Automatic bypass valve
Modified pressure-regulator valve developed for arc powered wind tunnels allows automatic, accurate, and easily adjustable transfer of excess airflow.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Modified pressure-regulator valve developed for arc powered wind tunnels allows automatic, accurate, and easily adjustable transfer of excess airflow.
The impact of the use of broad specification fuels on the design, performance durability, emissions and operational characteristics of combustors for commercial aircraft gas turbine engines was assessed. Single stage, vorbix and lean premixed prevaporized combustors, in the JT9D and an advanced energy efficient engine cycle were evaluated when operating on Jet A and ERBS (Experimental Referee Broad Specification) fuels. Design modifications, based on criteria evolved from a literature survey, were introduced and their effectiveness at offsetting projected deficiencies resulting from the use of ERBS was estimated. The results indicate that the use of a broad specification fuel such as ERBS, will necessitate significant technology improvements and redesign if deteriorated performance, durability and emissions are to be avoided. Higher radiant heat loads are projected to seriously compromise liner life while the reduced thermal stability of ERBS will require revisions to the engine-airframe fuel system to reduce the thermal stress on the fuel. Smoke and emissions output are projected to increase with the use of broad specification fuels. While the basic geometry of the single stage and vorbix combustors are compatible with the use of ERBS, extensive redesign of the front end of the lean premixed prevaporized burner will be required to achieve satisfactory operation and optimum emissions.
A stability-bleed system was installed in a YF-12 flight inlet that was subjected to internal and external airflow disturbances in the NASA Lewis 10 by 10 foot supersonic wind tunnel. The purpose of the system is to allow higher inlet performance while maintaining a substantial tolerance (without unstart) to internal and external disturbances. At Mach numbers of 2.47 and 2.76, the inlet tolerance to decreases in diffuser-exit corrected airflow was increased by approximately 10 percent of the operating-point airflow. The stability-bleed system complemented the terminal-shock-control system of the inlet and did not show interaction problems. For disturbances which caused a combined decrease in Mach number and increase in angle of attack, the system with valves operative kept the inlet started 4 to 28 times longer than with the valves inoperative. Hence, the stability system provides additional time for the inlet control system to react and prevent unstart. This was observed for initial Mach numbers of 2.55 and 2.68. For slow increase in angle of attack at Mach 2.47 and 2.76, the system kept the inlet started beyond the steady-state unstart angle. However, the maximum transient angles of attack without unstart could not be determined because wind-tunnel mechanical-stop limits for angle of attack were reached.
The results of engine performance deterioration investigations based on historical data, special engine tests, and specific tests to define the influence of flight loads and component clearances on performance are presented. The results of analyses of several damage mechanisms that contribute to performance deterioration such as blade tip rubs, airfoil surface roughness and erosion, and thermal distortion are also included. The significance of these damage mechanisms on component and overall engine performance is discussed.
The extent and magnitude of performance deterioration of the Pratt and Whitney JT9D, and the General Electric CF6 engine models is presented. Overall engine and contributing module performance deterioration with respect to flight cycles and/or time are analyzed. The overall engine performance deterioration analyses are based on data obtained from historical records, special engine tests, and tests for specific effects. Hardware inspection data from overhaul shops and special module tests are the basis for the modular performance deterioration data used in the analyses. Various damage mechanisms such as seal rubs, erosion, surface roughness and thermal distortion, and how they contribute to performance deterioration are included in the modular analyses. Results indicate that early performance deterioration occurring within the first few flights of these engines is less than 1 percent in cruise specific fuel consumption (SFC), that it is event oriented, and that it is the result of increased blade tip clearances. This performance deterioration gradually increases to about 2.5 to 3.0 percent (including the initial short term deterioration) after 2500 to 3000 flights where increased blade tip clearances, airfoil quality degradation, and thermal distortion are the contributing causes.
Static pressure and total pressure distributions were measured in the inlet duct upstream of the engine inlet and within the fan and compressor of a YTF34 turbofan engine. In addition, the free stream flow angle was measured between the distortion generator and the engine inlet. Distortions were generated using three screen configurations with extents of 90 deg or 180 deg. The screens were mounted on a rotatable screen assembly. Reynolds number index upstream of the distortion device was maintained at 0.5 or 0.2, and engine fan speed corrected to station 2 temperature was maintained at 80 or 90 percent of rated condition (7005 rpm). Flow angle was nearly constant near the distortion device and increased as flow approached the engine inlet. The largest flow angle occurred in the hub region of the engine inlet. Static pressure distortion along the inlet duct increased exponentially as the flow approached the engine. Both static pressure and total pressure distortions were attenuated between engine inlet and compressor exit.
Model scale jet noise data are presented for a variety of internal lobed mixer nozzle configurations for take off power settings in a static environment. The results are presented for a 17.5 cm diameter fan nozzle to show the effect on noise levels caused by changes in geometric shape of the internal, or core flow, nozzle. The geometric variables include the lobe discharge angle, the number of lobes, spacing between the center plug and lobe valley, lobe side wall shape and axial contour of the lobes. An annular plug core flow nozzle was also tested and is used as a baseline for comparative purposes. Comparison of data from the internal lobed configurations showed that for comparative effect, in terms of the effect on full scale perceived noise levels, was caused by a change in the lobe discharge angle. The results showed that increasing the discharge angle caused an increase as large as 7 dB in sound pressure levels in the high frequency portion of the spectra. Changes in the other geometric variables cause negligible effects.
(Previously cited in issue 19, p. 3265, Accession no. A81-40839)
(Previously announced in STAR as N83-12087)
(Previously cited in issue 19, p. 3265, Accession no. A81-40842)
Total-temperature, static-pressure and total-pressure distributions were measured in the inlet duct upstream of the engine inlet and within the fan and compressor of a YTF34 turbofan engine. Free-stream and boundary layer yaw angle variations were measured between a rotable screen assembly and the engine inlet. Total pressure distortions were generated using three 180 deg extent screens and total temperature distortions were generated using a rotatable hydrogen burner. Reynolds number index upstream of the rotatable screen assembly was maintained at 0.5 (based on the undistorted sectors at station 1, the inlet flow measuring station). The engine mechanical fan speed at sea level condition was rated at 7005 rpm. The engine was tested at a corrected fan speed of 90 percent of rated condition. Yaw angle increased between the rotatable screen assembly and the engine inlet. The largest variation in free-stream and boundary layer yaw angle occurs when the combined distortions are 180 deg out-of-phase. Static-pressure distortion increased exponentially as flow approached the engine. Total-pressure distortions were attenuated between the engine inlet and the compressor exit. Total-temperature distortion persisted through the compressor for all four combined distortions investigated.
Explore the source record for details and available documents.
Experimental measurements of both mean and conditionally sampled characteristics of laminar, transitional and low Reynolds number turbulent boundary layers on a heated flat plate are presented. Measurements were obtained in air over a range of freestream turbulence intensities from 0.3 percent to 6 percent with a freestream velocity of 30.5 m/s and zero pressure gradient. Conditional sampling performed in the transitional boundary layers indicate the existence of a near-wall drop in intermittency, especially pronounced at low intermittencies. Nonturbulent intervals were observed to possess large levels of low-frequency unsteadiness, and turbulent intervals had peak intensities as much as 50 percent higher than were measured at fully turbulent stations. Heat transfer results were consistent with results of previous researchers and Reynolds analogy factors were found to be well predicted by laminar and turbulent correlations which accounted for unheated starting length. A small dependence of the turbulent Reynolds analogy factors on freestream turbulence level was observed. Laminar boundary layer spectra indicated selective amplification of unstable frequencies. These instabilities appear to play a dominant role in the transition process only for the lowest freestream turbulence level studied, however.
Experimental measurements of both mean and conditionally sampled characteristics of laminar, transitional and low Reynolds number turbulent boundary layers on a heated flat plate are presented. Measurements were obtained in air over a range of freestream turbulence intensities from 0.3 percent to 6 percent with a freestream velocity of 30.5 m/s and zero pressure gradient. Conditional sampling performed in the transitional boundary layers indicate the existence of a near-wall drop in intermittency, especially pronounced at low intermittencies. Nonturbulent intervals were observed to possess large levels of low-frequency unsteadiness, and turbulent intervals had peak intensities as much as 50 percent higher than were measured at fully turbulent stations. Heat transfer results were consistent with results of previous researches and Reynolds analogy factors were found to be well predicted by laminar and turbulent correlations which accounted for unheated starting length. A small dependence of the turbulent Reynolds analogy factors on freestream turbulence level was observed. Laminar boundary layer spectra indicated selective amplification of unstable frequencies. These instabilities appear to play a dominant role in the transition process only for the lowest freestream turbulence level studied, however.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The study developed preliminary design concepts for the exploitation of the properties of LH2 in a turbofan engine intended for air transport use, and showed the benefits which accrue in reduction of aircraf direct operating cost. Design concepts for the engine fuel delivery and control system, including the engine high pressure fuel pump, were developed, and general concept feasibility was shown. For both the engine and the fuel delivery and control system, recommendations were made for the advanced development which is necessary to bring the technology to a state of readiness for design application. The study was of necessity abbreviated in nature: more intensive study of both the engine and fuel delivery and control system is recommended.
A flow-through inlet test program was conducted to evaluate inlet test methods and determine the impact of the fan on inlet separation when operating at large angles of attack. A total of 16 model configurations of approximately 1/6 scale were tested. A comparison of these flow-through results with powered data indicates the presence of the fan increased separation operation 3 degrees to 4 degrees over the flow through inlet. Rods and screens located at the fan face station, that redistribute the flow, achieved simulation of the powered-fan results for separation angle of attack. Concepts to reduce inlet distortion and increase angle of attack capability were also evaluated. Vortex generators located on the inlet surface increased inlet angle of attack capability up to 2 degrees and reduced inlet distortion in the separated region. Finally, a method of simulating the fan/inlet aerodynamic interaction using blockage sizing method has been defined. With this method, a static blockage device used with a flow-through model will approximate the same inlet onset of separation angle of attack and distortion pattern that would be obtained with an inlet model containing a powered fan.