Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BONE FRACTURES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

315 records · Page 18

Bone Density Following Three Years of Recovery from Long-Duration Space-Flight

Bone loss during long-duration space flight is well recognized, but the long-term implications on bone health following return from flight remain unclear. Among US crew who were involved in long-duration missions in space (Mir and ISS), we have previously shown that at approximately 12 months following return, men, but not women, had BMD values at most sites that were still lower than would be expected had they not been exposed to a prolonged period of microgravity. We now extend our observations to 3 years of follow-up post-flight. Using their age, pre-flight BMD and follow-up time, post-flight BMD values for each US crew were predicted based on the model developed from the community sample. We found BMD measures to be either stable or improve by 3 years relative to their immediate post-flight BMD, however only total hip BMD still remains significantly lower than would be expected had they not been exposed to microgravity. Among male US crew, who have had their BMD measured following at least 3 years of recovery post long-duration flight, they continue to have lower BMD at the hip than would be expected, raising potential concerns regarding future hip fracture risk.

Amin, S.↗

Ultrasound Imaging of Spine: State of the Art and Utility for Space Flight

Introduction: Ultrasound imaging (sonography) has been increasingly used for both primary diagnosis and monitoring of musculoskeletal injury, including fractures. In certain injuries, sonography has been shown to equal or surpass Magnetic Resonance Imaging in accuracy. Long-term exposure to reduced gravity may be expected to cause physiological and anatomical changes of the musculoskeletal system, which are not fully described or understood. In a limited-resource environment like space flight, sonography will likely remain the only imaging modality; therefore, further attention to its potential is warranted, including its ability to image anatomical deviations as well as irregularities of vertebrae and the spinal column. Methods: A thorough review of literature was conducted on the subject. A multipurpose ultrasound system was used to identify specific vertebrae, intervertebral disks, and other structures of the cervical spine in healthy volunteers, selected to represent various age, gender, and Body Mass Index (BMI) groups. Sonographic views were sought that would parallel radiographic views and signs used in the diagnosis of cervical spine injuries. Results: While using widely accepted radiographic signs of cervical spine injury, this sonographic protocol development effort resulted in successful identification of scanning planes and imaging protocols that could serve as alternatives for radiography. Some of these views are also applicable to diagnosing degenerative disk and bone disease, and other non-traumatic spine pathology. Strong, preliminary correlation has been demonstrated in a number of clinical cases between sonography and other imaging modalities. Conclusion: In the absence of radiography, sonography can be used to diagnose or rule out certain common types of cervical spine conditions including injury. Clinical validation of the findings appears to be realistic and would facilitate establishment of new sonographic protocols for special environments with lacking radiographic capability, such as human space flight.

Sargsyan, Ashot E.↗

Blunt Impact Brain Injury using Cellular Injury Criterion

The Advanced Combat Helmet (\ACH") military specification (\mil-spec") requires a helmeted magnesium (\Mg") Department of Transportation (\DOT") headform be dropped vertically, with an impact speed of 3.1 m/s (10 ft/s), onto a steel hemispherical target. The pass/fail criteria are based on translational acceleration (150 G) alone, absent of any rotational component. Without a rotational component, the specification's injury risk application is limited to skull fracture and peripheral hematomas (subdural, subarachnoid), since this translational acceleration injury risk assessment is based on the Wayne State Tolerance Curve (\WSTC"). To provide a more comprehensive view of injury for the entire brain, an alternative approach is needed. To meet this need, we worked with a larger group called PANTHER, a collaboration between national laboratories, industry, and academia. Collaborations specific to research and results presented here come from efforts led by Mr. Ron Szalkowski and Mr. Sushant Malave, Ms. Alice Fawzi, and Dr. Christian Franck. We have developed a prototypical injury risk criterion based on the neuronal response to abrupt changes in general motion (translation, rotation, or both). The cellular-based mild traumatic brain injury (\cbmTBI") criterion utilizes both the strain and strain rate of brain tissue to account for the stretch and rate of stretch that occurs throughout the brain as a result of blunt impact to the head. We conducted physical experiments of an ACH-fitted magnesium headform, which produced repeatable headform peak accelerations. Then, we developed a simulation of the experiment, and validated the simulation output with the experimental data. We then substituted the magnesium headform with a human headform, consisting of skin, muscle, bone, gray matter, white matter, cerebral-spinal fluid, membranes, vasculature, intravertebral discs, airway and sinus. We quantified brain injury risk using the cbmTBI criterion, using the current mil-spec test and a modified test. The modified mil-spec test used an inclined anvil target that was located posterior to the crown of the helmet in the axial plane. While the current mil-spec test produced brain deformation from head translation alone, the modified test produced brain deformation from head translation and rotation, which is closer to most real world and combat theater impacts (e.g., such as occur in tertiary blast exposure). Compared to the current mil-spec test, the modified test produced elevated strains in the human digital twin. These data, mapped to the cbmTBI criterion, suggest increased injury risk for blunt impacts that cause rotation and translation, rather than just translation alone. Moreover, these data may lead to a rotational performance metric, which is rooted in the biology and pathology of the brain's response to impact and blast, and which should be used to improve next-generation helmet designs.

42 ENGINEERING↗

Patterns of Practice in Palliative Radiotherapy for Painful Bone Metastases: A Survey in Japan

Purpose: To determine the current patterns of practice in Japan and to investigate factors that may make clinicians reluctant to use single-fraction radiotherapy (SF-RT). Methods and Materials: Members of the Japanese Radiation Oncology Study Group (JROSG) completed an Internet-based survey and described the radiotherapy dose fractionation they would recommend for four hypothetical cases describing patients with painful bone metastasis (BM). Case 1 described a patient with an uncomplicated painful BM in a non-weight-bearing site from non-small-cell lung cancer. Case 2 investigated whether management for a case of uncomplicated spinal BM would be different from that in Case 1. Case 3 was identical with Case 2 except for the presence of neuropathic pain. Case 4 investigated the prescription for an uncomplicated painful BM secondary to oligometastatic breast cancer. Radiation oncologists who recommended multifraction radiotherapy (MF-RT) for Case 2 were asked to explain why they considered MF-RT superior to SF-RT. Results: A total of 52 radiation oncologists from 50 institutions (36% of JROSG institutions) responded. In all four cases, the most commonly prescribed regimen was 30 Gy in 10 fractions. SF-RT was recommended by 13% of respondents for Case 1, 6% for Case 2, 0% for Case 3, and 2% for Case 4. For Case 4, 29% of respondents prescribed a high-dose MF-RT regimen (e.g., 50 Gy in 25 fractions). The following factors were most often cited as reasons for preferring MF-RT: 'time until first increase in pain' (85%), 'incidence of spinal cord compression' (50%), and 'incidence of pathologic fractures' (29%). Conclusions: Japanese radiation oncologists prefer a schedule of 30 Gy in 10 fractions and are less likely to recommend SF-RT. Most Japanese radiation oncologists regard MF-RT as superior to SF-RT, based primarily on the time until first increase in pain.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Application of Abrasive-Waterjets for Machining Fatigue-Critical Aircraft Aluminum Parts

Current specifications require AWJ-cut aluminum parts for fatigue critical aerospace structures to go through subsequent processing due to concerns of degradation in fatigue performance. The requirement of secondary process for AWJ-machined parts greatly negates the cost effectiveness of waterjet technology. Some cost savings are envisioned if it can be shown that AWJ net cut parts have comparable durability properties as those conventionally machined. To revisit and upgrade the specifications for AWJ machining of aircraft aluminum, “Dog-bone” specimens, with and without secondary processes, were prepared for independent fatigue tests at Boeing and Pacific Northwest National Laboratory (PNNL). Test results show that the fatigue life is proportional to quality levels of machined edges or inversely proportional to the surface roughness Ra . Even at highest quality level, the average fatigue life of AWJ-machined parts is about 30% shorter than those of conventionally machined counterparts. Between two secondary processes, dry-grit blasting with aluminum oxide abrasives until the striation is removed visually yields excellent result. It actually prolongs the fatigue life of parts at least three times higher than that achievable with conventional machining. Dry-grit blasting is relatively simple and inexpensive to administrate and, equally important, alleviates the concerns of garnet embedment.

36 MATERIALS SCIENCE↗

Toughening materials: enhancing resistance to fracture

It has been said that ‘God invented plasticity, but the Devil invented fracture!’ Both mechanisms represent the two prime modes of structural failure, respectively, plastic collapse and the rupture/breaking of a component, but the concept of developing materials with enhanced resistance to fracture can be difficult. This is because fracture resistance invariably involves a compromise—between strength and ductility, between strength and toughness—fundamentally leading to a ‘conflict’ between nano-/micro-structural damage and the mechanisms of toughening. Here, we examine the two major classes of such toughening: (i) intrinsic toughening, which occurs ahead of a crack tip and is motivated by plasticity—this is the principal mode of fracture resistance in ductile materials, and (ii) extrinsic toughening, which occurs at, or in the wake of, a crack tip and is associated with crack-tip shielding—this is generally the sole mode of fracture resistance in brittle materials. We briefly examine how these distinct mechanistic processes have been used to toughen synthetic materials—intrinsically in gradient materials and in multiple principal-element metallic alloys with the example of metallic glasses and high-entropy alloys, and extrinsically in ceramics with the example of ceramic-matrix composites—in comparison to Nature which has been especially adept in creating biological/natural materials which are toughened by one or both mechanistic classes, despite often consisting of constituents with meagre mechanical properties. The success of Nature has been driven by its ability to cultivate the development of materials with multiple length-scale hierarchical structures that display ingenious gradients and structural adaptability, a philosophy which we need to emulate and more importantly learn to synthesize to make structural materials of the future with unprecedented combinations of mechanical properties.

36 MATERIALS SCIENCE↗

Imaging of the hip joint. Computed tomography versus magnetic resonance imaging

The authors reviewed the applications and limitations of computed tomography (CT) and magnetic resonance (MR) imaging in the assessment of the most common hip disorders. Magnetic resonance imaging is the most sensitive technique in detecting osteonecrosis of the femoral head. Magnetic resonance reflects the histologic changes associated with osteonecrosis very well, which may ultimately help to improve staging. Computed tomography can more accurately identify subchondral fractures than MR imaging and thus remains important for staging. In congenital dysplasia of the hip, the position of the nonossified femoral head in children less than six months of age can only be inferred by indirect signs on CT. Magnetic resonance imaging demonstrates the cartilaginous femoral head directly without ionizing radiation. Computed tomography remains the imaging modality of choice for evaluating fractures of the hip joint. In some patients, MR imaging demonstrates the fracture even when it is not apparent on radiography. In neoplasm, CT provides better assessment of calcification, ossification, and periosteal reaction than MR imaging. Magnetic resonance imaging, however, represents the most accurate imaging modality for evaluating intramedullary and soft-tissue extent of the tumor and identifying involvement of neurovascular bundles. Magnetic resonance imaging can also be used to monitor response to chemotherapy. In osteoarthrosis and rheumatoid arthritis of the hip, both CT and MR provide more detailed assessment of the severity of disease than conventional radiography because of their tomographic nature. Magnetic resonance imaging is unique in evaluating cartilage degeneration and loss, and in demonstrating soft-tissue alterations such as inflammatory synovial proliferation.

Review↗

Mineralogical, magnetic and geochemical data constrain the pathways and extent of weathering of mineralized sedimentary rocks

The oxidative weathering of sulfidic rock can profoundly impact watersheds through the resulting export of acidity and metals. Weathering leaves a record of mineral transformation, particularly involving minor redox-sensitive phases, that can inform the development of conceptual and quantitative models. In sulfidic sedimentary rocks, however, variations in depositional history, diagenesis and mineralization can change or overprint the distributions of these trace minerals, complicating the interpretation of weathering signatures. Here we show that a combination of bulk mineralogical and geochemical techniques, micrometer-resolution X-ray fluorescence microprobe analysis and rock magnetic measurements, applied to drill core samples and single weathered fractures, can provide data that enable the development of a geochemically consistent weathering model. This work focused on one watershed in the Upper Colorado River Basin sitting within the Mesaverde Formation, a sedimentary sandstone bedrock with disseminated sulfide minerals, including pyrite and sphalerite, that were introduced during diagenesis and subsequent magmatic-hydrothermal mineralization. Combined analytical methods revealed the pathways of iron (Fe), carbonate and silicate mineral weathering and showed how pH controls element retention or release from the actively weathering fractured sandstone. Drill core logging, whole rock X-ray diffraction, and geochemical measurements document the progression from unweathered rock at depth to weathered rock at the surface. X-ray microprobe analyses of a 1-cm size weathering profile along a fracture surface are consistent with the mobilization of Fe(II) and Fe(III) into acidic pore water from the dissolution of primary pyrite, Fe-sphalerite, chlorite, and minor siderite and pyrrhotite. These reactions are followed by the precipitation of secondary minerals such as of goethite and jarosite, a Fe-(oxyhydr)oxide and hydrous Fe(III) sulfate, respectively. Microscale analyses also helped explain the weathering reactions responsible for the mineralogical transformations observed in the top and most weathered section of the drill core. For example, dissolution of feldspar and chlorite neutralizes the acidity generated by Fe and sulfide mineral oxidation, oversaturating the solution in both Fe-oxides. The combination of X-ray spectromicroscopy and magnetic measurements show that the Fe(III) product is goethite, mainly present either as a coating on fracture surfaces in the actively weathering region of the core or more homogeneously contained within the unconsolidated regolith at the top of the core. Low-temperature magnetic data reveal the presence of ferromagnetic Fe-sulfide pyrrhotite that, although it occurs at trace concentrations, could provide a qualitative proxy for unweathered sulfide minerals because the loss of pyrrhotite is associated with the onset of oxidative weathering. Pyrrhotite loss and goethite formation are detectable through room-temperature magnetic coercivity changes, suggesting that rock magnetic measurements can determine weathering intensity in rock samples at many scales. In conclusion, this work contributes evidence that the weathering of sulfidic sedimentary rocks follows a geochemical pattern in which the abundance of sulfide minerals controls the generation of acidity and dissolved elements, and the pH-dependent mobility of these elements controls their export to the ground- and surface-water.

58 GEOSCIENCES↗

Dog-Bone Horns for Piezoelectric Ultrasonic/Sonic Actuators

A shape reminiscent of a dog bone has been found to be superior to other shapes for mechanical-amplification horns that are components of piezoelectrically driven actuators used in a series of related devices denoted generally as ultrasonic/sonic drill/corers (USDCs). The first of these devices was reported in Ultrasonic/Sonic Drill/Corers With Integrated Sensors (NPO-20856), NASA Tech Briefs, Vol. 25, No. 1 (January 2001), page 38. The dog-bone shape was conceived especially for use in a more recent device in the series, denoted an ultrasonic/ sonic gopher, that was described in Ultrasonic/Sonic Mechanisms for Drilling and Coring (NPO-30291), NASA Tech Briefs, Vol. 27, No. 9 (September 2003), page 65. The figure shows an example of a dog-bone-shaped horn and other components of an ultrasonic gopher. Prerequisite to a meaningful description of this development is an unavoidably lengthy recapitulation of the principle of operation of a USDC and, more specifically, of the ultrasonic/sonic gopher as described previously in NASA Tech Briefs. The ultrasonic actuator includes a stack of piezoelectric rings, the horn, a metal backing, and a bolt that connects the aforementioned parts and provides compressive pre-strain to the piezoelectric stack to prevent breakage of the rings during extension. The stack of piezoelectric rings is excited at the resonance frequency of the overall ultrasonic actuator. Through mechanical amplification by the horn, the displacement in the ultrasonic vibration reaches tens of microns at the tip of the horn. The horn hammers an object that is denoted the free mass because it is free to move longitudinally over a limited distance between hard stops: The free mass bounces back and forth between the ultrasonic horn and a tool bit (a drill bit or a corer). Because the longitudinal speed of the free mass is smaller than the longitudinal speed of vibration of the tip of the horn, contact between the free mass and the horn tip usually occurs at a phase of the vibration favorable to transfer of momentum from the horn to the free mass. Therefore, the free mass picks up momentum and is accelerated back to the tool bit. Upon impact of the free mass on the tool bit, momentum is transferred to the tool bit. The impacts of the free mass on the tool bit repeat at a sonic frequency that can range from tens of hertz to about 1 kHz. The shock waves caused by the impacts of the free mass propagate to the interface between the tool bit and the medium (typically, rock, ice, or other brittle material) to be drilled or cored. The medium becomes fractured when its ultimate strain is exceeded at the medium/tool-bit interface. This concludes the description of the principle of operation.

Sherrit, Stewart↗