process to output ready-to-build sequences, preempting the need for sequence redesign. The BOOST web application is available at https://boost.jgi.doe.gov and its Application Program Interfaces (API) enable integration into automated, customized DNA design processes. Finally, the herein presented results highlight the effectiveness of BOOST in reducing DNA synthesis costs and timelines.

59 BASIC BIOLOGICAL SCIENCES↗

Coupling indoor airflow, HVAC, control and building envelope heat transfer in the Modelica Buildings library

Here, this paper describes a coupled dynamic simulation of an indoor environment with heating, ventilation, and air conditioning (HVAC) systems, controls and building envelope heat transfer. The coupled simulation can be used for the design and control of ventilation systems with stratified air distributions. Those systems are commonly used to reduce building energy consumption while improving the indoor environment quality. The indoor environment was simulated using the fast fluid dynamics (FFD) simulation programme. The building fabric heat transfer, HVAC and control system were modelled using the Modelica Buildings library. After presenting the concept, the mathematical algorithm and the implementation of the coupled simulation were introduced. The coupled FFD–Modelica simulation was then evaluated using three examples of room ventilation with complex flow distributions with and without feedback control. Lastly, further research and development needs were also discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A cosine-based correlation information entropy approach for building automatic fault detection baseline construction

Building automatic fault detection and diagnosis (AFDD) technologies have shown great potential for energy savings. To enable AFDD, a baseline depicting the normal operation mode is needed to detect whether the building operation deviates from normality. Existing research using physics-based knowledge and models for AFDD has mainly taken a trial-and-error approach to determine if a given baseline is sufficient via empirical experiments. A mechanism to support decisions such as how many samples and what samples should be included in the baseline is currently lacking. In this study, a data-driven method for AFDD baseline construction based on information entropy is developed. The entropy is derived based on cosine similarity among typical building automation system measurements in conjunction with outdoor weather information. The performance of the proposed method is evaluated using real building data. Evaluation results indicate that the fault detection strategy adopting the proposed method has similar or better accuracy in detecting faults compared to the same fault detection strategy using the baseline construction method from the literature. Additionally, the use of entropy enables the proposed method to automatically construct and assess the baseline consisting of information-rich samples.

42 ENGINEERING↗

Towards Off-policy Evaluation as a Prerequisite for Real-world Reinforcement Learning in Building Control

We present an initial study of off-policy evaluation (OPE), a problem prerequisite to real-world reinforcement learning (RL), in the context of building control. OPE is the problem of estimating a policy's performance without running it on the actual system, using historical data from the existing controller. It enables the control engineers to ensure a new, pretrained policy satisfies the performance requirements and safety constraints of a real-world system, prior to interacting with it. While many methods have been developed for OPE, no study has evaluated which ones are suitable for building operational data, which are generated by deterministic policies and have limited coverage of the state-action space. After reviewing existing works and their assumptions, we adopted the approximate model (AM) method. Furthermore, we used bootstrapping to quantify uncertainty and correct for bias. In a simulation study, we evaluated the proposed approach on 10 policies pretrained with imitation learning. On average, the AM method estimated the energy and comfort costs with 1.84% and 14.1% error, respectively.

Chen, B↗