Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Air compressor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Two-Phase Cooling for High Packaging Density Planar Inverter: Cooperative Research and Development Final Report, CRADA Number CRD-15-00592

The project objective was to utilize two-phase heat transfer to enable compact and power-dense inverters. The high heat transfer capacity and near isothermal characteristics of two-phase cooling can enable higher power densities, reducing the size and cost of the power electronics system. This project focused on developing efficient, passive (no pump or compressor) two-phase cooling strategies that consist of an air-cooled condenser and evaporator. This report describes the modeling work conducted to design the evaporator and air-cooled condenser for a prototype inverter development work underway in the John Deere. Prototypes of the final evaporator and condenser designs were then fabricated via 3D printing for testing. Experiments on the evaporator confirmed that this component can meet the heat load and junction temperatures requirements for Si IGBT (insulated-gate bipolar transistor) inverter. Experiments with the air-cooled condenser were not possible due to leaks through the condenser walls.

33 ADVANCED PROPULSION SYSTEMS↗

The FML compressor as a drive system for the LFSWT: A narrative

During 1988, a feasibility study was performed to decide how best to build a Laminar Flow Supersonic Wind Tunnel (LFSWT) at the NASA-Ames Fluid Mechanics Laboratory (FML) for boundary layer transition research. A full report was received in June 1988. The report was based on the following guidelines: continuous operation at Mach numbers within the range from 1.8-4.0 was required to impact the NASA 'HiStar' project; low disturbance flow is essential for transition research; minimum test section height is 8 inches; tunnel must fit in an FML test cell; tunnel design should be simple; and construction costs should be minimized. The study considered three drive system options: (1) use surplus JPL compressors and support equipment; (2) use of the FML compressor with ambient injectors; and (3) use of the FML compressor with injectors driven by the NASA-Ames 3000 psia air supply.

Laub, James↗

Water Misting and Injection of Commercial Aircraft Engines to Reduce Airport NOx

This report provides the first high level look at system design, airplane performance, maintenance, and cost implications of using water misting and water injection technology in aircraft engines for takeoff and climb-out NOx emissions reduction. With an engine compressor inlet water misting rate of 2.2 percent water-to-air ratio, a 47 percent NOx reduction was calculated. Combustor water injection could achieve greater reductions of about 85 percent, but with some performance penalties. For the water misting system on days above 59 F, a fuel efficiency benefit of about 3.5 percent would be experienced. Reductions of up to 436 F in turbine inlet temperature were also estimated, which could lead to increased hot section life. A 0.61 db noise reduction will occur. A nominal airplane weight penalty of less than 360 lb (no water) was estimated for a 305 passenger airplane. The airplane system cost is initially estimated at $40.92 per takeoff giving an attractive NOx emissions reduction cost/benefit ratio of about $1,663/ton.

Daggett, David L.↗

An Investigation of the McDonnell XP-85 Airplane in the Ames 40- by 80-Foot Wind Tunnel: Pressure-Distribution Tests

Pressure measurements were made during wind-tunnel tests of the McDonnell XP-85 parasite fighter. Static-pressure orifices were located over the fuselage nose, over the canopy, along the wing root, and along the upper and lower stabilizer roots. A total-pressure and static-pressure rake was located in the turbojet engine air-intake duct. It was installed at the station where the compressor face would be located. Pressure data were obtained for two airplane conditions, clean and with skyhook extended, through a range of angle of attack and a range of yaw.

Hunton, Lynn W.↗

Supersonic Wind Tunnel Capabilities Expanded Into Subsonic Region

The operating envelope of the Abe Silverstein 10- by 10-Foot Supersonic Wind Tunnel (10x10 SWT) at the NASA Lewis Research Center was recently expanded to include operation at subsonic test section speeds. This new capability generates test section air speeds ranging from Mach 0.05 to 0.35 (32 to 240 kn). Most of the expansion in air speed range was obtained by running the tunnel's main compressor at much lower speeds than ever before. The compressor drive system, consisting of four large electric motors, was run with only one or two motors energized to obtain the lower compressor speed range. This new capability makes the 10x10 SWT more versatile and gives U.S. researchers an enhanced ability to perform subsonic propulsion and aerodynamic testing.

Roeder, James W., Jr.↗

Variable-Speed Induction Motor Drives for Aircraft Environmental Control Compressors

New, more-efficient designs for aircraft jet engines are not capable of supplying the large quantities of bleed air necessary to provide pressurization and air conditioning for the environmental control systems (ECS) of the next generation of large passenger aircraft. System analysis and engineering have determined that electrically-driven ECS can help to maintain the improved fuel efficiencies; and electronic controllers and induction motors are now being developed in a NASA/NPD SBIR Program to drive both types of ECS compressors. Previous variable-speed induction motor/controller system developments and publications have primarily focused on field-oriented control, with large transient reserve power, for maximum acceleration and optimum response in actuator and robotics systems. The application area addressed herein is characterized by slowly-changing inputs and outputs, small reserve power capability for acceleration, and optimization for maximum efficiency. This paper therefore focuses on the differences between this case and the optimum response case, and shows the development of this new motor/controller approach. It starts with the creation of a new set of controller requirements. In response to those requirements, new control algorithms are being developed and implemented in an embedded computer, which is integrated into the motor controller closed loop. Buffered logic outputs are used to drive the power switches in a resonant-technology, power processor/motor-controller, at switching/resonant frequencies high enough to support efficient high-frequency induction motor operation at speeds up to 50,000-RPA

Mildice, J. W.↗

Field Validation of Air-Source Heat Pumps for Cold Climates

Heating energy is the largest end-use for U.S. residential buildings accounting for approximately one-third of residential building energy consumption (EIA 2021). Historically, air-source heat pumps have been limited to temperate climates because of subpar performance at extremely cold outdoor air temperatures. However, recent advances to cold-climate air-source heat pump technology, which typically rely on inverter-driven, variable-speed compressors and variable-speed fans, have significantly improved low-temperature heat pump performance enabling the technology to save energy for many homes in cold climates. The primary objective of this project was to measure in-field performance of centrally ducted, variable-capacity air-source heat pumps in cold climates to validate performance and develop field-based performance maps. The project focused on quantifying heat pump performance at cold temperatures. The sites identified for the study were primarily located in the Northwest United States since homes in the region tend to have all-electric space heating systems and high-efficiency heat pumps have been incentivized in the region for several years. NREL partnered with Ecotope, Inc., a small energy consulting firm located in Seattle, WA, for site recruitment, monitoring equipment installation, data quality management. All the sites included in the study had previously installed a high-efficiency, central heat pump system. One site was in a Denver, CO suburb, which was the only dual fuel heat pump in the study. We used airside and power measurements, collected at 5-second intervals, to quantify heat pump capacity, coefficient of performance (COP), and auxiliary heater energy consumption. We developed algorithms to automatically determine the heat pump operating mode including defrost and auxiliary heating operation. A whole-house thermal and duct audit was completed during the initial site visit to estimate winter heating loads and assess heat pump sizing. Whole-home heating design loads were calculated at ASHRAE 99% design temperatures and compared to manufacturer-reported maximum capacities to assess the heat pump sizing at each site.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Windmilling of the rotor of a turbojet engine with an axial-flow compressor under flight conditions

The concept of rotor windmilling is understood to mean rotation of the rotor caused solely by the energy of the air (not gas) streaming through the apertures between the blades (under conditions of power shut-off) under the action of dynamic pressure. The concept of windmilling is analyzed for an engine with an axial-flow compressor, showing that windmilling must be taken into account in such cases as in-flight reignition of the engine. A graph-analytic method for determining the range of windmilling is proposed.

Borgon, J.↗

Axial-Flow Compressor Performance With Water Ingestion

Stage-stacking computer code (WISGSK) developed for prediction of offdesign axial-flow compressor performance with water ingestion. Code uses meantime stage-stacking method; stage and cumulative compressor performance calculated utilizing representative triangles located at rotor inlet and outlet mean radii. Code provides options for calculation of performance with mixtures of gases such as air and water vapor and air/water droplet mixtures with different water contents. Useful for obtaining preliminary estimates of overall performance of compressors with water ingestion given design point details corresponding to airflow and nature of corrections for air/water mixture flow.

Tsuchiya, T.↗

Apparatus and Method for Measuring Air Temperature Ahead of an Aircraft for Controlling a Variable Inlet/Engine Assembly

The apparatus and method employ remote sensing to measure the air temperature a sufficient distance ahead of the aircraft to allow time for a variable inlet/engine assembly to be reconfigured in response to the measured temperature, to avoid inlet unstart and/or engine compressor stall. In one embodiment, the apparatus of the invention has a remote sensor for measuring at least one air temperature ahead of the vehicle and an inlet control system for varying the inlet. The remote sensor determines a change in temperature value using at least one temperature measurement and prior temperature measurements corresponding to the location of the aircraft. The control system uses the change in air temperature value to vary the inlet configuration to maintain the position of the shock wave during the arrival of the measured air in the inlet. In one embodiment, the method of the invention includes measuring at least one air temperature ahead of the vehicle, determining an air temperature at the vehicle from prior air temperature measurements, determining a change in temperature value using the air temperature at the vehicle and the at least one air temperature measurement ahead of the vehicle, and using the change in temperature value to-reposition the airflow inlet, to cause the shock wave to maintain substantially the same position within the inlet as the airflow temperature changes within the inlet.

Gary, Bruce L.↗

Hot-salt stress-corrosion of titanium alloys as related to turbine operation

In an effort to simulate typical compressor operating conditions of current turbine engines, special test facilities were designed. Air velocity, air pressure, air dewpoint, salt deposition temperature, salt concentration, and specimen surface condition were systematically controlled and their influence on hot-salt stress-corrosion evaluated. The influence of both continuous and cyclic stress-temperature exposures was determined. The relative susceptibility of a variety of titanium alloys in commonly used heat-treated conditions was determined. The effects of both environmental and material variables were used to interpret the behavior of titanium alloys under hot-salt stress-corrosion conditions found in jet engines and to appraise their future potential under such conditions.

Gray, H. R.↗

Experimental Investigation of a Five-stage Axial-flow Research Compressor with Transonic Rotors in All Stages III : Interstage Data and Individual Stage Performance Characteristics

For use in computing the detailed performance parameters of individual blade rows of a multistage compressor, radial distributions of total pressure, total temperature, static pressure and air-flow angle are tabulated. The data cover a range of air flow from choke to the approximate surge limit for equivalent rotor speeds from 70 to 100 percent of design. Equivalent stage performance curves determined from the radial survey measurements indicate both the individual performance and the matching of the stages at the speeds investigated.

Sandercock, Donald M↗

Program For Analysis Of Axial-Flow Compressors

CSPAN (Compressor SPanline ANalysis) computer program assists in design of axial-flow compressors. Enables design engineer to study relationships among number of stages, flow-path radii, gas velocities, flow angles, and resultant variation of compressor efficiency. Rapidly provides conceptual designs for preliminary design studies of air-breathing engines. Written in FORTRAN 77.

Glassman, Arthur J.↗

Staged regenerative sorption heat pump

A regenerative adsorbent heat pump process and system for cooling and heating a space. A sorbent is confined in a plurality of compressors of which at least four are first stage and at least four are second stage. The first stage operates over a first pressure region and the second stage over a second pressure region which is higher than the first. Sorbate from the first stage enters the second stage. The sorbate loop includes a condenser, expansion valve, evaporator and the compressors. A single sorbate loop can be employed for single-temperature-control such as air conditioning and heating. Two sorbate loops can be used for two-temperature-control as in a refrigerator and freezer. The evaporator temperatures control the freezer and refrigerator temperatures. Alternatively the refrigerator temperature can be cooled by the freezer with one sorbate loop. A heat transfer fluid is circulated in a closed loop which includes a radiator and the compressors. Low temperature heat is exhausted by the radiator. High temperature heat is added to the heat transfer fluid entering the compressors which are desorbing vapor. Heat is transferred from compressors which are sorbing vapor to the heat transfer fluid, and from the heat transfer fluid to the compressors which are desorbing vapor. Each compressor is subjected to the following phases, heating to its highest temperature, cooling down from its highest temperature, cooling to its lowest temperature, and warming up from its lowest temperature. The phases are repeated to complete a cycle and regenerate heat.

Jones, Jack A.↗

Static Flow Characteristics of a Mass Flow Injecting Valve

A sleeve valve is under development for ground-based forced response testing of air compression systems. This valve will be used to inject air and to impart momentum to the flow inside the first stage of a multi-stage compressor. The valve was designed to deliver a maximum mass flow of 0.22 lbm/s (0.1 kg/s) with a maximum valve throat area of 0.12 sq. in (80 sq. mm), a 100 psid (689 KPA) pressure difference across the valve and a 68 F, (20 C) air supply. It was assumed that the valve mass flow rate would be proportional to the valve orifice area. A static flow calibration revealed a nonlinear valve orifice area to mass flow relationship which limits the maximum flow rate that the valve can deliver. This nonlinearity was found to be caused by multiple choking points in the flow path. A simple model was used to explain this nonlinearity and the model was compared to the static flow calibration data. Only steady flow data is presented here. In this report, the static flow characteristics of a proportionally controlled sleeve valve are modelled and validated against experimental data.

Mattern, Duane↗

Method of Matching Performance of Compressor Systems with that of Aircraft Power Sections

A method is developed of easily determining the performance of a compressor system relative to that of the power section for a given altitude. Because compressors, reciprocating engines, and turbines are essentially flow devices, the performance of each of these power-plant components is presented in terms of similar dimensionless ratios. The pressure and temperature changes resulting from restrictions of the charge-air flow and from heat transfer in the ducts connecting the components of the power plant are also expressed by the same dimensionless ratios and the losses are included in the performance of the compressor. The performance of a mechanically driven, single-stage compressor in relation to the performance of a conventional air-cooled engine operating at sea-level conditions is presented as an example of the application of the method.

Bullock, Robert O.↗

Ice Protection of Turbojet Engines by Inertia Separation of Water III : Annular Submerged Inlets

Aerodynamic and icing studies were conducted on a one-half-scale model of an annular submerged inlet for use with axial-flow turbojet engines. Pressure recoveries, screen radial-velocity profiles, circumferential mass-flow variations, and icing characteristics were determined at the compressor inlet. In order to be effective in maintaining water-free induction air, the inlet gap must be extremely small and ram-pressure recoveries consequently are low, the highest achieved being 65 percent at inlet-velocity ratio of 0.86. All inlets exhibited considerable screen icing. Severe mass-flow shifts occurred at angles of attack.

ICE PREVENTION AND REMOVAL - PROPULSION SYSTEMS↗

Analysis of the turbojet engine for propulsion of supersonic fighter airplanes / David S. Gabriel, Richard P. Krebs, E.Clinton Wilcox, Stanley L.Koutz

An analytical investigation was made of two supersonic interceptor type airplanes to determine the most desirable turbojet engine characteristics for this application The airplanes were designed differently primarily because of the amount of subsonic flight incorporated in the flight plan--one flight having none and the other, a cruise radius of 400 nautical miles. Several power plant design variables were varied independently to determine the effect of changes in each parameter on airplane performance. These parameters included compressor pressure ratio, compressor efficiency, turbine-inlet temperature, afterburner temperature, engine specific weight, and air-handling capacity. The effects of using a convergent-divergent exhaust nozzle and of changing the design flight Mach number were also investigated.

ENGINES, TURBOJET↗